This appendix provides port mapping tables which show the wire pair and chassis port assignments for the following configurations and cables:
Cisco used a standard telco color chart when designing the cables for the Cisco 6100 Series connections. This appendix includes a standard telco color chart.
Table D-1 maps the Cisco 6100/6130 ports, the Cisco 6120 ports, and the wire pairs when using the one-to-one cables (see Table C-2) for a Direct Connect with a POTS splitter configuration. The corresponding cable kit number is CAB-61-014.
| Cisco 6100/6130 Slot/Line | Cisco 6120 Slot/Line | Champ Pins | Cisco 6120 MDF/POTS Connection | |
|---|---|---|---|---|
| Tip | Ring | |||
1/1 | 1/1 | 9 | 34 | J11/J7 |
1/2 | 1/2 | 10 | 35 | |
2/1 | 1/3 | 11 | 36 | |
2/2 | 1/4 | 12 | 37 | |
3/1 | 2/1 | 5 | 30 | |
3/2 | 2/2 | 6 | 31 | |
4/1 | 2/3 | 7 | 32 | |
4/2 | 2/4 | 8 | 33 | |
5/1 | 3/1 | 1 | 26 | |
5/2 | 3/2 | 2 | 27 | |
6/1 | 3/3 | 3 | 28 | |
6/2 | 3/4 | 4 | 29 | |
7/1 | 4/1 | 18 | 43 | |
7/2 | 4/2 | 19 | 44 | |
8/1 | 4/3 | 20 | 45 | |
8/2 | 4/4 | 21 | 46 | |
13/1 | 19/1 | 18 | 43 | J14/J8 |
13/2 | 19/2 | 19 | 44 | |
14/1 | 19/3 | 20 | 45 | |
14/2 | 19/4 | 21 | 46 | |
15/1 | 20/1 | 1 | 26 | |
15/2 | 20/2 | 2 | 27 | |
16/1 | 20/3 | 3 | 28 | |
16/2 | 20/4 | 4 | 29 | |
17/1 | 21/1 | 5 | 30 | |
17/2 | 21/2 | 6 | 31 | |
18/1 | 21/3 | 7 | 32 | |
18/2 | 21/4 | 8 | 33 | |
19/1 | 22/1 | 9 | 34 | |
19/2 | 22/2 | 10 | 35 | |
20/1 | 22/3 | 11 | 36 | |
20/2 | 22/4 | 12 | 37 | |
21/1 | 5/1 | 22 | 47 | J11/J7 |
21/2 | 5/2 | 23 | 48 | |
22/1 | 5/3 | 24 | 49 | |
22/2 | 5/4 | 25 | 50 | |
23/1 | 6/1 | 6 | 31 | J12/J9 |
23/2 | 6/2 | 7 | 32 | |
24/1 | 6/3 | 8 | 33 | |
24/2 | 6/4 | 9 | 34 | |
25/1 | 7/1 | 2 | 27 | |
25/2 | 7/2 | 3 | 28 | |
26/1 | 7/3 | 4 | 29 | |
26/2 | 7/4 | 5 | 30 | |
27/1 | 8/1 | 1 | 26 | |
27/2 | 8/2 | 10 | 35 | |
28/1 | 8/3 | 11 | 36 | |
28/2 | 8/4 | 12 | 37 | |
31/1 | 15/1 | 1 | 26 | J13/J10 |
31/2 | 15/2 | 10 | 35 | |
32/1 | 15/3 | 11 | 36 | |
32/2 | 15/4 | 12 | 37 | |
33/1 | 16/1 | 2 | 27 | |
33/2 | 16/2 | 3 | 28 | |
34/1 | 16/3 | 4 | 29 | |
34/2 | 16/4 | 5 | 30 | |
35/1 | 17/1 | 6 | 31 | |
35/2 | 17/2 | 7 | 32 | |
36/1 | 17/3 | 8 | 33 | |
36/2 | 17/4 | 9 | 34 | |
37/1 | 18/1 | 22 | 47 | J14/J8 |
37/2 | 18/2 | 23 | 48 | |
38/1 | 18/3 | 24 | 49 | |
38/2 | 18/4 | 25 | 50 | |
Table D-2 maps the Cisco 6100/6130 ports, the Cisco 6120 ports for two Cisco 6120 chassis, and the wire pairs when using the one-to-two cables (see Table C-3) for a Direct Connect with a POTS splitter configuration. The corresponding cable kit number is CAB-MC128-PSC80. You can use the one-to-two cables to connect one Cisco 6100/6130 to two Cisco 6120 chassis for systems using quad-port ATU-C modules.
