This appendix provides cabling guidelines, cabling configuration diagrams, part numbers, and port mapping tables for the following configurations:
Cisco used a standard telco color chart when designing the cables for the Cisco 6130 with NI-2 system connections. This appendix includes a standard telco color chart.
![]() |
Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. |
![]() |
Note For port mapping tables to build your own Cisco 6130 cables, see Table B-13. |
Table B-1 shows an overview of the cables used for each Cisco 6130 with NI-2 system configuration.
| Configuration | Connection | Cable Type | Ports | Line Coding Technology | Reference | ||
|---|---|---|---|---|---|---|---|
| Cisco 6130 | POTS Splitter | Table | Figure | ||||
Direct Connect with a POTS splitter | Cisco 6130 to two Cisco 6120 chassis | One-to-two | 128 | 64 each POTS splitter | Figure B-2 and Figure B-3 | ||
Third-party POTS splitter to Cisco 6130 | One-to-one | 128 | 128 | DMT-2 (ADSL) | |||
POTS splitter to MDF1 | One-to-one | -- | 80 | CAP (ADSL) or DMT-2 (ADSL) | Figure B-5, Figure B-6, and Figure B-7 | ||
Two-to-two | -- | 80 | CAP (ADSL) or DMT-2 (ADSL) | Figure B-8, Figure B-9, and Figure B-10 | |||
Direct Connect without a POTS splitter | Cisco 6130 to MDF | Three-to-three | 128 | -- | DMT-2 (ADSL) | ||
Intermixing |
| One-to-one | 96 | 64 | DMT-2 (ADSL) | ||
| One-to-one | 96 | 128 | CAP (ADSL) or DMT-2 (ADSL) | -- | ||
| 1MDF = main distribution frame 2SDSL = symmetrical digital subscriber line |
You need to ensure that all cables are screwed in to the backplane and that the Champ connectors are tie wrapped. (See Figure B-1.)

In a Direct Connect with a POTS splitter configuration, use only designated cables to connect the Cisco 6130, the POTS splitter, and the MDF. This section provides tables and illustrations for the following cables:
![]() |
Note Some chassis connectors in the cabling diagrams are not used because they are specific to one of the other configurations of the Cisco 6130 with NI-2 system or because they are reserved for future use. |
You can use one-to-two cables to connect one Cisco 6130 to two Cisco 6120 chassis for systems using quad-port xTU-C line cards.
Table B-2 lists the backplane connectors and the part numbers for the one-to-two cables. In this configuration, 64 POTS splitter ports are used in each Cisco 6120, for a total of 128 ports.
| Backplane Connector | Cisco Part Number | |||||
|---|---|---|---|---|---|---|
| Cisco 6130 | First Cisco 6120 Connector | Second Cisco 6120 Connector | Kit | Subassembly | ||
| Backplane | Cable | Backplane | Cable | |||
J39 | J3 | P3A | J3 | P3B | CAB-MC128-PSC80 | 72-1767-011 |
J40 | J1 | P1A | J1 | P1B | CAB-MC128-PSC80 | 72-1767-01 |
J41 | J5 | P5A | J5 | P5B | CAB-MC128-PSC80 | 72-1767-01 |
J42 | J4 | P4A | J4 | P4B | CAB-MC128-PSC80 | 72-1768-012 |
J43 | J2 | P2A | J2 | P2B | CAB-MC128-PSC80 | 72-1769-013 |
J44 | J6 | P6A | J6 | P6B | CAB-MC128-PSC80 | 72-1770-014 |
![]() |
Note When you use the one-to-two cable, see Table B-9 for port mapping information. |
Figure B-2 shows the one-to-two cable.

![]() |
Tips If you use 64 POTS splitter ports, tie wrap the second Cisco 6120 connector to the rack. When you expand your system to 128 POTS splitter ports, the second Cisco 6120 connector will attach to a second Cisco 6120. |
Figure B-3 shows the cabling between one Cisco 6130 and two Cisco 6120 chassis in which the cables listed in Table B-2 are used.

Use the one-to-one cable when you are connecting the Cisco 6130 to the third-party POTS splitter. Table B-3 lists the cable and associated part numbers.
| Backplane Connector | Cisco Part Number | ||
|---|---|---|---|
| Cisco 6130 | Third-Party POTS Splitter | Kit | Subassembly |
J39 | xDSL | CAB-6121-1 | 72-1766-01 |
J40 | xDSL | CAB-6121-1 | 72-1766-01 |
J41 | xDSL | CAB-6121-1 | 72-1766-01 |
J42 | xDSL | CAB-6121-1 | 72-1766-01 |
J43 | xDSL | CAB-6121-1 | 72-1766-01 |
J44 | xDSL | CAB-6121-1 | 72-1766-01 |
![]() |
Note When you use the one-to-one cable, see Table B-10 for port mapping information. |
Figure B-4 shows the one-to-one special cable.

![]() |
Note If you are installing a Direct Connect with a POTS splitter configuration using the third-party POTS splitter, install the Cisco components (excluding the POTS splitter) according to "Installing a Direct Connect Without a POTS Splitter Configuration." Refer to the appropriate vendor documentation for installation procedures for the third-party POTS splitter. |
You can use the following cables to connect the POTS splitter (Cisco 6120 or third-party POTS splitter) to the MDF in a Direct Connect with a POTS splitter configuration:
![]() |
Note Refer to the appropriate vendor documentation for cabling connectors and procedures for the third-party POTS splitter. |
You can use one-to-one cables to connect the Cisco 6120 to the MDF or POTS service connectors. Table B-4 lists the backplane connectors, the available cable lengths, and the part numbers for the one-to-one cables. Each cable has the same pinouts. The only difference between the four cables is the length. Use the length that works best for your configuration.
| Backplane Connector | Cisco Part Number | ||
|---|---|---|---|
| Cisco 6120 | MDF Modem | Kit | Subassembly |
| MDF Connectors | |||
J11, J12, J13, J14 | P1 (modems 1 to 16), | CAB-61-015 | 72-1599-01 |
CAB-61-016 | 72-1598-01 | ||
CAB-61-017 | 72-1597-01 | ||
CAB-61-018 | 72-1596-01 | ||
| POTS Connectors | |||
J7, J8, J9, J10 | P1 (modems 1 to 16), | CAB-61-015 | 72-1599-01 |
CAB-61-016 | 72-1598-01 | ||
CAB-61-017 | 72-1597-01 | ||
CAB-61-018 | 72-1596-01 | ||
Figure B-5 shows the one-to-one cable.

