cc/td/doc/product/dsl_prod/c6100
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

System I/O Card FRU Installation and Replacement Notes

System I/O Card FRU Installation and Replacement Notes

Product Number: 6100-SYS-IO-3=

This document provides information about installing and replacing the Cisco 6100 Series system I/O card. The system I/O card is a field-replaceable unit (FRU) and is installed on a multiplexer chassis (MC) backplane in a subtended network configuration.


Note Older versions of the system I/O card, the DS3 subtending I/O card, or the DS3 subtend host module (STM) cannot be mixed with the newer versions. The system I/O card (version 6100-SYS-IO-3=), the DS3 subtending I/O card (version 6100-ST-IO-3-DS3=) and the DS3 STM (version 6100-ST-3-DS3=) are compatible with each other. If you mix older versions with newer versions, the hardware components will not work properly.

If you need to replace all three hardware components at the same time, follow the removal and replacement procedures provided in the DS3 Retrofit Kit Release Notes located on the World Wide Web at http://www.cisco.com/univercd/cc/td/doc/product/dsl_prod/c6100/index.htm.

1. Contents

This document includes the following sections:

2. Subtended Network Configuration Overview

A subtended network configuration

The term subtending refers to the host MC, and subtended refers to the downstream MC in a subtended network.

Figure 1 shows a subtending tree. The subtending host MC at the top of the subtending tree connects directly to the ATM switch. You can have two subtended node MCs connected to the first subtending host MC located at the top of the subtending tree. One or both of these subtended node MCs can also become a subtending host MC and therefore have one or two subtended node MCs connected to them.


Figure 1: Subtended Cisco 6100 Series System Network


You can subtend an MC to three tiers, with up to six MCs, all connecting through one subtending host MC to the ATM backbone (see Figure 1).

In Figure 2, the DS3 subtend host module (STM) is installed in slot 9 of the subtending host MC. A network interface (NI) module is located in slot 10. If you have

Figure 2 shows a subtending host MC and a subtended node MC with corresponding slot number assignments.


Figure 2: Subtending Host and Subtended Node MC Slot Assignments


All MCs have a system I/O card installed on the MC backplane. In addition to the system I/O card, a DS3 subtending I/O card is installed on the subtending host MC backplane.

3. System I/O Card Overview

The system I/O card provides the following:

On the system I/O card, the receive DS3 Bayonet-Neill-Concelman (BNC) connector is designated as J4, and the transmit DS3 BNC connector is designated as J3. Figure 3 shows the system I/O card that is currently in the field.


Figure 3: System I/O Card



Note There are two DS3 jumpers on the system I/O card. The DS3 jumpers connect the
BNC shield to the chassis ground. Both the receive DS3 jumper (P2) and the transmit DS3 jumper (P1) are installed on the system I/O card when it ships.

In a subtended network configuration, the system I/O card is attached to the MC connectors P3 and P9, two 2-mm hard metric (HM) module connectors. Figure 4 shows the location of the system I/O card in relation to the DS3 subtending I/O card on the MC backplane.


Figure 4: System I/O Card and DS3 Subtending I/O Card Locations


4. System I/O Card Cabling

Coaxial connections for cabling are located on the system I/O card and the DS3 subtending I/O card. The transmit and receive DS3 BNC connectors on the DS3 subtending I/O card are connected to the transmit and receive DS3 BNC connectors on the system I/O card (see Figure 5). Refer to the Cisco 6100 Series User Guide for cabling the system I/O card in a version of the Cisco 6100 Series system that is earlier than Release 2.4.0.


Figure 5: Cabling for Subtended Network Configuration



Note The system I/O card and DS3 subtending I/O card coaxial cables are not provided by Cisco Systems, Inc.

5. Installation Prerequisites

This section describes hardware requirements and lists the parts and tools used to install the system I/O card.

5.1 Hardware Requirements

The system I/O card is installed on all MC backplanes and it is not a stand-alone product. In order for a system I/O card to work properly on a subtending host MC, you must install both a DS3 subtending I/O card and DS3 STM.

5.2 Part and Tool Requirements

To install or replace the system I/O card, you need the following parts and tools:

6. General Safety Precautions and Maintenance Guidelines

This section covers the following topics:

6.1 General Safety Precautions

Before working on the equipment, be aware of standard safety practices and the hazards involved in working with electrical circuitry to prevent accidents. Adhere to the following cautions and warnings for safe and hazard-free installation.


