This appendix provides connectors, pinouts, and port mapping tables for a Direct Connect configuration of the Cisco 6100 Series system.
For a list of Direct Connect configuration cables and their respective Cisco part numbers, see "Cabling for a Direct Connect Configuration."
This section describes multiplexer chassis (MC) connectors and pinouts for the following:
The backplane of the MC contains six Champ connectors which connect to the xTU-C twisted-pair subscriber data interface. This connection can be made by either of the following:
Figure B-1 shows connector pin locations for the xDSL Champ connectors. Pin locations are the same for all Champ connectors.

Use the terminal block connector to wire the MC to the power source on the fuse and alarm panel. For more information on fusing, see one of the following:
The terminal block connectors will accept 14 to 18 American Wire Gauge (AWG) copper solid or stranded wire. Figure B-2 shows the Cisco 6100 Series power terminal block.

The Cisco 6100 Series system provides alarm contacts for audible, visual, and E2A alarm connections. These contacts support minor, major, and critical alarm reporting. (Figure B-3 shows the alarm contacts.)

Table B-1 lists the alarm contact pinouts shown in Figure B-3.
| Connector | Pin | Signal |
|---|---|---|
E2A
P14
| 1 | Critical_E2+ |
2 | Critical_E2- | |
3 | Major_E2+ | |
4 | Major_E2- | |
5 | Minor_E2+ | |
6 | Minor_E2- | |
7 | Fan Alarm+ | |
8 | Fan Alarm- | |
Visual
P15
| 1 | Critical_V+ |
2 | Critical_V- | |
3 | Major_V+ | |
4 | Major_V- | |
5 | Minor_V+ | |
6 | Minor_V- | |
7 | ACO_IN_V (future) | |
8 | ACO_RTN_V (future) | |
Audible
P17
| 1 | Critical_A+ |
2 | Critical_A- | |
3 | Major_A+ | |
4 | Major_A- | |
5 | Minor_A+ | |
6 | Minor_A- | |
7 | ACO_IN_A | |
8 | ACO_RTN_A |
For more information on the alarm contacts, see one of the following:
This section provides port mapping tables which show the wire pair and chassis port assignments for the following:
Table B-2 maps the MC ports, the PSC ports, and the wire pairs when using the one-to-one cables (see Table 3-2) for a Direct Connect with a PSC configuration. The corresponding cable kit number is CAB-61-014.
| MC Slot/Line | PSC Slot/Line | Champ Pins | PSC MDF1/POTS Connection | |
|---|---|---|---|---|
| Tip | Ring | |||
1/1 | 1/1 | 9 | 34 | J11/J7 |
1/2 | 1/2 | 10 | 35 | |
2/1 | 1/3 | 11 | 36 | |
2/2 | 1/4 | 12 | 37 | |
3/1 | 2/1 | 5 | 30 | |
3/2 | 2/2 | 6 | 31 | |
4/1 | 2/3 | 7 | 32 | |
4/2 | 2/4 | 8 | 33 | |
5/1 | 3/1 | 1 | 26 | |
5/2 | 3/2 | 2 | 27 | |
6/1 | 3/3 | 3 | 28 | |
6/2 | 3/4 | 4 | 29 | |
7/1 | 4/1 | 18 | 43 | |
7/2 | 4/2 | 19 | 44 | |
8/1 | 4/3 | 20 | 45 | |
8/2 | 4/4 | 21 | 46 | |
13/1 | 19/1 | 18 | 43 | J14/J8 |
13/2 | 19/2 | 19 | 44 | |
14/1 | 19/3 | 20 | 45 | |
14/2 | 19/4 | 21 | 46 | |
15/1 | 20/1 | 1 | 26 | |
15/2 | 20/2 | 2 | 27 | |
16/1 | 20/3 | 3 | 28 | |
16/2 | 20/4 | 4 | 29 | |
17/1 | 21/1 | 5 | 30 | |
17/2 | 21/2 | 6 | 31 | |
18/1 | 21/3 | 7 | 32 | |
18/2 | 21/4 | 8 | 33 | |
19/1 | 22/1 | 9 | 34 | |
19/2 | 22/2 | 10 | 35 | |
20/1 | 22/3 | 11 | 36 | |
20/2 | 22/4 | 12 | 37 | |
21/1 | 5/1 | 22 | 47 | J11/J7 |
21/2 | 5/2 | 23 | 48 | |
22/1 | 5/3 | 24 | 49 | |
22/2 | 5/4 | 25 | 50 | |
23/1 | 6/1 | 6 | 31 | J12/J9 |
23/2 | 6/2 | 7 | 32 | |
24/1 | 6/3 | 8 | 33 | |
24/2 | 6/4 | 9 | 34 | |
25/1 | 7/1 | 2 | 27 | |
25/2 | 7/2 | 3 | 28 | |
26/1 | 7/3 | 4 | 29 | |
26/2 | 7/4 | 5 | 30 | |
27/1 | 8/1 | 1 | 26 | |
27/2 | 8/2 | 10 | 35 | |
28/1 | 8/3 | 11 | 36 | |
28/2 | 8/4 | 12 | 37 | |
31/1 | 15/1 | 1 | 26 | J13/J10 |
31/2 | 15/2 | 10 | 35 | |
32/1 | 15/3 | 11 | 36 | |
32/2 | 15/4 | 12 | 37 | |
33/1 | 16/1 | 2 | 27 | |
33/2 | 16/2 | 3 | 28 | |
34/1 | 16/3 | 4 | 29 | |
34/2 | 16/4 | 5 | 30 | |
35/1 | 17/1 | 6 | 31 | |
35/2 | 17/2 | 7 | 32 | |
36/1 | 17/3 | 8 | 33 | |
36/2 | 17/4 | 9 | 34 | |
37/1 | 18/1 | 22 | 47 | J14/J8 |
37/2 | 18/2 | 23 | 48 | |
38/1 | 18/3 | 24 | 49 | |
38/2 | 18/4 | 25 | 50 | |
| 1MDF = main distribution frame |
Table B-3 maps the MC ports, the PSC ports for two PSCs, and the wire pairs when using the two-to-one cables (see Table 3-3) for a Direct Connect with a PSC configuration. The corresponding cable kit number is CAB-MC128-PSC80. You can use the two-to-one cables to connect one MC to two PSCs for systems using quad-port ATU-C modules.