Figure B-6 shows the cabling between the Cisco 6120 to the MDF in which the cables listed in Table B-4 are used.

Figure B-7 shows the cabling between the Cisco 6120 to the POTS service connections in which the cables listed in Table B-4 are used.

![]() |
Note Refer to the appropriate vendor documentation for cabling connectors and procedures for the third-party POTS splitter. |
To associate the Cisco 6120 MDF or POTS wire pairs and the Cisco 6130 modem ports, the two-to-two cable remaps the wire pairs from the Cisco 6120 MDF or POTS connectors to the Cisco 6120 connectors. You can use the two-to-two cable to
Table B-5 lists the backplane connectors and the part numbers for the two-to-two cables connecting the Cisco 6120 to the MDF in a Direct Connect with a POTS splitter configuration.
| Backplane Connector | Cisco Part Number | ||
|---|---|---|---|
| Cisco 6120 | MDF Modem | Kit | Subassembly |
| xDSL Subscriber Line Connectors | |||
J11, J12 | P1 (modems 1 to 16) or | CAB-PSC-80-REPIN | 72-1716-01 |
J13, J14 | P2 (modems 17 to 32) or P4 (modems 49 to 64) | CAB-PSC-80-REPIN | 72-1772-01 |
| Voice Line Connectors | |||
J7, J9 | P1 (modems 1 to 16) or | CAB-PSC-80-REPIN | 72-1716-01 |
J8, J10 | P2 (modems 17 to 32) or P4 (modems 49 to 64) | CAB-PSC-80-REPIN | 72-1772-01 |
![]() |
Note When you use the two-to-two cable, see Table B-11 for port mapping information. |
Figure B-8 shows the two-to-two cable.

Figure B-9 shows the cabling between the xDSL subscriber line connectors on the Cisco 6120 and the MDF in which the cables listed in Table B-5 are used.

Figure B-10 shows the cabling between the voice lines on the Cisco 6120 and the voice-switching equipment that provides local POTS service. The cables listed in Table B-5 are used for the connection.

In a Direct Connect without a POTS splitter configuration, use only designated cables to connect the Cisco 6130 and the MDF.
![]() |
Note Some chassis connectors in the cabling diagrams are not used because they are specific to one of the other configurations of the Cisco 6130 with NI-2 system or because they are reserved for future use. |
To associate the MDF wire pairs and the Cisco 6130 modem ports, the three-to-three cable remaps the wire pairs from the Cisco 6130 connectors to the MDF connectors. Use the cable in systems with quad-port xTU-C modules installed in the chassis. Table B-6 lists the backplane connectors and the part numbers for the three-to-three cables connecting the Cisco 6130 to the MDF in a Direct Connect without a POTS splitter configuration.
| Backplane Connector | Cisco Part Number | ||
|---|---|---|---|
| Cisco 6130 | MDF | Kit | Subassembly |
J39, J40, J41 | P4 (slots 1 to 6), | CAB-MC128-MDF | 72-1765-01 |
J42, J43, J44 | P1 (slots 13 to 18), | CAB-MC128-MDF | 72-1720-01 |
![]() |
Note When you use the three-to-three cable, see Table B-12 for port mapping information. |
Figure B-11 shows the three-to-three cable.

Figure B-12 shows the cabling between the Cisco 6130 and the MDF in which the cables listed in Table B-6 are used.

Use intermixing cables when you want to configure half of the Cisco 6130 chassis with ADSL (Direct Connect with a POTS splitter configuration) and the other half of the chassis with SDSL (Direct Connect without a POTS splitter configuration). This section provides tables and illustrations for the following cables:
Use CAB-64-mix cable set when you install dual-port DMT-2 ATU-C modules in slots 1 through 8 and slots 21 through 28 and STU-C modules in slots 13 through 20 and slots 31 through 38. Table B-7 lists the backplane connectors and the part numbers for the CAB-64-mix cable set.
| Backplane Connector | Cisco Part Number | NetSpeed Part Number | |||
|---|---|---|---|---|---|
| Cisco 6130 | Cisco 6120 | MDF | Kit | Subassembly | |
J39 | J3 | -- | CAB-64-mix | 72-1665-01 | 4100-021-01 |
J40 | J1 | -- | CAB-64-mix | 72-1665-01 | 4100-021-01 |
J41 | J5 | -- | CAB-64-mix | 72-1665-01 | 4100-021-01 |
J42, J43, J44 | -- | P1 (slots 13 to 18), | CAB-64-mix | -- | 72-1720-01 |
Figure B-13 shows the cabling between the Cisco 6130, the Cisco 6120, and the MDF in which the cables listed in Table B-7 are used.