| Cisco 6100/6130 Slot/Line | Cisco 6120 Slot/Line | Champ Pins | Cisco 6120 MDF/ POTS Connection | ||
|---|---|---|---|---|---|
| Cisco 6120 Chassis 1 | Cisco 6120 Chassis 2 | Tip | Ring | ||
1/1 | 1/1 | --- | 9 | 34 | J11/J7 |
1/2 | 1/2 | --- | 10 | 35 | |
1/3 | --- | 1/1 | 9 | 34 | |
1/4 | --- | 1/2 | 10 | 35 | |
2/1 | 1/3 | --- | 11 | 36 | |
2/2 | 1/4 | --- | 12 | 37 | |
2/3 | --- | 1/3 | 11 | 36 | |
2/4 | --- | 1/4 | 12 | 37 | |
3/1 | 2/1 | --- | 5 | 30 | |
3/2 | 2/2 | --- | 6 | 31 | |
3/3 | --- | 2/1 | 5 | 30 | |
3/4 | --- | 2/2 | 6 | 31 | |
4/1 | 2/3 | --- | 7 | 32 | |
4/2 | 2/4 | --- | 8 | 33 | |
4/3 | --- | 2/3 | 7 | 32 | |
4/4 | --- | 2/4 | 8 | 33 | |
5/1 | 3/1 | --- | 1 | 26 | |
5/2 | 3/2 | --- | 2 | 27 | |
5/3 | --- | 3/1 | 1 | 26 | |
5/4 | --- | 3/2 | 2 | 27 | |
6/1 | 3/3 | --- | 3 | 28 | |
6/2 | 3/4 | --- | 4 | 29 | |
6/3 | --- | 3/3 | 3 | 28 | |
6/4 | --- | 3/4 | 4 | 29 | |
7/1 | 4/1 | --- | 18 | 43 | |
7/2 | 4/2 | --- | 19 | 44 | |
7/3 | --- | 4/1 | 18 | 43 | |
7/4 | --- | 4/2 | 19 | 44 | |
8/1 | 4/3 | --- | 20 | 45 | |
8/2 | 4/4 | --- | 21 | 46 | |
8/3 | --- | 4/3 | 20 | 45 | |
8/4 | --- | 4/4 | 21 | 46 | |
13/1 | 19/1 | --- | 18 | 43 | J14/J8 |
13/2 | 19/2 | --- | 19 | 44 | |
13/3 | --- | 19/1 | 18 | 43 | |
13/4 | --- | 19/2 | 19 | 44 | |
14/1 | 19/3 | --- | 20 | 45 | |
14/2 | 19/4 | --- | 21 | 46 | |
14/3 | --- | 19/3 | 20 | 45 | |
14/4 | --- | 19/4 | 21 | 46 | |
15/1 | 20/1 | --- | 1 | 26 | |
15/2 | 20/2 | --- | 2 | 27 | |
15/3 | --- | 20/1 | 1 | 26 | |
15/4 | --- | 20/2 | 2 | 27 | |
16/1 | 20/3 | --- | 3 | 28 | |
16/2 | 20/4 | --- | 4 | 29 | |
16/3 | --- | 20/3 | 3 | 28 | |
16/4 | --- | 20/4 | 4 | 29 | |
17/1 | 21/1 | --- | 5 | 30 | |
17/2 | 21/2 | --- | 6 | 31 | |
17/3 | --- | 21/1 | 5 | 30 | |
17/4 | --- | 21/2 | 6 | 31 | |
18/1 | 21/3 | --- | 7 | 32 | |
18/2 | 21/4 | --- | 8 | 33 | |
18/3 | --- | 21/3 | 7 | 32 | |
18/4 | --- | 21/4 | 8 | 33 | |
19/1 | 22/1 | --- | 9 | 34 | |
19/2 | 22/2 | --- | 10 | 35 | |
19/3 | --- | 22/1 | 9 | 34 | |
19/4 | --- | 22/2 | 10 | 35 | |
20/1 | 22/3 | --- | 11 | 36 | |
20/2 | 22/4 | --- | 12 | 37 | |
20/3 | --- | 22/3 | 11 | 36 | |
20/4 | --- | 22/4 | 12 | 37 | |
21/1 | 5/1 | --- | 22 | 47 | J11/J7 |
21/2 | 5/2 | --- | 23 | 48 | |
21/3 | --- | 5/1 | 22 | 47 | |
21/4 | --- | 5/2 | 23 | 48 | |
22/1 | 5/3 | --- | 24 | 49 | |
22/2 | 5/4 | --- | 25 | 50 | |
22/3 | --- | 5/3 | 24 | 49 | |
22/4 | --- | 5/4 | 25 | 50 | |
23/1 | 6/1 | --- | 6 | 31 | J12/J9 |
23/2 | 6/2 | --- | 7 | 32 | |
23/3 | --- | 6/1 | 6 | 31 | |
23/4 | --- | 6/2 | 7 | 32 | |
24/1 | 6/3 | --- | 8 | 33 | |
24/2 | 6/4 | --- | 9 | 34 | |
24/3 | --- | 6/3 | 8 | 33 | |
24/4 | --- | 6/4 | 9 | 34 | |
25/1 | 7/1 | --- | 2 | 27 | |
25/2 | 7/2 | --- | 3 | 28 | |
25/3 | --- | 7/1 | 2 | 27 | |
25/4 | --- | 7/2 | 3 | 28 | |
26/1 | 7/3 | --- | 4 | 29 | |
26/2 | 7/4 | --- | 5 | 30 | |
26/3 | --- | 7/3 | 4 | 29 | |
26/4 | --- | 7/4 | 5 | 30 | |
27/1 | 8/1 | --- | 1 | 26 | |
27/2 | 8/2 | --- | 10 | 35 | |
27/3 | --- | 8/1 | 1 | 26 | |
27/4 | --- | 8/2 | 10 | 35 | |
28/1 | 8/3 | --- | 11 | 36 | |
28/2 | 8/4 | --- | 12 | 37 | |
28/3 | --- | 8/3 | 11 | 36 | |
28/4 | --- | 8/4 | 12 | 37 | |
31/1 | 15/1 | --- | 1 | 26 | J13/J10 |
31/2 | 15/2 | --- | 10 | 35 | |
31/3 | --- | 15/1 | 1 | 26 | |
31/4 | --- | 15/2 | 10 | 35 | |
32/1 | 15/3 | --- | 11 | 36 | |
32/2 | 15/4 | --- | 12 | 37 | |
32/3 | --- | 15/3 | 11 | 36 | |
32/4 | --- | 15/4 | 12 | 37 | |
33/1 | 16/1 | --- | 2 | 27 | |
33/2 | 16/2 | --- | 3 | 28 | |
33/3 | --- | 16/1 | 2 | 27 | |
33/4 | --- | 16/2 | 3 | 28 | |
34/1 | 16/3 | --- | 4 | 29 | |
34/2 | 16/4 | --- | 5 | 30 | |
34/3 | --- | 16/3 | 4 | 29 | |
34/4 | --- | 16/4 | 5 | 30 | |
35/1 | 17/1 | --- | 6 | 31 | |
35/2 | 17/2 | --- | 7 | 32 | |
35/3 | --- | 17/1 | 6 | 31 | |
35/4 | --- | 17/2 | 7 | 32 | |
36/1 | 17/3 | --- | 8 | 33 | |
36/2 | 17/4 | --- | 9 | 34 | |
36/3 | --- | 17/3 | 8 | 33 | |
36/4 | --- | 17/4 | 9 | 34 | |
37/1 | 18/1 | --- | 22 | 47 | J14/J8 |
37/2 | 18/2 | --- | 23 | 48 | |
37/3 | --- | 18/1 | 22 | 47 | |
37/4 | --- | 18/2 | 23 | 48 | |
38/1 | 18/3 | --- | 24 | 49 | |
38/2 | 18/4 | --- | 25 | 50 | |
38/3 | --- | 18/3 | 24 | 49 | |
38/4 | --- | 18/4 | 25 | 50 | |
Table D-3 maps the Cisco 6100/6130 ports, the POTS splitter ports, and the wire pairs when using the one-to-one cables (see Table C-4) when a Siecor POTS splitter is installed in your configuration. The corresponding cable kit number is CAB-6121-1.
