Connectors, Pinouts, and Port Mapping

Connectors, Pinouts, and Port Mapping

This appendix provides connectors, pinouts, and port mapping tables for a Direct Connect configuration of the Cisco 6100 Series system.

For a list of Direct Connect configuration cables and their respective Cisco part numbers, see "Cabling for a Direct Connect Configuration."

B.1 Multiplexer Chassis Connectors

This section describes multiplexer chassis (MC) connectors and pinouts for the following:

B.1.1 xDSL Connectors

The backplane of the MC contains six Champ connectors which connect to the xTU-C twisted-pair subscriber data interface. This connection can be made by either of the following:


Note For more information on the PSC Champ connector, see the
"Connect the MC to the PSC" section.

Figure B-1 shows connector pin locations for the xDSL Champ connectors. Pin locations are the same for all Champ connectors.


Figure B-1:
xDSL Connector Pin Locations



Note To achieve Network Equipment Building Systems (NEBS) compliance, you must screw all cables into the backplane and tie wrap Champ connectors (see
"NEBS Compliance Cabling Guidelines" section).

B.1.2 Terminal Block Connector

Use the terminal block connector to wire the MC to the power source on the fuse and alarm panel. For more information on fusing, see one of the following:

The terminal block connectors will accept 14 to 18 American Wire Gauge (AWG) copper solid or stranded wire. Figure B-2 shows the Cisco 6100 Series power terminal block.


Figure B-2: Power Terminal Block



Note See
"Planning for a Cisco 6100 Series System" for calculation tables necessary to determine the fuse amperage for each component that is wired to the fuse and alarm panel. Also, the calculation tables in this appendix will help you determine if the watts in your rack exceed the acceptable levels. If the watts exceed the acceptable levels, you will need to either replan your configuration or use more than one rack to house the Cisco 6100 Series system components.

B.1.3 Alarm Contacts

The Cisco 6100 Series system provides alarm contacts for audible, visual, and E2A alarm connections. These contacts support minor, major, and critical alarm reporting. (Figure B-3 shows the alarm contacts.)


Figure B-3: Alarm Contacts


Table B-1 lists the alarm contact pinouts shown in Figure B-3.


Table B-1: Alarm Contact Pinouts
Connector Pin Signal

E2A

P14

1

Critical_E2+

2

Critical_E2-

3

Major_E2+

4

Major_E2-

5

Minor_E2+

6

Minor_E2-

7

Fan Alarm+

8

Fan Alarm-

Visual

P15

1

Critical_V+

2

Critical_V-

3

Major_V+

4

Major_V-

5

Minor_V+

6

Minor_V-

7

ACO_IN_V (future)

8

ACO_RTN_V (future)

Audible

P17

1

Critical_A+

2

Critical_A-

3

Major_A+

4

Major_A-

5

Minor_A+

6

Minor_A-

7

ACO_IN_A

8

ACO_RTN_A

For more information on the alarm contacts, see one of the following:

B.2 Port Mapping Tables

This section provides port mapping tables which show the wire pair and chassis port assignments for the following:

B.2.1 Direct Connect with PSC Configuration Port Mapping Tables

Table B-2 maps the MC ports, the PSC ports, and the wire pairs when using the one-to-one cables (see Table 3-2) for a Direct Connect with a PSC configuration. The corresponding cable kit number is CAB-61-014.


Table B-2: Port Mapping for One-to-One Cables in a Direct Connect with PSC Configuration
MC Slot/Line PSC Slot/Line Champ Pins PSC MDF1/POTS Connection
Tip Ring

