Product Numbers: CT3IP-20= and CT3IP-40(=)
This configuration note contains instructions for installing the Channelized T3 Interface Processor (CT3IP) in the Cisco 7000 series routers and the Cisco 7500 series routers. For the CT3IP to operate properly in the Cisco 7000 series routers, the 7000 Series Route Switch Processor (RSP7000) and 7000 Series Chassis Interface (RSP7000CI) must be installed.
This configuration note also contains basic configuration steps and examples. For complete descriptions of additional interface subcommands and configuration options available for your router, refer to the appropriate configuration publications listed in the section "If You Need More Information" on page 2. (Also refer to the section "Software and Hardware Prerequisites" on page 8.)
Sections in this document include the following:
The Cisco IOS software running your router contains extensive features and functionality. For information on Cisco IOS software and for general installation and maintenance information for your router, use the following resources:
The CT3IP, shown in Figure 1 and Figure 2, is a fixed-configuration interface processor based on the second-generation Versatile Interface Processor (VIP2).


The CT3IP has the following features and physical characteristics:
T3 traditionally involves multiplexing 28 T1 lines on to a single higher-speed line (T3 line). Each of the 28 T1 lines in the T3 are asynchronous to one other. A T1 line accommodates 24 64-kilobit-per-second (Kbps) DS0 channels. While the DS0s are byte multiplexed to each T1, the T1 lines are bit multiplexed to the T3 in a framing format called M23 or C-BIT parity.
M13 multiplexing is done in two steps. First, four T1 lines are bit multiplexed together to form a DS2 line using M12 multiplexing. These seven DS2 lines are then bit multiplexed together to form the DS3/T3 using M23 multiplexing.
M13 multiplexing uses bit stuffing to bring each asynchronous DS1/DS2 up to a common data rate for transmission. C-BIT Parity multiplexing forces the seven DS2s to be synchronous to each other at a rate that causes 100-percent pulse stuffing in the M23 frame. This allows the "stuff" indicator bits in the M23 frame to be used as a maintenance link between the end points.
The CT3IP functions very much like an M13 multiplexer with each T1 line terminating with or originating into or from an HDLC controller on the port adapter. The CT3IP offers 28 individual T1 channels (bundled in the T3) for serial transmission of data. Each of the T1 channels uses a portion of the T1 bandwidth (fractional T1) or the entire T1 bandwidth for data transmission. Usable bandwidths for each T1 are n x 56 Kbps or n x 64 Kbps, where n is a number from 1 to 24. The unused portion of the T1 bandwidth, when not running at full T1 speeds, cannot be used and is filled with idle channel data.
The T3 section of the CT3IP supports the maintenance data link channel (C-BIT parity) as well as payload and network loopbacks. The T1 section of the CT3IP supports Facility Data Link (FDL) in extended super frame (ESF) framing, as well as network and payload loopbacks. Bit error rate testing (BERT) is supported on each of the T1 links. The BERT testing is only done over a framed T1 signal. The M13 multiplexer performs M12 multiplexing on 4 four T1 signals. (There are seven M12 multiplexers available on board.) The seven M12 multiplexers pass their data to the M23 multiplexer, which takes the seven tributaries and formats them into a DS3 stream. This transmit stream is passed on to the T3 line interface unit (LIU) for transmission out of the BNC connector into a 75-ohm coaxial line.
The first three T1 channels of the channelized T3 can be broken out, under software control, to the three DB-15 connectors on the front of the CT3IP for further demultiplexing via a MultiChannel Interface Processor (MIP). This allows three (the first three) of the 28 T1 streams in the channelized T3 to be a channelized T1 stream.
The broken-out T1(s) are sent to a T1 LIU, which transmits the T1(s) at the DSX-1 level. (DSX-1 refers to the cross connection point for DS-1 signals.) When operating in this mode, these ports are not CSU ports. They do not detect loop codes, provide ones-density requirements, or respond to any FDL messages. The receiving end (MIP) must provide the CSU functionality. Under software control, each external T1 port can be disabled or enabled.
The CT3IP does not support the aggregation of multiple T1s (called inverse muxing or bonding) for higher bandwidth data rates. CT3IP supports Cisco HDLC, Frame Relay, PPP, and SMDS Data Exchange Interface (DXI) encapsulations over each T1 link. For SMDS only, DXI is sent on the T1 line so it needs to connect to an SMDS switch that has direct DXI input.
There is a special DB-15 connector on the CT3IP, labeled TEST. This test connector allows you to break out any T1 of the T3 stream, under software control. This functionality allows you to break out any of the 28 T1s within the T3 stream for testing (for example, 24-hour BERT testing as is commonly done by telephone companies before a line is brought into service), or for further channelization via a MIP card.
The CT3IP microcode is a software image that provides card-specific software instructions. Cisco 7000 series and Cisco 7500 series routers support downloadable microcode, which enables you to upgrade microcode versions by downloading new microcode images, storing them in Flash memory, and instructing the system to load an image from Flash memory.
You can store multiple images for an interface type and instruct the system to load any one of them with a configuration command. All interfaces of the same type (all CT3IPs, and so on) will load the same microcode image from a single image stored in Flash memory. The Flash-based boot read-only memory (ROM) device on the CT3IP contains a microcode boot image that instructs the system to load the full microcode image as described by the configuration.
Although multiple microcode versions for a specific interface type can be stored concurrently in Flash memory, only one image can load at startup. The show controller cbus command displays the currently loaded and running microcode version for each interface processor. The show microcode command displays the microcode images bundled with the Cisco IOS software.
An example follows:
Router# sh microcode
Microcode bundled in system
Card Microcode Target Hardware Description
Type Version Version
---- --------- --------------- -----------
(additional display text omitted)
VIP2 21.40 2.x VIP2 version 21.40
(additional display text omitted from this example)
In the preceding example, the CT3IP's microcode is listed as VIP2 because the CT3 port adapter is attached to a VIP2 motherboard and uses its microcode image. For a complete description of microcode and downloading procedures, refer to the section "Upgrading Microcode" on page 41. The example does not necessarily show an actual version of CT3IP microcode.
For T1, two standard serial cables, null-modem and straight-through, are available from Cisco Systems and other vendors for use with the CT3IP. The CT3IP T1 interface cables are used to connect your router to external CSUs or a MIP card. The CT3IP T1 interface cables have two male 15-pin DB connectors at each end to connect the CT3IP's T1 interfaces.
Figure 3 shows the CT3IP interface cable, connectors, and pinouts. Table 1 lists the signal pinout for the straight-through cable. Table 2 lists the signal pinout for the null-modem cable.

| DB-15 Connector | DB-15 Connector | ||
|---|---|---|---|
| Pin | Signal1 | Pin | Signal |
| 1 | Tx tip | 1 | Tx tip |
| 3 | Rx tip | 3 | Rx tip |
| 9 | Tx ring | 9 | Tx ring |
| 11 | Rx ring | 11 | Rx ring |
| Case | Ground/shield | Case | Ground/shield |
| DB-15 Connector | DB-15 Connector | ||
|---|---|---|---|
| Pin | Signal1 | Pin | Signal |
| 1 | Tx tip | 3 | Rx tip |
| 3 | Rx tip | 1 | Tx tip |
| 9 | Tx ring | 11 | Rx ring |
| 11 | Rx ring | 9 | Tx ring |
| Case | Ground/shield | Case | Ground/shield |
The T3 line interface unit (LIU) is designed to meet the following specifications:
The T3 LIU is compliant for the above specifications for input jitter tolerance, pulse shape/amplitude (DSX3), line termination, and jitter. The LIU has a flat transfer function so jitter introduced by the LIU is insignificant.
The CT3IP T3 port is designed to receive and transmit at the DSX-3 level while driving and56 receiving from a 75-ohm coaxial cable (ATT 728A type coax). It connects directly to any equipment with DSX-3 level BNC connectors. The T3 front end is designed to meet the following specifications:
The T1 LIU is designed to meet the following specifications. (See also Table 3.)
