This chapter describes ATM provisioning procedures and includes the following sections:
You can provision ATM virtual paths (VPs) and virtual channels (VCs) on the NE for use with internal and external ATM connections.
ATM can be provisioned on the following line cards:
To provision a line for ATM, complete the following steps starting in node view:

Step 2 Set the following fields for your ATM application:
Step 3 Click Apply to provision the line.
Step 4 Repeat this procedure to provision other lines on the line card.
Each line must be provisioned with at least one virtual path (VP) and one virtual channel (VC) before ATM traffic can be accommodated.
To assign VPs and VCs, complete the following steps starting from node view:

Step 2 The following ATM parameters should be set according to your ATM application:
Step 3 Click the VP/VC Assignment tab. EMS launches ATM Provisioning Window view that is used to assign VP/VCs. (See Figure 13-3.)

Step 4 Set the following ATM parameters:
Step 5 Click Create VP to provision the VPs. The newly-created VPs appear in the VP/VC List at the right side of the window.
Step 6 Click Create VC to provision the VCs. The newly-created VPs and VCs appear in the VP/VC List.
To delete VPs and VCs provisioned on a line, complete the following steps starting in node view:
Step 2 Click the VP/VC Modify and Delete tab. EMS displays a list of VPs and VCs provisioned on the line. (See Figure 13-4.)

Step 3 In the VP/VC List at the right side of the window, highlight the VPs and VCs to be deleted.
Step 4 Click Delete. EMS removes the highlighted VPs and VCs from the list.
After a line had been provisioned with a VP and VC, you can create an ATM cross connect to another line in the NE chassis.
To create an ATM cross connect, complete the following steps starting in node view:

Step 2 Highlight the VP/VC to be cross connected. EMS displays the VP/VC number in the Selected VPI and Selected VCI windows at the top of the list. (See Figure 13-6.)
Step 3 Click the Selected VCI text box, and drag the cursor to the desired facility.

Step 4 After the visual cross connect is drawn, EMS launches the ATM Cross Connect Provisioning window. (See Figure 13-7.) The VP/VC list on the left shows all VP/VCs for the source (originating) line, and the VP/VC list on the right shows VP/VCs for the destination line.

Step 5 Highlight the source VP/VC to be cross connected in the left VP/VC List.
Step 6 Highlight the destination VP/VC in the right VP/VC List. You must select one VP/VC on each line.
Step 7 Click Create to provision the ATM cross connection. EMS confirms the cross connect creation by displaying the letter "y" in the "CC" column, next to the connected VP/VCs. (See Figure 13-8.)

To delete ATM cross connects, perform the following steps starting in node view:

Step 2 In the VP/VC List, highlight the VP/VCs to be deleted.
Step 3 Click Delete. EMS removes the deleted cross connects from the VP/VC list display.
To close the ATM cross connect display, right-click on the VPI/VCI list in node view, and select End ATM Cross Connect Display from the popup menu. EMS closes the cross connect display.
To display ATM lists showing VP/VC assignments and ATM cross connects, perform the following steps starting in node view:

Step 2 Select ATM Cross Connect List from the function bar. EMS launches the ATM cross connect list. (See Figure 13-11.)

Step 3 Click Exit to return to node view.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Sep 25 17:05:34 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.