Attaching the PA-F Port Adapter Cables

Attaching the PA-F Port Adapter Cables

To continue your PA-F-SM and PA-F-MM port adapter installation, you must install the port adapter cables. The instructions that follow apply to all supported platforms. This chapter contains the following sections:

Connecting an FDDI Cable

Both single-mode and multimode dual attachment connections are available. Fiber-optic cable connects directly to the FDDI ports. Single-mode transmission uses simplex or duplex SC-type transmit and receive cables. Multimode transmission uses MIC cables.

Warning
Invisible laser radiation may be emitted from the aperture ports of the single-mode FDDI products when no fiber cable is connected. Avoid exposure and do not stare into open apertures.

Connect cables for single-mode transmission dual attachment stations as shown in Figure 6-1.


Figure 6-1: Single-Mode Dual Attachment Connection with Duplex and Simplex SC-Type Cables and Optical Bypass Control Cable



Note Use four single-mode SC-simplex cables or two SC-duplex cables for a dual attachment connection.

Connect cables for multimode transmission on dual attachment stations as shown in Figure 6-2.


Figure 6-2: Multimode Dual Attachment Connection with MIC Cables and Optical Bypass Control Cable


Attaching an Optical Bypass Switch

This section describes the procedures for attaching an optical bypass switch to the half-duplex FDDI port adapters. (Use these procedures for FDDI port adapters installed on a VIP2, Catalyst RSM/VIP2, or in a Cisco 7200 series router [including a Cisco 7206 as a router shelf in a Cisco AS5800 Universal Access Server].)

An optical bypass switch is a device installed between the ring and the station that provides additional fault tolerance to the network. If an FDDI port adapter that is connected to a bypass switch fails or shuts down, the bypass switch activates automatically and allows the light signal to pass directly through it, bypassing the port adapter completely.

Following are general instructions for connecting an optical bypass switch to the FDDI port adapter; however, your particular bypass switch may require a different connection scheme. Use these steps and the illustrations in Figure 6-3 and Figure 6-4 as general guidelines, but for specific connection requirements, refer to the instructions provided by the manufacturer of the optical bypass switch.

    1. Connect the bypass switch to the ring. Unless the documentation that accompanies the bypass switch instructs otherwise, observe the same guidelines for connecting the A/B ports on the bypass switch that you would to connect the ring directly to the FDDI ports. Use the receive label on the cable connectors as a key and connect the multimode or single-mode cables to the network (ring) side of the bypass switch as follows:

    2. Connect the bypass switch to the port adapter. Unless the documentation that accompanies the bypass switch instructs otherwise, consider the bypass an extension of the FDDI ports and connect A to A and B to B. The network cables are already connected to the bypass switch following the standard B-to-A/A-to-B scheme.

    3. Connect the bypass switch control cable. If the control cable on your optical bypass switch uses a mini-DIN connector, connect the cable directly to the female mini-DIN optical bypass port on the FDDI port adapter. If the switch uses a standard DIN connector, use the optical bypass adapter cable (Product Number CAB-FMDD=) supplied with each FDDI port adapter. Connect the DIN end of the adapter cable to the DIN on the control cable, and connect the mini-DIN end of the adapter cable to the mini-DIN optical bypass port on the FDDI port adapter.

A port for connecting an optical bypass switch is provided on the single-mode port adapter (PA-F-SM, shown in Figure 6-3) and the multimode port adapter (PA-F-MM, shown in Figure 6-4).


Figure 6-3: Optical Bypass Switch Connection---PA-F-SM



Note Up to 160 milliamperes of current can be supplied to the optical bypass switch.

Figure 6-4:
Optical Bypass Switch Connection---PA-F-MM