The T1 LIU is designed to meet the preceding specifications for input jitter tolerance, pulse shape/amplitude (DSX1), line termination, and jitter. The LIU has a relatively flat transfer function so jitter introduced by the LIU is minimal.
The CT3IP T1 ports are designed to receive and transmit at the DSX-1 level while driving and receiving from a 100-ohm twisted-pair cable. It connects directly to any equipment with DSX-1 level input/output. The T1 front end is designed to meet the following specifications:
| T1 Channel No. | Data Rates |
|---|---|
| 1-20 | n x 64 Kbps up to full T1 (1.536 Mbps) |
| 21-28 | n x 56 Kbps up to full T1 (1.344 Mbps) or n x 64 Kbps up to full T1 (1.536 Mbps) |
Before you begin the installation, review the guidelines in this section to assure proper system operation, avoid injuring yourself, or damaging the equipment.
The CT3IP is compatible with any Cisco 7000 series or Cisco 7500 series router that is operating with Cisco IOS Release 11.1(8)CA or later; however, certain command and feature functionality is only available with Cisco IOS Release 11.1(9)CA1 or later, or Cisco IOS Release 11.2(7)P or later.
For the CT3IP to operate properly in the Cisco 7000 series routers, the 7000 Series Route Switch Processor (RSP7000) and 7000 Series Chassis Interface (RSP7000CI) must be installed. The CT3IP will not operate properly in Cisco 7000 series routers with the Route Processor (RP) and Switch Processor (SP) (or Silicon Switch Processor [SSP]) installed.
The show version command displays the current hardware configuration of the router, including the system software version that is currently loaded and running. The show controller cbus command lists all electrical interfaces and includes the currently loaded and running microcode version for each.
If the displays indicate that the running system software is earlier than Cisco IOS Release 11.1(8)CA or later, check the contents of Flash memory to determine if the required images are available on your system. The show flash command displays a list of all files stored in Flash memory.
The show microcode command displays a list of all the microcode images currently bundled with the Cisco IOS software. If these displays indicate that the required system software and microcode are not available, contact a service representative for upgrade information. (Refer to the section "Upgrading Microcode," on page 41, for more information. For information on additional show commands, refer to the section "Command Descriptions and Examples" on page 28.)
This section lists safety guidelines you should follow when working with any equipment that connects to electrical power or telephone wiring.
Follow these basic guidelines when working with any electrical equipment:
Use the following guidelines when working with any equipment that is connected to telephone wiring or to other network cabling:
Electrostatic discharge (ESD) damage, which can occur when electronic cards or components are improperly handled, results in complete or intermittent failures. The CT3IP comprises a printed circuit board that is fixed in a metal carrier. Electromagnetic interference (EMI) shielding, connectors, and a handle are integral components of the carrier. Although the metal carrier helps to protect the board from ESD, use a preventive antistatic strap whenever handling the CT3IP. Handle the carriers by the handles and the carrier edges only; never touch the boards or connector pins.
Following are guidelines for preventing ESD damage:
Caution For safety, periodically check the resistance value of the antistatic strap. The measurement should be between 1 and 10 megohms.
You need the following tools and parts to install the CT3IP. If you need additional equipment, contact your service representative for ordering information.
This section describes mechanical functions of system components, emphasizes the importance of following correct procedures to avoid unnecessary board failures, and is for background only; specific procedures follow in the section "CT3IP Installation Procedures" on page 14.
You can remove and replace interface processors while the system is operating; you do not need to notify the software or reset the system power. This functionality enables you to add, remove, or replace interface processors with the system online, which provides a method that is seamless to end users on the network, maintains all routing information, and ensures session preservation.
After an interface processor is reinstalled, the system brings on line only interfaces that match the current configuration and were previously configured as up; all others require that you configure them with the configure command.
Caution The system can indicate a hardware failure if you do not follow proper procedures. Remove or insert only one interface processor at a time. Allow at least 15 seconds for the system to complete the preceding tasks before removing or inserting another interface processor. Disrupting the sequence before the system completes its verification can cause the system to interpret hardware failures.
All interface processors have ejector levers that allow you to firmly seat an interface processor in the interface processor slot. The function of the ejector levers is to align and seat the card connectors in the backplane. Failure to use the ejector levers and insert the interface processor properly can disrupt the order in which the pins make contact with the backplane.
It is also important to use the ejector levers when removing an interface processor to ensure that the board connector pins disconnect from the backplane in the logical sequence expected by the system. Any processor module that is only partially connected to the backplane can hang the bus. Detailed steps for correctly installing and removing the interface processor follow.
The processor modules slide into slots in the rear of the chassis and connect directly to the backplane. The backplane slots are keyed so that the processor modules can be installed only in the slots designated for them.
Figure 4 shows the ejector levers and captive installation screws on a typical interface processor. To remove an interface processor, loosen the captive screws and pull the ejector levers to the sides; then pull the module out using the handle. To insert an interface processor, reverse the process, making sure to firmly seat the interface processor in its connectors on the backplane. For detailed directions, follow the procedures in the section "CT3IP Installation Procedures" on page 14.
Caution Always use the ejector levers to remove or install the CT3IP. The ejectors help ensure that backplane connectors on the card are fully seated in, or fully ejected from, the backplane. Failure to use the ejector levers could result in a partial backplane connection, which can hang the system.
The captive installation screws on the ends (see Figure 4) of each faceplate, when tightened, provide EMI shielding and also help ensure proper seating in the backplane. After using the ejector levers to install a CT3IP, tighten the captive installation screws to prevent the CT3IP from becoming partially dislodged from the backplane. These screws must be tightened to meet EMI specifications.

The following sections describe the procedures for removing or installing the CT3IP. The OIR feature allows you to install and remove the CT3IP without turning off system power. Refer to the section "Guidelines for Interface Processor Removal and Installation," on page 11, for a complete description of OIR.
Caution To avoid erroneous failure messages, remove or insert only one interface processor at a time. Also, after inserting or removing an interface processor, allow at least 15 seconds before removing or inserting another interface processor so that the system can reinitialize and note the current configuration of all interfaces. For the initial release of the CT3IP, OIR for the CT3IP functions as described; however, if you install or remove other interface processors in a Cisco 7000 series or Cisco 7500 series router with a CT3IP installed, you might have to reset the chassis after OIR of that interface processor. To prevent system problems, we recommend you follow the OIR procedures.
You need not shut down the interface or the system power when removing a CT3IP or other interface processor.
If you have a Cisco 7507 or a Cisco 7513 with an RSP2 configured as the system slave, we strongly recommend that you use the following procedure to remove and replace an interface processor:
Step 1 Remove the slave RSP2.
Step 2 Wait 15 seconds.
Step 3 Remove and replace the interface processor using the procedures in this publication.
Step 4 Wait 15 seconds.
Step 5 Reinsert the slave RSP2.
If you are replacing a failed CT3IP, remove the existing board first, then replace the new CT3IP in the same slot. If you are replacing a currently installed interface processor with a CT3IP, remove the existing board first, then install the new CT3IP in the same slot.
Figure 5 shows proper handling of an interface processor during installation.

To remove the CT3IP, follow these steps:
Step 1 Disconnect the CT3IP interface cables from the CT3IP ports.
Step 2 Loosen the captive installation screws at the top and bottom of the CT3IP. (See Figure 4a.)
Caution Always use the ejector levers to remove or install the CT3IP. Failure to do so can cause erroneous system error messages, indicating a board failure.
Step 3 Place your thumbs on the upper and lower ejector levers and simultaneously push the top ejector lever up and the bottom ejector lever down (in the opposite direction from that shown in Figure 4c) to release the CT3IP from the backplane connector.
Step 4 Grasp the CT3IP handle with one hand and place your other hand under the carrier to guide the CT3IP out of the slot. (See Figure 4.) Avoid touching the board or any connector pins.
