The console port is an RJ-45 receptacle. Data terminal ready (DTR) and data set ready (DSR) handshake signals are supported. The Request To Send (RTS) signal tracks the state of the Clear To Send (CTS) signal. Table B-1 lists the console port pinouts.
| Pin | Signal | Direction | Description |
|---|---|---|---|
11 | RTS/CTS | Output | Request to send / Clear to send |
2 | DTR | Output | Data terminal ready |
3 | TxD | Output | Transmit data |
4 | SGND | --- | Signal ground |
5 | SGND | --- | Signal ground |
6 | RxD | Input | Receive data |
7 | DSR | Input | Data set ready |
81 | RTS/CTS | Input | Request to send / Clear to send |
| 1Pin 1 and pin 8 are connected. |
The Auxiliary port is an RJ-45 receptacle that supports remote console interfaces using a modem. Table B-2 lists the auxiliary port pinouts.
Table B-3 provides cabling specifications for the Gigabit Interface Converters (GBICs) that you install into the Gigabit Ethernet port modules. Note that all GBIC ports have SC-type connectors, and the minimum cable distance for all GBICs listed is 6.5 feet (2 meters).
| GBIC | Wavelength (nm1) | Fiber Type | Core Size (micron) | Modal Bandwidth (MHz.km) | Cable Distance |
|---|---|---|---|---|---|
850 | MMF4
| 62.5 62.5 50.0 50.0 | 160 200 400 500 | 722 ft (220 m) 902 ft (275 m) 1640 ft (500 m) 1804 ft (550 m) | |
LX/LH5 | 1300 | MMF6
SMF7 (LX/LH) | 62.5 50.0 50.0 9/10 | 500 400 500 --- | 1804 ft (550 m) 1804 ft (550 m) 1804 ft (550 m) 32,810 ft (10 km) |
ZX8 | 1550 | SMF | Not conditional | --- | 70 to 100 km |
| 1nm = nanometers 2SX = short wavelength 3MMF only 4MMF = multimode fiber 5LX/LH = long wavelength/long haul 6Patch cord required (see the "Patch Cord" section for details) 7SMF = single-mode fiber 8ZX = extended distance |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Jun 5 17:20:00 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.