| MC Slot/Line | PSC Slot/Line | Champ Pins | PSC MDF/ POTS Connection | ||
|---|---|---|---|---|---|
| PSC 1 | PSC 2 | Tip | Ring | ||
1/1 | 1/1 | --- | 9 | 34 | J11/J7 |
1/2 | 1/2 | --- | 10 | 35 | |
1/3 | --- | 1/1 | 9 | 34 | |
1/4 | --- | 1/2 | 10 | 35 | |
2/1 | 1/3 | --- | 11 | 36 | |
2/2 | 1/4 | --- | 12 | 37 | |
2/3 | --- | 1/3 | 11 | 36 | |
2/4 | --- | 1/4 | 12 | 37 | |
3/1 | 2/1 | --- | 5 | 30 | |
3/2 | 2/2 | --- | 6 | 31 | |
3/3 | --- | 2/1 | 5 | 30 | |
3/4 | --- | 2/2 | 6 | 31 | |
4/1 | 2/3 | --- | 7 | 32 | |
4/2 | 2/4 | --- | 8 | 33 | |
4/3 | --- | 2/3 | 7 | 32 | |
4/4 | --- | 2/4 | 8 | 33 | |
5/1 | 3/1 | --- | 1 | 26 | |
5/2 | 3/2 | --- | 2 | 27 | |
5/3 | --- | 3/1 | 1 | 26 | |
5/4 | --- | 3/2 | 2 | 27 | |
6/1 | 3/3 | --- | 3 | 28 | |
6/2 | 3/4 | --- | 4 | 29 | |
6/3 | --- | 3/3 | 3 | 28 | |
6/4 | --- | 3/4 | 4 | 29 | |
7/1 | 4/1 | --- | 18 | 43 | |
7/2 | 4/2 | --- | 19 | 44 | |
7/3 | --- | 4/1 | 18 | 43 | |
7/4 | --- | 4/2 | 19 | 44 | |
8/1 | 4/3 | --- | 20 | 45 | |
8/2 | 4/4 | --- | 21 | 46 | |
8/3 | --- | 4/3 | 20 | 45 | |
8/4 | --- | 4/4 | 21 | 46 | |
13/1 | 19/1 | --- | 18 | 43 | J14/J8 |
13/2 | 19/2 | --- | 19 | 44 | |
13/3 | --- | 19/1 | 18 | 43 | |
13/4 | --- | 19/2 | 19 | 44 | |
14/1 | 19/3 | --- | 20 | 45 | |
14/2 | 19/4 | --- | 21 | 46 | |
14/3 | --- | 19/3 | 20 | 45 | |
14/4 | --- | 19/4 | 21 | 46 | |
15/1 | 20/1 | --- | 1 | 26 | |
15/2 | 20/2 | --- | 2 | 27 | |
15/3 | --- | 20/1 | 1 | 26 | |
15/4 | --- | 20/2 | 2 | 27 | |
16/1 | 20/3 | --- | 3 | 28 | |
16/2 | 20/4 | --- | 4 | 29 | |
16/3 | --- | 20/3 | 3 | 28 | |
16/4 | --- | 20/4 | 4 | 29 | |
17/1 | 21/1 | --- | 5 | 30 | |
17/2 | 21/2 | --- | 6 | 31 | |
17/3 | --- | 21/1 | 5 | 30 | |
17/4 | --- | 21/2 | 6 | 31 | |
18/1 | 21/3 | --- | 7 | 32 | |
18/2 | 21/4 | --- | 8 | 33 | |
18/3 | --- | 21/3 | 7 | 32 | |
18/4 | --- | 21/4 | 8 | 33 | |
19/1 | 22/1 | --- | 9 | 34 | |
19/2 | 22/2 | --- | 10 | 35 | |
19/3 | --- | 22/1 | 9 | 34 | |
19/4 | --- | 22/2 | 10 | 35 | |
20/1 | 22/3 | --- | 11 | 36 | |
20/2 | 22/4 | --- | 12 | 37 | |
20/3 | --- | 22/3 | 11 | 36 | |
20/4 | --- | 22/4 | 12 | 37 | |
21/1 | 5/1 | --- | 22 | 47 | J11/J7 |
21/2 | 5/2 | --- | 23 | 48 | |
21/3 | --- | 5/1 | 22 | 47 | |
21/4 | --- | 5/2 | 23 | 48 | |
22/1 | 5/3 | --- | 24 | 49 | |
22/2 | 5/4 | --- | 25 | 50 | |
22/3 | --- | 5/3 | 24 | 49 | |
22/4 | --- | 5/4 | 25 | 50 | |
23/1 | 6/1 | --- | 6 | 31 | J12/J9 |
23/2 | 6/2 | --- | 7 | 32 | |
23/3 | --- | 6/1 | 6 | 31 | |
23/4 | --- | 6/2 | 7 | 32 | |
24/1 | 6/3 | --- | 8 | 33 | |
24/2 | 6/4 | --- | 9 | 34 | |
24/3 | --- | 6/3 | 8 | 33 | |
24/4 | --- | 6/4 | 9 | 34 | |
25/1 | 7/1 | --- | 2 | 27 | |
25/2 | 7/2 | --- | 3 | 28 | |
25/3 | --- | 7/1 | 2 | 27 | |
25/4 | --- | 7/2 | 3 | 28 | |
26/1 | 7/3 | --- | 4 | 29 | |
26/2 | 7/4 | --- | 5 | 30 | |
26/3 | --- | 7/3 | 4 | 29 | |
26/4 | --- | 7/4 | 5 | 30 | |
27/1 | 8/1 | --- | 1 | 26 | |
27/2 | 8/2 | --- | 10 | 35 | |
27/3 | --- | 8/1 | 1 | 26 | |
27/4 | --- | 8/2 | 10 | 35 | |
28/1 | 8/3 | --- | 11 | 36 | |
28/2 | 8/4 | --- | 12 | 37 | |
28/3 | --- | 8/3 | 11 | 36 | |
28/4 | --- | 8/4 | 12 | 37 | |
31/1 | 15/1 | --- | 1 | 26 | J13/J10 |
31/2 | 15/2 | --- | 10 | 35 | |
31/3 | --- | 15/1 | 1 | 26 | |
31/4 | --- | 15/2 | 10 | 35 | |
32/1 | 15/3 | --- | 11 | 36 | |
32/2 | 15/4 | --- | 12 | 37 | |