Step 5 Carefully pull the CT3IP straight out of the slot, keeping one hand under the carrier to guide it. (See Figure 4.) Keep the CT3IP parallel to the backplane.
Step 6 Place the removed CT3IP on an antistatic mat or foam pad, or place it in an antistatic bag if you will return it to the factory.
Step 7 If the interface processor slot is to remain empty, install an interface processor filler
(MAS-7000BLANK=) to keep dust out of the chassis and to maintain proper airflow through the interface processor compartment.
The CT3IP slides into any available interface processor slot and connects directly to the backplane. The backplane slots are keyed so that the CT3IP can be installed only in an interface processor slot. Interface processor fillers, which are blank interface processor carriers, occupy empty slots to maintain consistent air flow through the interface processor compartment. If you are installing a new CT3IP, you will have to first remove the interface processor filler from the available interface processor slot. Figure 4 shows the functional details of inserting an interface processor and using the ejector levers. Figure 5 shows proper handling of an interface processor during installation.
Caution Remove or insert only one interface processor at a time. Allow at least 15 seconds for the system to complete the preceding tasks before removing or inserting another interface processor. Disrupting the sequence before the system completes its verification can cause the system to interpret hardware failures.
Follow these steps to install the CT3IP:
Step 1 Ensure that a console terminal is connected to the RP (or RSP) Console port and that the console is turned on.
Step 2 Choose an available interface processor slot for the CT3IP and ensure that the CT3IP interface cable is of a sufficient length to connect the CT3IP with the CSU.
Step 3 Interface processors and interface processor fillers are secured with two captive installation screws. (See Figure 4a.) Use a flat-blade screwdriver to loosen the captive installation screws and remove the interface processor filler (or the existing CT3IP) from the slot. If you remove the CT3IP, immediately place it into an antistatic bag to prevent damage from electrostatic discharge.
Step 4 Hold the CT3IP handle with one hand, and place your other hand under the carrier to support the CT3IP (see Figure 4) and guide it into the slot. Avoid touching the card or any connector pins.
Caution To prevent ESD damage, handle interface processors by the handles and carrier edges only.
Step 5 Place the back of the CT3IP in the slot and align the notch on the bottom of the carrier with the groove in the slot. (See Figure 4a.)
Step 6 While keeping the CT3IP parallel to the backplane, carefully slide the CT3IP into the slot until the back of the faceplate makes contact with the ejector levers, then stop. (See Figure 4b.)
Caution Always use the ejector levers when installing or removing processor modules. A module that is partially seated in the backplane will cause the system to hang and subsequently crash.
Step 7 Using the thumb and forefinger of each hand to pinch each ejector lever, simultaneously push the top ejector lever down and the bottom ejector lever up until both are parallel to the faceplate. (See Figure 4c.)
Step 8 Tighten the captive screws on the top and bottom of the interface processor faceplate to prevent the interface processor from becoming partially dislodged from the backplane and ensure proper EMI shielding. (These screws must be tightened to meet EMI specifications.)
Caution Always tighten the captive installation screws on interface processors. These screws prevent accidental removal and provide proper grounding for the system.
This completes the CT3IP installation. Proceed to the following section to attach interface cables to the CT3IP.
Attach the CT3IP network interface cables between the CT3IP interface ports and the CSU. This includes up to four T1 cables and two DS1 BNC cables. (See Figure 6.) Proceed to the following section to check the cable connections.

The CT3IP has several status LEDs on its faceplate. (See Figure 7.)

Following are the functions of the CT3IP LEDs:
For additional functions of the status and alarm LEDS, refer to the section "Using Status and Alarm LED Indications" on page 37.
The individual 1, 2, 3, and test LEDS next to each T1 port indicate the following: This green LED will go on when the respective port is enabled. When the port is not enabled, the LED is off.
The remaining five LEDs, between the TEST and T3 ports, indicate the following:
Observe the LED states and the console displays as the router initializes. When the system has reinitialized all interfaces, the enabled LED on the CT3IP should go on.
The console screen will also display a message as the system discovers each interface during its reinitialization. After system initialization, the enabled LED goes on to indicate that the CT3IP is enabled for operation.
The following conditions must be met before the CT3IP is enabled:
If any of these conditions is not met, the enabled LED does not go on.
Verify that the CT3IP is connected correctly as follows:
Step 1 While the system reinitializes each interface, observe the console display messages and verify that the system discovers the CT3IP. The system should recognize the CT3IP's interfaces but leave them configured as down.
Step 2 When the reinitialization is complete, verify that the enabled LED on the CT3IP is on and remains on. If the LED does stay on, proceed to Step 5. If the enabled LED does not stay on, proceed to the next step.
Step 3 If the enabled LED on the CT3IP fails to go on, suspect the that the CT3IP board connector is not fully seated in the backplane. Loosen the captive installation screws, then firmly push the top ejector down while pushing the bottom ejector up until both are parallel to the CT3IP faceplate. Tighten the captive installation screws. After the system reinitializes the interfaces, the enabled LED on the CT3IP should go on. If the enabled LED goes on, proceed to Step 5. If the enabled LED does not go on, proceed to the next step.
Step 4 If the enabled LED still fails to go on, remove the CT3IP and try installing it in another available interface processor slot.
Step 5 Use the show interfaces or show controllers cbus command to verify the status of the CT3IP's interfaces. (If the interfaces are not configured, you must use the procedures in the section "Configuring the CT3IP," which are not available until you configure them.)
If an error message displays on the console terminal, refer to the appropriate reference publication for error message definitions. If you experience other problems that you are unable to solve, contact a service representative for assistance.
If you installed a new CT3IP or if you want to change the configuration of an existing controller, you must enter the Configuration mode. If you replaced the CT3IP that was previously configured, the system will recognize the new CT3IP and bring it up in the existing configuration.
After you verify that the new CT3IP is installed correctly, use the privileged-level configure command to configure the new CT3IP controller. Be prepared with the information you will need, such as the following:
For a complete summary of the configuration options available and more detailed instructions for configuring the CT3IP controller, refer to the appropriate configuration publications, which are listed in the section "If You Need More Information," on page 2.
Before you can use the configure command, you must enter the privileged level of the EXEC command interpreter with the enable command. The system will prompt you for a password if one has been set.
The system prompt for the privileged level ends with a pound sign (#) instead of an angle bracket (>). At the console terminal, enter the privileged level as follows:
Step 1 At the user-level EXEC prompt, enter the enable command. The EXEC prompts you for a privileged-level password as follows:
enable
Step 2 Enter the password (the password is case sensitive). For security purposes, the password is not displayed.
Step 3 When you enter the correct password, the system displays the privileged-mode system prompt (#) as follows:
Proceed to the following section to configure the CT3IP controller.
The interface numbering scheme for the CT3IP's T1 interfaces is in the form of slot/port-adapter/port:t1 channel: where slot refers to the chassis slot in which the CT3IP is installed, port-adapter is always 0 (because the CT3IP has only one dual-width port adapter); port refers to the physical port on the CT3IP and is always 0; and t1 channel is a number between 1 and 28. (Refer to the section "Configuring the CT3IP," on page 20, for more specific interface configuration information.)
Designate and turn on an external T1 port (one of the three DB-15 connectors labeled 1 through 3) using the t1 external channel command, where t1 channel is a number between 1 and 3.
Designate and turn on the T1 test port (the DB-15 connector labeled TEST) using the t1 test channel command, where t1 channel is a number between 1 and 28.
Following are examples of CT3IP interface port numbering and sample displays:
The following sample display shows the events logged by the system as the CT3IP was removed from slot 3; the system then reinitialized the remaining interface processors and marked as down the CT3IP when it is installed in slot 4. When the CT3IP was reinserted, the system marked the interfaces as down again because the CT3IP interfaces were not shut down before the CT3IP was removed.