| Cisco 6100/6130 Slot/Line | POTS Splitter Slot/Line | Champ Pins | POTS Splitter Connection | |
|---|---|---|---|---|
| Tip | Ring | |||
1/1 | 1/1 | 26 | 1 | Line 1 to 24 or POTS 1 to 24 |
1/2 | 1/2 | 27 | 2 | |
1/3 | 1/3 | 28 | 3 | |
1/4 | 1/4 | 29 | 4 | |
2/1 | 1/5 | 30 | 5 | |
2/2 | 1/6 | 31 | 6 | |
2/3 | 1/7 | 32 | 7 | |
2/4 | 1/8 | 33 | 8 | |
3/1 | 2/1 | 34 | 9 | |
3/2 | 2/2 | 35 | 10 | |
3/3 | 2/3 | 36 | 11 | |
3/4 | 2/4 | 37 | 12 | |
4/1 | 2/5 | 38 | 13 | |
4/2 | 2/6 | 39 | 14 | |
4/3 | 2/7 | 40 | 15 | |
4/4 | 2/8 | 41 | 16 | |
5/1 | 3/1 | 42 | 17 | |
5/2 | 3/2 | 43 | 18 | |
5/3 | 3/3 | 44 | 19 | |
5/4 | 3/4 | 45 | 20 | |
6/1 | 3/5 | 46 | 21 | |
6/2 | 3/6 | 47 | 22 | |
6/3 | 3/7 | 48 | 23 | |
6/4 | 3/8 | 49 | 24 | |
7/1 | 4/1 | 26 | 1 | Line 25 to 48 or POTS 25 to 48 |
7/2 | 4/2 | 27 | 2 | |
7/3 | 4/3 | 28 | 3 | |
7/4 | 4/4 | 29 | 4 | |
8/1 | 4/5 | 30 | 5 | |
8/2 | 4/6 | 31 | 6 | |
8/3 | 4/7 | 32 | 7 | |
8/4 | 4/8 | 33 | 8 | |
13/1 | 5/1 | 34 | 9 | |
13/2 | 5/2 | 35 | 10 | |
13/3 | 5/3 | 36 | 11 | |
13/4 | 5/4 | 37 | 12 | |
14/1 | 5/5 | 38 | 13 | |
14/2 | 5/6 | 39 | 14 | |
14/3 | 5/7 | 40 | 15 | |
14/4 | 5/8 | 41 | 16 | |
15/1 | 6/1 | 42 | 17 | |
15/2 | 6/2 | 43 | 18 | |
15/3 | 6/3 | 44 | 19 | |
15/4 | 6/4 | 45 | 20 | |
16/1 | 6/5 | 46 | 21 | |
16/2 | 6/6 | 47 | 22 | |
16/3 | 6/7 | 48 | 23 | |
16/4 | 6/8 | 49 | 24 | |
17/1 | 7/1 | 26 | 1 | Line 49 to 72 or POTS 49 to 72 |
17/2 | 7/2 | 27 | 2 | |
17/3 | 7/3 | 28 | 3 | |
17/4 | 7/4 | 29 | 4 | |
18/1 | 7/5 | 30 | 5 | |
18/2 | 7/6 | 31 | 6 | |
18/3 | 7/7 | 32 | 7 | |
18/4 | 7/8 | 33 | 8 | |
19/1 | 8/1 | 34 | 9 | |
19/2 | 8/2 | 35 | 10 | |
19/3 | 8/3 | 36 | 11 | |
19/4 | 8/4 | 37 | 12 | |
20/1 | 8/5 | 38 | 13 | |
20/2 | 8/6 | 39 | 14 | |
20/3 | 8/7 | 40 | 15 | |
20/4 | 8/8 | 41 | 16 | |
21/1 | 9/1 | 42 | 17 | |
21/2 | 9/2 | 43 | 18 | |
21/3 | 9/3 | 44 | 19 | |
21/4 | 9/4 | 45 | 20 | |
22/1 | 9/5 | 46 | 21 | |
22/2 | 9/6 | 47 | 22 | |
22/3 | 9/7 | 48 | 23 | |
22/4 | 9/8 | 49 | 24 | |
23/1 | 10/1 | 26 | 1 | Line 73 to 96 or POTS 73 to 96 |
23/2 | 10/2 | 27 | 2 | |
23/3 | 10/3 | 28 | 3 | |
23/4 | 10/4 | 29 | 4 | |
24/1 | 10/5 | 30 | 5 | |
24/2 | 10/6 | 31 | 6 | |
24/3 | 10/7 | 32 | 7 | |
24/4 | 10/8 | 33 | 8 | |
25/1 | 11/1 | 34 | 9 | |
25/2 | 11/2 | 35 | 10 | |
25/3 | 11/3 | 36 | 11 | |
25/4 | 11/4 | 37 | 12 | |
26/1 | 11/5 | 38 | 13 | |
26/2 | 11/6 | 39 | 14 | |
26/3 | 11/7 | 40 | 15 | |
26/4 | 11/8 | 41 | 16 | |
27/1 | 12/1 | 42 | 17 | |
27/2 | 12/2 | 43 | 18 | |
27/3 | 12/3 | 44 | 19 | |
27/4 | 12/4 | 45 | 20 | |
28/1 | 12/5 | 46 | 21 | |
28/2 | 12/6 | 47 | 22 | |
28/3 | 12/7 | 48 | 23 | |
28/4 | 12/8 | 49 | 24 | |
31/1 | 13/1 | 26 | 1 | Line 97 to 120 or POTS 97 to 120 |
31/2 | 13/2 | 27 | 2 | |
31/3 | 13/3 | 28 | 3 | |
31/4 | 13/4 | 29 | 4 | |
32/1 | 13/5 | 30 | 5 | |
32/2 | 13/6 | 31 | 6 | |
32/3 | 13/7 | 32 | 7 | |
32/4 | 13/8 | 33 | 8 | |
33/1 | 14/1 | 34 | 9 | |
33/2 | 14/2 | 35 | 10 | |
33/3 | 14/3 | 36 | 11 | |
33/4 | 14/4 | 37 | 12 | |
34/1 | 14/5 | 38 | 13 | |
34/2 | 14/6 | 39 | 14 | |
34/3 | 14/7 | 40 | 15 | |
34/4 | 14/8 | 41 | 16 | |
35/1 | 15/1 | 42 | 17 | |
35/2 | 15/2 | 43 | 18 | |
35/3 | 15/3 | 44 | 19 | |
35/4 | 15/4 | 45 | 20 | |
36/1 | 15/5 | 46 | 21 | |
36/2 | 15/6 | 47 | 22 | |
36/3 | 15/7 | 48 | 23 | |
36/4 | 15/8 | 49 | 24 | |
37/1 | 16/1 | 26 | 1 | Line 121 to 128 or POTS 121 to 128 |
37/2 | 16/2 | 27 | 2 | |
37/3 | 16/3 | 28 | 3 | |
37/4 | 16/4 | 29 | 4 | |
38/1 | 16/5 | 30 | 5 | |
38/2 | 16/6 | 31 | 6 | |
38/3 | 16/7 | 32 | 7 | |
38/4 | 16/8 | 33 | 8 | |
Table D-4 maps the Cisco 6100/6130 ports, the Cisco 6120 ports, and the wire pairs when using the two-to-two cables (see Table C-6) for a Direct Connect with a POTS splitter configuration. The corresponding cable kit number is CAB-PSC-80-REPIN.