1/1

1/1

9

34

J11/J7

1/2

1/2

10

35

2/1

1/3

11

36

2/2

1/4

12

37

3/1

2/1

5

30

3/2

2/2

6

31

4/1

2/3

7

32

4/2

2/4

8

33

5/1

3/1

1

26

5/2

3/2

2

27

6/1

3/3

3

28

6/2

3/4

4

29

7/1

4/1

18

43

7/2

4/2

19

44

8/1

4/3

20

45

8/2

4/4

21

46

13/1

19/1

18

43

J14/J8

13/2

19/2

19

44

14/1

19/3

20

45

14/2

19/4

21

46

15/1

20/1

1

26

15/2

20/2

2

27

16/1

20/3

3

28

16/2

20/4

4

29

17/1

21/1

5

30

17/2

21/2

6

31

18/1

21/3

7

32

18/2

21/4

8

33

19/1

22/1

9

34

19/2

22/2

10

35

20/1

22/3

11

36

20/2

22/4

12

37

21/1

5/1

22

47

J11/J7

21/2

5/2

23

48

22/1

5/3

24

49

22/2

5/4

25

50

23/1

6/1

6

31

J12/J9

23/2

6/2

7

32

24/1

6/3

8

33

24/2

6/4

9

34

25/1

7/1

2

27

25/2

7/2

3

28

26/1

7/3

4

29

26/2

7/4

5

30

27/1

8/1

1

26

27/2

8/2

10

35

28/1

8/3

11

36

28/2

8/4

12

37

31/1

15/1

1

26

J13/J10

31/2

15/2

10

35

32/1

15/3

11

36

32/2

15/4

12

37

33/1

16/1

2

27

33/2

16/2

3

28

34/1

16/3

4

29

34/2

16/4

5

30

35/1

17/1

6

31

35/2

17/2

7

32

36/1

17/3

8

33

36/2

17/4

9

34

37/1

18/1

22

47

J14/J8

37/2

18/2

23

48

38/1

18/3

24

49

38/2

18/4

25

50

1MDF = main distribution frame

Table B-3 maps the MC ports, the PSC ports for two PSCs, and the wire pairs when using the two-to-one cables (see Table 3-3) for a Direct Connect with a PSC configuration. The corresponding cable kit number is CAB-MC128-PSC80. You can use the two-to-one cables to connect one MC to two PSCs for systems using quad-port ATU-C modules.


Table B-3: Port Mapping for Two-to-One Cables in a Direct Connect with PSC Configuration
MC Slot/Line PSC Slot/Line Champ Pins PSC MDF/
POTS Connection
PSC 1 PSC 2 Tip Ring

