cc/td/doc/product/iaabu/pix/pix_v52
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

index

index

A


AAA message     2 - 13

access denied URL     2 - 26

ActiveX object, filtering     2 - 37

address translation slots     2 - 19, 2 - 37

ARP table     2 - 16

attacks
land.c     2 - 10
SYN     2 - 18

Authen Session End     2 - 15

authentication
failed     2 - 14
request succeeds     2 - 13

Auth from IP address/port to IP address/port failed     2 - 13

authorization
denied for user     2 - 14
denied from address     2 - 14

Auth start for user     2 - 13

B


beginning configuration replication     2 - 41

broadcast, invalid source address     2 - 10

built H245 connection     2 - 25

built inbound TCP connection     2 - 24

C


can not specify PAT host     2 - 10

commands
conduit     2 - 9, 2 - 11
conduit permit icmp     2 - 10
config     2 - 16
configure     2 - 17
failover     2 - 6
failover active     2 - 5
filter activex     2 - 37
filter allow     2 - 27
floodguard     2 - 14
global     2 - 9, 2 - 28
nat     2 - 9, 2 - 28
no failover     2 - 6
no failover active     2 - 5
outbound deny     2 - 8
reload     2 - 17
rsh     2 - 19
show arp     2 - 16
show blocks     2 - 7
show outbound     2 - 8
show static     2 - 18
show telnet     2 - 29
snmp-server     1 - 9
static     2 - 9
sysopt connection enforcesubnet     2 - 10
timeout uauth     2 - 15
write     2 - 16
write erase     2 - 16

conduit command     2 - 9, 2 - 11

conduit permit icmp command     2 - 10

config command     2 - 16

configure command     2 - 17

D


denied manager connection     2 - 30

denied Telnet login session     2 - 29

deny
inbound from outside     2 - 9
inbound ICMP     2 - 10
inbound UDP     2 - 9
inbound UDP due to query/response     2 - 9
IP from address to address     2 - 10
IP spoof     2 - 10
self route     2 - 9
TCP (no connection)     2 - 10

detecting use of Internet phone     2 - 25

DHCP client and server     2 - 39

DNS query or response is denied     2 - 9

DNS server too slow     2 - 9

dropping echo request     2 - 10

E


embryonic limit exceeded     2 - 18

end configuration--FAILED     2 - 16

End Configuration Replication     2 - 41

erase configuration     2 - 16

F


failover active command     2 - 5

failover command     2 - 6

failover messages     2 - 4, 2 - 6, 2 - 7, 2 - 41

filter activex command     2 - 37

filter allow command     2 - 27

filtering ActiveX objects     2 - 37

floodguard command     2 - 14

FTP data connection failed     2 - 19

G


global command     2 - 9, 2 - 28

H


H.245     2 - 25

H.323     2 - 25

hostile event     2 - 11, 2 - 35, 2 - 36

I


ICMP
packet denied     2 - 10
translation creation failed     2 - 28, 2 - 29

inbound TCP connection denied     2 - 8

insufficient memory     2 - 19, 2 - 37

interface, virtual     2 - 24

Internet phone, detecting use of     2 - 25

invalid character replaced in email address     2 - 13

invalid source addresses     2 - 10

L


Leaving ALLOW mode, URL Server     2 - 27

link status `Up' or 'Down'     2 - 7

log message variables     1 - 6

loopback network, invalid source address     2 - 10

lost failover communications with mate     2 - 7

M


memory, insufficient     2 - 19, 2 - 37

message block alloc failed     2 - 7

messages, how to read     1 - 6

monitoring on interface     2 - 6

MPPE     2 - 36

MS-CHAP     2 - 36

N


nat command     2 - 9, 2 - 28

no ARP for host     2 - 16

no associated connection within connection table     2 - 10

no authentication server found     2 - 13

nobody keyword in a message     1 - 3

no failover active command     2 - 5

no failover command     2 - 6

no translation group found     2 - 28

O


outbound deny command     2 - 8

out of address translation slots!     2 - 19

P


PAT
address     2 - 19, 2 - 37
global address     2 - 10, 2 - 28
host     2 - 10

permitted
manager connection     2 - 30
Telnet login session     2 - 29

PIX
clear finished     2 - 17
console enable password incorrect     2 - 30
reload command executed     2 - 17

PIX Firewall Manager message     2 - 16

portmapped translation, reclaimed     2 - 28

portmapped translation built for global address     2 - 28

power failure, failover     2 - 4

PPP virtual interface     2 - 24

PPTP tunnel     2 - 24

PPTP XGRE packet     2 - 35

preallocate H323 UDP backconnection     2 - 25

R


RADIUS authentication     2 - 36

RCMD, back connection failed     2 - 19

rebuilt TCP connection     2 - 26

Reducing link MTU     2 - 18

reload command     2 - 17

rsh command     2 - 19

S


security breach     2 - 9, 2 - 10

self route     2 - 9

severity levels definition     1 - 6

show arp command     2 - 16

show blocks command     2 - 7

show outbound command     2 - 8

show static command     2 - 18

show telnet command     2 - 29

SMTP     2 - 13

snmp-server command     1 - 9

SSH     2 - 32

static command     2 - 9

SYN     2 - 10

sysopt connection enforcesubnet command     2 - 10

T


TCP connection     2 - 24

TCP translation creation failed     2 - 28, 2 - 29

teardown
portmap translation     2 - 28
TCP connection     2 - 25
translation for IP address     2 - 28

Telnet     1 - 4, 1 - 9

Telnet login session failed     2 - 30

terminal monitor command     1 - 4

testing interface     2 - 7

timeout uauth command     2 - 15

too many connections on static     2 - 18

translation built for global address     2 - 28

tunnel, PPTP     2 - 24

U


UDP packet     2 - 9

UDP translation creation failed     2 - 28, 2 - 29

URL filtering, disabled     2 - 27

URL Server     2 - 27

V


variables in log messages     1 - 6

virtual interface     2 - 24

vpdn group command     2 - 36

W


Web requests, unfiltered     2 - 27

WebSENSE server     2 - 27

write command     2 - 16

write erase command     2 - 16

X


XGRE     2 - 35

hometocprevnextglossaryfeedbacksearchhelp
Posted: Fri Aug 25 13:37:17 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.