cc/td/doc/product/iaabu/pix/pix_v51
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

index

index

A


AAA message     2 - 10

access denied URL     2 - 23

ActiveX object, filtering     2 - 30

address translation slots     2 - 16

ARP table     2 - 12

attacks
land.c     2 - 8
SYN     2 - 15

Authen Session End     2 - 12

authentication
failed     2 - 11
request succeeds     2 - 10

Auth from IP address/port to IP address/port failed     2 - 10

authorization
denied for user     2 - 11
denied from address     2 - 11

Auth start for user     2 - 10

B


begin configuration     2 - 13

beginning configuration replication     2 - 32

broadcast, invalid source address     2 - 8

built H245 connection     2 - 21

built inbound TCP connection     2 - 21

C


can not specify PAT host     2 - 8

commands
conduit     2 - 7, 2 - 9
conduit permit icmp     2 - 8
config     2 - 13
configure     2 - 14
failover     2 - 4
failover active     2 - 3
filter activex     2 - 30
filter allow     2 - 24
floodguard     2 - 11
global     2 - 7, 2 - 25
nat     2 - 7, 2 - 25
no failover     2 - 4
no failover active     2 - 3
outbound deny     2 - 6
reload     2 - 14
rsh     2 - 16
show arp     2 - 12
show blocks     2 - 5
show link     2 - 17
show outbound     2 - 6
show static     2 - 15
show telnet     2 - 25
snmp-server     1 - 9
static     2 - 7
sysopt connection enforcesubnet     2 - 8
timeout uauth     2 - 12
write     2 - 13
write erase     2 - 13

conduit command     2 - 7, 2 - 9

conduit permit icmp command     2 - 8

config command     2 - 13

configure command     2 - 14

connection denied     2 - 7

D


denied manager connection     2 - 26

denied Telnet login session     2 - 25

deny
inbound from outside     2 - 7
inbound ICMP     2 - 8
inbound UDP     2 - 7
inbound UDP due to query/response     2 - 7
IP from address to address     2 - 8
IP spoof     2 - 8
self route     2 - 7
TCP (no connection)     2 - 8

detecting use of Internet phone     2 - 21

DNS query or response is denied     2 - 7

DNS server too slow     2 - 7

dropping echo request     2 - 8

E


embryonic limit exceeded     2 - 15

end configuration--FAILED     2 - 13

End Configuration Replication     2 - 33

erase configuration     2 - 13

ESP Error     2 - 17

F


failover active command     2 - 3

failover command     2 - 4

failover messages     2 - 1, 2 - 2, 2 - 4, 2 - 5, 2 - 32, 2 - 33

filter activex command     2 - 30

filter allow command     2 - 24

filtering ActiveX objects     2 - 30

floodguard command     2 - 11

FO replication failed     2 - 32

FO unreplicable     2 - 32

FTP data connection failed     2 - 15

G


global command     2 - 7, 2 - 25

H


H.245     2 - 21

H.323     2 - 21

hostile event     2 - 9, 2 - 28, 2 - 29

I


ICMP
packet denied     2 - 8
translation creation failed     2 - 25

inbound TCP connection denied     2 - 6

insufficient memory     2 - 16

interface, virtual     2 - 20

Internet phone, detecting use of     2 - 21

invalid character replaced in email address     2 - 10

invalid source addresses     2 - 8

K


keys, activate new     2 - 17

L


Leaving ALLOW mode, URL Server     2 - 24

link status `Up' or 'Down'     2 - 5

log message variables     1 - 6

loopback network, invalid source address     2 - 8

lost failover communications with mate     2 - 5

M


memory, insufficient     2 - 16

message block alloc failed     2 - 5

messages, how to read     1 - 6

monitoring on interface     2 - 4

MPPE     2 - 29

MS-CHAP     2 - 29

N


nat command     2 - 7, 2 - 25

no ARP for host     2 - 12

no associated connection within connection table     2 - 8

no authentication server found     2 - 10

nobody keyword in a message     1 - 3

no failover active command     2 - 3

no failover command     2 - 4

No Key SPI     2 - 17

no translation group found     2 - 25

O


outbound deny command     2 - 6

out of address translation slots!     2 - 16

P


PAT
address     2 - 16
global address     2 - 8, 2 - 24
host     2 - 8

permitted
manager connection     2 - 26
Telnet login session     2 - 25

PIX
clear finished     2 - 14
console enable password incorrect     2 - 26
reload command executed     2 - 14

PIX Firewall Manager message     2 - 13

portmapped translation, reclaimed     2 - 25

portmapped translation built for global address     2 - 24

power failure, failover     2 - 2

PPP virtual interface     2 - 20

PPTP tunnel     2 - 20

PPTP XGRE packet     2 - 28

preallocate H323 UDP backconnection     2 - 21

Private Link message     2 - 17

R


RADIUS authentication     2 - 29

RCMD, back connection failed     2 - 16

rebuilt TCP connection     2 - 22

Reducing link MTU     2 - 15

reload command     2 - 14

rsh command     2 - 16

S


security breach     2 - 7, 2 - 8

self route     2 - 7

severity levels definition     1 - 6

show arp command     2 - 12

show blocks command     2 - 5

show link command     2 - 17

show outbound command     2 - 6

show static command     2 - 15

show telnet command     2 - 25

SMTP     2 - 10

snmp-server command     1 - 9

static command     2 - 7

SYN     2 - 8

sysopt connection enforcesubnet command     2 - 8

T


TCP connection     2 - 21

TCP translation creation failed     2 - 25

teardown
portmap translation     2 - 25
TCP connection     2 - 21
translation for IP address     2 - 24

Telnet     1 - 4, 1 - 9

Telnet login session failed     2 - 26

terminal monitor command     1 - 4

testing interface     2 - 5

timeout uauth command     2 - 12

too many connections on static     2 - 15

translation built for global address     2 - 24

tunnel, PPTP     2 - 20

U


UDP packet     2 - 7

UDP translation creation failed     2 - 25

unable to allocate new UDP connections     2 - 16

URL filtering, disabled     2 - 24

URL Server     2 - 23

V


variables in log messages     1 - 6

virtual interface     2 - 20

vpdn group command     2 - 29

W


Web requests, unfiltered     2 - 24

WebSENSE server     2 - 23

write command     2 - 13

write erase command     2 - 13

X


XGRE     2 - 28

hometocprevnextglossaryfeedbacksearchhelp
Posted: Sun May 21 19:17:05 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.