1/1

1/1

---

9

34

J11/J7

1/2

1/2

---

10

35

1/3

---

1/1

9

34

1/4

---

1/2

10

35

2/1

1/3

---

11

36

2/2

1/4

---

12

37

2/3

---

1/3

11

36

2/4

---

1/4

12

37

3/1

2/1

---

5

30

3/2

2/2

---

6

31

3/3

---

2/1

5

30

3/4

---

2/2

6

31

4/1

2/3

---

7

32

4/2

2/4

---

8

33

4/3

---

2/3

7

32

4/4

---

2/4

8

33

5/1

3/1

---

1

26

5/2

3/2

---

2

27

5/3

---

3/1

1

26

5/4

---

3/2

2

27

6/1

3/3

---

3

28

6/2

3/4

---

4

29

6/3

---

3/3

3

28

6/4

---

3/4

4

29

7/1

4/1

---

18

43

7/2

4/2

---

19

44

7/3

---

4/1

18

43

7/4

---

4/2

19

44

8/1

4/3

---

20

45

8/2

4/4

---

21

46

8/3

---

4/3

20

45

8/4

---

4/4

21

46

13/1

19/1

---

18

43

J14/J8

13/2

19/2

---

19

44

13/3

---

19/1

18

43

13/4

---

19/2

19

44

14/1

19/3

---

20

45

14/2

19/4

---

21

46

14/3

---

19/3

20

45

14/4

---

19/4

21

46

15/1

20/1

---

1

26

15/2

20/2

---

2

27

15/3

---

20/1

1

26

15/4

---

20/2

2

27

16/1

20/3

---

3

28

16/2

20/4

---

4

29

16/3

---

20/3

3

28

16/4

---

20/4

4

29

17/1

21/1

---

5

30

17/2

21/2

---

6

31

17/3

---

21/1

5

30

17/4

---

21/2

6

31

18/1

21/3

---

7

32

18/2

21/4

---

8

33

18/3

---

21/3

7

32

18/4

---

21/4

8

33

19/1

22/1

---

9

34

19/2

22/2

---

10

35

19/3

---

22/1

9

34

19/4

---

22/2

10

35

20/1

22/3

---

11

36

20/2

22/4

---

12

37

20/3

---

22/3

11

36

20/4

---

22/4

12

37

21/1

5/1

---

22

47

J11/J7

21/2

5/2

---

23

48

21/3

---

5/1

22

47

21/4

---

5/2

23

48

22/1

5/3

---

24

49

22/2

5/4

---

25

50

22/3

---

5/3

24

49

22/4

---

5/4

25

50

23/1

6/1

---

6

31

J12/J9

23/2

6/2

---

7

32

23/3

---

6/1

6

31

23/4

---

6/2

7

32

24/1

6/3

---

8

33

24/2

6/4

---

9

34

24/3

---

6/3

8

33

24/4

---

6/4

9

34

25/1

7/1

---

2

27

25/2

7/2

---

3

28

25/3

---

7/1

2

27

25/4

---

7/2

3

28

26/1

7/3

---

4

29

26/2

7/4

---

5

30

26/3

---

7/3

4

29

26/4

---

7/4

5

30

27/1

8/1

---

1

26

27/2

8/2

---

10

35

27/3

---

8/1

1

26

27/4

---

8/2

10

35

28/1

8/3

---

11

36

28/2

8/4

---

12

37

28/3

---

8/3

11

36

28/4

---

8/4

12

37

31/1

15/1

---

1

26

J13/J10

31/2

15/2

---

10

35

31/3

---

15/1

1

26

31/4

---

15/2

10

35

32/1

15/3

---

11

36

32/2

15/4

---

12

37

32/3

---

15/3

11

36

32/4

---

15/4

12

37

33/1

16/1

---

2

27

33/2

16/2

---

3

28

33/3

---

16/1

2

27

33/4

---

16/2

3

28

34/1

16/3

---

4

29

34/2

16/4

---

5

30

34/3

---

16/3

4

29

34/4

---

16/4

5

30

35/1

17/1

---

6

31

35/2

17/2

---

7

32

35/3

---

17/1

6

31

35/4

---

17/2

7

32

36/1

17/3

---

8

33

36/2

17/4

---

9

34

36/3

---

17/3

8

33

36/4

---

17/4

9

34

37/1

18/1

---

22

47

J14/J8

37/2

18/2

---

23

48

37/3

---

18/1

22

47

37/4

---

18/2

23

48

38/1

18/3

---

24

49

38/2

18/4

---

25

50

38/3

---

18/3

24

49

38/4

---

18/4

25

50

Table B-4 maps the MC ports, the PSC ports, and the wire pairs when using the two-to-two cables (see Table 3-5) for a Direct Connect with a PSC configuration. The corresponding cable kit number is CAB-PSC-80-REPIN.

You can use the two-to-two cables to clearly associate the mapping between the wire pairs and the MC/PSC ports. These cables attach to the PSC MDF connections (J11 to J14) and the PSC POTS connections (J7 to J10) for systems using dual-port xTU-C modules.


Table B-4: Port Mapping for Two-to-Two Cables in a Direct Connect with PSC Configuration
MC Slot/Line PSC Slot/Line Champ Pins Cable Connector
Tip Ring

