After you have installed the Cisco 6100 modules and wired up your particular configuration, you must apply power and check each module's status indicators. The following sections discuss the status indicators on each 6100 module front panel.

9.1 LIM Front Panel

The following is an illustration showing the line interface module (LIM) front panel status indicators and a table describing their functions.


Figure 9-1: LIM Front Panel



Table 9-1: LIM Front Panel Indicators
LED State Function

STATUS

Green Blinking
Green Solid
Red
OFF

Self-test in progress
Status is OK
Self-test/Module failure
LIM power failure

LINE 1

Green Blinking


Green Solid
OFF

LIM port is detecting Digital Off-Hook (DOH) but is not configured with a subscriber or the configured subscriber is locked
Port is busy
Port is idle

LINE 2

Green Blinking

Green Solid
OFF

LIM port is detecting DOH but is not configured with a subscriber or the configured subscriber is locked
Port is busy
Port is idle

LINE 3

Green Blinking

Green Solid
OFF

LIM port is detecting DOH but is not configured with a subscriber or the configured subscriber is locked
Port is busy
Port is idle

LINE 4

Green Blinking

Green Solid
OFF

LIM port is detecting DOH but is not configured with a subscriber or the configured subscriber is locked
Port is busy
Port is idle

9.2 ATU-C Front Panel

The following is an illustration showing the ATU-C front panel status indicators and a table describing their functions.


Figure 9-2: ATU-C Front Panel



Table 9-2: ATU-C Front Panel Indicators
LED State Function

STATUS

Green Blinking
Green Solid
Red
OFF

Self-test in progress
Status is OK
Self-test/Module failure
ATU-C power failure

ACTIVE

Green
OFF

Module is activated
Not in service

ATU-C1

Green
OFF

Modem 1 is trained
Modem 1 is idle

ATU-C2

Green
OFF

Modem 2 is trained
Modem 2 is idle

9.3 LIM Controller Front Panel

The following is an illustration showing the LIM controller front panel status indicators and a table describing their functions.


Figure 9-3: LIM Controller Front Panel



Table 9-3: LIM Controller Front Panel Indicators
LED State Function

STATUS

Green Blinking
Green Solid
Red
OFF

Self-test in progress
Status is OK
Self-test/module failure
Line controller failure

ACTIVE

Green
OFF

Module is activated (not standby)
Module is in standby mode

9.4 Network Interface Module Front Panel

Figure 9-4 and Figure 9-5 show the three types of network interface (NI) module front panels available with the 6100. The optical front panels are labeled differently for OC3 single-mode fiber (SMF) and OC3 multi-mode fiber (MMF). A table follows each illustration describing the functions of their front panel status indicators.


Figure 9-4: OC3c Network Interface Front Panel



Table 9-4: OC3c Network Interface Front Panel Indicators
LED State Function

STATUS

Green Blinking
Green Solid
Red
OFF

Self-test in progress
Status is OK
Self-test/Module failure
NI module failure

ACTIVE

Green Solid
OFF

Module is active
Module is in standby mode


Figure 9-5:
DS3 Network Interface Front Panel



Table 9-5: DS3 Network Interface Front Panel Indicators
LED State Function

STATUS

Green Blinking
Green Solid
Red
OFF

Self-test in progress
Status is OK
Self-test/Module failure
NI module failure

ACTIVE

Green
OFF

Module is active
Module is in standby mode

9.5 DS3 Subtend Module Front Panel

The following is an illustration showing the DS3 subtend module front panel status indicators and a table describing their functions.


Figure 9-6: DS3 Subtend Module Front Panel



Table 9-6: DS3 Subtend Module Front Panel Indicators
LED State Function

STATUS

Green Blinking
Green Solid
Red

Self-test in progress
Status is OK
Self-test/Module failure

ACTIVE

Green
OFF

Module is active
Module is in standby mode

PORT 1

LOS

Green Solid

Red

Port 1 has a proper DS3 signal to the far end connection

Port 1 has detected a loss of signal condition from the subtended 6100

LOF

Green Solid

Red

Port 1 has DS3 frame sync to the far end connection.

Port 1 has detected a loss of frame condition from the subtended 6100

OCD

Green Solid

Red

Port 1 has achieved cell delineation from/to the far end connection

Port 1 has detected a loss of cell delineation condition from the subtended 6100

FERF

Green Solid

Red

The far end connection to port 1 is receiving signals

Port 1 has detected a receiver failure in the far end equipment

PORT 2

LOS

Green Solid

Red

Port 2 has a proper DS3 signal to the far end connection

Port 2 has detected a lost of signal condition from the subtended 6100

LOF

Green Solid

Red

Port 2 has DS3 frame sync to the far end connection

Port 2 has detected a loss of frame condition from the subtended 6100

OCD

Green Solid

Red

Port 2 has achieved cell delineation from/to the far end connection

Port 2 has detected a loss of cell delineation condition from the subtended 6100

FERF

Green Solid

Red

The far end connection to port 2 is receiving signals

Port 2 has detected a receiver failure in the far end equipment

9.6 System Controller Front Panel

The following is an illustration showing the system controller (SC) front panel status indicators and a table describing their functions.


Figure 9-7: System Controller Front Panel



Table 9-7: System Controller Front Panel Indicators
LED State Function

STATUS

Green Blinking
Green Solid
Red
OFF

Self-test in progress
Status is OK
Self-test/module failure
SC failure

ACTIVE

Green
OFF

Module is active
Module is in standby mode

ALARM

Red Blinking
Red Solid

Unacknowledged Alarm
Alarm acknowledged (ACO active)