This chapter explains how to diagnose and handle DMT-2 modem events generated by the Cisco 6100 Series system. The following information is presented for each of the events:
If none of the actions presented for the event are successful, contact the Cisco Technical Assistance Center (TAC) for additional support.
Table 5-1 lists DMT-2 modem events and their IDs, definition, severity, and description. A detailed explanation of these events and corrective actions required (if any) is located in subsections in this chapter.
| ID | Definition | Severity | Description |
|---|---|---|---|
19 | CCNX_MODEM_LATENCY_PATH_NOT_AVAIL | Major | CPE modem unable to support provisioned latency path (Interleaved/Fast) |
20 | SAD_EVENT_NE_FAST_FEC | Info | Near end fast path FEC Correction |
21 | SAD_EVENT_NE_INTL_FEC | Info | Near end interleaved path FEC Correction |
22 | SAD_EVENT_NE_FAST_CRC | Info | Near end fast path CRC error |
23 | SAD_EVENT_NE_INTL_CRC | Info | Near end interleaved path CRC error |
24 | SAD_EVENT_NE_SEF_DEFECT | Minor | Near end loss of framing defect |
25 | SAD_EVENT_NE_SEF_FAILURE | Major | Near end loss of framing failure |
28 | SAD_EVENT_NE_INTL_LOD | Info | Near end interleave path LOD error |
29 | SAD_EVENT_NE_FAST_LOD | Info | Near end fast path LOD error |
30 | SAD_EVENT_NE_INTL_HEC | Info | Near end interleave path HEC error |
31 | SAD_EVENT_NE_FAST_HEC | Info | Near end fast path HEC error |
32 | SAD_EVENT_FE_FAST_FEC | Info | Far end fast path FEC correction |
33 | SAD_EVENT_FE_INTL_FEC | Info | Far end interleave path FEC correction |
34 | SAD_EVENT_FE_FAST_CRC | Info | Far end fast path CRC error |
35 | SAD_EVENT_FE_INTL_CRC | Info | Far end interleave path CRC error |
36 | SAD_EVENT_FE_SEF_DEFECT | Minor | Far end loss of framing defect |
37 | SAD_EVENT_FE_SEF_FAILURE | Major | Far end loss of framing failure |
40 | SAD_EVENT_FE_INTL_LOD | Info | Far end interleave path LOD error |
41 | SAD_EVENT_FE_FAST_LOD | Info | Far end fast path LOD error |
42 | SAD_EVENT_FE_INTL_HEC | Info | Far end interleave path HEC error |
43 | SAD_EVENT_FE_FAST_HEC | Info | Far end fast path HEC error |
| ID | Event Name | Severity |
|---|---|---|
19 | CCNX_MODEM_LATENCY_PATH_NOT_AVAIL | Major |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
CPE modem unable to support provisioned latency path (Interleaved/Fast)The subscriber has been provisioned to use of a latency path which is not supported by the module or the CPE. Because the latency path is not supported, no data will be passed once the session is established.
Re-provision the subscriber. By default, re-provision back to latency.
| ID | Event Name | Severity |
|---|---|---|
20 | SAD_EVENT_NE_FAST_FEC | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Near end fast path FEC CorrectionThere has been a near end correction in the fast path. There is no impact on the session.
No action is needed.
| ID | Event Name | Severity |
|---|---|---|
21 | SAD_EVENT_NE_INTL_FEC | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Near end interleaved path FEC CorrectionThere has been a near end correction in the interleaved path. There is no impact on the session.
No action is needed.
| ID | Event Name | Severity |
|---|---|---|
22 | SAD_EVENT_NE_FAST_CRC | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Near end fast path CRC errorA near end CRC error has been detected in the fast path. There is no long-term impact on the session.
No action is needed.
| ID | Event Name | Severity |
|---|---|---|
23 | SAD_EVENT_NE_INTL_CRC | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Near end interleaved path CRC errorA near end CRC error has been detected in the interleaved path. There is no long-term impact on the session.
No action is needed.
| ID | Event Name | Severity |
|---|---|---|
24 | SAD_EVENT_NE_SEF_DEFECT | Minor |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Near end loss of framing defectA severely errored frame has been detected, which could indicate a loss of signal in progress or excessive noise on the session.