1/1

1/1

1

26

P1

1/2

1/2

2

27

2/1

1/3

3

28

2/2

1/4

4

29

3/1

2/1

5

30

3/2

2/2

6

31

4/1

2/3

7

32

4/2

2/4

8

33

5/1

3/1

9

34

5/2

3/2

10

35

6/1

3/3

11

36

6/2

3/4

12

37

7/1

4/1

13

38

7/2

4/2

14

39

8/1

4/3

15

40

8/2

4/4

16

41

13/1

19/1

1

26

P2

13/2

19/2

2

27

14/1

19/3

3

28

14/2

19/4

4

29

15/1

20/1

5

30

15/2

20/2

6

31

16/1

20/3

7

32

16/2

20/4

8

33

17/1

21/1

9

34

17/2

21/2

10

35

18/1

21/3

11

36

18/2

21/4

12

37

19/1

22/1

13

38

19/2

22/2

14

39

20/1

22/3

15

40

20/2

22/4

16

41

21/1

5/1

1

26

P3

21/2

5/2

2

27

22/1

5/3

3

28

22/2

5/4

4

29

23/1

6/1

5

30

23/2

6/2

6

31

24/1

6/3

7

32

24/2

6/4

8

33

25/1

7/1

9

34

25/2

7/2

10

35

26/1

7/3

11

36

26/2

7/4

12

37

27/1

8/1

13

38

27/2

8/2

14

39

28/1

8/3

15

40

28/2

8/4

16

41

31/1

15/1

1

26

P4

31/2

15/2

2

27

32/1

15/3

3

28

32/2

15/4

4

29

33/1

16/1

5

30

33/2

16/2

6

31

34/1

16/3

7

32

34/2

16/4

8

33

35/1

17/1

9

34

35/2

17/2

10

35

36/1

17/3

11

36

36/2

17/4

12

37

37/1

18/1

13

38

37/2

18/2

14

39

38/1

18/3

15

40

38/2

18/4

16

41

B.2.2 Direct Connect without PSC Configuration Port Mapping Tables

Table B-5 maps the MC ports and the wire pairs when using the two-to-three cables (see Table 3-6) for a Direct Connect without a PSC configuration. The corresponding cable kit number is CAB-MC-3:2-REPIN. You can use the two-to-three cables to connect the MC to the MDF for systems using dual-port DMT-2 ATU-C modules.


Note This cable is not recommended if you plan on expanding your system to quad-port xTU-C modules, which will be available in future releases.


Table B-5: Port Mapping for Two-to-Three Cables in a Direct Connect without PSC Configuration
MC Slot/Line Champ Pins Cable Connector/
Cable Part Number
Tip Ring

1/1

1

26

Connector P2/
Cable 72-1590-02

1/2

2

27

2/1

3

28

2/2

4

29

3/1

5

30

3/2

6

31

4/1

7

32

4/2

8

33

5/1

9

34

5/2

10

35

6/1

11

36

6/2

12

37

7/1

13

38

7/2

14

39

8/1

15

40

8/2

16

41

13/1

1

26

Connector P2/
Cable 72-1591-02

13/2

2

27

14/1

3

28

14/2

4

29

15/1

5

30

15/2

6

31

16/1

7

32

16/2

8

33

17/1

9

34

17/2

10

35

18/1

11

36

18/2

12

37

19/1

13

38

19/2

14

39

20/1

15

40

20/2

16

41

21/1

1

26

Connector P1/
Cable 72-1590-02

21/2

2

27

22/1

3

28

22/2

4

29

23/1

5

30

23/2

6

31

24/1

7

32

24/2

8

33

25/1

9

34

25/2

10

35

26/1

11

36

26/2

12

37

27/1

13

38

27/2

14

39

28/1

15

40

28/2

16

41

31/1

1

26

Connector P1/
Cable 72-1591-02

31/2

2

27

32/1

3

28

32/2

4

29

33/1

5

30

33/2

6

31

34/1

7

32

34/2

8

33

35/1

9

34

35/2

10

35

36/1

11

36

36/2

12

37

37/1

13

38

37/2

14

39

38/1

15

40

38/2

16

41

Table B-6 maps the MC ports and the wire pairs when using the three-to-three cables (see Table 3-7) for a Direct Connect without a PSC configuration. The corresponding cable kit number is CAB-MC128-MDF. You can use the three-to-three cables to connect the MC to the MDF for systems using dual-port DMT-2 ATU-C or quad-port xTU-C modules.