32/3 | --- | 15/3 | 11 | 36 | |
32/4 | --- | 15/4 | 12 | 37 | |
33/1 | 16/1 | --- | 2 | 27 | |
33/2 | 16/2 | --- | 3 | 28 | |
33/3 | --- | 16/1 | 2 | 27 | |
33/4 | --- | 16/2 | 3 | 28 | |
34/1 | 16/3 | --- | 4 | 29 | |
34/2 | 16/4 | --- | 5 | 30 | |
34/3 | --- | 16/3 | 4 | 29 | |
34/4 | --- | 16/4 | 5 | 30 | |
35/1 | 17/1 | --- | 6 | 31 | |
35/2 | 17/2 | --- | 7 | 32 | |
35/3 | --- | 17/1 | 6 | 31 | |
35/4 | --- | 17/2 | 7 | 32 | |
36/1 | 17/3 | --- | 8 | 33 | |
36/2 | 17/4 | --- | 9 | 34 | |
36/3 | --- | 17/3 | 8 | 33 | |
36/4 | --- | 17/4 | 9 | 34 | |
37/1 | 18/1 | --- | 22 | 47 | J14/J8 |
37/2 | 18/2 | --- | 23 | 48 | |
37/3 | --- | 18/1 | 22 | 47 | |
37/4 | --- | 18/2 | 23 | 48 | |
38/1 | 18/3 | --- | 24 | 49 | |
38/2 | 18/4 | --- | 25 | 50 | |
38/3 | --- | 18/3 | 24 | 49 | |
38/4 | --- | 18/4 | 25 | 50 | |
Table B-4 maps the MC ports, the PSC ports, and the wire pairs when using the two-to-two cables (see Table 3-5) for a Direct Connect with a PSC configuration. The corresponding cable kit number is CAB-PSC-80-REPIN.
You can use the two-to-two cables to clearly associate the mapping between the wire pairs and the MC/PSC ports. These cables attach to the PSC MDF connections (J11 to J14) and the PSC POTS connections (J7 to J10) for systems using dual-port xTU-C modules.
| MC Slot/Line | PSC Slot/Line | Champ Pins | Cable Connector | |
|---|---|---|---|---|
| Tip | Ring | |||
1/1 | 1/1 | 1 | 26 | P1 |
1/2 | 1/2 | 2 | 27 | |
2/1 | 1/3 | 3 | 28 | |
2/2 | 1/4 | 4 | 29 | |
3/1 | 2/1 | 5 | 30 | |
3/2 | 2/2 | 6 | 31 | |
4/1 | 2/3 | 7 | 32 | |
4/2 | 2/4 | 8 | 33 | |
5/1 | 3/1 | 9 | 34 | |
5/2 | 3/2 | 10 | 35 | |
6/1 | 3/3 | 11 | 36 | |
6/2 | 3/4 | 12 | 37 | |
7/1 | 4/1 | 13 | 38 | |
7/2 | 4/2 | 14 | 39 | |
8/1 | 4/3 | 15 | 40 | |
8/2 | 4/4 | 16 | 41 | |
13/1 | 19/1 | 1 | 26 | P2 |
13/2 | 19/2 | 2 | 27 | |
14/1 | 19/3 | 3 | 28 | |
14/2 | 19/4 | 4 | 29 | |
15/1 | 20/1 | 5 | 30 | |
15/2 | 20/2 | 6 | 31 | |
16/1 | 20/3 | 7 | 32 | |
16/2 | 20/4 | 8 | 33 | |
17/1 | 21/1 | 9 | 34 | |
17/2 | 21/2 | 10 | 35 | |
18/1 | 21/3 | 11 | 36 | |
18/2 | 21/4 | 12 | 37 | |
19/1 | 22/1 | 13 | 38 | |
19/2 | 22/2 | 14 | 39 | |
20/1 | 22/3 | 15 | 40 | |
20/2 | 22/4 | 16 | 41 | |
21/1 | 5/1 | 1 | 26 | P3 |
21/2 | 5/2 | 2 | 27 | |
22/1 | 5/3 | 3 | 28 | |
22/2 | 5/4 | 4 | 29 | |
23/1 | 6/1 | 5 | 30 | |
23/2 | 6/2 | 6 | 31 | |
24/1 | 6/3 | 7 | 32 | |
24/2 | 6/4 | 8 | 33 | |
25/1 | 7/1 | 9 | 34 | |
25/2 | 7/2 | 10 | 35 | |
26/1 | 7/3 | 11 | 36 | |
26/2 | 7/4 | 12 | 37 | |
27/1 | 8/1 | 13 | 38 | |
27/2 | 8/2 | 14 | 39 | |
28/1 | 8/3 | 15 | 40 | |
28/2 | 8/4 | 16 | 41 | |
31/1 | 15/1 | 1 | 26 | P4 |
31/2 | 15/2 | 2 | 27 | |
32/1 | 15/3 | 3 | 28 | |
32/2 | 15/4 | 4 | 29 | |
33/1 | 16/1 | 5 | 30 | |
33/2 | 16/2 | 6 | 31 | |
34/1 | 16/3 | 7 | 32 | |
34/2 | 16/4 | 8 | 33 | |
35/1 | 17/1 | 9 | 34 | |
35/2 | 17/2 | 10 | 35 | |
36/1 | 17/3 | 11 | 36 | |
36/2 | 17/4 | 12 | 37 | |
37/1 | 18/1 | 13 | 38 | |
37/2 | 18/2 | 14 | 39 | |
38/1 | 18/3 | 15 | 40 | |
38/2 | 18/4 | 16 | 41 | |
Table B-5 maps the MC ports and the wire pairs when using the two-to-three cables (see Table 3-6) for a Direct Connect without a PSC configuration. The corresponding cable kit number is CAB-MC-3:2-REPIN. You can use the two-to-three cables to connect the MC to the MDF for systems using dual-port DMT-2 ATU-C modules.
