The chassis and power supply specifications are described in Table A-1.
| Description | Specifications |
|---|---|
Dimensions (H x W x D) | 25 x 17.75 x 19.75 in. (62.5 x 43.13 x 48.2 cm) |
Chassis only: 70 lb (31.7 kg) | |
200 lfm1 through the system fan assembly | |
32 to 104ºF (0 to 40ºC) | |
Nonoperating temperature | -40 to 167ºF (-40 to 75ºC) |
Humidity | 10 to 90%, noncondensing, operating |
Altitude, operating | -500 to 6562 ft. (-52 to 2000 m) |
Vibration, operating | 5 to 200 Hz, 0.5 g (1 octet/min) |
Vibration, nonoperating | 5 to 200 Hz, 1 g (1 octet/min) |
Mean time between failures | 7.1 years for system configuration |
Compliance | CE Mark |
Maximum dissipated power at -48VDC | 1A |
Safety | UL 19502, CSA-C22.2 No. 9503, EN 609504, IEC 609505, TS 0016, AS/NZS 32607, EN 60825, IEC 60825, 21 CFR 1040 |
FCC10 Part 15 Class A (CFR 47), ICES11-003 Class A, EN 55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI12 Class A with UTP13 cables EN 55022 Class B; CISPR22 Class B, AS/NZS 3548 Class B, and VCCI Class B with FTP14 cables | |
| AC Power Supply Specifications | |
AC total output | 1300W maximum |
AC voltage | 100 to 240 VAC wide input with power factor correction |
Power supply load | 1300W maximum configuration, 1000W typical with maximum configuration |
AC current | Rated 16 to 8A |
Heat dissipation | 1760W (6000 Btu/hr15) |
AC frequency | 50 to 60 Hz |
| DC Power Supply Specifications | |
DC total output | 1360W maximum |
DC voltage | -48 to -60 VDC continuous |
Power supply load | 1360W maximum, 1000W typical with maximum configuration |
Maximum dissipated power at -48VDC | 1/2A |
DC current | Rated 40A |
Heat dissipation | 1800 W (6140 Btu/hr) |
DC voltages supplied and steady-state maximum current ratings | +3V3 @ 15.0A |
DC wire gauge | |
| 1lfm = linear feet per minute. 2UL = Underwriters Laboratories. 3CSA = Canadian Standards Association. 4EN = European Norm. 5IEC = International Electrotechnical Commission. 6TS = Technical Standard. 7AS/NZS = Australian/New Zealand Standard. 8EMI = electromagnetic interference. 9LightStream 1010 port adapters installed in a Catalyst 8540 MSR chassis may not be EMI compliant. An EMI strip ships with the chassis for installation on the port adapters to meet EMI compliance. 10FCC = Federal Communications Commission. 11ICES = Interference-Causing Equipment Standard. 12VCCI = Voluntary Control Council for Information Technology Equipment. 13UTP = unshielded twisted-pair. 14FTP = foil twisted-pair. 15Btu = British thermal units per hour. 16The DC terminal block has been evaluated for use with maximum 8 AWG. 17AWG = American Wire Gauge. 18You can use smaller wire if the minimum input voltage for the installation is not violated. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Thu Sep 21 13:33:24 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.