This chapter describes how to use the Cisco customer premises equipment (CPE) Commander settings to view and change Cisco 675 device settings. The Cisco CPE Commander works on PC platforms (Windows NT, Windows 95, and Windows 98) and Macintosh platforms.
After you log in to the Cisco CPE Commander, the Cisco CPE Commander windows appear. Use the Cisco CPE Commander fields and action buttons described in this section to run the CPE Commander software and manage the Cisco 675 device.
On both the PC and the MacIntosh platforms, the Cisco CPE Commander contains the following tabs:
The tabs are described in the following sections.
Use the Call tab to view the receive and transmit statistics for a connection. The Call tab includes the following information:
Figure 2-1 shows the Call tab as it appears on a PC platform.

Table 2-1 lists definitions for Call tab fields.
| Field Name | Description |
|---|---|
Number of bytes received for a specified connection. | |
Number of bytes transmitted for a specified connection. | |
Number of packets received for a specified connection. | |
Number of packets transmitted for a specified connection. | |
VPI for a specific connection. The VPI is hard-coded to equal 1. | |
VCI for a specific connection. Usually hard-coded to equal 1. | |
Connection State | The state of the connection. These states are described in Request for Comments (RFC) 1661, "The Point-to-Point Protocol (PPP)." Options include: Note See RFC 1661 for more information on these states. |
IPCP State | The state of the connection. These states are described in Request for Comments (RFC) 1661, "The Point-to-Point Protocol (PPP)." Options include:
|
Auth. Failures | Number of failed attempts at PPP authentication. |
Reset Stats | |
Disconnect/ | Connects or disconnects the ADSL link. When the ADSL link is:
|
Figure 2-2 shows the Call tab as it appears on a Macintosh platform.

Table 2-2 lists definitions for Call tab fields.
| Field Name | Description |
|---|---|
Number of bytes received for a specified connection. | |
Number of bytes transmitted for a specified connection. | |
Number of packets received for a specified connection. | |
Number of packets transmitted for a specified connection. | |
VPI for a specific connection. The VPI is hard-coded to equal 1. | |
VCI for a specific connection. Usually hard-coded to equal 1. | |
Connection State | The state of the connection. These states are described in Request for Comments (RFC) 1661, "The Point-to-Point Protocol (PPP)." Options include: Note See RFC 1661 for more infomation on these states. |
IPCP State | The state of the connection. These states are described in Request for Comments (RFC) 1661, "The Point-to-Point Protocol (PPP)." Options include:
|
Auth. Failures | Number of failed attempts at PPP authentication. |
Disconnect/ | Connects or disconnects the ADSL link. When the ADSL link is:
|
Use the Link tab to view the following information:
Figure 2-3 shows the Link tab as it appears on a PC platform.

Table 2-3 lists definitions for Link tab fields.
| Field Name | Description |
|---|---|
Bytes Rx | Number of bytes received. |
Number of bytes transmitted. | |
Number of packets received. | |
Number of packets transmitted. | |
ScalaRate. Your SP sets this rate. ScalaRate only applies to the upstream rate. | |
Link State | Status of the link between the Cisco 675 device and the far-end modem. Options include:
|
Number of times the Cisco 675 device attempted to connect to the far-end equipment but could not because the far-end equipment was busy. | |
Number between 12 and 45. This number describes the quality of the physical connection between the Cisco 675 device and far-end equipment. The higher the number, the better the quality of the physical connection. | |
When the timer type is Session, the Cisco 675 device drops the link when Elapsed Time equals the Timer Period. Note Your SP defines the timer types. | |
Idle Timer | When the timer type is Idle, the Cisco 675 device resets the Elapsed Time field when the link resumes activity. However, if the link remains inactive for the entire Timer Period, the Cisco 675 device drops the link. Note Your SP defines the timer types. |
Elapsed time of the timer type. Varies according to Timer Type. If the Timer Type is:
| |
Time period that, after elapsed, cues the Cisco 675 device to drop the link. Varies according to Timer Type. If the Timer Type is:
| |
Specifies the number of Reed-Solomon Corrected errors. Reed-Solomon is an Error Correction Code (ECC) that allows data that is being read or transmitted to be checked for errors and, if necessary, corrected immediately. | |
Specifies the number of Reed-Solomon uncorrected errors. | |
Cyclic Redundancy Check. Indicates that an error occurred during a transmission. Note It is normal for your system to exhibit a small number of CRC errors. | |
Downstream line rate. | |
Figure 2-4 shows the Link tab as it appears on a Macintosh platform.

Table 2-4 lists definitions for Link tab fields.
| Field Name | Description |
|---|---|
Number of bytes received. | |
Number of bytes transmitted. | |
Number of packets received. | |
Number of packets transmitted. | |
ScalaRate. Your SP sets this rate. ScalaRate only applies to the upstream rate. | |
Link State | Status of the link between the Cisco 675 device and the far-end modem. Options include:
|
Number of times the Cisco 675 device attempted to connect to the far-end equipment but could not because the far-end equipment was busy. | |
Number between 12 and 45. This number describes the quality of the physical connection between the Cisco 675 device and far-end equipment. The higher the number, the better the quality of the physical connection. | |
When the timer type is Session, the Cisco 675 device drops the link when Elapsed Time equals the Timer Period. Note Your SP defines the timer types. | |
Idle Timer | When the timer type is Idle, the Cisco 675 device resets the Elapsed Time field when the link resumes activity. However, if the link remains inactive for the entire Timer Period, the Cisco 675 device drops the link. Note Your SP defines the timer types. |
Elapsed time of the timer type. Varies according to Timer Type. If the Timer Type is:
| |
Time period that, after elapsed, cues the Cisco 675 device to drop the link. Varies according to Timer Type. If the Timer Type is:
| |
Specifies the number of Reed-Solomon Corrected errors. Reed-Solomon is an Error Correction Code (ECC) that allows data that is being read or transmitted to be checked for errors and, if necessary, corrected immediately. | |
Specifies the number of Reed-Solomon uncorrected errors. | |
Cyclic Redundancy Check. Indicates that an error occurred during a transmission. Note It is normal for your system to exhibit a small number of CRC errors. | |
Downstream line rate. | |
Connects or disconnects the ADSL link. When the ADSL link is:
|
Use the Device tab to view device information, such as the software type, version number and other attributes. The Media Access Control (MAC) address field is associated with the Cisco 675 device hardware also appears on the Device tab.
The Device tab includes three buttons that allow you to:
Figure 2-5 shows the Device tab as it appears on the PC platform.

The Device tab contains the following action items:



Figure 2-9 shows the Device tab as it appears on a Macintosh platform.

The Device tab contains the following action items:



![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Sep 3 09:39:10 PDT 1999