Note To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information for the Cisco 6100 Series System document.
Caution Proper ESD protection is required whenever you handle Cisco DSLAM equipment. Installation and maintenance personnel should be properly grounded using ground straps to eliminate the risk of ESD damage to the equipment. Modules are subject to ESD damage whenever they are removed from the chassis.
Caution Be careful when you remove the standoff screws and reinsert the screws into the screw holes on the backplane so that the backplane circuitry does not become damaged.
Caution If the modules are installed when you apply power to the system, you could damage the modules and the chassis.
Caution If fuses are already installed in the fuse and alarm panel, remove them. You can replace the fuses after the system I/O card is installed. Do not power up the system while you install and connect the system I/O card.
Warning The customer 48 volt power system must provide reinforced insulation between the primary AC power and the 48 VDC output.
Warning There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Warning Class 1 laser product.
Warning Use copper conductors only.
Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Warning The DS3 ports are not intended to be connected to cables that run outside the building where it is installed. For any connections outside the building, the DS3 ports must be connected to a network termination unit (NTU). NTU devices should comply with appropriate national safety standards such as UL 1950, CSA 950, EN 60950, IEC 950, and AS 3260.
Warning Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed circuitry could constitute an energy hazard.
Warning Ethernet cables must be shielded when used in a central office environment.
Warning An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure that no exposed portion of the DC-input power source wire extends from the terminal block plug.
Warning Incorrect connection of this or connected equipment to a general purpose outlet could result in a hazardous situation.
Warning Read the installation instructions before you connect the system to its power source.
Warning Only trained and qualified personnel should be allowed to install, replace, or service
this equipment.
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.
Warning This unit has more than one power supply connection; all connections must be removed completely to completely remove power from the unit.
Warning To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Warning To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 104°F (40°C).
Warning Secure all power cabling when installing this unit to avoid disturbing field-wiring connections.
Warning The power supply circuitry for the equipment can constitute an energy hazard. Before you install or replace the equipment, remove all jewelry (including rings, necklaces, and watches). Metal objects can come into contact with exposed power supply wiring or circuitry inside the DSLAM equipment. This could cause the metal objects to heat up and cause serious burns or weld the metal object to the equipment.
Warning Ultimate disposal of this product should be handled according to all national laws and regulations.
Warning This unit is intended for installation in restricted access areas. A restricted access area is where access can only be gained by service personnel through the use of a special tool, lock and key, or other means of security, and is controlled by the authority responsible for the location
Warning Connect the unit only to DC power source that complies with the Safety Extra-Low Voltage (SELV) requirements in IEC 60950 based safety standards.
Warning This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations.
Warning Care must be given to connecting units to the supply circuit so that wiring is not overloaded.
Warning During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself.

6.2 Installation and Replacement Suggestions

The following are recommended installation and replacement practices:

Any card that is only partially connected to the backplane can disrupt system operation.

7. Installing the System I/O Card

Use the procedures in this section to install and cable the system I/O card.

Caution Proper ESD protection is required whenever you handle Cisco DSLAM equipment. Installation and maintenance personnel should be properly grounded using ground straps to eliminate the risk of ESD damage to the equipment. Modules are subject to ESD damage whenever they are removed from the chassis.

Note The MC is shipped with the system I/O card already installed on the MC backplane. If the system I/O card is missing from your MC backplane, you need to install it according to the procedures in this section.

Use the following steps to install a system I/O card on an MC backplane (subtending host or subtending node):

Step 1 Remove the optional rear door, if your system has one.

Step 2 Open the MC front door.

Step 3 Pull all of the modules away from the MC backplane connection.

Step 4 Pull all of the modules away from the line concentration chassis (LCC) backplane connection.

Step 5 Pull all of the modules away from the POTS splitter chassis (PSC) backplane connection:

Step 6 Remove the fuses from the fuse and alarm panel. By removing the fuses, the system is not powered while you install and connect the system I/O card.

Step 7 Locate the two backplane screws between connectors P3 and P9 on the MC backplane. Use a Phillips-head screwdriver to remove the two backplane screws. Keep these backplane screws for use when you install the plastic ESD shield.

Figure 6 shows Step 7 through Step 10.


Figure 6: System I/O Card Installation


Step 8 Use a one-quarter inch socket driver or wrench to screw two standoff screws into the locations formerly occupied by the two screws you removed in Step 7. Tighten the standoff screws using the one-quarter inch socket driver or wrench.

Caution Be careful when you remove the standoff screws and reinsert the screws into the screw holes on the backplane so that the backplane circuitry does not become damaged.

Step 9 Position and align the holes on the system I/O card over the two standoff screws and gently press the system I/O card onto the MC connectors P3 and P9 on the MC backplane.

Step 10 Use a one-quarter inch socket driver or wrench to screw two additional standoff screws into the screw holes in the system I/O card and into the original standoff screws added in Step 8. Tighten the standoff screws using the one-quarter inch socket driver or wrench.

Step 11 Attach one end of a coaxial cable (type 734A, type 735A, or equivalent) to the transmit DS3 BNC connector (TX1) for the DS3 subtending I/O card on the subtending host MC backplane. Figure 7 shows cabling for a subtended network configuration.


