Table A-1 lists specifications for the Cisco 6400 universal access concentrator (UAC).
| Description | Specifications |
|---|---|
5 Gbps1 shared memory, nonblocking switch fabric | |
Software images | Default image |
21.75 in. x 17.5 in. x 12.0 in. (55.2 cm x 44.4 cm x 30.4 cm) standard 19-in. rack mount | |
Chassis minimum configuration (1 NSP, 1 PEM): 80 lb (37 kg) | |
Input power requirement | 1200W maximum (PEM-PWR-DC) (DC version) |
1200W maximum, 900W typical with maximum configuration | |
1200W (3768 Btu2/hr) (DC version) | |
DC input voltage range | -40.5 to -72 VDC (rated -48/-60 VDC) |
Maximum power budget: 20A @ -48 VDC | |
AC input voltage range | 90 to 255 VAC (rated 100 to 240 VAC using AC PEM) (See Cisco 6400 UAC Hardware Installation and Maintenance Guide, Appendix D for AC power shelf ratings) |
15A @ 100 VAC, 7A @ 240 VAC, using AC PEM (See Cisco 6400 UAC Hardware Installation and Maintenance Guide, Appendix D for AC power shelf ratings) | |
140 cfm3 through the system blower module 200 cfm through the system blower module when the exhaust temperature exceeds 40ºC | |
25 to 104ºF (-4 to 40ºC) Short-term operating temperature is limited to 131ºF (55ºC) in compliance with | |
Nonoperating temperature range | -40 to 167ºF (-40 to 75ºC) |
5 to 95%, noncondensing | |
-200 to 10,000 ft (-61 to 3048 m) | |
Loop timing, network timing derived from any NLC interface, Stratum 4 accuracy when internally timed. NSP-S3B also allows network timing from CO BITS, Stratum 3 accuracy when internally timed. | |
Node switch processor (NSP) | 64 MB DRAM, 8 MB Flash memory, 20 MB FlashDisk card (C6400-NSP-1) |
Node route processor (NRP) | 64 MB DRAM, 8 MB Flash memory (C6400-NRP-1) |
Full-height node line card (NLC) carrier module | Carrier module for 2 half-height NLCs with covers for empty slots installed (C6400-CARRIER) |
OC-3/STM-1 NLC | NLC with 2 SONET STS-3c/SDH STM-1 single-mode intermediate reach fiber ports, |
Fiber-optic power levels: OC-3 single-mode intermediate reach Output center wavelength |
|
DS3 NLC | NLC with 2 coaxial cable connections with BNC connectors (NLC-2DS3-BNC) Maximum station-to-station cabling distance is 450 ft (137 m) |
OC-12/STM-4 NLC | NLC with 1 SONET STS-12c/SDH STM-4 single-mode intermediate reach fiber ports, SC connector (NLC-1OC12-SM) |
Fiber-optic power levels: OC-12 single-mode intermediate reach Output center wavelength |
|
NSP interface ports | RJ-45 IEEE 802.3 Ethernet 10BaseT |
ATM connections | 32,000 point-to-point, 2048 point-to-multipoint (maximum) |
Network management | Port TX and RX LEDs, switch and common equipment status LEDs |
Mean time between failures | 17 years per RIN |
10BaseT Ethernet---Category 3-5 UTP: 328 ft (100 m) | |
Safety: Emission: Immunity: |
| 1Gbps = gigabits per second 2Btu = British thermal units 3cfm = cubic feet per minute 4nm = nanometers 5 dBm = decibels referenced to 1 milliwatt |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Nov 22 18:31:19 PST 1999
Copyright 1989-1999©Cisco Systems Inc.