Console Port

The console port is an RJ-45 receptacle. Data terminal ready (DTR) and data set ready (DSR) handshake signals are supported. The Request To Send (RTS) signal tracks the state of the Clear To Send (CTS) signal. Table B-1 lists the console port pinouts.


Table B-1: Console Port Pinouts
Pin Signal Direction Description

11

RTS/CTS

Output

Request to send / Clear to send

2

DTR

Output

Data terminal ready

3

TxD

Output

Transmit data

4

SGND

---

Signal ground

5

SGND

---

Signal ground

6

RxD

Input

Receive data

7

DSR

Input

Data set ready

81

RTS/CTS

Input

Request to send / Clear to send

1Pin 1 and pin 8 are connected.

Auxiliary Port

The Auxiliary port is an RJ-45 receptacle that supports remote console interfaces using a modem. Table B-2 lists the auxiliary port pinouts.


Table B-2: Auxiliary Port Pinouts
Pin Signal Direction Description

1

RTS

Output

Request to send

2

DTR

Output

Data terminal ready

3

TxD

Output

Transmit data

4

SGND

---

Signal ground

5

SGND

---

Signal ground

6

RxD

Input

Receive data

7

DSR

Input

Data set ready

8

CTS

Input

Clear to send

Gigabit Ethernet Ports

Table B-3 provides cabling specifications for the Gigabit Interface Converters (GBICs) that you install into the Gigabit Ethernet port modules. Note that all GBIC ports have SC-type connectors, and the minimum cable distance for all GBICs listed is 6.5 feet (2 meters).


Table B-3: Gigabit Ethernet Port Cabling Specifications
GBIC Wavelength
(nm1)
Fiber Type Core Size (micron) Modal Bandwidth (MHz.km) Cable Distance

SX2'3

850

MMF4

62.5

62.5

50.0

50.0

160

200

400

500

722 ft (220 m)

902 ft (275 m)

1640 ft (500 m)

1804 ft (550 m)

LX/LH5

1300

MMF6

SMF7 (LX/LH)

62.5

50.0

50.0

9/10

500

400

500

---

1804 ft (550 m)

1804 ft (550 m)

1804 ft (550 m)

32,810 ft (10 km)

ZX8

1550

SMF

Not conditional

---

70 to 100 km

1nm = nanometers
2SX = short wavelength
3MMF only
4MMF = multimode fiber
5LX/LH = long wavelength/long haul
6Patch cord required (see the "Patch Cord" section for details)
7SMF = single-mode fiber
8ZX = extended distance


hometocprevnextglossaryfeedbacksearchhelp