This appendix provides in Table A-1 the technical specifications and regulatory agency approvals for the FastHub 400 series.
| Environmental Ranges |
| |
Operating temperature | 23 to 113ºF (-5 to 45ºC) | |
Storage temperature | -13 to 158ºF (-25 to 70ºC) | |
Operating humidity | 10 to 85% (noncondensing) | |
Operating altitude | Up to 9842 ft (3000 m) | |
| Power Requirements |
| |
90 to 127/200 to 250 VAC (autoranging) 50 to 60 Hz | ||
+5V | ||
40W | ||
| Physical Dimensions |
| |
7 lb (3.2 kg) | ||
1.73 x 17.5 x 8.25 in. (4.4 x 44.5 x 21 cm) | ||
| Agency Approvals |
| |
| Safety | EMI | |
AS/NZS 3260, TS001 | FCC Part 15 Class A | |
UL 1950/CSA 22.2 No. 950 | EN 55022A Class A (CISPR 22 Class A) | |
IEC 950/EN 60950 | VCCI Class A | |
CE | CE | |
| AS/NRZ 3548 Class A | |
![]()
![]()
![]()
![]()
![]()
![]()
![]()