Figure 7: Cabling for Subtended Network Configuration


Step 12 Add ferrites to the coaxial cables that you use to cable the DS3 subtending I/O card to the system I/O card to reduce the radiation/EMI susceptibility to high frequency noise between 30 and 200 MHz. Use either the ferrites shipped with the DS3 NI module or ferrites that yield an impedance greater than 200 ohms +/- 20 percent at 100 MHz.

If you are using


Figure 8: Thick Coaxial Cable Through Ferrite



Figure 9: Thin Coaxial Cable Through Ferrite


Step 13 Attach a ferrite as close as possible to the remaining end of the cable (see Figure 8 or Figure 9 for ferrite installation). Tie wrap the cable directly behind the ferrite.

Step 14 Attach the end of the cable used in Step 13 to the receive DS3 BNC connector (RX) for the system I/O card on the subtended node MC backplane.

Step 15 Attach one end of a coaxial cable to the receive DS3 BNC connector (RX1) for the DS3 subtending I/O card on the subtending host MC backplane.

Step 16 Attach the ferrite as close as possible to the receive DS3 BNC connector (RX1) on the DS3 subtending I/O card (see Figure 8 or Figure 9 for ferrite installation). Tie wrap the cable directly behind the ferrite.

Step 17 Attach a ferrite as close as possible to the remaining end of the cable (see Figure 8 or Figure 9 for ferrite installation). Tie wrap the cable directly behind the ferrite.

Step 18 Attach the end of the cable used in Step 17 to the transmit DS3 BNC connector (TX) for the system I/O card on the subtended node MC backplane.

Step 19 Tie wrap the transmit and receive cables coming from the DS3 subtending I/O card where the cables meet after coming from the ferrites and every 1 foot thereafter for a total of 15 feet, as shown in Figure 10.


Figure 10: Ferrite Close to DS3 BNC Connectors on DS3 Subtending I/O Card


Step 20 Tie wrap the transmit and receive cables coming from the system I/O card where the cables meet after coming from the ferrites and every 1 foot thereafter for a total of 15 feet, as shown in Figure 11.


Figure 11: Ferrites Close to DS3 BNC Connectors on System I/O Card


Step 21 Complete the following steps to connect the system I/O card to the network if a DS3 NI module is installed in slot 10 of the subtending host MC at the top of the subtending tree:

Step 22 Install the plastic ESD shield over the system I/O card using the following steps:


Figure 12: Plastic ESD Shield Installation


Caution If the modules are installed when you apply power to the system, you could damage the modules and the chassis.

Step 23 Reinsert the fuses in the fuse and alarm panel. When you reinsert the fuses, the system powers on.

Step 24 Reseat all of the modules in the MC, LCC, and PSC. It is important that you accomplish each step completely before moving on to the next step.

Step 25 Verify that the MC front door is attached to the MC and closed to achieve NEBS compliance. For more information on NEBS requirements, refer to the Regulatory Compliance and Safety Information for the Cisco 6100 Series System document.

Step 26 Use the following steps to connect the ViewRunner system to the MC:

Step 27 Close the optional rear door using the following steps:

8. Removing and Replacing the System I/O Card

The following sections describe how to remove and replace a system I/O card.

8.1 Removing a System I/O Card

Caution Proper ESD protection is required whenever you handle Cisco DSLAM equipment. Installation and maintenance personnel should be properly grounded using ground straps to eliminate the risk of ESD damage to the equipment. Modules are subject to ESD damage whenever they are removed from the chassis.

Use the following steps to remove a system I/O card from the MC backplane:


Note There are two versions of the system I/O card currently in the field. With the earlier version (prior to Release 2.4.0), the DS3 BNC connectors are located at the bottom left corner of the card and the 10BaseT management interface is located across the bottom of the card. The removal procedures are the same for each version of the system I/O card.

Step 1 Remove the optional rear door, if your system has one.

Step 2 Disconnect the ViewRunner system from the MC by removing the Ethernet cable.

Step 3 Open the MC front door.

Step 4 If you have a DS3 NI module installed in slot 10 of the MC, you need to disconnect the DS3 NI module from the network.

Step 5 Pull all of the modules away from the MC backplane connection.

Step 6 Pull all of the modules away from the LCC backplane connection.

Step 7 Pull all of the modules away from the PSC backplane connection.

Step 8 Remove the fuses from the fuse and alarm panel. By removing the fuses, the system is not powered while you install and connect the system I/O card.

Step 9 Remove the coaxial cables from the two DS3 BNC connectors (TX and RX) for the system I/O card on a subtended node MC backplane.

Step 10 Use a Phillips-head screwdriver to remove the two backplane screws that hold the plastic ESD shield over the system I/O card. Keep these backplane screws and the plastic ESD shield for use when you replace the system I/O card.

Step 11 Use a one-quarter inch socket driver or wrench to remove the two additional standoff screws that are attached to the system I/O card.

