The switch route processor and line module specifications are described in Table A-1.
For the five-slot switch chassis and common equipment specifications, refer to the appendix "System Chassis Specifications" in the Catalyst 8510 Campus Switch Router Chassis Installation Guide.
| Description | Specifications |
|---|---|
Switch and processor capacity | 10 Gbps shared memory, nonblocking switch fabric |
Dimensions (H x W x D) | 1.2 x 14.4 x 16 in. (3.0 x 36.6 x 40.6 cm) |
Weight | Processor: 6.85 lb (3.09 kg) |
DC voltages supplied and steady-state maximum current ratings | System: +5V1 @ 70A2 |
Operating temperature | 32 to 104ºF (0 to 40ºC) |
Nonoperating temperature | -40 to 167ºF (-40 to 75ºC) |
Humidity | 10 to 90%, noncondensing |
Altitude | -500 to 10,000 ft. (-52 to 3048 m) |
Microprocessor | 100-MHz MIP4 R4700 |
Memory | 8-MB Flash memory SIMM5 (upgradable to 16 MB) |
Management access | Standard Ethernet and dual EIA/TIA-23210 serial ports on the switch route processor |
Interface ports | RJ-45 IEEE11 802.3 Ethernet 10BaseT port |
Line Modules | 8 10/100BaseT Ethernet ports (RJ-45), 16K or 64K RAM |
Network management | Port TX12 and RX13 LEDs, 10/100 operation and link LEDs |
Management Information Bases (MIBs) | SNMP17 MIB II (RFC 1213) |
Maximum | UTP18 cable: 328 ft (100 m) with four or fewer separate cable segments on the path; |
Fiber-Optic Power Levels: | 1261 to 1360 nm19 |
Agency Approvals | UL21 1950 (U.S.) |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Tue Nov 16 08:54:27 PST 1999
Copyright 1989-1999©Cisco Systems Inc.