Table B-6: Port Mapping for Three-to-Three Cables in a Direct Connect without PSC Configuration
MC Slot/Line Champ Pins Cable Connector/
Cable Part Number
Tip Ring

1/1

1

26

Connector P4/
Cable 72-1765-01

1/2

2

27

1/3

3

28

1/4

4

29

2/1

5

30

2/2

6

31

2/3

7

32

2/4

8

33

3/1

9

34

3/2

10

35

3/3

11

36

3/4

12

37

4/1

13

38

4/2

14

39

4/3

15

40

4/4

16

41

5/1

17

42

5/2

18

43

5/3

19

44

5/4

20

45

6/1

21

46

6/2

22

47

6/3

23

48

6/4

24

49

7/1

1

26

Connector P5/
Cable 72-1765-01

7/2

2

27

7/3

3

28

7/4

4

29

8/1

5

30

8/2

6

31

8/3

7

32

8/4

8

33

13/1

1

26

Connector P1/
Cable 72-1720-01

13/2

2

27

13/3

3

28

13/4

4

29

14/1

5

30

14/2

6

31

14/3

7

32

14/4

8

33

15/1

9

34

15/2

10

35

15/3

11

36

15/4

12

37

16/1

13

38

16/2

14

39

16/3

15

40

16/4

16

41

17/1

17

42

17/2

18

43

17/3

19

44

17/4

20

45

18/1

21

46

18/2

22

47

18/3

23

48

18/4

24

49

19/1

1

26

Connector P2/
Cable 72-1720-01

19/2

2

27

19/3

3

28

19/4

4

29

20/1

5

30

20/2

6

31

20/3

7

32

20/4

8

33

21/1

9

34

Connector P5/
Cable 72-1765-01

21/2

10

35

21/3

11

36

21/4

12

37

22/1

13

38

22/2

14

39

22/3

15

40

22/4

16

41

23/1

17

42

23/2

18

43

23/3

19

44

23/4

20

45

24/1

21

46

24/2

22

47

24/3

23

48

24/4

24

49

25/1

1

26

Connector P6/
Cable 72-1765-01

25/2

2

27

25/3

3

28

25/4

4

29

26/1

5

30

26/2

6

31

26/3

7

32

26/4

8

33

27/1

9

34

27/2

10

35

27/3

11

36

27/4

12

37

28/1

13

38

28/2

14

39

28/3

15

40

28/4

16

41

31/1

9

34

Connector P2/
Cable 72-1720-01

31/2

10

35

31/3

11

36

31/4

12

37

32/1

13

38

32/2

14

39

32/3

15

40

32/4

16

41

33/1

17

42

33/2

18

43

33/3

19

44

33/4

20

45

34/1

21

46

34/2

22

47

34/3

23

48

34/4

24

49

35/1

1

26

Connector P3/
Cable 72-1720-01

35/2

2

27

35/3

3

28

35/4

4

29

36/1

5

30

36/2

6

31

36/3

7

32

36/4

8

33

37/1

9

34

37/2

10

35

37/3

11

36

37/4

12

37

38/1

13

38

38/2

14

39

38/3

15

40

38/4

16

41

Table B-7 maps the MC ports and the wire pairs when using the five-to-six cables (see Table 3-8) for a Direct Connect without a PSC configuration. The corresponding cable kit number is CAB-MC-6:5-REPIN. You can use the five-to-six cables to connect the MC to the MDF for systems using dual-port DMT-2 ATU-C or quad-port xTU-C modules.


Table B-7: Port Mapping for Five-to-Six Cables in a Direct Connect without PSC Configuration
MC Slot/Line Champ Pins Cable Connector
Tip Ring

