This chapter contains information and procedures for data links in the network. A data link can link two NEs, or it can link an NE to an external device such as a router.

This chapter contains the following sections:

Link Types

EMS offers the following types of inter node links:

Nondata Link

A nondata link identifies an established (nailed-up) connection between the local and remote node. A nondata link does not allow provisioning of a remote node, but it can be used to carry traffic and cross connects between the two nodes.

Inter Node Data Link

An inter node data link (INDL) allows the provisioning of a remote node over an established connection to the local node. There are two types of INDLs:

The remaining, non-management bandwidth is available for cross connects between nodes.

IP over Frame Relay

This link is used to carry IP traffic from the Cisco IAD1101 through a Frame Relay cloud. The link must be terminated on a router with a Frame Relay interface.


Note   You must provision the interface (line) for Frame Relay before creating an IP over Frame Relay data link. See "Frame Relay," for details about line provisioning.

IP over PPP

This link uses point-to-point protocol (PPP) to carry IP traffic from the Cisco IAD1101 through the Cisco WAN, terminated on a router.

IP Data Link Procedure


Note   If you are creating an inter node data link (INDL) or a nondata link between two NEs, Cisco Systems recommends that you use the visual link procedure. Go to the "Inter Node Data Link Procedure" section on page 8-9 for procedures.

The menu-based link procedure can be used to provision all types of inter node links. This is the only procedure that allows the creation of IP links (IP over Frame Relay and IP over PPP). The following example creates an IP link between a router and a Cisco IAD1101. (See Figure 8-1.) In this example, the router is the local node, and the Cisco IAD1101 is the remote node.


Figure 8-1: Inter Node Link between Cisco IAD1101 and Router


Before an inter node link can be provisioned, you must have an operational physical link between the two nodes. Both ends of the link must be in service and correctly provisioned before you can create an inter node link.

Perform the following procedures to provision an inter node link:

Provisioning the Local Node

The local node must be provisioned with a link to the remote node.

Provisioning the Remote Node

You must perform the following procedures to provision the remote node with an inter node link:

Provisioning a Fractional T1 (Frame Relay and PPP Links)

If you are creating an inter node link over Frame Relay or PPP, you must identify the group of DS0 channels to be used for the inter node link. EMS manages user-defined groups of DS0 channels with fractional T1 provisioning.

To provision a fractional T1, perform the following steps starting in node view:


Step 1   Right-click a T1 line, and click Create Fractional T1 from the popup menu. EMS launches the fractional T1 provisioning window. (See Figure 8-2.)


Figure 8-2: Fractional T1 Provisioning Window


Step 2   EMS displays a list of previously-provisioned fractional T1s in the Fractional T1 List. If you are creating a new fractional T1, you cannot use DS0 channels that are already part of another fractional T1.

Step 3   In the DS0s field, select the First and Last DS0 to define the range of DS0 channels for the fractional T1.

Step 4   Click Add to provision the fractional T1. EMS adds the fractional T1 to the list and assigns it an index.

Step 5   To provision additional fractional T1s, go to Step 3 and repeat this procedure.


Deleting a Fractional T1

To delete a fractional T1, highlight the fractional T1 in the list and click Delete. EMS removes the fractional T1 from the list.

Creating a Link to the Local Node

To create a link to the local node, perform the following steps starting in the NE provisioning window of the remote node:


Step 1   Click Node ID Configuration in the function bar. (See Figure 8-3.) EMS displays a list of all known nodes in the network.


Figure 8-3: Node ID Configuration


Step 2   Look for the IP address of the local node in the Node ID list. If the local node is not listed, perform the following steps to add the node:

Step 3   Click IP & Inter Node Link Configuration in the function bar. (See Figure 8-4.) EMS launches the inter node link provision window.


Figure 8-4: Provision Data Link


Step 4   Select the Local Interface type, card number, and line number.

Step 5   Select the Link Type:

Step 6   For a PPP link, select the Fractional T1 to carry the link.

Step 7   In the Remote Node ID field, enter the node ID of the remote node.

Step 8   For a Frame Relay link, click the DLCI in the DLCI List that will carry the INDL.

Step 9   Click Add to provision the link.

