DS3 Subtend Host Module Events

This chapter explains how to diagnose and handle DS3 subtend host module (STM) events that are generated by the Cisco 6100 Series system. The following information is presented for each of the events:

If none of the actions presented for the event are successful, contact the Cisco Technical Assistance Center (TAC) for additional support.


Note Refer to the ViewRunner for Windows User Guide or the ViewRunner for HP OpenView User Guide for detailed information on viewing events in the ViewRunner management software. Refer to "Event Guidelines and Definitions" for detailed information on event severity guidelines and alarm event status changes.

Table 11-1 lists DS3 STM events and their IDs, definition, severity, and description. A detailed explanation of these events and the corrective actions that are required (if any) is located in this chapter.


Table 11-1: DS3 Subtend Host Module Events
ID Definition Severity Description

128

LR_CREATE_OBJ

Info

Module was detected

129

LR_PING_FAIL

Critical

Module did not respond to the system monitor

42

FC_SUBTEND_PORT_BUFFER_OVERFLOW

Info

Buffer overflow in the cell buffer on the subtend module

43

FC_SUBTEND_PORT_UTOPIA_ERROR

Info

Error in UTOPIA chip

44

FC_SUBTEND_PORT_INGRESS_HEC

Info

Subtend port ingress HEC error


Note Events with an ID less than 128 are specific to the module in alarm. Events with an ID value greater than or equal to 128 are system-wide events.

Module was Detected

Event Summary

ID Event Name Severity

128

LR_CREATE_OBJ

Info

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

Module was detected

Impact

Events of this type do not indicate service impairment or loss.

Action

This is an information event, not an alarm event. Information events do not represent a state change and therefore are not followed by a Cleared event.

Information events are typically one-time occurrences that are corrected by the module without a reset. They do not cause service degradation.

No craft action is required.

Module did not Respond to System Monitor

Event Summary

ID Event Name Severity

129

LR_PING_FAIL

Critical

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

Module did not respond to the system monitor

Impact

Events of this type are normally coded as minor, but are currently are maintained as critical. This is done to preserve the node software's requirement to decouple event severity from service state impact.

Action

In some cases, a module forces itself into a self-test based on the alarm condition. In other cases, the system controller module forces the alarmed module to reset. A module reset forces the module to be power cycled, self-tested, and reconfigured into the slot by the system controller module.

Several alarm event conditions are cleared by a module reset. Look for the alarm event to clear within 1 minute. An alarm event is cleared when the system controller module faceplate ALARM LED changes from red to off.

In the ViewRunner management software, two actions show that an alarm event is cleared:

If the alarm event does not clear:


Step 1 Remove and reinsert the module. This forces a module to reset if neither the module nor the system controller module could force a reset. A module reset usually clears all alarm conditions.

Step 2 Observe the system controller module ALARM LED or the ViewRunner ejector tabs to see if the alarm condition returns. If the previous problem persists, the condition will probably reoccur within 1 minute.

Step 3 If the alarm condition persists, replace the module.


Buffer Overflow in Cell Buffer on Subtend Module

Event Summary

ID Event Name Severity

42

FC_SUBTEND_PORT_BUFFER_OVERFLOW

Info

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

Buffer overflow in the cell buffer on the subtend module

Impact

An alarm event of this type will likely result in the loss of a single cell. Loss of a single cell is a transient event, affecting only one subscriber. Recovery is possible at higher layers in the protocol stack. Multiple occurrences of the alarm event are more serious and typically indicate the failure of a hardware component on the network interface module.

The term multiple occurrences is applied if several occurrences take place within a few seconds. If a problem with cell loss, and ultimately subscriber traffic throughout is suspected, service personnel should review the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser for multiple occurrences. In a future software release, multiple occurrences of events in this category will generate a higher severity alarm.

Action

Alarm events of this type are typically caused by short-term (milliseconds in duration) incidents that clear as part of the normal course of traffic management. Examples of traffic management events include the freeing of buffer space, recovery from parity errors at a higher level, and recover after a brief loss of signal.

Each of these alarm events is followed by an additional event showing a Cleared event status, meaning the alarm event has been corrected.


Step 1 If a Cleared event status is not received within 1 minute, reinsert the module.

Step 2 If a problem persists, replace the module.


Error in UTOPIA Chip

Event Summary

ID Event Name Severity

43

FC_SUBTEND_PORT_UTOPIA_ERROR

Info

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

Error in UTOPIA chip

Impact

An alarm event of this type will likely result in the loss of a single cell. Loss of a single cell is a transient event, affecting only one subscriber. Recovery is possible at higher layers in the protocol stack. Multiple occurrences of the alarm event are more serious and typically indicate the failure of a hardware component on the network interface module.

The term multiple occurrences is applied if several occurrences take place within a few seconds. If a problem with cell loss, and ultimately subscriber traffic throughout is suspected, service personnel should review the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser for multiple occurrences. In a future software release, multiple occurrences of events in this category will generate a higher severity alarm.

Action

This is an information event, not an alarm event. Information events do not represent a state change and therefore are not followed by a Cleared event.

Information events are typically one-time occurrences that are corrected by the module without a reset. They do not cause service degradation.

No craft action is required.

Subtend Port Ingress HEC Error

Event Summary

ID Event Name Severity

44

FC_SUBTEND_PORT_INGRESS_HEC

Info

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

Subtend port ingress HEC error

Impact

An alarm event of this type will likely result in the loss of a single cell. Loss of a single cell is a transient event, affecting only one subscriber. Recovery is possible at higher layers in the protocol stack. Multiple occurrences of the alarm event are more serious and typically indicate the failure of a hardware component on the network interface module.

The term multiple occurrences is applied if several occurrences take place within a few seconds. If a problem with cell loss, and ultimately subscriber traffic throughout is suspected, service personnel should review the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser for multiple occurrences. In a future software release, multiple occurrences of events in this category will generate a higher severity alarm.

Action

This is an information event, not an alarm event. Information events do not represent a state change and therefore are not followed by a Cleared event.

Information events are typically one-time occurrences that are corrected by the module without a reset. They do not cause service degradation.

No craft action is required.