| MC Slot/Line | Champ Pins | Cable Connector/ Cable Part Number | |
|---|---|---|---|
| Tip | Ring | ||
1/1 | 1 | 26 | Connector P2/ |
1/2 | 2 | 27 | |
2/1 | 3 | 28 | |
2/2 | 4 | 29 | |
3/1 | 5 | 30 | |
3/2 | 6 | 31 | |
4/1 | 7 | 32 | |
4/2 | 8 | 33 | |
5/1 | 9 | 34 | |
5/2 | 10 | 35 | |
6/1 | 11 | 36 | |
6/2 | 12 | 37 | |
7/1 | 13 | 38 | |
7/2 | 14 | 39 | |
8/1 | 15 | 40 | |
8/2 | 16 | 41 | |
13/1 | 1 | 26 | Connector P2/ |
13/2 | 2 | 27 | |
14/1 | 3 | 28 | |
14/2 | 4 | 29 | |
15/1 | 5 | 30 | |
15/2 | 6 | 31 | |
16/1 | 7 | 32 | |
16/2 | 8 | 33 | |
17/1 | 9 | 34 | |
17/2 | 10 | 35 | |
18/1 | 11 | 36 | |
18/2 | 12 | 37 | |
19/1 | 13 | 38 | |
19/2 | 14 | 39 | |
20/1 | 15 | 40 | |
20/2 | 16 | 41 | |
21/1 | 1 | 26 | Connector P1/ |
21/2 | 2 | 27 | |
22/1 | 3 | 28 | |
22/2 | 4 | 29 | |
23/1 | 5 | 30 | |
23/2 | 6 | 31 | |
24/1 | 7 | 32 | |
24/2 | 8 | 33 | |
25/1 | 9 | 34 | |
25/2 | 10 | 35 | |
26/1 | 11 | 36 | |
26/2 | 12 | 37 | |
27/1 | 13 | 38 | |
27/2 | 14 | 39 | |
28/1 | 15 | 40 | |
28/2 | 16 | 41 | |
31/1 | 1 | 26 | Connector P1/ |
31/2 | 2 | 27 | |
32/1 | 3 | 28 | |
32/2 | 4 | 29 | |
33/1 | 5 | 30 | |
33/2 | 6 | 31 | |
34/1 | 7 | 32 | |
34/2 | 8 | 33 | |
35/1 | 9 | 34 | |
35/2 | 10 | 35 | |
36/1 | 11 | 36 | |
36/2 | 12 | 37 | |
37/1 | 13 | 38 | |
37/2 | 14 | 39 | |
38/1 | 15 | 40 | |
38/2 | 16 | 41 | |
Table B-6 maps the MC ports and the wire pairs when using the three-to-three cables (see Table 3-7) for a Direct Connect without a PSC configuration. The corresponding cable kit number is CAB-MC128-MDF. You can use the three-to-three cables to connect the MC to the MDF for systems using dual-port DMT-2 ATU-C or quad-port xTU-C modules.
| MC Slot/Line | Champ Pins | Cable Connector/ Cable Part Number | |
|---|---|---|---|
| Tip | Ring | ||
1/1 | 1 | 26 | Connector P4/ |
1/2 | 2 | 27 | |
1/3 | 3 | 28 | |
1/4 | 4 | 29 | |
2/1 | 5 | 30 | |
2/2 | 6 | 31 | |
2/3 | 7 | 32 | |
2/4 | 8 | 33 | |
3/1 | 9 | 34 | |
3/2 | 10 | 35 | |
3/3 | 11 | 36 | |
3/4 | 12 | 37 | |
4/1 | 13 | 38 | |
4/2 | 14 | 39 | |
4/3 | 15 | 40 | |
4/4 | 16 | 41 | |
5/1 | 17 | 42 | |
5/2 | 18 | 43 | |
5/3 | 19 | 44 | |
5/4 | 20 | 45 | |
6/1 | 21 | 46 | |
6/2 | 22 | 47 | |
6/3 | 23 | 48 | |
6/4 | 24 | 49 | |
7/1 | 1 | 26 | Connector P5/ |
7/2 | 2 | 27 | |
7/3 | 3 | 28 | |
7/4 | 4 | 29 | |
8/1 | 5 | 30 | |
8/2 | 6 | 31 | |
8/3 | 7 | 32 | |
8/4 | 8 | 33 | |
13/1 | 1 | 26 | Connector P1/ |
13/2 | 2 | 27 | |
13/3 | 3 | 28 | |
13/4 | 4 | 29 | |
14/1 | 5 | 30 | |
14/2 | 6 | 31 | |
14/3 | 7 | 32 | |
14/4 | 8 | 33 | |
15/1 | 9 | 34 | |
15/2 | 10 | 35 | |
15/3 | 11 | 36 | |
15/4 | 12 | 37 | |
16/1 | 13 | 38 | |
16/2 | 14 | 39 | |
16/3 | 15 | 40 | |
16/4 | 16 | 41 | |
17/1 | 17 | 42 | |
17/2 | 18 | 43 | |
17/3 | 19 | 44 | |
17/4 | 20 | 45 | |
18/1 | 21 | 46 | |
18/2 | 22 | 47 | |
18/3 | 23 | 48 | |
18/4 | 24 | 49 | |
19/1 | 1 | 26 | Connector P2/ |
19/2 | 2 | 27 | |
19/3 | 3 | 28 | |
19/4 | 4 | 29 | |
20/1 | 5 | 30 | |
20/2 | 6 | 31 | |
20/3 | 7 | 32 | |
20/4 | 8 | 33 | |
21/1 | 9 | 34 | Connector P5/ |
21/2 | 10 | 35 | |
21/3 | 11 | 36 | |
21/4 | 12 | 37 | |
22/1 | 13 | 38 | |