Use CAB-128-mix cable set when you install quad-port flexi ATU-C modules in slots 1 through 8 and slots 21 through 28 and STU-C modules in slots 13 through 20 and slots 31 through 38. Table B-8 lists the backplane connectors and the part numbers for the CAB-128-mix cable set.
| Backplane Connector | Cisco Part Number | |||
|---|---|---|---|---|
| Cisco 6130 | Third-Party POTS Splitter | MDF | Kit | Subassembly |
J39 | xDSL | -- | CAB-128-mix | 72-1766-01 |
J40 | xDSL | -- | CAB-128-mix | 72-1766-01 |
J41 | xDSL | -- | CAB-128-mix | 72-1766-01 |
J42, J43, J44 | -- | P1 (slots 13 to 18), | CAB-128-mix | 72-1720-01 |
![]() |
Note See the left side of Figure B-12 for the Cisco 6130 cable connections for the J42, J43, and J44 connectors. Refer to the appropriate vendor documentation for cabling connectors and procedures for the third-party POTS splitter. |
This section provides port mapping tables which show the wire pair and chassis port assignments for the following configurations and cables:
Table B-9 maps the Cisco 6130 ports, the Cisco 6120 ports for two Cisco 6120 chassis, and the wire pairs when using the one-to-two cables (see Table B-2) for a Direct Connect with a POTS splitter configuration. The corresponding cable kit number is CAB-MC128-PSC80. You can use the one-to-two cables to connect one Cisco 6130 to two Cisco 6120 chassis for systems using quad-port ATU-C modules.
| Cisco 6130 Slot/Line | Cisco 6120 Slot/Line | Champ Pins | Cisco 6120 MDF/ POTS Connection | ||
|---|---|---|---|---|---|
| Cisco 6120 Chassis 1 | Cisco 6120 Chassis 2 | Tip | Ring | ||
1/1 | 1/1 | -- | 9 | 34 | J11/J7 |
1/2 | 1/2 | -- | 10 | 35 | |
1/3 | -- | 1/1 | 9 | 34 | |
1/4 | -- | 1/2 | 10 | 35 | |
2/1 | 1/3 | -- | 11 | 36 | |
2/2 | 1/4 | -- | 12 | 37 | |
2/3 | -- | 1/3 | 11 | 36 | |
2/4 | -- | 1/4 | 12 | 37 | |
3/1 | 2/1 | -- | 5 | 30 | |
3/2 | 2/2 | -- | 6 | 31 | |
3/3 | -- | 2/1 | 5 | 30 | |
3/4 | -- | 2/2 | 6 | 31 | |
4/1 | 2/3 | -- | 7 | 32 | |
4/2 | 2/4 | -- | 8 | 33 | |
4/3 | -- | 2/3 | 7 | 32 | |
4/4 | -- | 2/4 | 8 | 33 | |
5/1 | 3/1 | -- | 1 | 26 | |
5/2 | 3/2 | -- | 2 | 27 | |
5/3 | -- | 3/1 | 1 | 26 | |
5/4 | -- | 3/2 | 2 | 27 | |
6/1 | 3/3 | -- | 3 | 28 | |
6/2 | 3/4 | -- | 4 | 29 | |
6/3 | -- | 3/3 | 3 | 28 | |
6/4 | -- | 3/4 | 4 | 29 | |
7/1 | 4/1 | -- | 18 | 43 | |
7/2 | 4/2 | -- | 19 | 44 | |
7/3 | -- | 4/1 | 18 | 43 | |
7/4 | -- | 4/2 | 19 | 44 | |
8/1 | 4/3 | -- | 20 | 45 | |
8/2 | 4/4 | -- | 21 | 46 | |
8/3 | -- | 4/3 | 20 | 45 | |
8/4 | -- | 4/4 | 21 | 46 | |
13/1 | 19/1 | -- | 18 | 43 | J14/J8 |
13/2 | 19/2 | -- | 19 | 44 | |
13/3 | -- | 19/1 | 18 | 43 | |
13/4 | -- | 19/2 | 19 | 44 | |
14/1 | 19/3 | -- | 20 | 45 | |
14/2 | 19/4 | -- | 21 | 46 | |
14/3 | -- | 19/3 | 20 | 45 | |
14/4 | -- | 19/4 | 21 | 46 | |
15/1 | 20/1 | -- | 1 | 26 | |
15/2 | 20/2 | -- | 2 | 27 | |
15/3 | -- | 20/1 | 1 | 26 | |
15/4 | -- | 20/2 | 2 | 27 | |
16/1 | 20/3 | -- | 3 | 28 | |
16/2 | 20/4 | -- | 4 | 29 | |
16/3 | -- | 20/3 | 3 | 28 | |
16/4 | -- | 20/4 | 4 | 29 | |
17/1 | 21/1 | -- | 5 | 30 | |
17/2 | 21/2 | -- | 6 | 31 | |
17/3 | -- | 21/1 | 5 | 30 | |
17/4 | -- | 21/2 | 6 | 31 | |
18/1 | 21/3 | -- | 7 | 32 | |
