cc/td/doc/product/dsl_prod/c6130ni2
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Port Mapping

Port Mapping

This appendix provides port mapping tables that show wire pair and chassis port assignments for the following:

B.1 Installation with Siecor POTS Splitter Port Mapping Tables

Use Table B-1 through Table B-7 to map the following to Cisco 6130 NI-2 backplane receptacles J39 through J44 and the six Siecor back panel receptacles:

For an installation with a Siecor POTS splitter, you must connect the Cisco 6130 NI-2 DSLAM backplane receptacles and the Siecor POTS splitter back panel receptacles to single Cisco one-to-one Champ connector cables (see Table 3-2). The Cisco cable kit number is CAB-61-014 (see Table 3-2). The cable kit contains six Cisco one-to-one cables.

Figure B-1 shows a typical Cisco one-to-one cable.


Figure B-1: Typical Cisco 1-to-1 Connector Cable
 

Table B-1: Cisco 6130 NI-2 DSLAM Receptacle J39 to Siecor POTS Splitter Receptacle XDSL 9-32 Pinouts
J39/XDSL 9-32 Pins DSLAM Slot/Port System Port No. Tip/Ring J39/XDSL 9-32 Pins DSLAM Slot/Port System Port No. Tip/Ring

1

6/1

21

Tip

26

5/1

17

Ring

2

6/1

21

Ring

27

5/1

17

Tip

3

6/2

22

Tip

28

5/2

18

Ring

4

6/2

22

Ring

29

5/2

18

Tip

5

6/3

23

Tip

30

5/3

19

Ring

6

6/3

23

Ring

31

5/3

19

Tip

7

6/4

24

Tip

32

5/4

20

Ring

8

6/4

24

Ring

33

5/4

20

Tip

9

7/1

25

Tip

34

4/1

13

Ring

10

7/1

25

Ring

35

4/1

13

Tip

11

7/2

26

Tip

36

4/2

14

Ring

12

7/2

26

Ring

37

4/2

14

Tip

13

7/3

27

Tip

38

4/3

15

Ring

14

7/3

27

Ring

39

4/3

15

Tip

15

7/4

28

Tip

40

4/4

16

Ring

16

7/4

28

Ring

41

4/4

16

Tip

17

8/1

29

Tip

42

3/1

9

Ring

18

8/1

29

Ring

43

3/1

9

Tip

19

8/2

30

Tip

44

3/2

10

Ring

20

8/2

30

Ring

45

3/2

10

Tip

21

8/3

31

Tip

46

3/3

11

Ring

22

8/3

31

Ring

47

3/3

11

Tip

23

8/4

32

Tip

48

3/4

12

Ring

24

8/4

32

Ring

49

3/4

12

Tip

25

50


Table B-2: Cisco 6130 NI-2 DSLAM Receptacle J40 to Siecor POTS Splitter Receptacle XDSL 1-8, 65-72 Pinouts
J40/XDSL 1-8, 65-72 Pins DSLAM Slot/Port System Port No. Tip/Ring J40/XDSL 1-8, 65-72 Pin DSLAM Slot/Port System Port No. Tip/Ring

1

22/1

69

Tip

26

21/1

65

Ring

2

22/1

69

Ring

27

21/1

65

Tip

3

22/2

70

Tip

28

21/2

66

Ring

4

22/2

70

Ring

29

21/2

66

Tip

5

22/3

71

Tip

30

21/3

67

Ring

6

22/3

71

Ring

31

21/3

67

Tip

7

22/4

72

Tip

32

21/4

68

Ring

8

22/4

72

Ring

33

21/4

68

Tip

9

Tip

34

2/1

5

Ring

10

Ring

35

2/1

5

Tip

1

Tip

36

2/2

6

Ring

12

Ring

37

2/2

6

Tip

13

Tip

38

2/3

7

Ring

14

Ring

39

2/3

7

Tip

15

Tip

40

2/4

8

Ring

16

Ring

41

2/4

8

Tip

17

Tip

42

1/1

1

Ring

18

Ring

43

1/1

1

Tip

19

Tip

44

1/2

2

Ring

20

Ring

45

1/2

2

Tip

21

Tip

46

1/3

3

Ring

22

Ring

47

1/3

3

Tip

23

Tip

48

1/4

4

Ring

24

Ring

49

1/4

4

Tip

25

50


Table B-3: Cisco 6130 NI-2 DSLAM Receptacle J42 to POTS Splitter Receptacle XDSL 73-96 Pinouts
J41/XDSL 73-96 Pins DSLAM Slot/Port System Port No. Tip/Ring J41/XDSL 73-96 Pins DSLAM Slot/Port System Port No. Tip/Ring

