Product Numbers: MC-SCI-V5.1= and MC-SCI-V5.1A=
This configuration note describes the maintenance upgrade procedures for the serial port communications interface (SCI) cards to Microcode Version 5.1. To complete the upgrade, you will replace twelve integrated circuit components. The new components are shipped as part of the SCI Version 5.1 upgrade kit, which you will use to upgrade your system software version. This upgrade is for SCI cards currently at Revision 2.
Microcode Version 5.1 supportsonly three serial ports, but each of the ports can be configured for either full- or half-duplex operation. (Half-duplex operation requires the V2 NRZI applique, which is identified by the letters "NRZI/H" on the label on the outside of the applique plate.)
Electrostatic discharge damage (ESD) occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures. ESD can impair electronic circuitry and equipment. Always follow ESD prevention procedures when removing and replacing cards. Following are steps for handling printed circuit cards:
Step 1 Slip on an ESD-preventive wrist strap, ensuring that it makes good skin contact.
Step 2 Connect the strap to an unpainted chassis frame surface or another proper grounding point or surface to safely channel unwanted ESD voltages to ground.
Step 3 Use the ejectors to remove the card. Handle the card by its sides. Place the card on an antistatic surface or in a static shielding bag. To prevent further damage to the card by ESD voltages, defective cards must remain in the static shielding bag when returned for repair or replacement.
Step 4 Handling the new card by its edges only, insert it into the chassis. Avoid contact between the card and clothing. The wrist strap only protects the card from ESD voltages on the body; ESD voltages on clothing can still damage the card.
![]() | Caution Use an ohmmeter to check the ESD-preventive wrist strap to ensure that the resistor is providing proper ESD protection. For safety, the measurement should be in the range 1 to 10 mega ohms. |
Verify that your current SCI card is marked Rev. /2. Then use the EXEC command show controller mci to confirm the current microcode version. The first line displayed on the screen contains the controller type and the microcode version. Verify that it displays the following:
MCI X, controller type 2.0, microcode version 1.3 (or 5.0)
Verify that the microcode version shown is correct for your upgrade kit. For upgrade kit
MC-SCI-V5.1=, the microcode should be version 1.0. For upgrade kit MC-SCI-V5.1A=, the microcode should be Version 1.1 or later. If you have the incorrect upgrade kit, contact a service representative.
![]() | Caution To prevent damage to the components from electrostatic discharge, observe proper ESD protection procedures when handling cards and their components. |

Follow this procedure to upgrade the SCI card. Before beginning, refer to Figure 1 and locate the components you will replace. The labels of the sockets and the part numbers of both the new (replacement) components are listed in Table 1. Note that some components can be supplied in one of several part numbers.
Step 1 Ensure that the power cord is unplugged from the wall and that you have taken proper precautions to prevent ESD damage to the card.
Step 2 With a chip extractor, remove the components from the locations listed in Table 1. If a chip extractor is not available, you can remove the components by gently lifting each from its socket using the tip of a flat-bladed screwdriver. (If you are upgrading from Microcode Version 1.1 or later, you will not replace the last five components listed in Table 1.)
Step 3 Replace the old components with the appropriate new components listed in Table 1. Position the new component in the socket using the same orientation as the old one. Set the notch on the side of each component in the same direction as the notches on the other components.
Step 4 Be careful not to bend any of the legs while inserting the component. If this happens, use needle-nose pliers to straighten the legs.
| Socket Location | Old Component Numbers | New Component Numbers1 |
|---|---|---|
| U607 | 17-1624-01 U607 | 17-1624-02 U607 |
| U504 | 17-1623-01 U504 | 17-1623-02 U504 |
| U505 | 17-1622-01 U505 | 17-1622-02 U505 |
| U506 | 17-1619-01 U506 | 17-1619-02 U506 |
| U404 | 17-1618-01 U404 | 17-1618-02 U404 |
| U405 | 17-1614-01 U405 | 17-1614-02 U405 |
| U406 | 17-1613-01 U406 | 17-1613-02 U406 |
| U304 | 17-1621-01 U304 | 17-1621-02 U304 |
| U305 | 17-1620-01 U305 | 17-1620-02 U305 |
| U306 | 17-1617-01 U306 | 17-1617-02 U306 |
| U204 | 17-1616-01 U204 | 17-1616-02 U204 |
| U205 | 17-1615-01 U205 | 17-1615-02 U205 |
| U2132 | 17/0675-01 U213 or 17/0675B-01 U213 or 13/107B-01 U213 | 17/0675-01 U213 or 17/0675B-01 U213 or 13/107B-01 U213 |
| U7082 | R68561AP-01 U708 | R68561AP-01 U708 |
| U7092 | R68561AP-01 U709 | R68561AP-01 U709 |
| U9082 | R68561AP-01 U908 | R68561AP-01 U908 |
| U9092 | R68561AP-01 U909 | R68561AP-01 U909 |