18/2 | 21/4 | -- | 8 | 33 | |
18/3 | -- | 21/3 | 7 | 32 | |
18/4 | -- | 21/4 | 8 | 33 | |
19/1 | 22/1 | -- | 9 | 34 | |
19/2 | 22/2 | -- | 10 | 35 | |
19/3 | -- | 22/1 | 9 | 34 | |
19/4 | -- | 22/2 | 10 | 35 | |
20/1 | 22/3 | -- | 11 | 36 | |
20/2 | 22/4 | -- | 12 | 37 | |
20/3 | -- | 22/3 | 11 | 36 | |
20/4 | -- | 22/4 | 12 | 37 | |
21/1 | 5/1 | -- | 22 | 47 | J11/J7 |
21/2 | 5/2 | -- | 23 | 48 | |
21/3 | -- | 5/1 | 22 | 47 | |
21/4 | -- | 5/2 | 23 | 48 | |
22/1 | 5/3 | -- | 24 | 49 | |
22/2 | 5/4 | -- | 25 | 50 | |
22/3 | -- | 5/3 | 24 | 49 | |
22/4 | -- | 5/4 | 25 | 50 | |
23/1 | 6/1 | -- | 6 | 31 | J12/J9 |
23/2 | 6/2 | -- | 7 | 32 | |
23/3 | -- | 6/1 | 6 | 31 | |
23/4 | -- | 6/2 | 7 | 32 | |
24/1 | 6/3 | -- | 8 | 33 | |
24/2 | 6/4 | -- | 9 | 34 | |
24/3 | -- | 6/3 | 8 | 33 | |
24/4 | -- | 6/4 | 9 | 34 | |
25/1 | 7/1 | -- | 2 | 27 | |
25/2 | 7/2 | -- | 3 | 28 | |
25/3 | -- | 7/1 | 2 | 27 | |
25/4 | -- | 7/2 | 3 | 28 | |
26/1 | 7/3 | -- | 4 | 29 | |
26/2 | 7/4 | -- | 5 | 30 | |
26/3 | -- | 7/3 | 4 | 29 | |
26/4 | -- | 7/4 | 5 | 30 | |
27/1 | 8/1 | -- | 1 | 26 | |
27/2 | 8/2 | -- | 10 | 35 | |
27/3 | -- | 8/1 | 1 | 26 | |
27/4 | -- | 8/2 | 10 | 35 | |
28/1 | 8/3 | -- | 11 | 36 | |
28/2 | 8/4 | -- | 12 | 37 | |
28/3 | -- | 8/3 | 11 | 36 | |
28/4 | -- | 8/4 | 12 | 37 | |
31/1 | 15/1 | -- | 1 | 26 | J13/J10 |
31/2 | 15/2 | -- | 10 | 35 | |
31/3 | -- | 15/1 | 1 | 26 | |
31/4 | -- | 15/2 | 10 | 35 | |
32/1 | 15/3 | -- | 11 | 36 | |
32/2 | 15/4 | -- | 12 | 37 | |
32/3 | -- | 15/3 | 11 | 36 | |
32/4 | -- | 15/4 | 12 | 37 | |
33/1 | 16/1 | -- | 2 | 27 | |
33/2 | 16/2 | -- | 3 | 28 | |
33/3 | -- | 16/1 | 2 | 27 | |
33/4 | -- | 16/2 | 3 | 28 | |
34/1 | 16/3 | -- | 4 | 29 | |
34/2 | 16/4 | -- | 5 | 30 | |
34/3 | -- | 16/3 | 4 | 29 | |
34/4 | -- | 16/4 | 5 | 30 | |
35/1 | 17/1 | -- | 6 | 31 | |
35/2 | 17/2 | -- | 7 | 32 | |
35/3 | -- | 17/1 | 6 | 31 | |
35/4 | -- | 17/2 | 7 | 32 | |
36/1 | 17/3 | -- | 8 | 33 | |
36/2 | 17/4 | -- | 9 | 34 | |
36/3 | -- | 17/3 | 8 | 33 | |
36/4 | -- | 17/4 | 9 | 34 | |
37/1 | 18/1 | -- | 22 | 47 | J14/J8 |
37/2 | 18/2 | -- | 23 | 48 | |
37/3 | -- | 18/1 | 22 | 47 | |
37/4 | -- | 18/2 | 23 | 48 | |
38/1 | 18/3 | -- | 24 | 49 | |
38/2 | 18/4 | -- | 25 | 50 | |
38/3 | -- | 18/3 | 24 | 49 | |
38/4 | -- | 18/4 | 25 | 50 | |
Table B-10 maps the Cisco 6130 ports, the POTS splitter ports, and the wire pairs when using the one-to-one cables (see Table B-3) when a third-party POTS splitter is installed in your configuration. The corresponding cable kit number is CAB-6121-1.
| Cisco 6130 Slot/Line | POTS Splitter Slot/Line | Champ Pins | POTS Splitter Connection | |
|---|---|---|---|---|
| Tip | Ring | |||
1/1 | 1/1 | 26 | 1 | Line 1 to 24 or POTS 1 to 24 |
1/2 | 1/2 | 27 | 2 | |
1/3 | 1/3 | 28 | 3 | |
1/4 | 1/4 | 29 | 4 | |
2/1 | 1/5 | 30 | 5 | |
2/2 | 1/6 | 31 | 6 | |
2/3 | 1/7 | 32 | 7 | |
2/4 | 1/8 | 33 | 8 | |
3/1 | 2/1 | 34 | 9 | |
3/2 | 2/2 | 35 | 10 | |
3/3 | 2/3 | 36 | 11 | |
3/4 | 2/4 | 37 | 12 | |
4/1 | 2/5 | 38 | 13 | |
4/2 | 2/6 | 39 | 14 | |
4/3 | 2/7 | 40 | 15 | |
4/4 | 2/8 | 41 | 16 | |
5/1 | 3/1 | 42 | 17 | |
5/2 | 3/2 | 43 | 18 | |