1

26/1

85

Tip

26

25/1

81

Ring

2

26/1

85

Ring

27

25/1

81

Tip

3

26/2

86

Tip

28

25/2

82

Ring

4

26/2

86

Ring

29

25/2

82

Tip

5

26/3

87

Tip

30

25/3

83

Ring

6

26/3

87

Ring

31

25/3

83

Tip

7

26/4

88

Tip

32

25/4

84

Ring

8

26/4

88

Ring

33

25/4

84

Tip

9

27/1

89

Tip

34

24/1

77

Ring

10

27/1

89

Ring

35

24/1

77

Tip

11

27/2

90

Tip

36

24/2

78

Ring

12

27/2

90

Ring

37

24/2

78

Tip

13

27/3

91

Tip

38

24/3

79

Ring

14

27/3

91

Ring

39

24/3

79

Tip

15

27/4

92

Tip

40

24/4

80

Ring

16

27/4

92

Ring

41

24/4

80

Tip

17

28/1

93

Tip

42

23/1

73

Ring

18

28/1

93

Ring

43

23/1

73

Tip

19

28/2

94

Tip

44

23/2

74

Ring

20

28/2

94

Ring

45

23/2

74

Tip

21

28/3

95

Tip

46

23/3

75

Ring

22

28/3

95

Ring

47

23/3

75

Tip

23

28/4

96

Tip

48

23/4

76

Ring

24

28/4

96

Ring

49

23/4

76

Tip

25

50


Table B-4: Cisco 6130 NI-2 DSLAM Receptacle J42 to POTS Splitter Receptacle XDSL 33-56 Pinouts
J42/XDSL 33-56 Pins DSLAM Slot/Port System Port No Tip/Ring J42/XDSL 33-56 Pins DSLAM Slot/Port System Port No. Tip/Ring

1

17/1

49

Tip

26

16/1

45

Ring

2

17/1

49

Ring

27

16/1

45

Tip

3

17/2

50

Tip

28

16/2

46

Ring

4

17/2

50

Ring

29

16/2

46

Tip

5

17/3

51

Tip

30

16/3

47

Ring

6

17/3

51

Ring

31

16/3

47

Tip

7

17/4

52

Tip

32

16/4

48

Ring

8

17/4

52

Ring

33

16/4

48

Tip

9

18/1

53

Tip

34

15/1

41

Ring

10

18/1

53

Ring

35

15/1

41

Tip

11

18/2

54

Tip

36

15/2

42

Ring

12

18/2

54

Ring

37

15/2

42

Tip

13

18/3

55

Tip

38

15/3

43

Ring

14

18/3

55

Ring

39

15/3

43

Tip

15

18/4

56

Tip

40

15/4

44

Ring

16

18/4

56

Ring

41

15/4

44

Tip

17

13/1

33

Tip

42

14/1

37

Ring

18

13/1

33

Ring

43

14/1

37

Tip

19

13/2

34

Tip

44

14/2

38

Ring

20

13/2

34

Ring

45

14/2

38

Tip

21

13/3

35

Tip

46

14/3

39

Ring

22

13/3

35

Ring

47

14/3

39

Tip

23

13/4

36

Tip

48

14/4

40

Ring

24

13/4

36

Ring

49

14/4

40

Tip

25

50


Table B-5: Cisco 6130 NI-2 DSLAM Receptacle J42 to POTS Splitter Receptacle XDSL 57-64, 121-128 Pinouts
J43/XDSL 57-64, 121-128 Pins DSLAM Slot/Port System Port No. Tip/Ring 43/XDSL 57-64, 121-128Pins DSLAM Slot/Port System Port No. Tip/Ring

