cc/td/doc/product/dsl_prod/c6100/userdoc/rel220
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Specifications

Specifications

This appendix provides hardware, software, and special POTS cable specifications for the Cisco 6100.

B.1 Hardware Specifications

The following table details the hardware specifications for the 6100.


Table B-1: Hardware Specifications
Specification Description

Dimensions

9u (40.0005 cm) in a 23-in (58.42 cm) rack
23 in (68.42 cm) x 15.75 in (40.005 cm) x 12 in (30.48 cm)

Weight

Approximately 44 lbs.(multiplexer only)

Network Interface

ATM OC3c MMF, ATM OC3c SMF (IR), ATM DS3

ADSL Interface

CAP RADSL up to 7 Mbps downstream/1 Mbps upstream
DMT-RADSL up to 8 Mbps downstream/640 kbps upstream

Craft Interface

RS-232

Power Requirements

-48VDC, 11 Amps (fully loaded 400 line system)

CO Operating Requirements

GR-63-CORE (NEBS)
Temperature: -5 to 40º C (operating), -5 to 50º C (short term operating)
Altitude: -60 meters to 3200 meters
Humidity: 5 to 90% (non-condensing)

RT Operating Requirements

TR-NWT-057 (outside plant)
Temperature: -40 to 65º C (operating)
Altitude: -60 to 4000 meters
Humidity: 5 to 90% (non-condensing)

EMI/RF Certifications

UL1950, UL 1459, FCC Part 15,
Bellcore GR-63-CORE, GR-1089-CORE

Subtending (subsequent releases)

ATM DS3 Connections (non-redundant)

B.2 Software Specifications

The following table details the software specifications for the 6100.


Table B-2: Software Specifications
Specification Description

Management Protocols

SNMPv1, SNMPv2 (future), Telnet

Management Applications

Local Craft Interface
ViewRunner SNMP Manager

Management Interfaces

10BaseT Ethernet interface
Inband ATM via the network interface