You can use the two-to-two cables to clearly associate the mapping between the wire pairs and the Cisco 6100/6130 and Cisco 6120 ports. These cables attach to the Cisco 6120 MDF connections (J11 to J14) and the Cisco 6120 POTS connections (J7 to J10) for systems using dual-port xTU-C modules.
| Cisco 6100/6130 Slot/Line | Cisco 6120 Slot/Line | Champ Pins | Cable Connector | |
|---|---|---|---|---|
| Tip | Ring | |||
1/1 | 1/1 | 1 | 26 | P1 |
1/2 | 1/2 | 2 | 27 | |
2/1 | 1/3 | 3 | 28 | |
2/2 | 1/4 | 4 | 29 | |
3/1 | 2/1 | 5 | 30 | |
3/2 | 2/2 | 6 | 31 | |
4/1 | 2/3 | 7 | 32 | |
4/2 | 2/4 | 8 | 33 | |
5/1 | 3/1 | 9 | 34 | |
5/2 | 3/2 | 10 | 35 | |
6/1 | 3/3 | 11 | 36 | |
6/2 | 3/4 | 12 | 37 | |
7/1 | 4/1 | 13 | 38 | |
7/2 | 4/2 | 14 | 39 | |
8/1 | 4/3 | 15 | 40 | |
8/2 | 4/4 | 16 | 41 | |
13/1 | 19/1 | 1 | 26 | P2 |
13/2 | 19/2 | 2 | 27 | |
14/1 | 19/3 | 3 | 28 | |
14/2 | 19/4 | 4 | 29 | |
15/1 | 20/1 | 5 | 30 | |
15/2 | 20/2 | 6 | 31 | |
16/1 | 20/3 | 7 | 32 | |
16/2 | 20/4 | 8 | 33 | |
17/1 | 21/1 | 9 | 34 | |
17/2 | 21/2 | 10 | 35 | |
18/1 | 21/3 | 11 | 36 | |
18/2 | 21/4 | 12 | 37 | |
19/1 | 22/1 | 13 | 38 | |
19/2 | 22/2 | 14 | 39 | |
20/1 | 22/3 | 15 | 40 | |
20/2 | 22/4 | 16 | 41 | |
21/1 | 5/1 | 1 | 26 | P3 |
21/2 | 5/2 | 2 | 27 | |
22/1 | 5/3 | 3 | 28 | |
22/2 | 5/4 | 4 | 29 | |
23/1 | 6/1 | 5 | 30 | |
23/2 | 6/2 | 6 | 31 | |
24/1 | 6/3 | 7 | 32 | |
24/2 | 6/4 | 8 | 33 | |
25/1 | 7/1 | 9 | 34 | |
25/2 | 7/2 | 10 | 35 | |
26/1 | 7/3 | 11 | 36 | |
26/2 | 7/4 | 12 | 37 | |
27/1 | 8/1 | 13 | 38 | |
27/2 | 8/2 | 14 | 39 | |
28/1 | 8/3 | 15 | 40 | |
28/2 | 8/4 | 16 | 41 | |
31/1 | 15/1 | 1 | 26 | P4 |
31/2 | 15/2 | 2 | 27 | |
32/1 | 15/3 | 3 | 28 | |
32/2 | 15/4 | 4 | 29 | |
33/1 | 16/1 | 5 | 30 | |
33/2 | 16/2 | 6 | 31 | |
34/1 | 16/3 | 7 | 32 | |
34/2 | 16/4 | 8 | 33 | |
35/1 | 17/1 | 9 | 34 | |
35/2 | 17/2 | 10 | 35 | |
36/1 | 17/3 | 11 | 36 | |
36/2 | 17/4 | 12 | 37 | |
37/1 | 18/1 | 13 | 38 | |
37/2 | 18/2 | 14 | 39 | |
38/1 | 18/3 | 15 | 40 | |
38/2 | 18/4 | 16 | 41 | |
Table D-5 maps the Cisco 6130 ports and the wire pairs when using the three-to-two cables (see Table C-7) for a Direct Connect without a POTS splitter configuration. The corresponding cable kit number is CAB-MC-3:2-REPIN. You can use the three-to-two cables to connect the Cisco 6130 to the MDF for systems using dual-port DMT-2 ATU-C modules.
