cc/td/doc/product/dsl_prod/c6100/userdoc/rel240
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Line Concentration Chassis Events

Line Concentration Chassis Events

This chapter explains how to diagnose and handle line concentration chassis (LCC) events generated by the Cisco 6100 Series system. The following information is presented for each of the events:

If none of the actions presented for the event are successful, contact the Cisco Technical Assistance Center (TAC) for additional support.


Note Refer to "Cisco 6100 Series System Event Troubleshooting" for detailed information on viewing events in the ViewRunner management software. Refer to "Event Guidelines and Definitions" for detailed information on event severity guidelines and alarm event status changes.

Table 9-1 lists LCC events and their IDs, definition, severity, and description. A detailed explanation of these events and corrective actions required (if any) is located in subsections in this chapter.


Table 9-1: Line Concentration Chassis Events
ID Definition Severity Description

1

CCNX_OLD_CPE_DETECT

Critical

CPE not timer enabled


Note Events with an id less than 128 are specific to the module in alarm. Events with an id value greater than or equal to 128 are system-wide events.

9.1 CPE Not Timer Enabled

Event Summary

ID Event Name Severity

1

CCNX_OLD_CPE_DETECT

Critical

Description

The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:

CPE not timer enabled

Impact

The CPE detection feature is used to discover CPE gear that is not capable of performing Idle or Session timeouts. During training, the CPE detection feature determines if the CPE equipment can be timer enabled. If the equipment can be timer enabled, training will continue. If the equipment cannot be timer enabled, an alarm is generated in ViewRunner and training will not be successful until the Cisco 660, Cisco 665, or Cisco 675 is updated to at least version 2.01. The line port or modem port will not train successfully until the Cisco 660, 665, or 675 is updated to at least version 2.0.1.

Action

Upgrade the CPE to at least version 2.0.1.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Tue Nov 16 15:39:16 PST 1999
Copyright 1989-1999©Cisco Systems Inc.