The chassis and power supply specifications are described in Table A-1.
| Description | Specifications |
|---|---|
Dimensions (H x W x D) | 25 x 17.75 x 19.75 in. (62.5 x 43.13 x 48.2cm) |
Weight | Chassis only: 70 lb (31.7 kg) |
200 lfm1 through the system fan assembly | |
Operating temperature | 32 to 104ºF (0 to 40ºC) |
Nonoperating temperature | -40 to 167ºF (-40 to 75ºC) |
Humidity | 10 to 90%, noncondensing |
Altitude | -500 to 10,000 ft. (-52 to 3,048 m) |
Mean time between failures | 7.1 years for system configuration |
Compliance | CE Marking |
Safety | UL2 1950, CSA3 -C22.2 No. 950, EN4 60950, IEC5 950, TS6 001, AS/NZS7 3260 |
FCC10 Part 15 Class A (CFR 47), ICES11-003 Class A, EN 55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI12 Class A with UTP13 cables EN 55022 Class B; CISPR22 Class B, AS/NZS 3548 Class B, and VCCI Class B with FTP14 cables | |
| AC Power Supply Specifications | |
AC total output | 1300W maximum |
AC-input voltage | 90 to 264 VAC wide input with power factor correction |
AC frequency | 50 to 60 Hz |
Power supply load | 1300W maximum configuration, 1000W typical with maximum configuration |
AC current | Rated 16 to 8A |
AC voltages supplied and steady-state maximum current ratings | +3V3 @ 15.0A |
Heat dissipation | 1760W (6000 Btu15/hr) |
| DC Power Supply Specifications | |
DC total output | 1360W maximum |
Power supply load | 1360W maximum, 1000W typical with maximum configuration |
DC input current | Rated 40A |
DC voltages supplied and steady-state maximum current ratings | +3V3 @ 15.0A |
DC-input voltage | -48 to -60 VDC continuous |
Heat dissipation | 1800 W (6140 Btu/hr) |
DC wire gauge | |
| 1lfm = linear feet per minute 2UL = Underwriters Laboratories 3CSA = Canadian Standards Association 4EN = European Norm 5IEC = International Electrotechnical Commission 6TS = Technical Standard 7AS/NZS = Australian/New Zealand Standard 8EMI = electromagnetic interference 9LightStream 1010 port adapters installed in a Catalyst 8540 MSR chassis may not be EMI compliant. An EMI strip ships with the chassis for installation on the port adapters to meet EMI compliance. 10FCC = Federal Communications Commission 11ICES = Interference-Causing Equipment Standard 12VCCI = Voluntary Control Council for Information Technology Equipment 13UTP = unshielded twisted-pair 14FTP = foiled twisted-pair 15Btu = British thermal units 16The DC terminal block has been evaluated for use with maximum 8 AWG 17AWG = American Wire Gauge 18You can use smaller wire if the minimum input voltage for the installation is not violated |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Thu Sep 2 10:11:30 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.