The chassis and power supply specifications are described in Table B-1.
| Description | Specifications |
|---|---|
Dimensions (H x W x D) | 10.4 x 17.25 x 18.4 in. (26.4 x 43.1 x 46.0 cm) |
Weight | Chassis only: 32 lb (13.6 kg) |
Airflow | 95 cfm1 through the system fan assembly |
Operating temperature | 32 to 104ºF (0 to 40ºC) |
Nonoperating temperature | -40 to 167ºF (-40 to 75ºC) |
Humidity | 10 to 90%, noncondensing |
Altitude | -500 to 10,000 ft (-52 to 3,048 m) |
Mean time between failures | 2.6 years for system configuration |
Compliance | CE Marking |
Safety | UL2 1950, CSA3 -C22.2 No. 950, EN4 60950, IEC5 950, TS6 001, AS/NZS7 3260 |
EMI8 | FCC9 Class A (47 CFR, Part 15), ICES10-003 Class A, EN 55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI11 Class A with UTP12 cables EN 55022 Class B; COSPR22 Class B, AS/NZS 354 B, and VCCI Class B with STP13 cables |
| AC Power Supply Specifications | |
AC total output | 376W maximum |
AC-input voltage | 100-127/200-240 VAC wide input with power factor correction |
AC frequency | 50 to 60 Hz |
AC current rating | 8/4 A |
Power supply load | 376W maximum configuration, 200W typical with maximum configuration |
DC voltages supplied and steady-state maximum current ratings | +5V @ 70A |
Heat dissipation | 563W (1919 Btu14/hr) |
| DC Power Supply Specifications | |
DC total output | 388W maximum |
DC-input current | 12A maximum @ 48 VDC (nominal) |
Power supply load | 388W maximum, 200W typical with maximum configuration |
DC voltages supplied and steady-state maximum current ratings | +5V @ 70A |
DC input voltage | -48 to -60 VDC continuous |
Heat dissipation | 600 W (2040 Btu/hr) |
DC wire gauge | |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed Oct 27 12:14:50 PDT 1999