cc/td/doc/product/dsl_prod/c600s/c673
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Cisco 673 Connectors

Cisco 673 Connectors

A.1 Cisco 673 Rear Panel Connectors

Figure A-1 shows the connectors located on the rear panel of the Cisco 673 units.


Figure A-1: Rear View of the Cisco 673


The following ports are located on the backside of the Cisco 673.

A.1.1 LAN Interface

The LAN interface uses an Ethernet port that conforms to the IEEE 802.3 and 802.3u protocols and supports 10 or 100 MBps half-duplex data rates on category 3 (10 MBps) or category 5 (100 MBps) twisted-pair wire at a distance of up to 100 meters or less. The Ethernet connector is an RJ-45. Table A-1 shows the connector pinouts.

Ethernet Connector Pinouts


Table A-1: Ethernet Connector Pinouts
Pin Signal

1

TXD+

2

TXD-

3

RXD+

6

RXD-


Figure A-2: Front View of Ethernet Connector


A.1.2 Management Interface

The management port uses an RJ-45 connector.

Management Port Pinouts

The connector pinouts for the management port are shown in the following table.


Table A-2: Management Connector Pinouts
Pin Signal

4

Ground

5

RX

6

TX


Figure A-3: Front View of Management Connector


A.1.3 SDSL Port Interface

The symmetric digital subscriber line (SDSL) port uses an RJ-11 connector. (see Figure A-4.) Table A-3 shows the connector pinouts for the SDSL connector.

SDSL Connector Pinouts


Table A-3: SDSL Connector Pinouts
Pin Signal

3

Ring

4

Tip


Figure A-4:
Front View of SDSL Connector



hometocprevnextglossaryfeedbacksearchhelp