Router# %OIR-6-REMCARD: Card removed from slot 3, interfaces disabled %LINK-5-CHANGED: Interfaces T3 3/0/0, changed to administratively down
When a new CT3IP is inserted, or when a CT3IP whose interfaces are shut down is moved to a new slot, the system recognizes the CT3IP controller, but leaves its interfaces in a shutdown state until you configure them and change the state to up with the configure command. If you move a CT3IP to a new slot and its interfaces were not shut down, the system recognizes them as not shut down when the CT3IP is installed in the new slot.
The following example display shows the events logged by the system as a new CT3IP is inserted in slot 4:
Router# %OIR-6-INSCARD: Card inserted in slot 4, interfaces administratively shut down %LINK-5-CHANGED: Interfaces T3 4/0/0, changed to administratively down Router#
The following steps describe basic configuration guidelines and configuration command examples for the T3 and then T1 interfaces. Press the Return key after each step.
Following are the steps to configure the T3 interface:
Step 1 At the privileged-mode prompt, enter Configuration mode and specify that the console terminal will be the source of the configuration subcommands as follows:
conf t
Enter configuration commands, one per line. End with CNTL/Z.
Step 2 Specify the controller to configure by entering the subcommand controller, followed by t1 or t3, and slot/port (interface processor slot number/interface port number). The example that follows is for the CT3IP in interface processor slot 3 for T3 channel 0:
cont t3 3/0/0
Step 3 At the prompt, specify the framing type using the framing [c-bit | m23 | auto-detect] command: set c-bit framing format, as follows:
framing c-bit
At the prompt, request the CT3IP to detect the framing type it is to receive from the far end, as follows:
framing auto-detect
Step 4 Specify the cable length using the cablelength feet command, where feet is expressed as a numeral from 0 to 450, with the default value of 224 feet. Issue the cablelength command as follows:
cablelength 200
Step 5 Specify the clock source for the controller using the clock source [internal | line] command, which determines which end of the circuit provides the clocking.
clock source line
Maintenance Data Link (MDL) messages (which are defined in the ANSI T1.107a-1990 specification) can be configured on the CT3IP.
To configure MDL messages, use the following controller configuration commands:
mdl {transmit {path | idle-signal | test-signal} | string {eic | lic | fic | unit | pfi | port | generator} string}where the command arguments are defined as follows:
Use the no form of this command to remove message. The default is that no MDL message is configured.
Following are examples of configuring MDL messages; enter controller Configuration mode first, as follows:
Router#conf tEnter configuration commands, one per line. End with CNTL/Z. Router(config)#cont t3 3/0/0Router(config-controll)#
Router(config-controll)#mdl string eicrouter A
Router(config-controll)#mdlstring lictest network
Router(config-controll)#mdlstring ficbuidling b
Router(config-controll)#mdl string unitabc
Router(config-controll)#mdlstring pfistring
Router(config-controll)#mdl string portstring
Router(config-controll)#mdl string generatorstring
Router(config-controll)# mdl transmit path
Router(config-controll)# mdl transmit idle-signal
Router(config-controll)# mdl transmit test-signal
Following are the guidelines for configuring the logical T1 interfaces using controller configuration commands. Examples follow:
Step 1 Specify the channel and timeslots to be mapped using the t1 t1 channel timeslots range [speed {56 | 64}] command.
Where T1 channels are 1-28, range supports contiguous timeslots as well as arbitrary timeslots, and a speed of 56 Kbps is only valid for T1 21-28 (default is 64 Kbps).
Examples follow:
Configure T1 0 for full T1 bandwidth, as follows:
t1 0 timeslots 1-24 speed 64
Configure the T1 20 to use timeslots 1 through 5 and timeslots 20 through 23 as follows:
t1 20 timeslots 1-5,20-23
Configure the T1 21 for 24 x 56 Kbps as follows:
t1 21 timeslot 1-24 speed 56
Step 2 Specify the T1 framing format using the t1 t1 channel framing [esf | sf] command. The default is the extended super frame (ESF) framing format, and T1 channel is 1-28.
Examples follow:
Set super frame (SF) framing format for T1 6 as follows:
t1 6 framing sf
Set ESF framing format for T1 18 as follows:
t1 18 framing esf
Step 3 Specify remote T1 line code using the t1 t1 channel linecode [ami | b8zs] command. The default is b8zs, and the T1 channel is 1-28.
An example follows:
t1 0 linecode ami
int s2/0/0:0
invert data
Step 4 Specify the T1 clock source using the t1 t1 channel clock source [internal | line] command, where the T1 channel is 1-28, and the default is network (line) clocking.
Examples follow:
Set internal clock source for T1 6 as follows:
t1 6 clock source internal
Set network clock source for T1 1 as follows:
t1 1 clock source line
To remove a T1 channel, use the no t1 t1 channel timeslots 1-24 command, where the T1 channel is 1-28. For example, remove the channel for T1 20 as follows:
Router(config-controll)# no t1 20 timeslots 1-24
The following controller configuration commands are valid only to the first three T1 channels (T1 0 through 2) when they are broken out to the external T1 port. Configure a T1 Interface as an external port using the t1 external t1 channel [linecode {b8zs | ami}] [cablelength feet] command, where external T1 channels are 1-3, and the cable length range is 0-655 feet. The default values are as follows: line code is B8ZS; cable length is 133 feet.
(Use the show controller t3 command to check the status of the external ports; refer to the example of this command on page 31 of the section "Command Descriptions and Examples.")
For example, configure T1 1 to be an external port as follows:
Router(config-controll)# t1 external 1 lincecode ami cablelength 300
To remove a T1 interface from an external port, use the no t1 external t1 channel command, where external T1 channels are 1-3.
For example, remove T1 1 from external port 1 as follows:
Router(config-controll)# no t1 external 1
The following controller configuration commands are valid only to the T1 test port. Configure the T1 test port using the t1 test t1 test channel [linecode {b8zs | ami}] [cablelength feet] command, where the T1 test channels are 1-28, and the cable length range is 0-655 feet. The default values are as follows: line code is B8ZS; cable length is 133 feet.
(Use the show controller t3 command to check the status of the test port; refer to the example of this command on page 31 of the section "Command Descriptions and Examples.")
For example, bring T1 20 to the test port as follows:
Router(config-controll)# t1 test 20 lincecode ami cablelength 300
To remove a T1 port from the test port, use the no t1 test t1 test channel command, where T1 test channels are 1-28.
For example, remove T1 20 from the test port as follows:
Router(config-controll)# no t1 test 20
Following are additional commands required to complete the CT3IP configuration:
Step 1 Assign an IP address and subnet mask to the interface with the ip address configuration subcommand as in the following example:
ip address 1.1.15.1 255.255.255.0
Step 2 Add any additional interface subcommands required to enable routing protocols and adjust the interface characteristics.
Step 3 After including all of the interface subcommands to complete the configuration, press Ctrl-Z (hold down the Control key while you press Z) to exit the configuration mode.
Step 4 Write the new configuration to memory as follows:
copy running-config startup-config
The system displays an OK message when the configuration is stored.
Step 5 Exit the privileged level and return to the user level by entering disable at the prompt as follows:
disable
Proceed to the following section to check the interface configuration with show commands.
After configuring the new interface, use the show commands to display the status of the new interface or all interfaces. Using the show controller T3 slot/port-adapter/port:t1 channel command, display T3 or T1 channel information as follows, where the T1 channel is 1-28:
Router# show controller t3 3/0/0
Router# show controller t3 3/0/0:5
Router# show controller t3 3/0/0 brief
Following are descriptions and examples of the show commands. Descriptions are limited to fields that are relevant for verifying the configuration.
Router# show version
Copyright (c) 1986-1996 by cisco Systems, Inc.
Compiled Tue 09-Jul-96 09:58 by biff
Image text-base: 0x600108A0, data-base: 0x606C6000
ROM: System Bootstrap, Version 5.3.2(3.2) [kmac 3.2], RELEASED SOFTWARE
ROM: GS Software (RSP-P-M), Version 11.1(9)CA1, RELEASED SOFTWARE
Router uptime is 19 hours, 15 minutes
System restarted by reload
System image file is "rsp-pv-mz", booted via tftp from 1.1.1.254
cisco RSP1 (R4600) processor with 16384K bytes of memory.