1/1

1

26

P1

1/2

2

27

1/3

3

28

1/4

4

29

2/1

5

30

2/2

6

31

2/3

7

32

2/4

8

33

3/1

9

34

3/2

10

35

3/3

11

36

3/4

12

37

4/1

13

38

4/2

14

39

4/3

15

40

4/4

16

41

5/1

17

42

5/2

18

43

5/3

19

44

5/4

20

45

6/1

21

46

6/2

22

47

6/3

23

48

6/4

24

49

7/1

1

26

P2

7/2

2

27

7/3

3

28

7/4

4

29

8/1

5

30

8/2

6

31

8/3

7

32

8/4

8

33

13/1

9

34

13/2

10

35

13/3

11

36

13/4

12

37

14/1

13

38

14/2

14

39

14/3

15

40

14/4

16

41

15/1

17

42

15/2

18

43

15/3

19

44

15/4

20

45

16/1

21

46

16/2

22

47

16/3

23

48

16/4

24

49

17/1

1

26

P3

17/2

2

27

17/3

3

28

17/4

4

29

18/1

5

30

18/2

6

31

18/3

7

32

18/4

8

33

19/1

9

34

19/2

10

35

19/3

11

36

19/4

12

37

21/1

13

38

21/2

14

39

21/3

15

40

21/4

16

41

22/1

17

42

22/2

18

43

22/3

19

44

22/4

20

45

23/1

21

46

23/2

22

47

23/3

23

48

23/4

24

49

24/1

1

26

P4

24/2

2

27

24/3

3

28

24/4

4

29

25/1

5

30

25/2

6

31

25/3

7

32

25/4

8

33

26/1

9

34

26/2

10

35

26/3

11

36

26/4

12

37

27/1

13

38

27/2

14

39

27/3

15

40

27/4

16

41

28/1

17

42

28/2

18

43

28/3

19

44

28/4

20

45

31/1

21

46

31/2

22

47

31/3

23

48

31/4

24

49

32/1

1

26

P5

32/2

2

27

32/3

3

28

32/4

4

29

33/1

5

30

33/2

6

31

33/3

7

32

33/4

8

33

34/1

9

34

34/2

10

35

34/3

11

36

34/4

12

37

35/1

13

38

35/2

14

39

35/3

15

40

35/4

16

41

36/1

17

42

36/2

18

43

36/3

19

44

36/4

20

45

37/1

21

46

37/2

22

47

37/3

23

48

37/4

24

49

B.2.3 Siecor POTS Splitter Port Mapping Table

Table B-8 maps the MC ports, the POTS splitter ports, and the wire pairs when using the one-to-one cables (see Table 3-9) when a Siecor POTS splitter is installed in your configuration. The corresponding cable kit number is CAB-6121-1.


Table B-8: Port Mapping for One-to-One Cables with a Siecor POTS Splitter
MC Slot/Line POTS Splitter Slot/Line Champ Pins POTS Splitter Connection
Tip Ring