22/2 | 14 | 39 | |
22/3 | 15 | 40 | |
22/4 | 16 | 41 | |
23/1 | 17 | 42 | |
23/2 | 18 | 43 | |
23/3 | 19 | 44 | |
23/4 | 20 | 45 | |
24/1 | 21 | 46 | |
24/2 | 22 | 47 | |
24/3 | 23 | 48 | |
24/4 | 24 | 49 | |
25/1 | 1 | 26 | Connector P6/ |
25/2 | 2 | 27 | |
25/3 | 3 | 28 | |
25/4 | 4 | 29 | |
26/1 | 5 | 30 | |
26/2 | 6 | 31 | |
26/3 | 7 | 32 | |
26/4 | 8 | 33 | |
27/1 | 9 | 34 | |
27/2 | 10 | 35 | |
27/3 | 11 | 36 | |
27/4 | 12 | 37 | |
28/1 | 13 | 38 | |
28/2 | 14 | 39 | |
28/3 | 15 | 40 | |
28/4 | 16 | 41 | |
31/1 | 9 | 34 | Connector P2/ |
31/2 | 10 | 35 | |
31/3 | 11 | 36 | |
31/4 | 12 | 37 | |
32/1 | 13 | 38 | |
32/2 | 14 | 39 | |
32/3 | 15 | 40 | |
32/4 | 16 | 41 | |
33/1 | 17 | 42 | |
33/2 | 18 | 43 | |
33/3 | 19 | 44 | |
33/4 | 20 | 45 | |
34/1 | 21 | 46 | |
34/2 | 22 | 47 | |
34/3 | 23 | 48 | |
34/4 | 24 | 49 | |
35/1 | 1 | 26 | Connector P3/ |
35/2 | 2 | 27 | |
35/3 | 3 | 28 | |
35/4 | 4 | 29 | |
36/1 | 5 | 30 | |
36/2 | 6 | 31 | |
36/3 | 7 | 32 | |
36/4 | 8 | 33 | |
37/1 | 9 | 34 | |
37/2 | 10 | 35 | |
37/3 | 11 | 36 | |
37/4 | 12 | 37 | |
38/1 | 13 | 38 | |
38/2 | 14 | 39 | |
38/3 | 15 | 40 | |
38/4 | 16 | 41 | |
Table B-7 maps the MC ports and the wire pairs when using the five-to-six cables (see Table 3-8) for a Direct Connect without a PSC configuration. The corresponding cable kit number is CAB-MC-6:5-REPIN. You can use the five-to-six cables to connect the MC to the MDF for systems using dual-port DMT-2 ATU-C or quad-port xTU-C modules.
| MC Slot/Line | Champ Pins | Cable Connector | |
|---|---|---|---|
| Tip | Ring | ||
1/1 | 1 | 26 | P1 |
1/2 | 2 | 27 | |
1/3 | 3 | 28 | |
1/4 | 4 | 29 | |
2/1 | 5 | 30 | |
2/2 | 6 | 31 | |
2/3 | 7 | 32 | |
2/4 | 8 | 33 | |
3/1 | 9 | 34 | |
3/2 | 10 | 35 | |
3/3 | 11 | 36 | |
3/4 | 12 | 37 | |
4/1 | 13 | 38 | |
4/2 | 14 | 39 | |
4/3 | 15 | 40 | |
4/4 | 16 | 41 | |
5/1 | 17 | 42 | |
5/2 | 18 | 43 | |
5/3 | 19 | 44 | |
5/4 | 20 | 45 | |
6/1 | 21 | 46 | |
6/2 | 22 | 47 | |
6/3 | 23 | 48 | |
6/4 | 24 | 49 | |
7/1 | 1 | 26 | P2 |
7/2 | 2 | 27 | |
7/3 | 3 | 28 | |
7/4 | 4 | 29 | |
8/1 | 5 | 30 | |
8/2 | 6 | 31 | |
8/3 | 7 | 32 | |
8/4 | 8 | 33 | |
13/1 | 9 | 34 | |
13/2 | 10 | 35 | |
13/3 | 11 | 36 | |
13/4 | 12 | 37 | |
14/1 | 13 | 38 | |
14/2 | 14 | 39 | |
14/3 | 15 | 40 | |
14/4 | 16 | 41 | |
15/1 | 17 | 42 | |
15/2 | 18 | 43 | |
15/3 | 19 | 44 | |
15/4 | 20 | 45 | |
16/1 | 21 | 46 | |
16/2 | 22 | 47 | |
16/3 | 23 | 48 | |
16/4 | 24 | 49 | |
17/1 | 1 | 26 | P3 |
17/2 | 2 | 27 | |
17/3 | 3 | 28 | |
17/4 | 4 | 29 | |
18/1 | 5 | 30 | |
18/2 | 6 | 31 | |
18/3 | 7 | 32 | |
18/4 | 8 | 33 | |
19/1 | 9 | 34 | |
19/2 | 10 | 35 | |
19/3 | 11 | 36 | |
19/4 | 12 | 37 | |
21/1 | 13 | 38 | |
21/2 | 14 | 39 | |
21/3 | 15 | 40 | |
21/4 | 16 | 41 | |
22/1 | 17 | 42 | |
22/2 | 18 | 43 | |
22/3 | 19 | 44 | |
22/4 | 20 | 45 | |
23/1 | 21 | 46 | |
23/2 | 22 | 47 | |
23/3 | 23 | 48 | |
23/4 | 24 | 49 | |
24/1 | 1 | 26 | P4 |
24/2 | 2 | 27 | |
24/3 | 3 | 28 | |
24/4 | 4 | 29 | |
25/1 | 5 | 30 | |
25/2 | 6 | 31 | |
25/3 | 7 | 32 | |
25/4 | 8 | 33 | |
26/1 | 9 | 34 | |
26/2 | 10 | 35 | |
26/3 | 11 | 36 | |