R4600 processor, Implementation 32, Revision 2.0
Last reset from power-on
G.703/E1 software, Version 1.0.
X.25 software, Version 2.0, NET2, BFE and GOSIP compliant.
Chassis Interface.
1 VIP2 controller.
1 Channelized T3 port.
125K bytes of non-volatile configuration memory.
8192K bytes of Flash PCMCIA card at slot 0 (Sector size 128K).
8192K bytes of Flash internal SIMM (Sector size 256K).
Configuration register is 0x0
Router# show cont cbus
slot3: VIP2, hw 2.4, sw 21.40, ccb 5800FF40, cmdq 48000090, vps 8192
software loaded from system
IOS (tm) VIP Software (SVIP-DW-M), Version 11.1(9)CA1 [biff 120]
ROM Monitor version 17.0
CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 0.7.0
Mxt H/W version : 2, Mxt ucode ver : 1.24
T3 2/0/0, applique is Channelized T3
gfreeq 48000138, lfreeq 48000168 (1536 bytes), throttled 0
rxlo 4, rxhi 258, rxcurr 4, maxrxcurr 130
Router#
Router# show cont t3 3/0/0
T3 3/0/0 is up.
Applique type is Channelized T3
No alarms detected.
Framing is C-BIT Parity, Line Code is B3ZS, Clock Source is Line.
Data in current interval (120 seconds elapsed):
1 Line Code Violations, 2 P-bit Coding Violation
3 C-bit Coding Violation
4 P-bit Err Secs, 5 P-bit Severely Err Secs
6 Severely Err Framing Secs, 7 Unavailable Secs
8 Line Errored Secs, 9 C-bit Errored Secs, 10 C-bit Severely Errored Secs
Data in Interval 1:
10 Line Code Violations, 12 P-bit Coding Violation
0 C-bit Coding Violation
14 P-bit Err Secs, 15 P-bit Severely Err Secs
16 Severely Err Framing Secs, 17 Unavailable Secs
18 Line Errored Secs, 19 C-bit Errored Secs, 20 C-bit Severely Errored Secs
Data in Interval 2:
10 Line Code Violations, 12 P-bit Coding Violation
0 C-bit Coding Violation
14 P-bit Err Secs, 15 P-bit Severely Err Secs
16 Severely Err Framing Secs, 17 Unavailable Secs
18 Line Errored Secs, 19 C-bit Errored Secs, 20 C-bit Severely Errored Secs
Data in Interval 3:
10 Line Code Violations, 12 P-bit Coding Violation
0 C-bit Coding Violation
14 P-bit Err Secs, 15 P-bit Severely Err Secs
16 Severely Err Framing Secs, 17 Unavailable Secs
18 Line Errored Secs, 19 C-bit Errored Secs, 20 C-bit Severely Errored Secs
T1 0, speed: 1536 kbs
timeslots: 1-24
No alarms detected.
Framing is ESF, LineCode is AMI, Clock Source is Line.
Data in current interval (180 seconds elapsed):
2 Line Code Violations, 1 Path Code Violations
7 Slip Secs, 5 Fr Loss Secs, 8 Line Err Secs, 10 Degraded Mins
3 Errored Secs, 9 Bursty Err Secs, 4 Severely Err Secs, 6 Unavail Secs
Data in Interval 1:
12 Line Code Violations, 11 Path Code Violations
17 Slip Secs, 15 Fr Loss Secs, 18 Line Err Secs, 20 Degraded Mins
13 Errored Secs, 19 Bursty Err Secs, 14 Severely Err Secs, 16 Unavail Secs
Data in Interval 2:
12 Line Code Violations, 11 Path Code Violations
17 Slip Secs, 15 Fr Loss Secs, 18 Line Err Secs, 20 Degraded Mins
13 Errored Secs, 19 Bursty Err Secs, 14 Severely Err Secs, 16 Unavail Secs
Data in Interval 3:
12 Line Code Violations, 11 Path Code Violations
17 Slip Secs, 15 Fr Loss Secs, 18 Line Err Secs, 20 Degraded Mins
13 Errored Secs, 19 Bursty Err Secs, 14 Severely Err Secs, 16 Unavail Secs
T1 1, speed: 1536 kbs
timeslots: 1-24
No alarms detected.
Framing is ESF, LineCode is AMI, Clock Source is Line.
Data in current interval (250 seconds elapsed):
2 Line Code Violations, 1 Path Code Violations
7 Slip Secs, 5 Fr Loss Secs, 8 Line Err Secs, 10 Degraded Mins
3 Errored Secs, 9 Bursty Err Secs, 4 Severely Err Secs, 6 Unavail Secs
Data in Interval 1:
12 Line Code Violations, 11 Path Code Violations
17 Slip Secs, 15 Fr Loss Secs, 18 Line Err Secs, 20 Degraded Mins
13 Errored Secs, 19 Bursty Err Secs, 14 Severely Err Secs, 16 Unavail Secs
Data in Interval 2:
12 Line Code Violations, 11 Path Code Violations
17 Slip Secs, 15 Fr Loss Secs, 18 Line Err Secs, 20 Degraded Mins
13 Errored Secs, 19 Bursty Err Secs, 14 Severely Err Secs, 16 Unavail Secs
Data in Interval 3:
12 Line Code Violations, 11 Path Code Violations
17 Slip Secs, 15 Fr Loss Secs, 18 Line Err Secs, 20 Degraded Mins
13 Errored Secs, 19 Bursty Err Secs, 14 Severely Err Secs, 16 Unavail Secs
Router#
Router# show cont t3
(additional displayed text omitted from this example)
Ext1: LOS, Ext2: LOS, Ext3: LOS, Test: OK
Router# show controller t3 2/0/0 brief
T3 2/0/0 is up.
CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 0.7.0
Mxt H/W version : 2, Mxt ucode ver : 1.24
Applique type is Channelized T3
No alarms detected.
FEAC code received : No code is being received
Framing is C-BIT Parity, Line Code is B3ZS, Clock Source is Internal.
T1 0 is up, speed: 1536 kbs, non-inverted data
timeslots: 1-24
No alarms detected.
Framing is ESF, LineCode is B8ZS, Clock Source is Internal.
T1 1 is up, speed: 1536 kbs, non-inverted data
timeslots: 1-24
No alarms detected.
Framing is ESF, LineCode is B8ZS, Clock Source is Internal.
T1 2 is up, speed: 1536 kbs, non-inverted data
timeslots: 1-24
No alarms detected.
Framing is ESF, LineCode is B8ZS, Clock Source is Internal.
Router# sh cont t3 2/0/0:1 brief
T3 2/0/0 is up.
CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 0.7.0
Mxt H/W version : 2, Mxt ucode ver : 1.24
Applique type is Channelized T3
No alarms detected.
FEAC code received : No code is being received
Framing is C-BIT Parity, Line Code is B3ZS, Clock Source is Internal.
T1 1 is up, speed: 1536 kbs, non-inverted data
timeslots: 1-24
No alarms detected.
Framing is ESF, LineCode is B8ZS, Clock Source is Internal.
Router# show protocols
Serial3/0/0:0 is up, line protocol is up
Internet address is 30.30.30.2/24
Serial3/0/0:1 is up, line protocol is up
Internet address is 1.1.1.2/24
Router# show startup-config
controller T3 3/0/0
cablelength 224
t1 0 timeslots 1-24
t1 1 timeslots 1-24
t1 2 timeslots 1-24
!
interface Serial3/0/0:0
ip address 30.30.30.2 255.255.255.0
no ip route-cache optimum
no keepalive
no fair-queue
!
interface Serial3/0/0:1
ip address 1.1.1.2 255.255.255.0
no ip route-cache optimum
no keepalive
no fair-queue
!
interface Serial3/0/0:2
ip address 2.2.2.2 255.255.255.0
no ip route-cache optimum
no keepalive
no fair-queue
!