1/1

1/1

26

1

Line 1 to 24 or POTS 1 to 24

1/2

1/2

27

2

1/3

1/3

28

3

1/4

1/4

29

4

2/1

1/5

30

5

2/2

1/6

31

6

2/3

1/7

32

7

2/4

1/8

33

8

3/1

2/1

34

9

3/2

2/2

35

10

3/3

2/3

36

11

3/4

2/4

37

12

4/1

2/5

38

13

4/2

2/6

39

14

4/3

2/7

40

15

4/4

2/8

41

16

5/1

3/1

42

17

5/2

3/2

43

18

5/3

3/3

44

19

5/4

3/4

45

20

6/1

3/5

46

21

6/2

3/6

47

22

6/3

3/7

48

23

6/4

3/8

49

24

7/1

4/1

26

1

Line 25 to 48 or POTS 25 to 48

7/2

4/2

27

2

7/3

4/3

28

3

7/4

4/4

29

4

8/1

4/5

30

5

8/2

4/6

31

6

8/3

4/7

32

7

8/4

4/8

33

8

13/1

5/1

34

9

13/2

5/2

35

10

13/3

5/3

36

11

13/4

5/4

37

12

14/1

5/5

38

13

14/2

5/6

39

14

14/3

5/7

40

15

14/4

5/8

41

16

15/1

6/1

42

17

15/2

6/2

43

18

15/3

6/3

44

19

15/4

6/4

45

20

16/1

6/5

46

21

16/2

6/6

47

22

16/3

6/7

48

23

16/4

6/8

49

24

17/1

7/1

26

1

Line 49 to 72 or POTS 49 to 72

17/2

7/2

27

2

17/3

7/3

28

3

17/4

7/4

29

4

18/1

7/5

30

5

18/2

7/6

31

6

18/3

7/7

32

7

18/4

7/8

33

8

19/1

8/1

34

9

19/2

8/2

35

10

19/3

8/3

36

11

19/4

8/4

37

12

20/1

8/5

38

13

20/2

8/6

39

14

20/3

8/7

40

15

20/4

8/8

41

16

21/1

9/1

42

17

21/2

9/2

43

18

21/3

9/3

44

19

21/4

9/4

45

20

22/1

9/5

46

21

22/2

9/6

47

22

22/3

9/7

48

23

22/4

9/8

49

24

23/1

10/1

26

1

Line 73 to 96 or POTS 73 to 96

23/2

10/2

27

2

23/3

10/3

28

3

23/4

10/4

29

4

24/1

10/5

30

5

24/2

10/6

31

6

24/3

10/7

32

7

24/4

10/8

33

8

25/1

11/1

34

9

25/2

11/2

35

10

25/3

11/3

36

11

25/4

11/4

37

12

26/1

11/5

38

13

26/2

11/6

39

14

26/3

11/7

40

15

26/4

11/8

41

16

27/1

12/1

42

17

27/2

12/2

43

18

27/3

12/3

44

19

27/4

12/4

45

20

28/1

12/5

46

21

28/2

12/6

47

22

28/3

12/7

48

23

28/4

12/8

49

24

31/1

13/1

26

1

Line 97 to 120 or POTS 97 to 120

31/2

13/2

27

2

31/3

13/3

28

3

31/4

13/4

29

4

32/1

13/5

30

5

32/2

13/6

31

6

32/3

13/7

32

7

32/4

13/8

33

8

33/1

14/1

34

9

33/2

14/2

35

10

33/3

14/3

36

11

33/4

14/4

37

12

34/1

14/5

38

13

34/2

14/6

39

14

34/3

14/7

40

15

34/4

14/8

41

16

35/1

15/1

42

17

35/2

15/2

43

18

35/3

15/3

44

19

35/4

15/4

45

20

36/1

15/5

46

21

36/2

15/6

47

22

36/3

15/7

48

23

36/4

15/8

49

24

37/1

16/1

26

1

Line 121 to 128 or POTS 121 to 128

37/2

16/2

27

2

37/3

16/3

28

3

37/4

16/4

29

4

38/1

16/5

30

5

38/2

16/6

31

6

38/3

16/7

32

7

38/4

16/8

33

8

B.2.4 Port Mapping Table for Building MC Cables

Table B-9 provides the Champ pins and MC port mapping information needed to build your own MC cables.


Table B-9: Port Mapping for Building MC Cables
Connector Champ Pins MC Slot/Line
Tip Ring

J39

xDSL

Slots 3 through 8

(pins 25 and 50 are not used)

1

2

6/1

3

4

6/2

5

6

6/3

7

8

6/4

9

10

7/1

11

12

7/2

13

14

7/3

15

16

7/4

17

18

8/1

19

20

8/2

21

22

8/3

23

24

8/4

26

27

5/1

28

29

5/2

30

31

5/3

32

33

5/4

34

35

4/1

36

37

4/2

38

39

4/3

40

41

4/4

42

43

3/1

44

45

3/2

46

47

3/3

48

49

3/4

J40

xDSL

Slots 1, 2, 21, and 22

(pins 9 through 25 are not used)

1

2

22/1

3

4

22/2

5

6

22/3

7

8

22/4

26

27

21/1

28

29

21/2

30

31

21/3

32

33

21/4

34

35

2/1

36

37

2/2

38

39

2/3

40

41

2/4

42

43

1/1

44

45

1/2

46

47

1/3

48

49

1/4

J41

xDSL

Slots 23 through 23

(pins 25 and 50 are not used)

1

2

26/1

3

4

26/2

5

6

26/3

7

8

26/4

9

10

27/1

11

12

27/2

13

14

27/3

15

16

27/4

17

18

28/1

19

20

28/2

21

22

28/3

23

24

28/4

26

27

25/1

28

29

25/2

30

31

25/3

32

33

25/4

34

35

24/1

36

37

24/2

38

39

24/3

40

41

24/4

42

43

23/1

44

45

23/2

46

47

23/3

48

49

23/4

J42

xDSL

Slots 13 through 18

(pins 25 and 50 are not used)