26/4 | 12 | 37 | |
27/1 | 13 | 38 | |
27/2 | 14 | 39 | |
27/3 | 15 | 40 | |
27/4 | 16 | 41 | |
28/1 | 17 | 42 | |
28/2 | 18 | 43 | |
28/3 | 19 | 44 | |
28/4 | 20 | 45 | |
31/1 | 21 | 46 | |
31/2 | 22 | 47 | |
31/3 | 23 | 48 | |
31/4 | 24 | 49 | |
32/1 | 1 | 26 | P5 |
32/2 | 2 | 27 | |
32/3 | 3 | 28 | |
32/4 | 4 | 29 | |
33/1 | 5 | 30 | |
33/2 | 6 | 31 | |
33/3 | 7 | 32 | |
33/4 | 8 | 33 | |
34/1 | 9 | 34 | |
34/2 | 10 | 35 | |
34/3 | 11 | 36 | |
34/4 | 12 | 37 | |
35/1 | 13 | 38 | |
35/2 | 14 | 39 | |
35/3 | 15 | 40 | |
35/4 | 16 | 41 | |
36/1 | 17 | 42 | |
36/2 | 18 | 43 | |
36/3 | 19 | 44 | |
36/4 | 20 | 45 | |
37/1 | 21 | 46 | |
37/2 | 22 | 47 | |
37/3 | 23 | 48 | |
37/4 | 24 | 49 | |
Table B-8 maps the MC ports, the POTS splitter ports, and the wire pairs when using the one-to-one cables (see Table 3-9) when a Siecor POTS splitter is installed in your configuration. The corresponding cable kit number is CAB-6121-1.
| MC Slot/Line | POTS Splitter Slot/Line | Champ Pins | POTS Splitter Connection | |
|---|---|---|---|---|
| Tip | Ring | |||
1/1 | 1/1 | 26 | 1 | Line 1 to 24 or POTS 1 to 24 |
1/2 | 1/2 | 27 | 2 | |
1/3 | 1/3 | 28 | 3 | |
1/4 | 1/4 | 29 | 4 | |
2/1 | 1/5 | 30 | 5 | |
2/2 | 1/6 | 31 | 6 | |
2/3 | 1/7 | 32 | 7 | |
2/4 | 1/8 | 33 | 8 | |
3/1 | 2/1 | 34 | 9 | |
3/2 | 2/2 | 35 | 10 | |
3/3 | 2/3 | 36 | 11 | |
3/4 | 2/4 | 37 | 12 | |
4/1 | 2/5 | 38 | 13 | |
4/2 | 2/6 | 39 | 14 | |
4/3 | 2/7 | 40 | 15 | |
4/4 | 2/8 | 41 | 16 | |
5/1 | 3/1 | 42 | 17 | |
5/2 | 3/2 | 43 | 18 | |
5/3 | 3/3 | 44 | 19 | |
5/4 | 3/4 | 45 | 20 | |
6/1 | 3/5 | 46 | 21 | |
6/2 | 3/6 | 47 | 22 | |
6/3 | 3/7 | 48 | 23 | |
6/4 | 3/8 | 49 | 24 | |
7/1 | 4/1 | 26 | 1 | Line 25 to 48 or POTS 25 to 48 |
7/2 | 4/2 | 27 | 2 | |
7/3 | 4/3 | 28 | 3 | |
7/4 | 4/4 | 29 | 4 | |
8/1 | 4/5 | 30 | 5 | |
8/2 | 4/6 | 31 | 6 | |
8/3 | 4/7 | 32 | 7 | |
8/4 | 4/8 | 33 | 8 | |
13/1 | 5/1 | 34 | 9 | |
13/2 | 5/2 | 35 | 10 | |
13/3 | 5/3 | 36 | 11 | |
13/4 | 5/4 | 37 | 12 | |
14/1 | 5/5 | 38 | 13 | |
14/2 | 5/6 | 39 | 14 | |
14/3 | 5/7 | 40 | 15 | |
14/4 | 5/8 | 41 | 16 | |
15/1 | 6/1 | 42 | 17 | |
15/2 | 6/2 | 43 | 18 | |
15/3 | 6/3 | 44 | 19 | |
15/4 | 6/4 | 45 | 20 | |
16/1 | 6/5 | 46 | 21 | |
16/2 | 6/6 | 47 | 22 | |
16/3 | 6/7 | 48 | 23 | |
16/4 | 6/8 | 49 | 24 | |
17/1 | 7/1 | 26 | 1 | Line 49 to 72 or POTS 49 to 72 |
17/2 | 7/2 | 27 | 2 | |
17/3 | 7/3 | 28 | 3 | |
17/4 | 7/4 | 29 | 4 | |
18/1 | 7/5 | 30 | 5 | |
18/2 | 7/6 | 31 | 6 | |
18/3 | 7/7 | 32 | 7 | |
18/4 | 7/8 | 33 | 8 | |
19/1 | 8/1 | 34 | 9 | |
19/2 | 8/2 | 35 | 10 | |
19/3 | 8/3 | 36 | 11 | |
19/4 | 8/4 | 37 | 12 | |
20/1 | 8/5 | 38 | 13 | |
20/2 | 8/6 | 39 | 14 | |
20/3 | 8/7 | 40 | 15 | |
20/4 | 8/8 | 41 | 16 | |
21/1 | 9/1 | 42 | 17 | |
21/2 | 9/2 | 43 | 18 | |
21/3 | 9/3 | 44 | 19 | |
21/4 | 9/4 | 45 | 20 | |
22/1 | 9/5 | 46 | 21 | |
22/2 | 9/6 | 47 | 22 | |
22/3 | 9/7 | 48 | 23 | |
22/4 | 9/8 | 49 | 24 | |
23/1 | 10/1 | 26 | 1 | Line 73 to 96 or POTS 73 to 96 |
23/2 | 10/2 | 27 | 2 | |
23/3 | 10/3 | 28 | 3 | |
23/4 | 10/4 | 29 | 4 | |
24/1 | 10/5 | 30 | 5 | |
24/2 | 10/6 | 31 | 6 | |
24/3 | 10/7 | 32 | 7 | |