No action needed. If the problem persists, the system will drop the session and re-establish the session.
| ID | Event Name | Severity |
|---|---|---|
25 | SAD_EVENT_NE_SEF_FAILURE | Major |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Near end loss of framing failureA severely errored frame has been detected, which could indicate a loss of signal in progress or excessive noise on the session.
No action needed. If the problem persists, the system will drop the session and re-establish the session.
| ID | Event Name | Severity |
|---|---|---|
28 | SAD_EVENT_NE_INTL_LOD | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Near end interleave path LOD errorA near end interleaved loss of delineation has occurred, which could indicate a loss of signal in progress or excessive noise on the session.
No action needed. If the problem persists, the system will drop the session and re-establish the session.
| ID | Event Name | Severity |
|---|---|---|
29 | SAD_EVENT_NE_FAST_LOD | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Near end fast path LOD errorA near end fast path loss of delineation has occurred, which could indicate a loss of signal in progress or excessive noise on the session.
No action needed. If the problem persists, the system will drop the session and re-establish the session.
| ID | Event Name | Severity |
|---|---|---|
30 | SAD_EVENT_NE_INTL_HEC | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Near end interleave path HEC errorA near end HEC error has been detected in the interleaved path. There is no long-term impact on the session.
No action is needed.
| ID | Event Name | Severity |
|---|---|---|
31 | SAD_EVENT_NE_FAST_HEC | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Near end fast path HEC errorA near end fast path HEC error has been detected. There is no long-term impact on the session.
No action is needed.
| ID | Event Name | Severity |
|---|---|---|
32 | SAD_EVENT_FE_FAST_FEC | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Far end fast path FEC correctionThere is no long-term impact on the session.
No action is needed.
| ID | Event Name | Severity |
|---|---|---|
33 | SAD_EVENT_FE_INTL_FEC | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Far end interleave path FEC correctionThere is no long-term impact on the session.
No action is needed.
| ID | Event Name | Severity |
|---|---|---|
34 | SAD_EVENT_FE_FAST_CRC | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Far end fast path CRC errorThere is no long-term impact on the session.
No action is needed.
| ID | Event Name | Severity |
|---|---|---|
35 | SAD_EVENT_FE_INTL_CRC | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Far end interleave path CRC errorThere is no long-term impact on the session.
No action is needed.
| ID | Event Name | Severity |
|---|---|---|
36 | SAD_EVENT_FE_SEF_DEFECT | Minor |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Far end loss of framing defectA severely errored frame has been detected, which could indicate a loss of signal in progress or excessive noise on the session.
No action needed. If the problem persists, the system will drop the session and re-establish the session.
| ID | Event Name | Severity |
|---|---|---|
37 | SAD_EVENT_FE_SEF_FAILURE | Major |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Far end loss of framing failureA severely errored frame has been detected, which could indicate a loss of signal in progress or excessive noise on the session.
No action needed. If the problem persists, the system will drop the session and re-establish the session.
| ID | Event Name | Severity |
|---|---|---|
40 | SAD_EVENT_FE_INTL_LOD | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Far end interleave path LOD errorA far end fast path loss of delineation has occurred, which could indicate a loss of signal in progress or excessive noise on the session.
No action needed. If the problem persists, the system will drop the session and re-establish the session.
| ID | Event Name | Severity |
|---|---|---|
41 | SAD_EVENT_FE_FAST_LOD | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Far end fast path LOD errorA far end fast path loss of delineation has occurred, which could indicate a loss of signal in progress or excessive noise on the session.
No action needed. If the problem persists, the system will drop the session and re-establish the session.
| ID | Event Name | Severity |
|---|---|---|
42 | SAD_EVENT_FE_INTL_HEC | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Far end interleave path HEC errorThere is no long-term impact on the session.
No action is needed.
| ID | Event Name | Severity |
|---|---|---|
43 | SAD_EVENT_FE_FAST_HEC | Info |
The following description appears in the ViewRunner for Windows Event History View dialog box or the ViewRunner for HP OpenView Error Events Browser:
Far end fast path HEC errorThere is no long-term impact on the session.
No action is needed.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Tue Nov 16 15:36:20 PST 1999
Copyright 1989-1999©Cisco Systems Inc.