(additional display text omitted from this example)
Router# sh int serial 3/0/0:0
Serial3/0/0:0 is up, line protocol is up
Hardware is cxBus T3
Internet address is 30.30.30.2/24
MTU 1500 bytes, BW 1536 Kbit, DLY 20000 usec, rely 255/255, load 1/255
Encapsulation HDLC, loopback not set, keepalive not set
Last input 10:05:52, output 10:05:52, output hang never
Last clearing of "show interface" counters 17:53:35
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 26 drops
5 minute input rate 1426000 bits/sec, 1700 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
102606572 packets input, 2285893928 bytes, 1 no buffer
Received 0 broadcasts, 0 runts, 0 giants
298 input errors, 0 CRC, 0 frame, 298 overrun, 0 ignored, 0 abort
5 packets output, 530 bytes, 0 underruns
0 output errors, 0 collisions, 0 interface resets
0 output buffer failures, 0 output buffers swapped out
0 carrier transitions no alarm present
Timeslot(s) Used:1-24, Transmitter delay is 0 flags, transmit queue length 7 non-inverted data
The following procedure summarizes how to use the show commands to verify that a new CT3IP interface is configured correctly:
Step 1 Use the show version command to display the system hardware configuration. Ensure that the list includes the new CT3IP network interface.
Step 2 Display all of the current CxBus interface processors and their interfaces with the show controllers cbus command. Verify that the new CT3IP appears in the correct slot.
Step 3 Display the T1 alarm condition with the show controllers T3 command.
Step 4 Specify the new interface with the show interfaces command and verify that the first line of the display specifies the serial interface with the correct slot, port adapter, and port. Also verify that the interface and line protocol are in the correct state: up or down.
Step 5 Display the protocols configured for the entire system and specific interfaces with the command show protocols. If necessary, return to the configuration mode to add or remove protocol routing on the system or specific interfaces.
Step 6 Display the entire system configuration file with the show running-config and show startup-config commands. Verify that the configuration is accurate for the system and each interface.
If the interface is down and you configured it as up, or if the displays indicate that the hardware is not functioning properly, ensure that the network interface is properly connected and terminated. If you still have problems bringing the interface up, contact a customer service representative for assistance.
This completes the configuration procedure for the new CT3IP interface.
Following are suggested guidelines for troubleshooting the CT3IP using the loopback command, LED indications, a bit error rate test (BERT), FDL performance reports, and for displaying remote performance reports.
Should you have difficulty with the CT3IP configuration or installation, you can troubleshoot the CT3IP using the loopback interface configuration command. Specify loopback for a T1 channel where the T1 channel is 1-28. Specify the loopback format using the following command format:
loopback [local | network {line | payload} | remote {line {fdl {ansi | bellcore} | inband} payload [fdl] [ansi]}]
Use the no form of this command to remove the loopback.
Explanations of specific loopback modes follow:
| local | (Optional) Loops the router output data back toward the router at the T1 framer and sends an AIS signal out toward the network. |
| network {line | payload} | (Optional) Loops the data back toward the network before the T1 framer and automatically sets a local loopback at the HDLC controllers (line) or loops the payload data back toward the network at the T1 framer and automatically sets a local loopback at the HDLC controllers (payload). |
| remote line fdl {ansi | bellcore} | (Optional) Sends a repeating, 16-bit ESF data link code word (00010010 11111111) to the remote end requesting that it enter into a network line loopback. Specify the ansi keyword to enable the remote line Facility Data Link (FDL) ANSI bit loopback on the T1 channel, per the ANSI T1.403 Specification. Specify the bellcore keyword to enable the remote SmartJack loopback on the T1 channel, per the TR-TSY-000312 Specification. |
| remote line inband | (Optional) Sends a repeating, 5-bit inband pattern (00001) to the remote end requesting that it enter into a network line loopback. |
| remote payload [fdl] [ansi] | (Optional) Sends a repeating, 16-bit ESF data link code word (00010100 11111111) to the remote end requesting that it enter into a network payload loopback. Enables the remote payload Facility Data Link (FDL) ANSI bit loopback on the T1 channel.
You can optionally specify fdl and ansi, but it is not necessary. |
Examples of using the loopback command follow:
Router#config tEnter configuration commands, one per line. End with CNTL/Z. Router(config)#interface serial 2/0/0:1Router(config)#loopback local
Router#config tEnter configuration commands, one per line. End with CNTL/Z. Router(config)#interface serial 2/0/0:1Router(config)#loopback network line
Router#config tEnter configuration commands, one per line. End with CNTL/Z. Router(config)#interface serial 2/0/0:1Router(config)#loopback network payload
Router#config tEnter configuration commands, one per line. End with CNTL/Z. Router(config)#int serial 2/0/0:1Router(config-if)#loop remote line fdl ansi
Router#config tEnter configuration commands, one per line. End with CNTL/Z. Router(config)#int serial 2/0/0:1Router(config-if)#loop remote line fdl bellcore
Router#config tEnter configuration commands, one per line. End with CNTL/Z. Router(config)#int serial 2/0/0:1Router(config-if)#loop remote line inband
Router#config tEnter configuration commands, one per line. End with CNTL/Z. Router(config)#int serial 2/0/0:1Router(config-if)#loop remote payload fdl ansi
To better diagnose T1 provisioning problems, you can place the remote CSU or remote SmartJack into loopback. The loopback remote line fdl interface configuration command allows you to place either the CSU or the SmartJack into loopback:
When both are configured, transmission of LOF indication (yellow alarm) takes priority over transmission of some FDL messages.
If the remote loopback appears not to be working, use the show cont t3 command to determine if the given T1 is currently attempting to transmit a LOF indication (yellow alarm):
Router# show controllers t3 2/0/0:2 T3 2/0/0 is up. CT3 H/W Version: 5, CT3 ROM Version: 1.2, CT3 F/W Version: 2.5.9 Mx H/W version: 2, Mx ucode ver: 1.34 T1 2 is down, speed: 1536 kbs, non-inverted data timeslots: 1-24 FDL per AT&T 54016 spec. Transmitter is sending LOF Indication. Receiver is getting AIS.
If the transmitter is sending a LOF indication, as in the previous example, stop the transmission of the LOF indication (yellow alarm) with the no t1 yellow generation configuration command as shown in the following example:
Router(config)#controllers t3 2/0/0Router(config-controll)#no t1 2 yellow generationRouter(config-controll)#^D
To verify that the transmission of the LOF indication (yellow alarm) has stopped, use the show cont t3 command:
Router# show cont t3 2/0/0:2
T3 0/0/0 is up.
CT3 H/W Version: 5, CT3 ROM Version: 1.2, CT3 F/W Version: 2.5.9
Mx H/W version: 2, Mx ucode ver: 1.34
T1 2 is down, speed: 1536 kbs, non-inverted data
timeslots: 1-24
FDL per AT&T 54016 spec.
Receiver is getting AIS.
Framing is ESF, Line Code is B8ZS, Clock Source is Internal.
Yellow Alarm Generation is disabled
Now retry the remote loopback command. When diagnosis is complete, remember to re-enable the LOF indication (yellow alarm). You can also loopback all the T1 channels by using the loopback (CT3IP) interface configuration command.
Following are various system states and functions that are reflected by the front-panel alarm and status LEDs on the CT3IP during the CPU boot process and microcode download.
1 ) After the CT3IP CPU has booted successfully, the alarm and status LEDs goes on.
2 ) When the CT3IP microcode download begins, the alarm LED goes off while the status LED flashes on and off.
3 ) After the CT3IP microcode is downloaded (and before the CT3IP microcode image boots) the status LED goes off.
During the system bootup process and microcode download, the following LED error indications might appear:
In all the preceding error modes, the CPU continually loops and the system does not proceed to the microcode download.