![]() |
Note This cable is not recommended if you plan on expanding your system to quad-port xTU-C modules. |
| Cisco 6130 Slot/Line | Champ Pins | Cable Connector/ Cable Part Number | |
|---|---|---|---|
| Tip | Ring | ||
1/1 | 1 | 26 | Connector P2/ |
1/2 | 2 | 27 | |
2/1 | 3 | 28 | |
2/2 | 4 | 29 | |
3/1 | 5 | 30 | |
3/2 | 6 | 31 | |
4/1 | 7 | 32 | |
4/2 | 8 | 33 | |
5/1 | 9 | 34 | |
5/2 | 10 | 35 | |
6/1 | 11 | 36 | |
6/2 | 12 | 37 | |
7/1 | 13 | 38 | |
7/2 | 14 | 39 | |
8/1 | 15 | 40 | |
8/2 | 16 | 41 | |
13/1 | 1 | 26 | Connector P2/ |
13/2 | 2 | 27 | |
14/1 | 3 | 28 | |
14/2 | 4 | 29 | |
15/1 | 5 | 30 | |
15/2 | 6 | 31 | |
16/1 | 7 | 32 | |
16/2 | 8 | 33 | |
17/1 | 9 | 34 | |
17/2 | 10 | 35 | |
18/1 | 11 | 36 | |
18/2 | 12 | 37 | |
19/1 | 13 | 38 | |
19/2 | 14 | 39 | |
20/1 | 15 | 40 | |
20/2 | 16 | 41 | |
21/1 | 1 | 26 | Connector P1/ |
21/2 | 2 | 27 | |
22/1 | 3 | 28 | |
22/2 | 4 | 29 | |
23/1 | 5 | 30 | |
23/2 | 6 | 31 | |
24/1 | 7 | 32 | |
24/2 | 8 | 33 | |
25/1 | 9 | 34 | |
25/2 | 10 | 35 | |
26/1 | 11 | 36 | |
26/2 | 12 | 37 | |
27/1 | 13 | 38 | |
27/2 | 14 | 39 | |
28/1 | 15 | 40 | |
28/2 | 16 | 41 | |
31/1 | 1 | 26 | Connector P1/ |
31/2 | 2 | 27 | |
32/1 | 3 | 28 | |
32/2 | 4 | 29 | |
33/1 | 5 | 30 | |
33/2 | 6 | 31 | |
34/1 | 7 | 32 | |
34/2 | 8 | 33 | |
35/1 | 9 | 34 | |
35/2 | 10 | 35 | |
36/1 | 11 | 36 | |
36/2 | 12 | 37 | |
37/1 | 13 | 38 | |
37/2 | 14 | 39 | |
38/1 | 15 | 40 | |
38/2 | 16 | 41 | |
Table D-6 maps the Cisco 6130 ports and the wire pairs when using the three-to-three cables (see Table C-8) for a Direct Connect without a POTS splitter configuration. The corresponding cable kit number is CAB-MC128-MDF. You can use the three-to-three cables to connect the Cisco 6130 to the MDF for systems using dual-port DMT-2 ATU-C or quad-port xTU-C modules.
| Cisco 6130 Slot/Line | Champ Pins | Cable Connector/ Cable Part Number | |
|---|---|---|---|
| Tip | Ring | ||
1/1 | 1 | 26 | Connector P4/ |
1/2 | 2 | 27 | |
1/3 | 3 | 28 | |
1/4 | 4 | 29 | |
2/1 | 5 | 30 | |
2/2 | 6 | 31 | |
2/3 | 7 | 32 | |
2/4 | 8 | 33 | |
3/1 | 9 | 34 | |
3/2 | 10 | 35 | |
3/3 | 11 | 36 | |
3/4 | 12 | 37 | |
4/1 | 13 | 38 | |
4/2 | 14 | 39 | |
4/3 | 15 | 40 | |
4/4 | 16 | 41 | |
5/1 | 17 | 42 | |
5/2 | 18 | 43 | |
5/3 | 19 | 44 | |
5/4 | 20 | 45 | |
6/1 | 21 | 46 | |
6/2 | 22 | 47 | |
6/3 | 23 | 48 | |
6/4 | 24 | 49 | |
7/1 | 1 | 26 | Connector P5/ |
7/2 | 2 | 27 | |
7/3 | 3 | 28 | |
7/4 | 4 | 29 | |
8/1 | 5 | 30 | |
8/2 | 6 | 31 | |
8/3 | 7 | 32 | |
8/4 | 8 | 33 | |
13/1 | 1 | 26 | Connector P1/ |
13/2 | 2 | 27 | |
13/3 | 3 | 28 | |
13/4 | 4 | 29 | |
14/1 | 5 | 30 | |
14/2 | 6 | 31 | |
14/3 | 7 | 32 | |
14/4 | 8 | 33 | |
15/1 | 9 | 34 | |
15/2 | 10 | 35 | |
15/3 | 11 | 36 | |
15/4 | 12 | 37 | |
16/1 | 13 | 38 | |
16/2 | 14 | 39 | |
16/3 | 15 | 40 | |
16/4 | 16 | 41 | |
17/1 | 17 | 42 | |
17/2 | 18 | 43 | |
17/3 | 19 | 44 | |
17/4 | 20 | 45 | |
18/1 | 21 | 46 | |
18/2 | 22 | 47 | |
18/3 | 23 | 48 | |
18/4 | 24 | 49 | |
19/1 | 1 | 26 | Connector P2/ |
19/2 | 2 | 27 | |
19/3 | 3 | 28 | |
19/4 | 4 | 29 | |
20/1 | 5 | 30 | |
20/2 | 6 | 31 | |
20/3 | 7 | 32 | |
20/4 | 8 | 33 | |
21/1 | 9 | 34 | Connector P5/ |
21/2 | 10 | 35 | |
21/3 | 11 | 36 | |
21/4 | 12 | 37 | |
22/1 | 13 | 38 | |