24/4 | 10/8 | 33 | 8 | |
25/1 | 11/1 | 34 | 9 | |
25/2 | 11/2 | 35 | 10 | |
25/3 | 11/3 | 36 | 11 | |
25/4 | 11/4 | 37 | 12 | |
26/1 | 11/5 | 38 | 13 | |
26/2 | 11/6 | 39 | 14 | |
26/3 | 11/7 | 40 | 15 | |
26/4 | 11/8 | 41 | 16 | |
27/1 | 12/1 | 42 | 17 | |
27/2 | 12/2 | 43 | 18 | |
27/3 | 12/3 | 44 | 19 | |
27/4 | 12/4 | 45 | 20 | |
28/1 | 12/5 | 46 | 21 | |
28/2 | 12/6 | 47 | 22 | |
28/3 | 12/7 | 48 | 23 | |
28/4 | 12/8 | 49 | 24 | |
31/1 | 13/1 | 26 | 1 | Line 97 to 120 or POTS 97 to 120 |
31/2 | 13/2 | 27 | 2 | |
31/3 | 13/3 | 28 | 3 | |
31/4 | 13/4 | 29 | 4 | |
32/1 | 13/5 | 30 | 5 | |
32/2 | 13/6 | 31 | 6 | |
32/3 | 13/7 | 32 | 7 | |
32/4 | 13/8 | 33 | 8 | |
33/1 | 14/1 | 34 | 9 | |
33/2 | 14/2 | 35 | 10 | |
33/3 | 14/3 | 36 | 11 | |
33/4 | 14/4 | 37 | 12 | |
34/1 | 14/5 | 38 | 13 | |
34/2 | 14/6 | 39 | 14 | |
34/3 | 14/7 | 40 | 15 | |
34/4 | 14/8 | 41 | 16 | |
35/1 | 15/1 | 42 | 17 | |
35/2 | 15/2 | 43 | 18 | |
35/3 | 15/3 | 44 | 19 | |
35/4 | 15/4 | 45 | 20 | |
36/1 | 15/5 | 46 | 21 | |
36/2 | 15/6 | 47 | 22 | |
36/3 | 15/7 | 48 | 23 | |
36/4 | 15/8 | 49 | 24 | |
37/1 | 16/1 | 26 | 1 | Line 121 to 128 or POTS 121 to 128 |
37/2 | 16/2 | 27 | 2 | |
37/3 | 16/3 | 28 | 3 | |
37/4 | 16/4 | 29 | 4 | |
38/1 | 16/5 | 30 | 5 | |
38/2 | 16/6 | 31 | 6 | |
38/3 | 16/7 | 32 | 7 | |
38/4 | 16/8 | 33 | 8 | |
Table B-9 provides the Champ pins and MC port mapping information needed to build your own MC cables.
| Connector | Champ Pins | MC Slot/Line | |
|---|---|---|---|
| Tip | Ring | ||
J39 xDSL Slots 3 through 8 (pins 25 and 50 are not used) | 1 | 2 | 6/1 |
3 | 4 | 6/2 | |
5 | 6 | 6/3 | |
7 | 8 | 6/4 | |
9 | 10 | 7/1 | |
11 | 12 | 7/2 | |
13 | 14 | 7/3 | |
15 | 16 | 7/4 | |
17 | 18 | 8/1 | |
19 | 20 | 8/2 | |
21 | 22 | 8/3 | |
23 | 24 | 8/4 | |
26 | 27 | 5/1 | |
28 | 29 | 5/2 | |
30 | 31 | 5/3 | |
32 | 33 | 5/4 | |
34 | 35 | 4/1 | |
36 | 37 | 4/2 | |
38 | 39 | 4/3 | |
40 | 41 | 4/4 | |
42 | 43 | 3/1 | |
44 | 45 | 3/2 | |
46 | 47 | 3/3 | |
48 | 49 | 3/4 | |
J40 xDSL Slots 1, 2, 21, and 22 (pins 9 through 25 are not used) | 1 | 2 | 22/1 |
3 | 4 | 22/2 | |
5 | 6 | 22/3 | |
7 | 8 | 22/4 | |
26 | 27 | 21/1 | |
28 | 29 | 21/2 | |
30 | 31 | 21/3 | |
32 | 33 | 21/4 | |
34 | 35 | 2/1 | |
36 | 37 | 2/2 | |
38 | 39 | 2/3 | |
40 | 41 | 2/4 | |
42 | 43 | 1/1 | |
44 | 45 | 1/2 | |
46 | 47 | 1/3 | |
48 | 49 | 1/4 | |
J41 xDSL Slots 23 through 23 (pins 25 and 50 are not used) | 1 | 2 | 26/1 |
3 | 4 | 26/2 | |
5 | 6 | 26/3 | |
7 | 8 | 26/4 | |
9 | 10 | 27/1 | |
11 | 12 | 27/2 | |
13 | 14 | 27/3 | |
15 | 16 | 27/4 | |
17 | 18 | 28/1 | |
19 | 20 | 28/2 | |
21 | 22 | 28/3 | |
23 | 24 | 28/4 | |
26 | 27 | 25/1 | |
28 | 29 | 25/2 | |
30 | 31 | 25/3 | |
32 | 33 | 25/4 | |
34 | 35 | 24/1 | |
36 | 37 | 24/2 | |
38 | 39 | 24/3 | |
40 | 41 | 24/4 | |
42 | 43 | 23/1 | |
44 | 45 | 23/2 | |
46 | 47 | 23/3 | |
48 | 49 | 23/4 | |
J42 xDSL Slots 13 through 18 (pins 25 and 50 are not used) | 1 | 2 | 17/1 |
3 | 4 | 17/2 | |
5 | 6 | 17/3 | |
7 | 8 | 17/4 | |
9 | 10 | 18/1 | |
11 | 12 | 18/2 | |
13 | 14 | 18/3 | |
15 | 16 | 18/4 | |
17 | 18 | 13/1 | |
19 | 20 | 13/2 | |
