This appendix provides technical and port specifications for the Catalyst 2948G-L3 switch router.
Table A-1 lists the specifications for the Catalyst 2948G-L3 switch router.
| Specification | Description | |
|---|---|---|
Environmental |
|
|
Temperature, ambient operating | 32 to 104°F (0 to 40°C) | |
Temperature, ambient nonoperating and storage | -40 to 167°F (-40 to 75°C) | |
Humidity (RH), ambient (noncondensing) operating | 10 to 90 percent | |
Humidity (RH), ambient (noncondensing) nonoperating and storage | 5 to 95 percent | |
Altitude, operating and nonoperating | -60 to 2,000 m | |
| Switching Components | ||
Backplane | 20 Gbps full duplex | |
Microprocessor | 150-MHz R5000 RISC-Y2K Compliant | |
64 MB of SDRAM, 16 MB of Flash ROM (onboard), | ||
| Physical Characteristics | ||
2.625 x 17.5 x 18 in. (6.6 x 44 x 45.7 cm) | ||
18 lb (8.1 kg) | ||
| AC Power | ||
Power supply output | 175W | |
240W | ||
AC-input | 3A maximum @ 100 VAC | |
50 to 60 Hz | ||
KVA rating1 | 0.240 KVA | |
Front, right, and left side in, rear out | ||
Standards Compliance |
|
|
Compliance | CE Marking | |
Safety | UL 19502, CSA-C22.2 No. 9503, EN 609504, IEC 9505, | |
EMI7 | FCC Class A (CFR 47, part 15)8, ICES-003 Class A9, EN55022 Class A, CISPR2210 Class A, AS/NZS 354811 Class A, | |
The console port is an RJ-45 receptacle. Data terminal ready (DTR) and data set ready (DSR) handshake signals are supported. The Request To Send (RTS) signal tracks the state of the Clear To Send (CTS) signal. Table A-2 lists the console port pinouts.
| Pin | Signal | Direction | Description |
|---|---|---|---|
11 | RTS/CTS | Output | Request to send / Clear to send |
2 | DTR | Output | Data terminal ready |
3 | TxD | Output | Transmit data |
4 | SGND | --- | Signal ground |
5 | SGND | --- | Signal ground |
6 | RxD | Input | Receive data |
7 | DSR | Input | Data set ready |
81 | RTS/CTS | Input | Request to send / Clear to send |
| 1Pin 1 and pin 8 are connected |
The Auxiliary port is an RJ-45 receptacle that supports remote console interfaces. Table A-3 lists the auxiliary port pinouts.
| Pin | Signal | Direction | Description |
|---|---|---|---|
1 | RTS | Output | Request to send |
2 | DTR | Output | Data terminal ready |
3 | TxD | Output | Transmit data |
4 | SGND | --- | Signal ground |
5 | SGND | --- | Signal ground |
6 | RxD | Input | Receive data |
7 | DSR | Input | Data set ready |
8 | CTS | Input | Clear to send |
Table A-4 provides cabling specifications for the Gigabit Interface Converters (GBICs) that you install into the Gigabit Ethernet port modules. Note that all GBIC ports have SC-type connectors, and the minimum cable distance for all GBICs listed is 6.5 feet (2 meters).
| GBIC | Wavelength (nm1) | Fiber Type | Core Size (micron) | Modal Bandwidth (MHz.km) | Cable Distance |
|---|---|---|---|---|---|
850 | MMF4
| 62.5 62.5 50.0 50.0 | 160 200 400 500 | 722 ft (220 m) 902 ft (275 m) 1640 ft (500 m) 1804 ft (550 m) | |
LX/LH5 | 1300 | MMF6
SMF7 (LX/LH) | 62.5 50.0 50.0 9/10 | 500 400 500 --- | 1804 ft (550 m) 1804 ft (550 m) 1804 ft (550 m) 32,810 ft (10 km) |
ZX8 | 1550 | SMF | Not conditional | --- | 70 to 100 km |
| 1nm = nanometers 2SX = short wavelength 3MMF only 4MMF = multimode fiber 5LX/LH = long wavelength/long haul 6Patch cord required (see the "Patch Cord" section for details) 7SMF = single-mode fiber 8ZX = extended distance |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Mar 24 09:24:39 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.