1

2

17/1

3

4

17/2

5

6

17/3

7

8

17/4

9

10

18/1

11

12

18/2

13

14

18/3

15

16

18/4

17

18

13/1

19

20

13/2

21

22

13/3

23

24

13/4

26

27

16/1

28

29

16/2

30

31

16/3

32

33

16/4

34

35

15/1

36

37

15/2

38

39

15/3

40

41

15/4

42

43

14/1

44

45

14/2

46

47

14/3

48

49

14/4

J43

xDSL

Slots 19, 20, 37, and 38

(pins 9 through 25 and 50 are not used)

1

2

20/1

3

4

20/2

5

6

20/3

7

8

20/4

26

27

19/1

28

29

19/2

30

31

19/3

32

33

19/4

34

35

38/1

36

37

38/2

38

39

38/3

40

41

38/4

42

43

37/1

44

45

37/2

46

47

37/3

48

49

37/4

J44

xDSL

Slots 31 through 36

(pins 25 and 50 are not used)

1

2

35/1

3

4

35/2

5

6

35/3

7

8

35/4

9

10

36/1

11

12

36/2

13

14

36/3

15

16

36/4

17

18

31/1

19

20

31/2

21

22

31/3

23

24

31/4

26

27

34/1

28

29

34/2

30

31

34/3

32

33

34/4

34

35

33/1

36

37

33/2

38

39

33/3

40

41

33/4

42

43

32/1

44

45

32/2

46

47

32/3

48

49

32/4

B.3 Standard Telco Color Chart

In designing the cables for the Cisco 6100 Series connections, Cisco used a standard telco color chart. Table B-10 lists the colors used for the Cisco 6100 Series cables.


Table B-10: Standard Telco Color Chart
Wire Color P1 Wire Color P2 Wire Color P1 Wire Color P2

Wht/blu

1

Wht/blu

1

Grn/blk

38

Grn/blk

38

Blu/wht

26

Blu/wht

26

Blk/brn

14

Blk/brn

14

Wht/org

2

Wht/org

2

Brn/blk

39

Brn/blk

39

Org/wht

27

Org/wht

27

Blk/gry

15

Blk/gry

15

Wht/grn

3

Wht/grn

3

Gry/blk

40

Gry/blk

40

Grn/wht

28

Grn/wht

28

Yel/blu

16

Yel/blu

16

Wht/brn

4

Wht/brn

4

Blu/yel

41

Blu/yel

41

Brn/wht

29

Brn/wht

29

Yel/org

17

Yel/org

17

Wht/gry

5

Wht/gry

5

Org/yel

42

Org/yel

42

Gry/wht

30

Gry/wht

30

Yel/grn

18

Yel/grn

18

Red/blu

6

Red/blu

6

Grn/yel

43

Grn/yel

43

Blu/red

31

Blu/red

31

Yel/brn

19

Yel/brn

19

Red/org

7

Red/org

7

Brn/yel

44

Brn/yel

44

Org/red

32

Org/red

32

Yel/gry

20

Yel/gry

20

Red/grn

8

Red/grn

8

Gry/yel

45

Gry/yel

45

Grn/red

33

Grn/red

33

Vio/blu

21

Vio/blu

21

Red/brn

9

Red/brn

9

Blu/vio

46

Blu/vio

46

Brn/red

34

Brn/red

34

Vio/org

22

Vio/org

22

Red/gry

10

Red/gry

10

Org/vio

47

Org/vio

47

Gry/red

35

Gry/red

35

Vio/grn

23

Vio/grn

23

Blk/blu

11

Blk/blu

11

Grn/vio

48

Grn/vio

48

Blu/blk

36

Blu/blk

36

Vio/brn

24

Vio/brn

24

Blk/org

12

Blk/org

12

Brn/vio

49

Brn/vio

49

Org/blk

37

Org/blk

37

Vio/gry

25

Vio/gry

25

Blk/grn

13

Blk/grn

13

Gry/vio

50

Gry/vio

50