5/3 | 3/3 | 44 | 19 | |
5/4 | 3/4 | 45 | 20 | |
6/1 | 3/5 | 46 | 21 | |
6/2 | 3/6 | 47 | 22 | |
6/3 | 3/7 | 48 | 23 | |
6/4 | 3/8 | 49 | 24 | |
7/1 | 4/1 | 26 | 1 | Line 25 to 48 or POTS 25 to 48 |
7/2 | 4/2 | 27 | 2 | |
7/3 | 4/3 | 28 | 3 | |
7/4 | 4/4 | 29 | 4 | |
8/1 | 4/5 | 30 | 5 | |
8/2 | 4/6 | 31 | 6 | |
8/3 | 4/7 | 32 | 7 | |
8/4 | 4/8 | 33 | 8 | |
13/1 | 5/1 | 34 | 9 | |
13/2 | 5/2 | 35 | 10 | |
13/3 | 5/3 | 36 | 11 | |
13/4 | 5/4 | 37 | 12 | |
14/1 | 5/5 | 38 | 13 | |
14/2 | 5/6 | 39 | 14 | |
14/3 | 5/7 | 40 | 15 | |
14/4 | 5/8 | 41 | 16 | |
15/1 | 6/1 | 42 | 17 | |
15/2 | 6/2 | 43 | 18 | |
15/3 | 6/3 | 44 | 19 | |
15/4 | 6/4 | 45 | 20 | |
16/1 | 6/5 | 46 | 21 | |
16/2 | 6/6 | 47 | 22 | |
16/3 | 6/7 | 48 | 23 | |
16/4 | 6/8 | 49 | 24 | |
17/1 | 7/1 | 26 | 1 | Line 49 to 72 or POTS 49 to 72 |
17/2 | 7/2 | 27 | 2 | |
17/3 | 7/3 | 28 | 3 | |
17/4 | 7/4 | 29 | 4 | |
18/1 | 7/5 | 30 | 5 | |
18/2 | 7/6 | 31 | 6 | |
18/3 | 7/7 | 32 | 7 | |
18/4 | 7/8 | 33 | 8 | |
19/1 | 8/1 | 34 | 9 | |
19/2 | 8/2 | 35 | 10 | |
19/3 | 8/3 | 36 | 11 | |
19/4 | 8/4 | 37 | 12 | |
20/1 | 8/5 | 38 | 13 | |
20/2 | 8/6 | 39 | 14 | |
20/3 | 8/7 | 40 | 15 | |
20/4 | 8/8 | 41 | 16 | |
21/1 | 9/1 | 42 | 17 | |
21/2 | 9/2 | 43 | 18 | |
21/3 | 9/3 | 44 | 19 | |
21/4 | 9/4 | 45 | 20 | |
22/1 | 9/5 | 46 | 21 | |
22/2 | 9/6 | 47 | 22 | |
22/3 | 9/7 | 48 | 23 | |
22/4 | 9/8 | 49 | 24 | |
23/1 | 10/1 | 26 | 1 | Line 73 to 96 or POTS 73 to 96 |
23/2 | 10/2 | 27 | 2 | |
23/3 | 10/3 | 28 | 3 | |
23/4 | 10/4 | 29 | 4 | |
24/1 | 10/5 | 30 | 5 | |
24/2 | 10/6 | 31 | 6 | |
24/3 | 10/7 | 32 | 7 | |
24/4 | 10/8 | 33 | 8 | |
25/1 | 11/1 | 34 | 9 | |
25/2 | 11/2 | 35 | 10 | |
25/3 | 11/3 | 36 | 11 | |
25/4 | 11/4 | 37 | 12 | |
26/1 | 11/5 | 38 | 13 | |
26/2 | 11/6 | 39 | 14 | |
26/3 | 11/7 | 40 | 15 | |
26/4 | 11/8 | 41 | 16 | |
27/1 | 12/1 | 42 | 17 | |
27/2 | 12/2 | 43 | 18 | |
27/3 | 12/3 | 44 | 19 | |
27/4 | 12/4 | 45 | 20 | |
28/1 | 12/5 | 46 | 21 | |
28/2 | 12/6 | 47 | 22 | |
28/3 | 12/7 | 48 | 23 | |
28/4 | 12/8 | 49 | 24 | |
31/1 | 13/1 | 26 | 1 | Line 97 to 120 or POTS 97 to 120 |
31/2 | 13/2 | 27 | 2 | |
31/3 | 13/3 | 28 | 3 | |
31/4 | 13/4 | 29 | 4 | |
32/1 | 13/5 | 30 | 5 | |
32/2 | 13/6 | 31 | 6 | |
32/3 | 13/7 | 32 | 7 | |
32/4 | 13/8 | 33 | 8 | |
33/1 | 14/1 | 34 | 9 | |
33/2 | 14/2 | 35 | 10 | |
33/3 | 14/3 | 36 | 11 | |
33/4 | 14/4 | 37 | 12 | |
34/1 | 14/5 | 38 | 13 | |
34/2 | 14/6 | 39 | 14 | |
34/3 | 14/7 | 40 | 15 | |
34/4 | 14/8 | 41 | 16 | |
35/1 | 15/1 | 42 | 17 | |
35/2 | 15/2 | 43 | 18 | |
35/3 | 15/3 | 44 | 19 | |
35/4 | 15/4 | 45 | 20 | |
36/1 | 15/5 | 46 | 21 | |
36/2 | 15/6 | 47 | 22 | |
36/3 | 15/7 | 48 | 23 | |
36/4 | 15/8 | 49 | 24 | |
37/1 | 16/1 | 26 | 1 | Line 121 to 128 or POTS 121 to 128 |
37/2 | 16/2 | 27 | 2 | |
37/3 | 16/3 | 28 | 3 | |
37/4 | 16/4 | 29 | 4 | |
38/1 | 16/5 | 30 | 5 | |
38/2 | 16/6 | 31 | 6 | |
38/3 | 16/7 | 32 | 7 | |
38/4 | 16/8 | 33 | 8 | |
Table B-11 maps the Cisco 6130 ports, the Cisco 6120 ports, and the wire pairs when using the two-to-two cables (see Table B-5) for a Direct Connect with a POTS splitter configuration. The corresponding cable kit number is CAB-PSC-80-REPIN.
