cc/td/doc/product/l3sw/4908g_l3/ios_12/7w515d
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Switch Router Specifications

Switch Router Specifications

Table A-1 lists the specifications for the Catalyst 4908G-L3 switch router.


Table A-1: Catalyst 4908G-L3 Switch Router Specifications
Specification Description

Environmental

Temperature, ambient operating

32 to 104°F (0 to 40°C)

Temperature, ambient nonoperating and storage

-40 to 167°F (-40 to 75°C)

Humidity (RH), ambient (noncondensing) operating

10 to 90 percent

Humidity (RH), ambient (noncondensing) nonoperating and storage

5 to 95 percent

Altitude, operating and nonoperating

-60 to 2,000 m

Switching Components

Backplane

22 Gbps full duplex

Microprocessor

150-MHz R5000 RISC-Y2K compliant

Memory

64 MB of SDRAM, 16 MB of Flash ROM (onboard), 128 KB of NVRAM,12 MB of synchronous SRAM, 256 bytes serial EEROM

Physical Characteristics

Dimensions (H x W x D)

2.625 x 17.5 x 18 in. (6.6 x 44 x 45.7 cm)
1.5 RU1

Weight

18 lb (8.1 kg)

AC Power

Power supply output

175W

System power dissipation

240W

AC

3A maximum @ 100 VAC
1A maximum @ 240 VAC
820 BTU/hr2

AC frequency

50 to 60 Hz

KVA rating3

0.240 KVA

Airflow

Front, right, and left side in, rear out

Standards Compliance

Compliance

CE Marking

Safety

UL 19504, CSA-C22.2 No. 9505, EN 609506, IEC 9507, IEC 60825, EN 60825, 21 CFR 10408

EMI9

FCC Class A (CFR 47, part 15)10, ICES-003 Class A11, EN55022 Class A, CISPR2212 Class A, AS/NZS 354813 Class A, and VCCI14 Class A with UTP15 cables EN55022 Class B, CISPR22 Class B, AS/NZS 3548 Class B, and VCCI Class B with FTP cables

1RU = rack units
2BTU/hr = British Thermal Units per hour
3KVA = kilovolts ampere
4UL = Underwriters Laboratory
5CSA = Canadian Standards Association
6EN = European Norm
7IEC = International Electrotechnical Commission
8CFR = Code of Federal Regulations
9EMI = electromagnetic interference
10FCC = Federal Communications Commission
11ICES = International Commerce Exchange Systems
12CISPR = Comite Internations Special Des Perturbations Radioelectrigues
13AS/NZS = Australia/New Zealand Standards
14VCCI = Voluntary Control Council for Information Technology Equipment
15UTP = unshielded twisted-pair