22/2 | 14 | 39 | |
22/3 | 15 | 40 | |
22/4 | 16 | 41 | |
23/1 | 17 | 42 | |
23/2 | 18 | 43 | |
23/3 | 19 | 44 | |
23/4 | 20 | 45 | |
24/1 | 21 | 46 | |
24/2 | 22 | 47 | |
24/3 | 23 | 48 | |
24/4 | 24 | 49 | |
25/1 | 1 | 26 | Connector P6/ |
25/2 | 2 | 27 | |
25/3 | 3 | 28 | |
25/4 | 4 | 29 | |
26/1 | 5 | 30 | |
26/2 | 6 | 31 | |
26/3 | 7 | 32 | |
26/4 | 8 | 33 | |
27/1 | 9 | 34 | |
27/2 | 10 | 35 | |
27/3 | 11 | 36 | |
27/4 | 12 | 37 | |
28/1 | 13 | 38 | |
28/2 | 14 | 39 | |
28/3 | 15 | 40 | |
28/4 | 16 | 41 | |
31/1 | 9 | 34 | Connector P2/ |
31/2 | 10 | 35 | |
31/3 | 11 | 36 | |
31/4 | 12 | 37 | |
32/1 | 13 | 38 | |
32/2 | 14 | 39 | |
32/3 | 15 | 40 | |
32/4 | 16 | 41 | |
33/1 | 17 | 42 | |
33/2 | 18 | 43 | |
33/3 | 19 | 44 | |
33/4 | 20 | 45 | |
34/1 | 21 | 46 | |
34/2 | 22 | 47 | |
34/3 | 23 | 48 | |
34/4 | 24 | 49 | |
35/1 | 1 | 26 | Connector P3/ |
35/2 | 2 | 27 | |
35/3 | 3 | 28 | |
35/4 | 4 | 29 | |
36/1 | 5 | 30 | |
36/2 | 6 | 31 | |
36/3 | 7 | 32 | |
36/4 | 8 | 33 | |
37/1 | 9 | 34 | |
37/2 | 10 | 35 | |
37/3 | 11 | 36 | |
37/4 | 12 | 37 | |
38/1 | 13 | 38 | |
38/2 | 14 | 39 | |
38/3 | 15 | 40 | |
38/4 | 16 | 41 | |
Table D-7 maps the Cisco 6100 ports, the Cisco 6110 ports, and the wire pairs when using the one-to-one cables (see Table C-10) for a DOH configuration.
| Cisco 6110 Slot/Line | Cisco 6120 Slot/Line | Champ Pins | Cisco 6120 MDF/POTS Connections | |
|---|---|---|---|---|
| Tip | Ring | |||
1/1 | 1/1 | 9 | 34 | J11/J7 |
1/2 | 1/2 | 10 | 35 | |
1/3 | 1/3 | 11 | 36 | |
1/4 | 1/4 | 12 | 37 | |
2/1 | 2/1 | 5 | 30 | |
2/2 | 2/2 | 6 | 31 | |
2/3 | 2/3 | 7 | 32 | |
2/4 | 2/4 | 8 | 33 | |
3/1 | 3/1 | 1 | 26 | |
3/2 | 3/2 | 2 | 27 | |
3/3 | 3/3 | 3 | 28 | |
3/4 | 3/4 | 4 | 29 | |
4/1 | 4/1 | 18 | 43 | |
4/2 | 4/2 | 19 | 44 | |
4/3 | 4/3 | 20 | 45 | |
4/4 | 4/4 | 21 | 46 | |
5/1 | 5/1 | 22 | 47 | |
5/2 | 5/2 | 23 | 48 | |
5/3 | 5/3 | 24 | 49 | |
5/4 | 5/4 | 25 | 50 | |
18/1 | 18/1 | 22 | 47 | J14/J8 |
18/2 | 18/2 | 23 | 48 | |
18/3 | 18/3 | 24 | 49 | |
18/4 | 18/4 | 17 | 42 | |
19/1 | 19/1 | 18 | 43 | |
19/2 | 19/2 | 19 | 44 | |
19/3 | 19/3 | 20 | 45 | |
19/4 | 19/4 | 21 | 46 | |
20/1 | 20/1 | 1 | 26 | |
20/2 | 20/2 | 2 | 27 | |
20/3 | 20/3 | 3 | 28 | |
20/4 | 20/4 | 4 | 29 | |
21/1 | 21/1 | 5 | 30 | |
21/2 | 21/2 | 6 | 31 | |
21/3 | 21/3 | 7 | 32 | |
21/4 | 21/4 | 8 | 33 | |
22/1 | 22/1 | 9 | 34 | |
22/2 | 22/2 | 10 | 35 | |
22/3 | 22/3 | 11 | 36 | |
22/4 | 22/4 | 12 | 37 | |
6/1 | 6/1 | 6 | 31 | J12/J9 |
6/2 | 6/2 | 7 | 32 | |
6/3 | 6/3 | 8 | 33 | |
6/4 | 6/4 | 9 | 34 | |
7/1 | 7/1 | 2 | 27 | |
7/2 | 7/2 | 3 | 28 | |
7/3 | 7/3 | 4 | 29 | |
7/4 | 7/4 | 5 | 30 | |
8/1 | 8/1 | 1 | 26 | |
8/2 | 8/2 | 10 | 35 | |
8/3 | 8/3 | 11 | 36 | |
8/4 | 8/4 | 12 | 37 | |
15/1 | 15/1 | 1 | 26 | J13/J10 |
15/2 | 15/2 | 10 | 35 | |
15/3 | 15/3 | 11 | 36 | |
15/4 | 15/4 | 12 | 37 | |
16/1 | 16/1 | 2 | 27 | |
16/2 | 16/2 | 3 | 28 | |
16/3 | 16/3 | 4 | 29 | |
16/4 | 16/4 | 5 | 30 | |
17/1 | 17/1 | 6 | 31 | |
17/2 | 17/2 | 7 | 32 | |
17/3 | 17/3 | 8 | 33 | |
17/4 | 17/4 | 9 | 34 | |
Table D-8 maps the Cisco 6110 ports, the Cisco 6120 ports, and the wire pairs when using the two-to-two cables (see Table C-11) for a DOH configuration. The corresponding cable kit number is CAB-PSC-80-REPIN.