Step 12 Lift and disconnect the system I/O card from connectors P3 and P9, two 2-mm HM module connectors on the MC backplane. Figure 13 shows the system I/O card removal.


Figure 13: System I/O Card Removal


8.2 Replacing a System I/O Card

Caution Proper ESD protection is required whenever you handle Cisco DSLAM equipment. Installation and maintenance personnel should be properly grounded using ground straps to eliminate the risk of ESD damage to the equipment. Modules are subject to ESD damage whenever they are removed from the chassis.

Use the following steps to replace a system I/O card on the MC backplane:


Note Before you replace a system I/O card, please complete all of the steps in the "Removing a System I/O Card" section.

Step 1 Locate the two standoff screws that are between connectors P3 and P9. Tighten the standoff screws using a one-quarter inch socket driver or wrench.

Step 2 Position and align the holes on the system I/O card over the two standoff screws on the MC backplane and gently press the system I/O card onto the MC connectors P3 and P9 on the MC backplane.

Figure 14 shows the system I/O card replacement procedures.


Figure 14: System I/O Card Replacement


Step 3 Use a one-quarter inch socket driver or wrench to screw two additional standoff screws into the screw holes in the system I/O card and into the original standoff screws on the MC backplane. Tighten the standoff screws using the one-quarter inch socket driver or wrench.

Step 4 Complete the following steps to connect the system I/O card to the network if a DS3 NI module is installed in slot 10 of a subtending host MC at the top of the subtending tree:

Step 5 Locate the cable coming from the receive DS3 BNC connector (RX1) for the DS3 subtending I/O card on the subtending host MC.

Step 6 Attach the cable from Step 5 to the transmit DS3 BNC connector (TX) for the system I/O card on the subtended node MC.

Step 7 Locate the cable coming from the transmit DS3 BNC connector (TX1) for the DS3 subtending I/O card on the subtending host MC.

Step 8 Attach the cable from Step 7 to the receive DS3 BNC connector (RX) for the system I/O card on the subtended node MC.

Figure 15 shows cabling from a DS3 subtending I/O card to a system I/O card.


Figure 15: Cabling for a DS3 Subtending I/O Card and a System I/O Card


Step 9 Install the plastic ESD shield over the system I/O card using the following steps:


Figure 16: Plastic ESD Shield Installation


Caution If the modules are installed when you apply power to the system, you could damage the modules and the chassis.

Step 10 Reinsert the fuses in the fuse and alarm panel. When you reinsert the fuses, the system powers on.

Step 11 Reseat all of the modules in the MC, LCC, and PSC. It is important that you accomplish each step completely before moving on to the next step

Step 12 Verify that the MC front door is attached to the MC and closed to achieve NEBS compliance. For more information on NEBS requirements, refer to the Regulatory Compliance and Safety Information for the Cisco 6100 Series System document.

Step 13 Connect the ViewRunner system to the MC by attaching the Ethernet cable to the RJ-45 (10BaseT/LAN) connector on the system I/O card.

Step 14 Close the optional rear door using the following steps:

9. Standards and Certifications

Table 1 lists the DS3 subtending I/O card standards and certifications.


Table 1: Standards and Certifications
Category Description

NEBS Level 3

Bellcore GR-63-CORE, GR-1089-CORE

EMI

FCC Part 15, Class A

Safety

UL 1950, 3rd Edition

10. Related Documentation

The following sections list the CO and customer premises equipment (CPE) publications that relate to the Cisco DSL product family.

10.1 CO Publications

A complete list of all released Cisco 6100 Series system with NI-1 related documentation is available on the World Wide Web at http://www.cisco.com/univercd/cc/td/doc/product/dsl_prod/c6100/index.htm.

The following ViewRunner management software is used to provision and manage the Cisco 6100 Series system with NI-1. A complete list of all released ViewRunner documentation is available on the Word Wide Web.

10.2 CPE Publications

The Cisco CPE, also known as the Cisco 600 Series, is part of the Cisco end-to-end DSL product family. CPE comprises modems and routers at the customer site primarily used by home office and corporate LAN personnel. Most CPE uses the Cisco Broadband Operating System (CBOS) as its operating system. CBOS provides a comprehensive command set and web interface that allow you to configure your Cisco CPE modem or router.

A complete list of all released Cisco 600 Series documentation is available on the World Wide Web at http://www.cisco.com/univercd/cc/td/doc/product/dsl_prod/c600s/index.htm.

11. Cisco Connection Online

Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.

Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.

CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.

You can access CCO in the following ways:

For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.


Note If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco's Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com.

12. Documentation CD-ROM

Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.

If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.



hometocprevnextglossaryfeedbacksearchhelp
Posted: Tue Nov 16 17:27:50 PST 1999
Copyright 1989-1999©Cisco Systems Inc.