Chassis and Power Supply Specifications

Chassis and Power Supply Specifications

The chassis and power supply specifications are described in Table A-1.


Table A-1: Chassis and Power Supply Specifications
Description Specifications

Dimensions (H x W x D)

25 x 17.75 x 19.75 in. (62.5 x 43.13 x 48.2 cm)
Chassis depth including cable guide: 21.64 in. (55.0 cm)
Power supply: 7.1 x 7.9 x 15.3 in. (20.1 x 18.1 x 38.9 cm)

Weight

Chassis only: 70 lb (31.7 kg)
Chassis fully configured with 2 route processors, 8 line modules, 3 switch modules, and 2 power supplies:160 lb (72.5 kg)
AC power supply: 22 lb
DC power supply: 25 lb

Airflow

200 lfm1 through the system fan assembly

Operating temperature

32 to 104ºF (0 to 40ºC)

Nonoperating temperature

-40 to 167ºF (-40 to 75ºC)

Humidity

10 to 90%, noncondensing, operating
5 to 95%, noncondensing, nonoperating, and storage

Altitude, operating

-500 to 6562 ft. (-52 to 2000 m)

Vibration, operating

5 to 200 Hz, 0.5 g (1 octet/min)

Vibration, nonoperating

5 to 200 Hz, 1 g (1 octet/min)
200 to 500 Hz, 2 g (1 octet/min)

Mean time between failures

7.1 years for system configuration

Compliance

CE Mark

Maximum dissipated power at -48VDC

1A

Safety

UL 19502, CSA-C22.2 No. 9503, EN 609504, IEC 609505, TS 0016, AS/NZS 32607, EN 60825, IEC 60825, 21 CFR 1040

EMI8,9

FCC10 Part 15 Class A (CFR 47), ICES11-003 Class A, EN 55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI12 Class A with UTP13 cables

EN 55022 Class B; CISPR22 Class B, AS/NZS 3548 Class B, and VCCI Class B with FTP14 cables

AC Power Supply Specifications

AC total output

1300W maximum

AC voltage

100 to 240 VAC wide input with power factor correction

Power supply load

1300W maximum configuration, 1000W typical with maximum configuration

AC current

Rated 16 to 8A
Maximum power budget: 17.6A @ 100 VAC, 60 Hz
14.6A @ 115 VAC, 60 Hz; 7A @ 230 VAC, 50 Hz with chassis fully configured

Heat dissipation

1760W (6000 Btu/hr15)

AC frequency

50 to 60 Hz

DC Power Supply Specifications

DC total output

1360W maximum

DC voltage
Typical range
(U.S. and Canada)
Typical range
(international)

-48 to -60 VDC continuous
-48 VDC (nominal) -56 VDC (high) -42 VDC (low)

-60 VDC (nominal) -72 VDC (high) -52 VDC (low)

Power supply load

1360W maximum, 1000W typical with maximum configuration

Maximum dissipated power at -48VDC

1/2A

DC current

Rated 40A
Maximum power draw: 43A @ 42 VDC, 38A @ 48 VDC, 30A @ 60 VDC with chassis fully configured

Heat dissipation

1800 W (6140 Btu/hr)

DC voltages supplied and steady-state maximum current ratings

+3V3 @ 15.0A
+5V @ 5.0A
+12V @ 6.0A
+42V @ 28.84A

DC wire gauge
for power cable

816 AWG17, 90º, copper conductor (recommended18)

1lfm = linear feet per minute.
2UL = Underwriters Laboratories.
3CSA = Canadian Standards Association.
4EN = European Norm.
5IEC = International Electrotechnical Commission.
6TS = Technical Standard.
7AS/NZS = Australian/New Zealand Standard.
8EMI = electromagnetic interference.
9LightStream 1010 port adapters installed in a Catalyst 8540 MSR chassis may not be EMI compliant. An EMI strip ships with the chassis for installation on the port adapters to meet EMI compliance.
10
FCC = Federal Communications Commission.
11ICES = Interference-Causing Equipment Standard.
12VCCI = Voluntary Control Council for Information Technology Equipment.
13UTP = unshielded twisted-pair.
14FTP = foil twisted-pair.
15Btu = British thermal units per hour.
16The DC terminal block has been evaluated for use with maximum 8 AWG.
17AWG = American Wire Gauge.
18You can use smaller wire if the minimum input voltage for the installation is not violated.