1

20/1

61

Tip

26

19/1

57

Ring

2

20/1

61

Ring

27

19/1

57

Tip

3

20/2

62

Tip

28

19/2

58

Ring

4

20/2

62

Ring

29

19/2

58

Tip

5

20/3

63

Tip

30

19/3

59

Ring

6

20/3

63

Ring

31

19/3

59

Tip

7

20/4

64

Tip

32

19/4

60

Ring

8

20/4

64

Ring

33

19/4

60

Tip

9

Tip

34

38/1

125

Ring

10

Ring

35

38/1

125

Tip

11

Tip

36

38/2

126

Ring

12

Ring

37

38/2

126

Tip

13

Tip

38

38/3

127

Ring

14

Ring

39

38/3

127

Tip

15

Tip

40

38/4

128

Ring

16

Ring

41

38/4

128

Tip

17

Tip

42

37/1

121

Ring

18

Ring

43

37/1

121

Tip

19

Tip

44

37/2

122

Ring

20

Ring

45

37/2

122

Tip

21

Tip

46

37/3

123

Ring

22

Ring

47

37/3

123

Tip

23

Tip

48

37/4

124

Ring

24

Ring

49

37/4

124

Tip

25

50


Table B-6: Cisco 6130 NI-2 DSLAM Receptacle J43 to POTS Splitter Receptacle XDSL 57-64, 121-128 Pinouts
J43/XDSL 57-64, 121-128 Pins DSLAM Slot/Port System Port No. Tip/Ring J43/XDSL 57-64, 121-128 Pins DSLAM Slot/Port System Port No. Tip/Ring

1

20/1

61

Tip

26

19/1

57

Ring

2

20/1

61

Ring

27

19/1

57

Tip

3

20/2

62

Tip

28

19/2

58

Ring

4

20/2

62

Ring

29

19/2

58

Tip

5

20/3

63

Tip

30

19/3

59

Ring

6

20/3

63

Ring

31

19/3

59

Tip

7

20/4

64

Tip

32

19/4

60

Ring

8

20/4

64

Ring

33

19/4

60

Tip

9

Tip

34

38/1

125

Ring

10

Ring

35

38/1

125

Tip

11

Tip

36

38/2

126

Ring

12

Ring

37

38/2

126

Tip

13

Tip

38

38/3

127

Ring

14

Ring

39

38/3

127

Tip

15

Tip

40

38/4

128

Ring

16

Ring

41

38/4

128

Tip

17

Tip

42

37/1

121

Ring

18

Ring

43

37/1

121

Tip

19

Tip

44

37/2

122

Ring

20

Ring

45

37/2

122

Tip

21

Tip

46

37/3

123

Ring

22

Ring

47

37/3

123

Tip

23

Tip

48

37/4

124

Ring

24

Ring

49

37/4

124

Tip

25

50


Table B-7: Cisco 6130 NI-2 DSLAM Receptacle J44 to POTS Splitter Receptacle XDSL 97-120 Pinouts
J44/XDSL 97-120 Pins DSLAM Slot/Port System Port No. Tip/Ring J44/XDSL 97-120 Pins DSLAM Slot/Port System Port No. Tip/Ring

