cc/td/doc/product/dsl_prod/c6100/userdoc/rel240
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Software Download Events

Software Download Events

This chapter explains how to diagnose and handle software download events generated by the Cisco 6100 Series system. The following information is presented for each of the events:

If none of the actions presented for the event are successful, contact the Cisco Technical Assistance Center (TAC) for additional support.


Note Refer to "Cisco 6100 Series System Event Troubleshooting" for detailed information on viewing events in the ViewRunner management software. Refer to "Event Guidelines and Definitions" for detailed information on event severity guidelines and alarm event status changes.

Table 17-1 lists software download events and their IDs, definition, severity, and description. A detailed explanation of these events and corrective actions required (if any) is located in subsections in this chapter.


Table 17-1: Software Download Events
ID Definition Severity Description

1

MUM_TFTPING_FAULT

Minor

TFTP file transfer started

2

MUM_TFTP_SUCCESSFUL

Info

TFTP file transfer was successful

3

MUM_TFTP_TIMEOUT_FAULT

Minor

No DATA packet from server for 5 seconds after a RRQ or ACK packet was sent

4

MUM_FILE_NOT_FOUND_FAULT

Minor

Received something other than a DATA packet or received a out of sequence DATA packet

5

MUM_CHKSUM_FAIL_FAULT

Minor

TFTP file transfer failed: checksum was incorrect

6

MUM_SIZE_CHK_FAULT

Minor

TFTP file transfer failed: file size was incorrect

7

MUM_DB_WRITE_FAULT

Minor

TFTP file transfer failed; image could not be written to Cisco 6100 Series database

8

MUM_DB_CLEAN_FAULT

Minor

TFTP file transfer failed: could not clean database for TFTP retry

9

MUM_TFTP_GENERAL_FAULT

Minor

TFTP device driver init or open failed


Note Events with an id less than 128 are specific to the module in alarm. Events with an id value greater than or equal to 128 are system-wide events.

17.1 TFTP File Transfer Started

Event Summary

ID Event Name Severity

1

MUM_TFTPING_FAULT

Minor

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

TFTP file transfer started

Impact

There is no impact. This event signifies that the TFTP file transfer of the image has started. The image is transferring from the server to the Cisco 6100 Series system.

Action

No action is required. Wait for status of the image transfer.

17.2 TFTP File Transfer Successful

Event Summary

ID Event Name Severity

2

MUM_TFTP_SUCCESSFUL

Info

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

TFTP file transfer was successful

Impact

There is no impact. This event signifies that the TFTP file transfer of the image was successfully transferred from the server to the Cisco 6100 Series system.

Action

No action required.

17.3 TFTP Timeout During Download

Event Summary

ID Event Name Severity

3

MUM_TFTP_TIMEOUT_FAULT

Minor

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

No DATA packet from server for 5 seconds after a RRQ or ACK packet was sent

Impact

The image did not transfer because of a timeout. This could occur as the result of invalid IP addresses, a slow network, or a network failure.

Action

Step 1 Verify that the tftp server is configured correctly under a Solaris environment.

Step 2 Verify that the link to the tftpboot directory is created properly. Refer to the ViewRunner for HP OpenView Installation and Administration Guide for more information.

Step 3 Verify that the IP addresses are correct.

Step 4 Verify that the network is working correctly.

Step 5 Try the upgrade procedure again.

17.4 TFTP File Not Found

Event Summary

ID Event Name Severity

4

MUM_FILE_NOT_FOUND_FAULT

Minor

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

Received something other than a DATA packet or received a out of sequence DATA packet

Impact

The requested image to download from the server could not be downloaded or network synchronization errors occurred.

Action

Step 1 Verify that the image exists in the specified path with the correct file access permissions.

Step 2 Verify network connectivity.

Step 3 Verify the IP addresses.

17.5 TFTP File Transfer Failed: Checksum was Incorrect

Event Summary

ID Event Name Severity

5

MUM_CHKSUM_FAIL_FAULT

Minor

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

TFTP file transfer failed: checksum was incorrect

Impact

The image obtained from the server failed the CRC calculation.

Action

Verify that the CRC number in the rdf file is correct for the image and retry.

17.6 TFTP File Transfer Failed: File Size was Incorrect

Event Summary

ID Event Name Severity

6

MUM_SIZE_CHK_FAULT

Minor

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

TFTP file transfer failed: file size was incorrect

Impact

The image obtained from the server failed the size check computation.

Action

Verify that the size parameter in the rdf file is correct and retry.

17.7 TFTP File Transfer Failed

Event Summary

ID Event Name Severity

7

MUM_DB_WRITE_FAULT

Minor

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

TFTP file transfer failed; image could not be written to Cisco 6100 Series system database

Impact

A serious error occurred when the image was written to the Flash database. Flash may be full.

Action

Step 1 Try the upgrade procedures again.

Step 2 If this failure occurs again, clear Flash and NVRAM and reset the system controller (SC) module before you attempt to perform the upgrade again.

17.8 TFTP File Transfer Failed: Could Not Clean Database for TFTP Retry

Event Summary

ID Event Name Severity

8

MUM_DB_CLEAN_FAULT

Minor

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

TFTP file transfer failed: could not clean database for TFTP retry

Impact

A serious error occurred. The database in which the image is stored could not be cleaned.

Action

Step 1 Try the upgrade procedures again.

Step 2 If this failure occurs again, clear Flash and NVRAM and reset the system controller (SC) module before you attempt to perform the upgrade again.

17.9 TFTP file transfer failed

Event Summary

ID Event Name Severity

9

MUM_TFTP_GENERAL_FAULT

Minor

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

TFTP device driver init or open failed

Impact

A serious error occurred when the TFTP device driver initialization or open failed.

Action

Step 1 Reset the system controller (SC) module and perform the upgrade again.

Step 2 If the error persists, clear the Flash and NVRAM and reset the SC module before you perform the upgrade again.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Tue Nov 16 15:45:25 PST 1999
Copyright 1989-1999©Cisco Systems Inc.