You can use the two-to-two cables to clearly associate the mapping between the wire pairs and the Cisco 6130 and Cisco 6120 ports. These cables attach to the Cisco 6120 MDF connections (J11 to J14) and the Cisco 6120 POTS connections (J7 to J10) for systems using dual-port xTU-C modules.
| Cisco 6130 Slot/Line | Cisco 6120 Slot/Line | Champ Pins | Cable Connector | |
|---|---|---|---|---|
| Tip | Ring | |||
1/1 | 1/1 | 1 | 26 | P1 |
1/2 | 1/2 | 2 | 27 | |
2/1 | 1/3 | 3 | 28 | |
2/2 | 1/4 | 4 | 29 | |
3/1 | 2/1 | 5 | 30 | |
3/2 | 2/2 | 6 | 31 | |
4/1 | 2/3 | 7 | 32 | |
4/2 | 2/4 | 8 | 33 | |
5/1 | 3/1 | 9 | 34 | |
5/2 | 3/2 | 10 | 35 | |
6/1 | 3/3 | 11 | 36 | |
6/2 | 3/4 | 12 | 37 | |
7/1 | 4/1 | 13 | 38 | |
7/2 | 4/2 | 14 | 39 | |
8/1 | 4/3 | 15 | 40 | |
8/2 | 4/4 | 16 | 41 | |
13/1 | 19/1 | 1 | 26 | P2 |
13/2 | 19/2 | 2 | 27 | |
14/1 | 19/3 | 3 | 28 | |
14/2 | 19/4 | 4 | 29 | |
15/1 | 20/1 | 5 | 30 | |
15/2 | 20/2 | 6 | 31 | |
16/1 | 20/3 | 7 | 32 | |
16/2 | 20/4 | 8 | 33 | |
17/1 | 21/1 | 9 | 34 | |
17/2 | 21/2 | 10 | 35 | |
18/1 | 21/3 | 11 | 36 | |
18/2 | 21/4 | 12 | 37 | |
19/1 | 22/1 | 13 | 38 | |
19/2 | 22/2 | 14 | 39 | |
20/1 | 22/3 | 15 | 40 | |
20/2 | 22/4 | 16 | 41 | |
21/1 | 5/1 | 1 | 26 | P3 |
21/2 | 5/2 | 2 | 27 | |
22/1 | 5/3 | 3 | 28 | |
22/2 | 5/4 | 4 | 29 | |
23/1 | 6/1 | 5 | 30 | |
23/2 | 6/2 | 6 | 31 | |
24/1 | 6/3 | 7 | 32 | |
24/2 | 6/4 | 8 | 33 | |
25/1 | 7/1 | 9 | 34 | |
25/2 | 7/2 | 10 | 35 | |
26/1 | 7/3 | 11 | 36 | |
26/2 | 7/4 | 12 | 37 | |
27/1 | 8/1 | 13 | 38 | |
27/2 | 8/2 | 14 | 39 | |
28/1 | 8/3 | 15 | 40 | |
28/2 | 8/4 | 16 | 41 | |
31/1 | 15/1 | 1 | 26 | P4 |
31/2 | 15/2 | 2 | 27 | |
32/1 | 15/3 | 3 | 28 | |
32/2 | 15/4 | 4 | 29 | |
33/1 | 16/1 | 5 | 30 | |
33/2 | 16/2 | 6 | 31 | |
34/1 | 16/3 | 7 | 32 | |
34/2 | 16/4 | 8 | 33 | |
35/1 | 17/1 | 9 | 34 | |
35/2 | 17/2 | 10 | 35 | |
36/1 | 17/3 | 11 | 36 | |
36/2 | 17/4 | 12 | 37 | |
37/1 | 18/1 | 13 | 38 | |
37/2 | 18/2 | 14 | 39 | |
38/1 | 18/3 | 15 | 40 | |
38/2 | 18/4 | 16 | 41 | |
Table B-12 maps the Cisco 6130 ports and the wire pairs when using the three-to-three cables (see Table B-6) for a Direct Connect without a POTS splitter configuration. The corresponding cable kit number is CAB-MC128-MDF. You can use the three-to-three cables to connect the Cisco 6130 to the MDF for systems using dual-port DMT-2 ATU-C or quad-port xTU-C modules.
| Cisco 6130 Slot/Line | Champ Pins | Cable Connector/ Cable Part Number | |
|---|---|---|---|
| Tip | Ring | ||
1/1 | 1 | 26 | Connector P4/ |
1/2 | 2 | 27 | |
1/3 | 3 | 28 | |
1/4 | 4 | 29 | |
2/1 | 5 | 30 | |
2/2 | 6 | 31 | |
2/3 | 7 | 32 | |
2/4 | 8 | 33 | |
3/1 | 9 | 34 | |
3/2 | 10 | 35 | |
3/3 | 11 | 36 | |
3/4 | 12 | 37 | |
4/1 | 13 | 38 | |
4/2 | 14 | 39 | |
4/3 | 15 | 40 | |
4/4 | 16 | 41 | |
5/1 | 17 | 42 | |
5/2 | 18 | 43 | |
5/3 | 19 | 44 | |
5/4 | 20 | 45 | |
6/1 | 21 | 46 | |
6/2 | 22 | 47 | |
6/3 | 23 | 48 | |
6/4 | 24 | 49 | |
7/1 | 1 | 26 | Connector P5/ |
7/2 | 2 | 27 | |
7/3 | 3 | 28 | |
7/4 | 4 | 29 | |
8/1 | 5 | 30 | |
8/2 | 6 | 31 | |
8/3 | 7 | 32 | |
8/4 | 8 | 33 | |
13/1 | 1 | 26 | Connector P1/ |
13/2 | 2 | 27 | |
13/3 | 3 | 28 | |
13/4 | 4 | 29 | |
14/1 | 5 | 30 | |
14/2 | 6 | 31 | |
14/3 | 7 | 32 | |
14/4 | 8 | 33 | |
15/1 | 9 | 34 | |
15/2 | 10 | 35 | |