You can use the two-to-two cables to clearly associate the mapping between the wire pairs and the Cisco 6100 and Cisco 6120 ports. These cables attach to the Cisco 6120 MDF connections (J11 to J14) and the Cisco 6120 POTS connections (J7 to J10) for systems using dual-port xTU-C modules.
| Cisco 6110 Slot/Line | Cisco 6120 Slot/Line | Champ Pins | Cable Connector | |
|---|---|---|---|---|
| Tip | Ring | |||
1/1 | 1/1 | 1 | 26 | P1 |
1/2 | 1/2 | 2 | 27 | |
2/1 | 1/3 | 3 | 28 | |
2/2 | 1/4 | 4 | 29 | |
3/1 | 2/1 | 5 | 30 | |
3/2 | 2/2 | 6 | 31 | |
4/1 | 2/3 | 7 | 32 | |
4/2 | 2/4 | 8 | 33 | |
5/1 | 3/1 | 9 | 34 | |
5/2 | 3/2 | 10 | 35 | |
6/1 | 3/3 | 11 | 36 | |
6/2 | 3/4 | 12 | 37 | |
7/1 | 4/1 | 13 | 38 | |
7/2 | 4/2 | 14 | 39 | |
8/1 | 4/3 | 15 | 40 | |
8/2 | 4/4 | 16 | 41 | |
13/1 | 19/1 | 1 | 26 | P2 |
13/2 | 19/2 | 2 | 27 | |
14/1 | 19/3 | 3 | 28 | |
14/2 | 19/4 | 4 | 29 | |
15/1 | 20/1 | 5 | 30 | |
15/2 | 20/2 | 6 | 31 | |
16/1 | 20/3 | 7 | 32 | |
16/2 | 20/4 | 8 | 33 | |
17/1 | 21/1 | 9 | 34 | |
17/2 | 21/2 | 10 | 35 | |
18/1 | 21/3 | 11 | 36 | |
18/2 | 21/4 | 12 | 37 | |
19/1 | 22/1 | 13 | 38 | |
19/2 | 22/2 | 14 | 39 | |
20/1 | 22/3 | 15 | 40 | |
20/2 | 22/4 | 16 | 41 | |
21/1 | 5/1 | 1 | 26 | P3 |
21/2 | 5/2 | 2 | 27 | |
22/1 | 5/3 | 3 | 28 | |
22/2 | 5/4 | 4 | 29 | |
23/1 | 6/1 | 5 | 30 | |
23/2 | 6/2 | 6 | 31 | |
24/1 | 6/3 | 7 | 32 | |
24/2 | 6/4 | 8 | 33 | |
25/1 | 7/1 | 9 | 34 | |
25/2 | 7/2 | 10 | 35 | |
26/1 | 7/3 | 11 | 36 | |
26/2 | 7/4 | 12 | 37 | |
27/1 | 8/1 | 13 | 38 | |
27/2 | 8/2 | 14 | 39 | |
28/1 | 8/3 | 15 | 40 | |
28/2 | 8/4 | 16 | 41 | |
31/1 | 15/1 | 1 | 26 | P4 |
31/2 | 15/2 | 2 | 27 | |
32/1 | 15/3 | 3 | 28 | |
32/2 | 15/4 | 4 | 29 | |
33/1 | 16/1 | 5 | 30 | |
33/2 | 16/2 | 6 | 31 | |
34/1 | 16/3 | 7 | 32 | |
34/2 | 16/4 | 8 | 33 | |
35/1 | 17/1 | 9 | 34 | |
35/2 | 17/2 | 10 | 35 | |
36/1 | 17/3 | 11 | 36 | |
36/2 | 17/4 | 12 | 37 | |
37/1 | 18/1 | 13 | 38 | |
37/2 | 18/2 | 14 | 39 | |
38/1 | 18/3 | 15 | 40 | |
38/2 | 18/4 | 16 | 41 | |
Table D-9 provides the Champ pins and Cisco 6100/6130 port mapping information needed to build your own chassis cables.
| Connector | Champ Pins | Cisco 6100/6130 Slot/Line | |
|---|---|---|---|
| Tip | Ring | ||
J39 xDSL Slots 3 through 8 (pins 25 and 50 are not used) | 1 | 2 | 6/1 |
3 | 4 | 6/2 | |
5 | 6 | 6/3 | |
7 | 8 | 6/4 | |
9 | 10 | 7/1 | |
11 | 12 | 7/2 | |
13 | 14 | 7/3 | |
15 | 16 | 7/4 | |
17 | 18 | 8/1 | |
19 | 20 | 8/2 | |
21 | 22 | 8/3 | |
23 | 24 | 8/4 | |
26 | 27 | 5/1 | |
28 | 29 | 5/2 | |
30 | 31 | 5/3 | |
32 | 33 | 5/4 | |
34 | 35 | 4/1 | |
36 | 37 | 4/2 | |
38 | 39 | 4/3 | |
40 | 41 | 4/4 | |
42 | 43 | 3/1 | |
44 | 45 | 3/2 | |
46 | 47 | 3/3 | |
48 | 49 | 3/4 | |
J40 xDSL Slots 1, 2, 21, and 22 (pins 9 through 25 are not used) | 1 | 2 | 22/1 |
3 | 4 | 22/2 | |
5 | 6 | 22/3 | |
7 | 8 | 22/4 | |
26 | 27 | 21/1 | |
28 | 29 | 21/2 | |
30 | 31 | 21/3 | |
32 | 33 | 21/4 | |
34 | 35 | 2/1 | |
36 | 37 | 2/2 | |
38 | 39 | 2/3 | |
40 | 41 | 2/4 | |
42 | 43 | 1/1 | |
44 | 45 | 1/2 | |
46 | 47 | 1/3 | |
48 | 49 | 1/4 | |
J41 xDSL Slots 23 through 23 (pins 25 and 50 are not used) | 1 | 2 | 26/1 |
3 | 4 | 26/2 | |
5 | 6 | 26/3 | |
7 | 8 | 26/4 | |
9 | 10 | 27/1 | |
11 | 12 | 27/2 | |
13 | 14 | 27/3 | |
15 | 16 | 27/4 | |
17 | 18 | 28/1 | |
19 | 20 | 28/2 | |
21 | 22 | 28/3 | |
23 | 24 | 28/4 | |
26 | 27 | 25/1 | |
28 | 29 | 25/2 | |
30 | 31 | 25/3 | |
32 | 33 | 25/4 | |