Step 10   To display information and statistics for the link, click the entry in the Link List.


Creating a Default Route to the Local Node

You must create a default route from the remote node to the local node.


Note   If you are creating a nondata link, you do not need to create a default route. Go to "Verifying the Link" on page 8-8 to ensure that the nondata link is operational.

Perform the following steps to provision the remote node with a default route:


Step 1   From the node view of the remote node, double-click the node nameplate. EMS launches the NE provision window.

Step 2   From the function bar on the left, click on the IP & Datalink Route Configuration button. EMS launches the data link route configuration window. (See Figure 8-5.)


Figure 8-5: Data Link Route Configuration Window


Step 3   Set the following parameters in the data link route configuration window:

Step 4   Click Add to provision the default route to the routing table.


In addition to the default route, you can configure additional routes as needed.
See
"IP Services," for more information about assigning routes.

Verifying the Link

To verify an IP data link, perform the following steps starting in the NE provisioning window:


Step 1   Select Ping Node from the function bar. EMS displays the ping node window. (See Figure 8-6.)


Figure 8-6: Ping Node Window


Step 2   Set the following parameters:

Step 3   Click Ping to ping the node. EMS displays results of the attempted ping in the Results list.

Step 4   A result of Success indicates that the IP data link is correctly provisioned.


Inter Node Data Link Procedure

The visual link procedure is recommended for connecting two NEs with the following link types:


Note   IP data links (IP over Frame Relay or IP over PPP) cannot be provisioned using this procedure. (See the sections "IP over Frame Relay" and "IP over PPP" on page 8-2.)

Figure 8-7 displays a common inter node link between two NEs. In this example, the Cisco 6732 is the local node, and the Cisco 6705 is the remote node. An INDL allows provisioning of the remote node from the local node network.


Figure 8-7: Inter Node Link between NEs


Each node must be provisioned with a separate "half link" before the inter node link can be used. The following procedures require local access to both nodes with the EMS workstation.

To create an inter node link, complete the following procedures:

Provisioning the Local Node

You must perform the following procedures to provision the remote node with an inter node link:

Setting the Default Gateway on the EMS Workstation

If you are creating an INDL, you must configure the EMS workstation to use the local node as the default gateway.


Note   You do not need to configure your EMS workstation for a nondata link. This procedure is only required for remote management and provisioning.

Use the TCP/IP configuration utility on your EMS workstation to set the Default Gateway to the same IP address as the local node. Figure 8-8 shows the TCP/IP configuration window for Windows NT. For the complete TCP/IP configuration procedure, see the "Configuring TCP/IP on the EMS Workstation" section, or contact your network administrator.


Figure 8-8: Windows NT—TCP/IP Properties


Creating a Visual Link

To create a half link from the local node to the remote node, complete the following steps starting in Cisco 6700 NetView:


Step 1   Connect the EMS workstation to the local node (Cisco 6732).

Step 2   Launch EMS on the workstation.

Step 3   In EMS NetView, make sure that both the local and remote nodes have been created. (See Figure 8-9.)


Figure 8-9: Cisco 6700 NetView


Step 4   Click and drag a line from the local node (Cisco 6732) to the remote node (Cisco 6705).
(See
Figure 8-10.)


Figure 8-10: Draw Line to Remote Node


Step 5   This creates a visual link between the two nodes. (See Figure 8-11.)


Figure 8-11: Visual Link


Step 6   From the menu bar, select File > Save to save the visual link.


Creating a Link to the Remote Node

To create a link to a remote node, complete the following steps:


Step 1   Click on the InterNode Provision button (located in the upper right corner of the Cisco 6700 NetView window). EMS launches the inter node provisioning window. (See Figure 8-12.)


Figure 8-12: Inter Node Provisioning Window


Step 2   Double-click the line between the two nodes. EMS launches the inter node link display.
(See
Figure 8-13.)


Figure 8-13: Inter-Node Link Display



Note   The local node (Cisco 6732), on the left side of the display, shows the installed cards that can be used to create an inter node link. The remote node (Cisco 6705), shown as a gray box on the right side of the display, does not display any card information.

Step 3   Select a line from the local node display that will be provisioned with the half link.