21 | 22 | 13/3 | |
23 | 24 | 13/4 | |
26 | 27 | 16/1 | |
28 | 29 | 16/2 | |
30 | 31 | 16/3 | |
32 | 33 | 16/4 | |
34 | 35 | 15/1 | |
36 | 37 | 15/2 | |
38 | 39 | 15/3 | |
40 | 41 | 15/4 | |
42 | 43 | 14/1 | |
44 | 45 | 14/2 | |
46 | 47 | 14/3 | |
48 | 49 | 14/4 | |
J43 xDSL Slots 19, 20, 37, and 38 (pins 9 through 25 and 50 are not used) | 1 | 2 | 20/1 |
3 | 4 | 20/2 | |
5 | 6 | 20/3 | |
7 | 8 | 20/4 | |
26 | 27 | 19/1 | |
28 | 29 | 19/2 | |
30 | 31 | 19/3 | |
32 | 33 | 19/4 | |
34 | 35 | 38/1 | |
36 | 37 | 38/2 | |
38 | 39 | 38/3 | |
40 | 41 | 38/4 | |
42 | 43 | 37/1 | |
44 | 45 | 37/2 | |
46 | 47 | 37/3 | |
48 | 49 | 37/4 | |
J44 xDSL Slots 31 through 36 (pins 25 and 50 are not used) | 1 | 2 | 35/1 |
3 | 4 | 35/2 | |
5 | 6 | 35/3 | |
7 | 8 | 35/4 | |
9 | 10 | 36/1 | |
11 | 12 | 36/2 | |
13 | 14 | 36/3 | |
15 | 16 | 36/4 | |
17 | 18 | 31/1 | |
19 | 20 | 31/2 | |
21 | 22 | 31/3 | |
23 | 24 | 31/4 | |
26 | 27 | 34/1 | |
28 | 29 | 34/2 | |
30 | 31 | 34/3 | |
32 | 33 | 34/4 | |
34 | 35 | 33/1 | |
36 | 37 | 33/2 | |
38 | 39 | 33/3 | |
40 | 41 | 33/4 | |
42 | 43 | 32/1 | |
44 | 45 | 32/2 | |
46 | 47 | 32/3 | |
48 | 49 | 32/4 | |
In designing the cables for the Cisco 6100 Series connections, Cisco used a standard telco color chart. Table B-10 lists the colors used for the Cisco 6100 Series cables.
| Wire Color | P1 | Wire Color | P2 | Wire Color | P1 | Wire Color | P2 | |
|---|---|---|---|---|---|---|---|---|
Wht/blu | 1 | Wht/blu | 1 |
| Grn/blk | 38 | Grn/blk | 38 |
Blu/wht | 26 | Blu/wht | 26 |
| Blk/brn | 14 | Blk/brn | 14 |
Wht/org | 2 | Wht/org | 2 |
| Brn/blk | 39 | Brn/blk | 39 |
Org/wht | 27 | Org/wht | 27 |
| Blk/gry | 15 | Blk/gry | 15 |
Wht/grn | 3 | Wht/grn | 3 |
| Gry/blk | 40 | Gry/blk | 40 |
Grn/wht | 28 | Grn/wht | 28 |
| Yel/blu | 16 | Yel/blu | 16 |
Wht/brn | 4 | Wht/brn | 4 |
| Blu/yel | 41 | Blu/yel | 41 |
Brn/wht | 29 | Brn/wht | 29 |
| Yel/org | 17 | Yel/org | 17 |
Wht/gry | 5 | Wht/gry | 5 |
| Org/yel | 42 | Org/yel | 42 |
Gry/wht | 30 | Gry/wht | 30 |
| Yel/grn | 18 | Yel/grn | 18 |
Red/blu | 6 | Red/blu | 6 |
| Grn/yel | 43 | Grn/yel | 43 |
Blu/red | 31 | Blu/red | 31 |
| Yel/brn | 19 | Yel/brn | 19 |
Red/org | 7 | Red/org | 7 |
| Brn/yel | 44 | Brn/yel | 44 |
Org/red | 32 | Org/red | 32 |
| Yel/gry | 20 | Yel/gry | 20 |
Red/grn | 8 | Red/grn | 8 |
| Gry/yel | 45 | Gry/yel | 45 |
Grn/red | 33 | Grn/red | 33 |
| Vio/blu | 21 | Vio/blu | 21 |
Red/brn | 9 | Red/brn | 9 |
| Blu/vio | 46 | Blu/vio | 46 |
Brn/red | 34 | Brn/red | 34 |
| Vio/org | 22 | Vio/org | 22 |
Red/gry | 10 | Red/gry | 10 |
| Org/vio | 47 | Org/vio | 47 |
Gry/red | 35 | Gry/red | 35 |
| Vio/grn | 23 | Vio/grn | 23 |
Blk/blu | 11 | Blk/blu | 11 |
| Grn/vio | 48 | Grn/vio | 48 |
Blu/blk | 36 | Blu/blk | 36 |
| Vio/brn | 24 | Vio/brn | 24 |
Blk/org | 12 | Blk/org | 12 |
| Brn/vio | 49 | Brn/vio | 49 |
Org/blk | 37 | Org/blk | 37 |
| Vio/gry | 25 | Vio/gry | 25 |
Blk/grn | 13 | Blk/grn | 13 |
| Gry/vio | 50 | Gry/vio | 50 |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Tue Nov 16 15:03:37 PST 1999
Copyright 1989-1999©Cisco Systems Inc.