15/3 | 11 | 36 | |
15/4 | 12 | 37 | |
16/1 | 13 | 38 | |
16/2 | 14 | 39 | |
16/3 | 15 | 40 | |
16/4 | 16 | 41 | |
17/1 | 17 | 42 | |
17/2 | 18 | 43 | |
17/3 | 19 | 44 | |
17/4 | 20 | 45 | |
18/1 | 21 | 46 | |
18/2 | 22 | 47 | |
18/3 | 23 | 48 | |
18/4 | 24 | 49 | |
19/1 | 1 | 26 | Connector P2/ |
19/2 | 2 | 27 | |
19/3 | 3 | 28 | |
19/4 | 4 | 29 | |
20/1 | 5 | 30 | |
20/2 | 6 | 31 | |
20/3 | 7 | 32 | |
20/4 | 8 | 33 | |
21/1 | 9 | 34 | Connector P5/ |
21/2 | 10 | 35 | |
21/3 | 11 | 36 | |
21/4 | 12 | 37 | |
22/1 | 13 | 38 | |
22/2 | 14 | 39 | |
22/3 | 15 | 40 | |
22/4 | 16 | 41 | |
23/1 | 17 | 42 | |
23/2 | 18 | 43 | |
23/3 | 19 | 44 | |
23/4 | 20 | 45 | |
24/1 | 21 | 46 | |
24/2 | 22 | 47 | |
24/3 | 23 | 48 | |
24/4 | 24 | 49 | |
25/1 | 1 | 26 | Connector P6/ |
25/2 | 2 | 27 | |
25/3 | 3 | 28 | |
25/4 | 4 | 29 | |
26/1 | 5 | 30 | |
26/2 | 6 | 31 | |
26/3 | 7 | 32 | |
26/4 | 8 | 33 | |
27/1 | 9 | 34 | |
27/2 | 10 | 35 | |
27/3 | 11 | 36 | |
27/4 | 12 | 37 | |
28/1 | 13 | 38 | |
28/2 | 14 | 39 | |
28/3 | 15 | 40 | |
28/4 | 16 | 41 | |
31/1 | 9 | 34 | Connector P2/ |
31/2 | 10 | 35 | |
31/3 | 11 | 36 | |
31/4 | 12 | 37 | |
32/1 | 13 | 38 | |
32/2 | 14 | 39 | |
32/3 | 15 | 40 | |
32/4 | 16 | 41 | |
33/1 | 17 | 42 | |
33/2 | 18 | 43 | |
33/3 | 19 | 44 | |
33/4 | 20 | 45 | |
34/1 | 21 | 46 | |
34/2 | 22 | 47 | |
34/3 | 23 | 48 | |
34/4 | 24 | 49 | |
35/1 | 1 | 26 | Connector P3/ |
35/2 | 2 | 27 | |
35/3 | 3 | 28 | |
35/4 | 4 | 29 | |
36/1 | 5 | 30 | |
36/2 | 6 | 31 | |
36/3 | 7 | 32 | |
36/4 | 8 | 33 | |
37/1 | 9 | 34 | |
37/2 | 10 | 35 | |
37/3 | 11 | 36 | |
37/4 | 12 | 37 | |
38/1 | 13 | 38 | |
38/2 | 14 | 39 | |
38/3 | 15 | 40 | |
38/4 | 16 | 41 | |
Table B-13 provides the Champ pins and Cisco 6130 port mapping information needed to build your own chassis cables.
| Connector | Champ Pins | Cisco 6130 Slot/Line | |
|---|---|---|---|
| Tip | Ring | ||
J39 xDSL Slots 3 through 8 (pins 25 and 50 are not used) | 1 | 2 | 6/1 |
3 | 4 | 6/2 | |
5 | 6 | 6/3 | |
7 | 8 | 6/4 | |
9 | 10 | 7/1 | |
11 | 12 | 7/2 | |
13 | 14 | 7/3 | |
15 | 16 | 7/4 | |
17 | 18 | 8/1 | |
19 | 20 | 8/2 | |
21 | 22 | 8/3 | |
23 | 24 | 8/4 | |
26 | 27 | 5/1 | |
28 | 29 | 5/2 | |
30 | 31 | 5/3 | |
32 | 33 | 5/4 | |
34 | 35 | 4/1 | |
36 | 37 | 4/2 | |
38 | 39 | 4/3 | |
40 | 41 | 4/4 | |
42 | 43 | 3/1 | |
44 | 45 | 3/2 | |
46 | 47 | 3/3 | |
48 | 49 | 3/4 | |
J40 xDSL Slots 1, 2, 21, and 22 (pins 9 through 25 are not used) | 1 | 2 | 22/1 |
3 | 4 | 22/2 | |
5 | 6 | 22/3 | |
7 | 8 | 22/4 | |
26 | 27 | 21/1 | |
28 | 29 | 21/2 | |
30 | 31 | 21/3 | |
32 | 33 | 21/4 | |
34 | 35 | 2/1 | |
36 | 37 | 2/2 | |
38 | 39 | 2/3 | |
40 | 41 | 2/4 | |
42 | 43 | 1/1 | |
44 | 45 | 1/2 | |
46 | 47 | 1/3 | |
48 | 49 | 1/4 | |
J41 xDSL Slots 23 through 23 (pins 25 and 50 are not used) | 1 | 2 | 26/1 |
3 | 4 | 26/2 | |
5 | 6 | 26/3 | |
7 | 8 | 26/4 | |
9 | 10 | 27/1 | |
11 | 12 | 27/2 | |
13 | 14 | 27/3 | |
15 | 16 | 27/4 | |
17 | 18 | 28/1 | |
19 | 20 | 28/2 | |
21 | 22 | 28/3 | |
23 | 24 | 28/4 | |
26 | 27 | 25/1 | |
28 | 29 | 25/2 | |
30 | 31 | 25/3 | |
32 | 33 | 25/4 | |
34 | 35 | 24/1 | |
36 | 37 | 24/2 | |
38 | 39 | 24/3 | |
40 | 41 | 24/4 | |
42 | 43 | 23/1 | |
44 | 45 | 23/2 | |
46 | 47 | 23/3 | |
48 | 49 | 23/4 | |