Step 4   Click and drag a visual link from the line on the local node to the remote node. (See Figure 8-14.)


Figure 8-14: Draw Line to Remote Node


Step 5   After creating the visual link, EMS launches the inter node link provision window. (See Figure 8-15.)


Figure 8-15: Inter Node Provision Window


Step 6   In the inter node link provision window, set the following parameters:


Note   To create a nondata link (used only for cross connects), set the Data Link field to None.

Step 7   Click Create (at the bottom of the window). EMS changes the Create button to Refresh.
(See
Figure 8-16.)


Figure 8-16: Local Half LInk Created


Step 8   Click Exit to close the inter node link provision window. EMS returns to the inter node link display. (See Figure 8-17.)


Figure 8-17: Inter Node Link Display with Local Half Link


The newly created half link is shown as a blue line connecting the local node and remote node.

Step 9   Click Back to Network Map (at the top of the window) to return to Cisco 6700 NetView.


Provisioning the Remote Node

You must perform the following procedures to provision the remote node with an inter node link:

Creating a Link to the Local Node

After creating a link on the local node, a similar link must created on the remote node—in this example, the Cisco 6705.


Step 1   Connect the EMS workstation to the remote node (Cisco 6705).

Step 2   Click on the Internode Provision button (located in the upper right corner of the Cisco 6700 NetView window). EMS launches the inter node provisioning window. (See Figure 8-18.)


Figure 8-18: Inter-Node Provisioning Window


Step 3   Double-click the line between the two nodes. EMS launches the inter node link display. (See Figure 8-19.)


Figure 8-19: Inter Node Link Display



Note   In the inter node link display, the remote node (Cisco 6705) is at the left side of the display. The local node (Cisco 6732), shown as a gray box, is at the right side of the display.

Step 4   Select the line from the remote node display to be provisioned with the half link.


Note   The line selected on the remote node must be the same line used in the
"Creating a Visual Link" section.

Step 5   Click and drag a visual link from the local line to the remote node. (See Figure 8-20.)


Figure 8-20: Draw Line to Remote Node


Step 6   After creating the visual link, EMS launches the inter node link provision window. (See Figure 8-21.)


Figure 8-21: Inter Node Link Provision Window


Step 7   In the inter node link provision window, set the following parameters:

Step 8   Click Create (at the bottom of the window). EMS changes the Create button to Refresh. (See Figure 8-22.)


Figure 8-22: Remote Half LInk Created


Step 9   Click Exit to close the inter node link provision window. EMS returns to the inter node link display. (See Figure 8-23.)


Figure 8-23: Inter Node Link Display with Local Half Link


The newly-created half link is shown as a blue line connecting the remote node and local node.

Step 10   Click Back to Network Map (at the top of the window) to return to the Cisco 6700 NetView. (See Figure 8-24.)


Figure 8-24: Cisco 6700 NetView with Visual Link



If you are creating an INDL, proceed to the next section to configure the default data-link route.

Creating a Default Route to the Local Node

To allow remote management and provisioning, you must create a default route from the remote node to the local node.


Note   If you are creating a nondata link, you do not need to create a default route. Go to "Verifying the Link" on page 8-8 to ensure that the nondata link is operational.

Perform the following steps to provision the remote node with a default route:


Step 1   Open the remote node (Cisco 6705) by double-clicking the remote node icon in Cisco 6700 NetView. EMS launches the node view of the remote node.

Step 2   Double-click the node nameplate. EMS launches the NE provision window.

Step 3   From the function bar on the left, click on the Datalink Route Configuration button. This brings up the data link route configuration window. (See Figure 8-25.)


Figure 8-25: IP & Data Link Route Configuration Window


Step 4   Set the following parameters in the data-link route configuration window:

Click Add when you are finished.

Step 5   Click the Exit button (on the function bar) to return to the node view.

Step 6   Select File > Exit to return to Cisco 6700 NetView.


Verifying the Link

To verify that an INDL has been successfully created, connect a EMS workstation to the local node (Cisco 6732). Open EMS NetView and double-click on the remote node (Cisco 6705). The remote node should open, displaying the node view. This means EMS can use the INDL to access the remote node.