This chapter explains how to diagnose and handle line (LIM port) events that are generated by the Cisco 6100 Series system. The following information is presented for each of the events:
If none of the actions presented for the event are successful, contact the Cisco Technical Assistance Center (TAC) for additional support.
![]() |
Note Refer to the ViewRunner for Windows User Guide or the ViewRunner for HP OpenView User Guide for detailed information on viewing events in the ViewRunner management software. Refer to "Event Guidelines and Definitions" for detailed information on event severity guidelines and alarm event status changes. |
Table 13-1 lists line (LIM port) events and their IDs, definition, severity, and description. A detailed explanation of these events and the corrective actions that are required (if any) is located in this chapter.
| ID | Definition | Severity | Description |
|---|---|---|---|
1 | CCNX_OLD_CPE_DETECT | Major | Improper version signature on CPE modem |
2 | LINE_LOCKOUT | Minor | Line disconnected due to session length |
3 | LINE_IDLE_TIMEOUT | Info | Line disconnected due to inactivity |
![]() |
Note Events with an ID less than 128 are specific to the module in alarm. Events with an ID value greater than or equal to 128 are system-wide events. |
| ID | Event Name | Severity |
|---|---|---|
1 | CCNX_OLD_CPE_DETECT | Major |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Improper version signature on CPE modemThe CPE detection feature is used to discover CPE gear that is not capable of performing Idle or Session timeouts. During training, the CPE detection feature determines if the CPE equipment can be timer enabled. If the equipment can be timer enabled, training will continue. If the equipment cannot be timer enabled, an alarm is generated in ViewRunner and training will not be successful until the Cisco 600 Series CPE device is updated to at least version 2.0.1. The line port or modem port will not train successfully until the Cisco 600 Series CPE device is updated to at least version 2.0.1.
Either lower the CPE detect/reject feature to zero or upgrade the CPE to at least version 2.1.0.
| ID | Event Name | Severity |
|---|---|---|
2 | LINE_LOCKOUT | Minor |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Line disconnected due to session lengthThe CPE device session timer expired and the CPE disconnected.
No action is required. To reconnect, wait until the time specified by the lockout timer elapses. The default lockout time is 5 minutes.
| ID | Event Name | Severity |
|---|---|---|
3 | LINE_IDLE_TIMEOUT | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Line disconnected due to inactivityThe user is disconnected when the line is idle for the time specified by the idle timer.
No action is required. The line can be reestablished by clicking in the web browser.
![]()
![]()
![]()
![]()
![]()
![]()
![]()