J42 xDSL Slots 13 through 18 (pins 25 and 50 are not used) | 1 | 2 | 17/1 |
3 | 4 | 17/2 | |
5 | 6 | 17/3 | |
7 | 8 | 17/4 | |
9 | 10 | 18/1 | |
11 | 12 | 18/2 | |
13 | 14 | 18/3 | |
15 | 16 | 18/4 | |
17 | 18 | 13/1 | |
19 | 20 | 13/2 | |
21 | 22 | 13/3 | |
23 | 24 | 13/4 | |
26 | 27 | 16/1 | |
28 | 29 | 16/2 | |
30 | 31 | 16/3 | |
32 | 33 | 16/4 | |
34 | 35 | 15/1 | |
36 | 37 | 15/2 | |
38 | 39 | 15/3 | |
40 | 41 | 15/4 | |
42 | 43 | 14/1 | |
44 | 45 | 14/2 | |
46 | 47 | 14/3 | |
48 | 49 | 14/4 | |
J43 xDSL Slots 19, 20, 37, and 38 (pins 9 through 25 and 50 are not used) | 1 | 2 | 20/1 |
3 | 4 | 20/2 | |
5 | 6 | 20/3 | |
7 | 8 | 20/4 | |
26 | 27 | 19/1 | |
28 | 29 | 19/2 | |
30 | 31 | 19/3 | |
32 | 33 | 19/4 | |
34 | 35 | 38/1 | |
36 | 37 | 38/2 | |
38 | 39 | 38/3 | |
40 | 41 | 38/4 | |
42 | 43 | 37/1 | |
44 | 45 | 37/2 | |
46 | 47 | 37/3 | |
48 | 49 | 37/4 | |
J44 xDSL Slots 31 through 36 (pins 25 and 50 are not used) | 1 | 2 | 35/1 |
3 | 4 | 35/2 | |
5 | 6 | 35/3 | |
7 | 8 | 35/4 | |
9 | 10 | 36/1 | |
11 | 12 | 36/2 | |
13 | 14 | 36/3 | |
15 | 16 | 36/4 | |
17 | 18 | 31/1 | |
19 | 20 | 31/2 | |
21 | 22 | 31/3 | |
23 | 24 | 31/4 | |
26 | 27 | 34/1 | |
28 | 29 | 34/2 | |
30 | 31 | 34/3 | |
32 | 33 | 34/4 | |
34 | 35 | 33/1 | |
36 | 37 | 33/2 | |
38 | 39 | 33/3 | |
40 | 41 | 33/4 | |
42 | 43 | 32/1 | |
44 | 45 | 32/2 | |
46 | 47 | 32/3 | |
48 | 49 | 32/4 | |
In designing the cables for the Cisco 6130 with NI-2 system connections, Cisco used a standard telco color chart. Table B-14 lists the colors used for the Cisco 6130 with NI-2 system cables.
| Wire Color | P1 | Wire Color | P2 | Wire Color | P1 | Wire Color | P2 | |
|---|---|---|---|---|---|---|---|---|
Wht/blu | 1 | Wht/blu | 1 |
| Grn/blk | 38 | Grn/blk | 38 |
Blu/wht | 26 | Blu/wht | 26 |
| Blk/brn | 14 | Blk/brn | 14 |
Wht/org | 2 | Wht/org | 2 |
| Brn/blk | 39 | Brn/blk | 39 |
Org/wht | 27 | Org/wht | 27 |
| Blk/gry | 15 | Blk/gry | 15 |
Wht/grn | 3 | Wht/grn | 3 |
| Gry/blk | 40 | Gry/blk | 40 |
Grn/wht | 28 | Grn/wht | 28 |
| Yel/blu | 16 | Yel/blu | 16 |
Wht/brn | 4 | Wht/brn | 4 |
| Blu/yel | 41 | Blu/yel | 41 |
Brn/wht | 29 | Brn/wht | 29 |
| Yel/org | 17 | Yel/org | 17 |
Wht/gry | 5 | Wht/gry | 5 |
| Org/yel | 42 | Org/yel | 42 |
Gry/wht | 30 | Gry/wht | 30 |
| Yel/grn | 18 | Yel/grn | 18 |
Red/blu | 6 | Red/blu | 6 |
| Grn/yel | 43 | Grn/yel | 43 |
Blu/red | 31 | Blu/red | 31 |
| Yel/brn | 19 | Yel/brn | 19 |
Red/org | 7 | Red/org | 7 |
| Brn/yel | 44 | Brn/yel | 44 |
Org/red | 32 | Org/red | 32 |
| Yel/gry | 20 | Yel/gry | 20 |
Red/grn | 8 | Red/grn | 8 |
| Gry/yel | 45 | Gry/yel | 45 |
Grn/red | 33 | Grn/red | 33 |
| Vio/blu | 21 | Vio/blu | 21 |
Red/brn | 9 | Red/brn | 9 |
| Blu/vio | 46 | Blu/vio | 46 |
Brn/red | 34 | Brn/red | 34 |
| Vio/org | 22 | Vio/org | 22 |
Red/gry | 10 | Red/gry | 10 |
| Org/vio | 47 | Org/vio | 47 |
Gry/red | 35 | Gry/red | 35 |
| Vio/grn | 23 | Vio/grn | 23 |
Blk/blu | 11 | Blk/blu | 11 |
| Grn/vio | 48 | Grn/vio | 48 |
Blu/blk | 36 | Blu/blk | 36 |
| Vio/brn | 24 | Vio/brn | 24 |
Blk/org | 12 | Blk/org | 12 |
| Brn/vio | 49 | Brn/vio | 49 |
Org/blk | 37 | Org/blk | 37 |
| Vio/gry | 25 | Vio/gry | 25 |
Blk/grn | 13 | Blk/grn | 13 |
| Gry/vio | 50 | Gry/vio | 50 |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Aug 11 15:45:35 PDT 2000