The FastHub 108T/104T LEDs facilitate troubleshooting during ongoing operation. Table 4-1 lists the causes of common problems along with the recommended response.


Table  4-1: Problems and Recommended Responses
Symptom Possible Cause Corrective Action

Power LED does not come on

Power cord not connected Plug in both ends of the power cord
Other Contact Cisco or your authorized reseller

Link/Receive LED does not come on

No cable inserted Insert both ends of the cable into a device
Devices not powered Ensure both devices have power
Bad cable Replace cable with a known good one
Wrong cable type Verify cable selection (crossover vs. straight-through)

Disabled LED blinks

Device at other end malfunctioning Investigate device at other end of cable from the disabled FastHub 108T/104T port
Bad cable Replace cable with known good one