1

35/1

113

Tip

26

34/1

109

Ring

2

35/1

113

Ring

27

34/1

109

Tip

3

35/2

114

Tip

28

34/2

110

Ring

4

35/2

114

Ring

29

34/2

110

Tip

5

35/3

115

Tip

30

34/3

111

Ring

6

35/3

115

Ring

31

34/3

111

Tip

7

35/4

116

Tip

32

34/4

112

Ring

8

35/4

116

Ring

33

34/4

112

Tip

9

36/1

117

Tip

34

33/1

105

Ring

10

36/1

117

Ring

35

33/1

105

Tip

11

36/2

118

Tip

36

33/2

106

Ring

12

36/2

118

Ring

37

33/2

106

Tip

13

36/3

119

Tip

38

33/3

107

Ring

14

36/3

119

Ring

39

33/3

107

Tip

15

36/4

120

Tip

40

33/4

108

Ring

16

36/4

120

Ring

41

33/4

108

Tip

17

31/

97

Tip

42

32/1

101

Ring

18

31/1

97

Ring

43

32/1

101

Tip

19

31/2

98

Tip

44

32/2

102

Ring

20

31/2

98

Ring

45

32/2

102

Tip

21

31/3

99

Tip

46

32/3

103

Ring

22

31/3

99

Ring

47

32/3

103

Tip

23

31/4

100

Tip

48

32/4

104

Ring

24

31/4

100

Ring

49

32/4

104

Tip

25

50

B.2 Installation without POTS Splitter Port Mapping

For an installation without a Siecor POTS splitter, use a pair of Cisco three-to-three connector cables. The corresponding Cisco cable kit number is CAB-MC128-MDF. The cable kit contains a left and a right three-to-three Cisco cable to connect the Cisco 6130 NI-2 DSLAM to the MDF for systems using quad-port DMT-2 ATUC-1-4DMT line modules. Figure B-2 shows the Cisco three-to-three connector cables. Table B-8 shows port mapping for these cables.


Figure B-2: Cisco Three-to-Three Connector Cables


Table B-8: Port Mapping for 3-to-3 Connector Cables in an Installation Without a POTS Splitter
MC Slot/Line Champ Pins Cable Connector/
Cable Part Number
Tip Ring

1/1

1

26

Connector P4/
Cable 72-1765-01

1/2

2

27

1/3

3

28

1/4

4

29

2/1

5

30

2/2

6

31

2/3

7

32

2/4

8

33

3/1

9

34

3/2

10

35

3/3

11

36

3/4

12

37

4/1

13

38

4/2

14

39

4/3

15

40

4/4

16

41

5/1

17

42

5/2

18

43

5/3

19

44

5/4

20

45

6/1

21

46

6/2

22

47

6/3

23

48

6/4

24

49

7/1

1

26

Connector P5/
Cable 72-1765-01

7/2

2

27

7/3

3

28

7/4

4

29

8/1

5

30

8/2

6

31

8/3

7

32

8/4

8

33

13/1

1

26

Connector P1/
Cable 72-1720-01

13/2

2

27

13/3

3

28

13/4

4

29

14/1

5

30

14/2

6

31

14/3

7

32

14/4

8

33

15/1

9

34

15/2

10

35

15/3

11

36

15/4

12

37

16/1

13

38

16/2

14

39

16/3

15

40

16/4

16

41

17/1

17

42

17/2

18

43

17/3

19

44

17/4

20

45

18/1

21

46

18/2

22

47

18/3

23

48

18/4

24

49

19/1

1

26

Connector P2/
Cable 72-1720-01

19/2

2

27

19/3

3

28

19/4

4

29

20/1

5

30

20/2

6

31

20/3

7

32

20/4

8

33

21/1

9

34

Connector P5/
Cable 72-1765-01

21/2

10

35

21/3

11

36

21/4

12

37

22/1

13

38

22/2

14

39

22/3

15

40

22/4

16

41

23/1

17

42

23/2

18

43

23/3

19

44

23/4

20

45

24/1

21

46

24/2

22

47

24/3

23

48

24/4

24

49

25/1

1

26

Connector P6/
Cable 72-1765-01

25/2

2

27

25/3

3

28

25/4

4

29

26/1

5

30

26/2

6

31

26/3

7

32

26/4

8

33

27/1

9

34

27/2

10

35

27/3

11

36

27/4

12

37

28/1

13

38

28/2

14

39

28/3

15

40

28/4

16

41

31/1

9

34

Connector P2/
Cable 72-1720-01

31/2

10

35

31/3

11

36

31/4

12

37

32/1

13

38

32/2

14

39

32/3

15

40

32/4

16

41

33/1

17

42

33/2

18

43

33/3

19

44

33/4

20

45

34/1

21

46

34/2

22

47

34/3

23

48

34/4

24

49

35/1

1

26

Connector P3/
Cable 72-1720-01

35/2

2

27

35/3

3

28

35/4

4

29

36/1

5

30

36/2

6

31

36/3

7

32

36/4

8

33

37/1

9

34

37/2

10

35

37/3

11

36

37/4

12

37

38/1

13

38

38/2

14

39

38/3

15

40

38/4

16

41

S


hometocprevnextglossaryfeedbacksearchhelp
Posted: Mon Mar 6 06:57:33 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.