To check bit errors using a bit error test (BERT), use the following command:
[no]t1t1 channelbert pattern{2^15|2^20|2^23|0s|1s}intervalminutes
where t1 channel is 1-28, 2^15 is an exponential number that represents a pseudo-random repeating pattern that is 32767 bits long, 2^20 is a pseudo-random repeating pattern that is 1048575 bits long, 2^23 is a pseudo-random repeating pattern that is 8388607 bits long, 0s is a pattern of all zeroes (00000000...), 1s is a pattern of all 1s (111111...), and minutes are 1-14400, which designate the time the BERT will run. To stop the BERT, use the optional no form of the command. Following is an example of this command, where the pseudo-random pattern 2^20 is sent and repeats on the first T1 channel for 60 minutes:
Router# t1 1 bert pattern 2^20 interval 60
Note that the BERT command is not saved in NVRAM. The test patterns from the CT3IP are framed test patterns; therefore, they are inserted into the payload of a framed T1 signal.
To display the BERT results, use the following EXEC commands: sh cont t3 number or sh cont t3 number brief.
Following are examples of displaying BERT results output:
1 ) Display BERT output results during a test, as follows:
Router# sh cont t3 3/0/0 b
T3 3/0/0 is up.
CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 20.2.0
Mx H/W version : 2, Mx ucode ver : 1.25
Applique type is Channelized T3
No alarms detected.
FEAC code received : No code is being received
Framing is M23, Line Code is B3ZS, Clock Source is Internal.
T1 1 is down, speed: 1536 kbs, non-inverted data
timeslots: 1-24
FDL per ANSI T1.403 and AT&T 54016 spec.
Configured for FDL Remotely Line Looped
No alarms detected.
Framing is ESF, Line Code is B8ZS, Clock Source is Internal.
BERT test result (running)
Test Pattern : All 0's, Status : Sync, Sync Detected : 1
Interval : 4 minute(s), Time Remain : 4 minute(s)
Bit Errors(Sync BERT Started) : 0 bits
Bit Errors(Sync last Sync) : 0 bits , Bits Received : 7 Mbits
2 ) When the test is done, display BERT results output as follows:
Router# sh cont t3 3/0/0 b
T3 3/0/0 is up.
CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 20.2.0
Mx H/W version : 2, Mx ucode ver : 1.25
Applique type is Channelized T3
No alarms detected.
FEAC code received : No code is being received
Framing is M23, Line Code is B3ZS, Clock Source is Internal.
T1 1 is up, speed: 1536 kbs, non-inverted data
timeslots: 1-24
FDL per ANSI T1.403 and AT&T 54016 spec.
Configured for FDL Remotely Line Looped
No alarms detected.
Framing is ESF, Line Code is B8ZS, Clock Source is Internal.
BERT test result (done)
Test Pattern : All 0's, Status : Not Sync, Sync Detected : 1
Interval : 4 minute(s), Time Remain : 0 minute(s)
Bit Errors(Sync BERT Started) : 0 bits
Bit Errors(Sync last Sync) : 0 bits , Bits Received : 368 Mbits
3 ) When the test is stopped prematurely, display BERT results output as follows:
Router# sh cont t3 3/0/0 b
T3 3/0/0 is up.
CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 20.2.0
Mx H/W version : 2, Mx ucode ver : 1.25
Applique type is Channelized T3
No alarms detected.
FEAC code received : No code is being received
Framing is M23, Line Code is B3ZS, Clock Source is Internal.
T1 1 is up, speed: 1536 kbs, non-inverted data
timeslots: 1-24
FDL per ANSI T1.403 and AT&T 54016 spec.
Configured for FDL Remotely Line Looped
No alarms detected.
Framing is ESF, Line Code is B8ZS, Clock Source is Internal.
BERT test result (done)
Test Pattern : All 0's, Status : Not Sync, Sync Detected : 1
Interval : 4 minute(s), Time Remain : 2 minute(s) (unable to complete)
Bit Errors(Sync BERT Started) : 0 bits
Bit Errors(Sync last Sync) : 0 bits , Bits Received : 368 Mbits
To enable and disable one-second transmissions of performance reports via the FDL (per ANSI T1.403), use the [no] t1 t1 channel fdl ansi command, where the T1 channel is 1-28.
To display remote (far-end) performance data, use the show controller t3 3/0/0 remote performance command, as follows:
Router# sh cont t3 3/0/0 remote performance
T3 3/0/0 is up.
CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 20.2.0
Mx H/W version : 2, Mx ucode ver : 1.25
T1 1 - Remote Performance Data
Data in current interval (356 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
Data in Interval 1:
1 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
2 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
Data in Interval 2:
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
Total Data (last 2 15 minute intervals):
1 Path Code Violations
1 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
2 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
T1 2 - Remote Performance Data
Data in current interval (425 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
Data in Interval 1:
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
Data in Interval 2:
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
Total Data (last 2 15 minute intervals):
0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
Cisco 7000 series and Cisco 7500 series routers support downloadable microcode. You can download new microcode versions and store multiple versions in Flash memory, and you can boot from them just as you can with the system software images. System software upgrades might also contain upgraded microcode images, which will load automatically when the new software image is loaded.
You can download microcode to Flash memory by copying the TFTP image of a microcode version to Flash memory. When the microcode image is stored in Flash memory, you can use the microcode reload command to manually load the new microcode file, and the configure command to instruct the system to load the new image automatically at each system boot.
Caution Before you copy a file to Flash, be sure there is ample space available in Flash memory. Compare the size of the file you want to copy to the amount of available Flash memory shown. If the space available is less than the space required by the file you wish to copy, the copy process will continue, but the entire file will not be copied into Flash.
To compare the size of the microcode image and the amount of Flash memory available, you must know the size of the new microcode image. The image size is specified in the README file that is included on the floppy disk with the new image, and in the Upgrading System Software and Microcode in the Cisco 7XXX publication that is shipped with all microcode upgrades. Note the size of the new image before proceeding to ensure that you have sufficient available Flash memory for the new image.
Follow these steps to copy a microcode version from the TFTP server to Flash memory:
Step 1 To display the total amount of Flash memory present, its location, any files that currently exist in Flash memory and their size, and the amount of Flash memory remaining, use the show flash command. Following is an example of the output that is displayed:
show flash
Step 2 Compare the amount of available Flash memory (last line in the preceding example) to the size of the new microcode image on the floppy disk to ensure that there is sufficient space available. If you attempt to copy in a new image, and the size of the new image exceeds the available space in Flash, only part of the new image will be copied, and the following error message will be displayed:
xxxx/xxxx
where xxxx/xxxx is the number of bytes read in/number of bytes available.
Step 3 After you verify that there is sufficient space available in Flash memory for the new image, enter the following command at the privileged-level prompt:
copy tftp flash
Step 4 Enter the IP address of the remote host:
Step 5 Enter the name of the file you want to copy to Flash (vip221-40 in the following example):
ip221-40
Step 6 To confirm that you want the file copied into Flash, press Return.
If the correct file is not shown, enter no at the prompt to return to the system prompt and enter the correct file name.
Step 7 If you do not want Flash erased, enter no at the next prompt. If you accept the default to erase by pressing Return without first typing no, the new image will write over the entire contents of Flash memory, and you will lose all other microcode and system software images stored in Flash.
no
While the file is copied to Flash, output similar to the following is displayed:
Step 8 Use the show flash command to verify that the microcode has been copied to Flash. The output should display the file name of the image you copied to Flash (vip221-40 in the following example):
show flash
4096K bytes of flash memory on embedded flash (in RSP1).
Step 9 To ensure that the new microcode is used when you reboot the system, add the appropriate commands to the configuration file. To modify the configuration file, enter the following command:
configure terminal
Step 10 Specify that you are changing the microcode for the CT3IP (microcode vip2), and that it will load from Flash memory (flash). Then add the filename of the new microcode image to be loaded from Flash:
microcode vip2 flash vip221-40
Step 11 To save the configuration file, press Ctrl-Z.