34 | 35 | 24/1 | |
36 | 37 | 24/2 | |
38 | 39 | 24/3 | |
40 | 41 | 24/4 | |
42 | 43 | 23/1 | |
44 | 45 | 23/2 | |
46 | 47 | 23/3 | |
48 | 49 | 23/4 | |
J42 xDSL Slots 13 through 18 (pins 25 and 50 are not used) | 1 | 2 | 17/1 |
3 | 4 | 17/2 | |
5 | 6 | 17/3 | |
7 | 8 | 17/4 | |
9 | 10 | 18/1 | |
11 | 12 | 18/2 | |
13 | 14 | 18/3 | |
15 | 16 | 18/4 | |
17 | 18 | 13/1 | |
19 | 20 | 13/2 | |
21 | 22 | 13/3 | |
23 | 24 | 13/4 | |
26 | 27 | 16/1 | |
28 | 29 | 16/2 | |
30 | 31 | 16/3 | |
32 | 33 | 16/4 | |
34 | 35 | 15/1 | |
36 | 37 | 15/2 | |
38 | 39 | 15/3 | |
40 | 41 | 15/4 | |
42 | 43 | 14/1 | |
44 | 45 | 14/2 | |
46 | 47 | 14/3 | |
48 | 49 | 14/4 | |
J43 xDSL Slots 19, 20, 37, and 38 (pins 9 through 25 and 50 are not used) | 1 | 2 | 20/1 |
3 | 4 | 20/2 | |
5 | 6 | 20/3 | |
7 | 8 | 20/4 | |
26 | 27 | 19/1 | |
28 | 29 | 19/2 | |
30 | 31 | 19/3 | |
32 | 33 | 19/4 | |
34 | 35 | 38/1 | |
36 | 37 | 38/2 | |
38 | 39 | 38/3 | |
40 | 41 | 38/4 | |
42 | 43 | 37/1 | |
44 | 45 | 37/2 | |
46 | 47 | 37/3 | |
48 | 49 | 37/4 | |
J44 xDSL Slots 31 through 36 (pins 25 and 50 are not used) | 1 | 2 | 35/1 |
3 | 4 | 35/2 | |
5 | 6 | 35/3 | |
7 | 8 | 35/4 | |
9 | 10 | 36/1 | |
11 | 12 | 36/2 | |
13 | 14 | 36/3 | |
15 | 16 | 36/4 | |
17 | 18 | 31/1 | |
19 | 20 | 31/2 | |
21 | 22 | 31/3 | |
23 | 24 | 31/4 | |
26 | 27 | 34/1 | |
28 | 29 | 34/2 | |
30 | 31 | 34/3 | |
32 | 33 | 34/4 | |
34 | 35 | 33/1 | |
36 | 37 | 33/2 | |
38 | 39 | 33/3 | |
40 | 41 | 33/4 | |
42 | 43 | 32/1 | |
44 | 45 | 32/2 | |
46 | 47 | 32/3 | |
48 | 49 | 32/4 | |
In designing the cables for the Cisco 6100 Series connections, Cisco used a standard telco color chart. Table D-10 lists the colors used for the Cisco 6100 Series cables.
| Wire Color | P1 | Wire Color | P2 | Wire Color | P1 | Wire Color | P2 | |
|---|---|---|---|---|---|---|---|---|
Wht/blu | 1 | Wht/blu | 1 |
| Grn/blk | 38 | Grn/blk | 38 |
Blu/wht | 26 | Blu/wht | 26 |
| Blk/brn | 14 | Blk/brn | 14 |
Wht/org | 2 | Wht/org | 2 |
| Brn/blk | 39 | Brn/blk | 39 |
Org/wht | 27 | Org/wht | 27 |
| Blk/gry | 15 | Blk/gry | 15 |
Wht/grn | 3 | Wht/grn | 3 |
| Gry/blk | 40 | Gry/blk | 40 |
Grn/wht | 28 | Grn/wht | 28 |
| Yel/blu | 16 | Yel/blu | 16 |
Wht/brn | 4 | Wht/brn | 4 |
| Blu/yel | 41 | Blu/yel | 41 |
Brn/wht | 29 | Brn/wht | 29 |
| Yel/org | 17 | Yel/org | 17 |
Wht/gry | 5 | Wht/gry | 5 |
| Org/yel | 42 | Org/yel | 42 |
Gry/wht | 30 | Gry/wht | 30 |
| Yel/grn | 18 | Yel/grn | 18 |
Red/blu | 6 | Red/blu | 6 |
| Grn/yel | 43 | Grn/yel | 43 |
Blu/red | 31 | Blu/red | 31 |
| Yel/brn | 19 | Yel/brn | 19 |
Red/org | 7 | Red/org | 7 |
| Brn/yel | 44 | Brn/yel | 44 |
Org/red | 32 | Org/red | 32 |
| Yel/gry | 20 | Yel/gry | 20 |
Red/grn | 8 | Red/grn | 8 |
| Gry/yel | 45 | Gry/yel | 45 |
Grn/red | 33 | Grn/red | 33 |
| Vio/blu | 21 | Vio/blu | 21 |
Red/brn | 9 | Red/brn | 9 |
| Blu/vio | 46 | Blu/vio | 46 |
Brn/red | 34 | Brn/red | 34 |
| Vio/org | 22 | Vio/org | 22 |
Red/gry | 10 | Red/gry | 10 |
| Org/vio | 47 | Org/vio | 47 |
Gry/red | 35 | Gry/red | 35 |
| Vio/grn | 23 | Vio/grn | 23 |
Blk/blu | 11 | Blk/blu | 11 |
| Grn/vio | 48 | Grn/vio | 48 |
Blu/blk | 36 | Blu/blk | 36 |
| Vio/brn | 24 | Vio/brn | 24 |
Blk/org | 12 | Blk/org | 12 |
| Brn/vio | 49 | Brn/vio | 49 |
Org/blk | 37 | Org/blk | 37 |
| Vio/gry | 25 | Vio/gry | 25 |
Blk/grn | 13 | Blk/grn | 13 |
| Gry/vio | 50 | Gry/vio | 50 |
![]()
![]()
![]()
![]()
![]()
![]()
![]()