Step 12 Copy the new configuration to NVRAM as follows:
copy running-config startup-config
The microcode reload command is automatically added to your running configuration. The new CT3IP microcode image will load automatically the next time the system boots or reinitializes.
Step 13 To load the new microcode immediately, you can instruct the system to load the new microcode by issuing the microcode reload configuration command (you must be in Configuration mode to enter this command):
configure
microcode reload
Immediately after you enter the microcode reload command and press Return, the system reloads all microcode. Configuration mode remains enabled; after the reload is complete, press Ctrl-Z to exit from Configuration mode and return to the system prompt.
Step 14 To verify that the CT3IP is using the correct microcode, issue the show running-config, show startup-config, or show controller cbus commands. The show controller cbus display also indicates the currently loaded and running microcode version for each interface processor.
show running-config
This completes the procedure for downloading microcode to Flash memory.
The following procedures describe the steps required to replace the DRAM or SRAM if a system problem has indicated their replacement or an upgrade is required.
The current CT3IP products include the following:
The following sections describe upgrading DRAM and SRAM:
The DRAM on the CT3IP is contained in two SIMMs located in sockets U2 and U6. (See Figure 8.) If a system problem is determined to be caused by a SIMM, a SIMM replacement might be required. Use the following procedures to replace the DRAM SIMMs on your CT3IP.
Caution To prevent ESD damage, handle SIMMs by the card edges only. (See Figure 10 on page 46.) Place removed SIMMs on an antistatic mat and store them in an antistatic container.
Follow these steps to remove the existing SIMMs:
Step 1 Turn OFF the system power and follow the steps in the section "Removing a CT3IP" on page 14.
Step 2 Place the CT3IP on an antistatic mat or pad and ensure that you are wearing an antistatic device, such as a wrist strap. Position the CT3IP so that the handle is away from you and the bus connector is toward you--opposite of the position shown in Figure 8.
Step 3 Locate the SIMMs. The DRAM SIMMs occupy sockets U2 and U6. (See Figure 8.)

Step 4 Release the spring clips from the SIMM that you want to remove and release the SIMM from the socket. (See Figure 9.)

Step 5 When both ends of the SIMM are released from the socket, grasp the ends of the SIMM with your thumb and forefinger and pull the SIMM completely out of the socket. Handle the edges of the SIMM only; avoid touching the memory module or pins and the metal traces, or fingers, along the socket edge.
Step 6 Place the SIMM in an antistatic container to protect it from ESD damage.
Step 7 Repeat steps 4 through 6 for the remaining SIMM, as required for this replacement.
This completes the SIMM removal procedure. Proceed to the next section to install the new SIMMs.
SIMMs are sensitive components that are susceptible to ESD damage. Handle SIMMs by the edges only; avoid touching the memory modules, pins, or traces (the metal fingers along the connector edge of the SIMM). (See Figure 10.)

Caution To prevent ESD damage, handle SIMMs as shown in Figure 10.
Follow these steps to install the new SIMMs:
Step 1 With the CT3IP in the same orientation as the previous procedure (with the handle away from you and the bus connector toward you), you are going to install the first SIMM in the socket farthest from you. Then you will install the last SIMM in the socket closest to you.
Step 2 Remove a new SIMM from the antistatic container.
Step 3 Hold the SIMM component side up, with the connector edge (the metal fingers) closest to you.
Step 4 Hold the sides of the SIMM between your thumb and fore finger, with your forefinger against the far edge, opposite the connector edge. (See Figure 10.)
Step 5 Tilt the SIMM to approximately the same an angle as the socket and insert the connector edge into the socket.
Caution When inserting SIMMs, use firm but not excessive pressure. If you damage a socket, you will have to return the CT3IP to the factory for repair.
Step 6 Gently push the SIMM into the socket until the spring clips snap over the ends of the SIMM. If necessary, rock the SIMM gently back and forth to seat it properly.
Step 7 Repeat steps 2 through 6 for the remaining SIMMs.
Step 8 When both SIMMs are installed, check all four alignment holes (two on each SIMM) and ensure that the spring retainer is visible. If it is not, the SIMM is not seated properly. If any SIMM appears misaligned, carefully remove it and reseat it in the socket. Push the SIMM firmly back into the socket until the retainer springs snap into place.
This completes the SIMM replacement procedure. Proceed to the section "Replacing the CT3IP SRAM DIMM."
The SRAM on the CT3IP is contained in a DIMM and located in socket U5. (See Figure 8 on page 44.) If a system problem is determined to be caused by the DIMM, a DIMM replacement might be required. Use the following procedures to replace the SRAM DIMM on your CT3IP.
Caution To prevent ESD damage, handle the DIMM by the edges only. Place a removed DIMM on an antistatic mat and store it in an antistatic container.
Follow these steps to remove the existing DIMM:
Step 1 Turn OFF the system power and follow the steps in the section "Removing a CT3IP" on page 14, if required.
Step 2 Place the CT3IP on an antistatic mat or pad and ensure that you are wearing an antistatic device, such as a wrist strap. Position the CT3IP so that the handle is toward you and the bus connector is facing away from you, approximately as shown in Figure 8.
Step 3 Locate the DIMM. The SRAM DIMM occupies socket U5. (See Figure 8.)
Step 4 Locate the release lever on the DIMM socket (see circle in Figure 11) and release the DIMM from the socket as shown.
Step 5 When one end of the DIMM is released from the socket (see Figure 11), grasp the ends of the DIMM with your thumb and forefinger and pull the DIMM completely out of the socket. Handle the edges of the DIMM only. (See Figure 12.)

Step 6 Place the DIMM in an antistatic container to protect it from ESD damage.
This completes the DIMM removal procedure. Proceed to the next section to install the new DIMM.
The DIMM is a sensitive component that is susceptible to ESD damage. Handle the DIMM by the edges only; avoid touching the memory modules, pins, or traces (the metal fingers along the connector edge of the DIMM). (See Figure 12.)

Caution To prevent ESD damage, handle the DIMM as shown in Figure 12.
Follow these steps to install the new DIMM:
Step 1 With the CT3IP in the same orientation as the previous procedure (with the handle toward you and the bus connector away from you), you will install the DIMM in socket U5.
Step 2 Remove the new DIMM from the antistatic container.
Step 3 Hold the DIMM component side up, with the connector edge (the metal fingers) down. (See Figure 12.) Hold the sides of the DIMM between your thumb and fore finger.
Step 4 Tilt the DIMM to approximately the same an angle as the socket and insert the connector edge into the socket. Note the two notches (keys) on the connector edge of the DIMM. (See Figure 12.) These keys are intended to assure correct orientation of the DIMM in the socket.
Caution When inserting the DIMM, use firm but not excessive pressure. If you damage a socket, you will have to return the CT3IP to the factory for repair.
Step 5 Note the orientation of the socket key on the SRAM DIMM and the DIMM socket and gently push the DIMM into the socket until the release lever is flush against the side of the DIMM socket (see Figure 13), and the DIMM's edge connector is fully inserted. If necessary, rock the DIMM gently back and forth to seat it properly.

Step 6 When the DIMM is installed, check that the release lever is flush against the side of the DIMM socket. (See Figure 13.) If it is not, the DIMM might not be seated properly. If the DIMM appears misaligned, carefully remove it according to the removal procedure, and reseat it in the socket. Push the DIMM firmly back into the socket until release lever is flush against the side of the DIMM socket.
This completes the DIMM replacement procedure.
Proceed to the section "Installing a CT3IP," on page 16, to replace the CT3IP in the chassis; then restart the system for an installation check. Refer to the section "Checking DRAM and SRAM Replacement."
If, after a DRAM or SRAM replacement, the system fails to boot properly, or if the console terminal displays a checksum or memory error, check the following:
Refer to the section "Using LEDs to Check CT3IP Initialization," on page 18, as required. If after several attempts the system fails to restart properly, contact a service representative for assistance. Before you call, make note of any error messages, unusual LED states, or any other indications that might help solve the problem.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures:
Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product.
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.

|
|