cc/td/doc/product/core/cis7010
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Cabling Specifications

Cabling Specifications

This appendix lists the pinouts for ports on the RP (or RSP7000), EIP, TRIP, FIP optical bypass switch, and MIP for the serial interface cables that connect each FSIP and HSSI port to the external network.

All pins not specifically listed are not connected.

Following is a list of the signal summaries contained in this appendix:


Note All FSIP ports use a universal high-density, 60-pin receptacle (except for the E1-G.703/G.704 port adapter, which uses DB-15 connectors). Each universal port requires a serial port adapter cable, which determines the port's electrical interface type and mode: DTE or DCE. Although all port adapter cables use a universal plug at the FSIP end, the network end of each cable type uses the physical connectors commonly used for the interface. (For example, the network end of the EIA/TIA-232 port adapter cable is a DB-25, the most widely used EIA/TIA-232 connector.)

Console Port Signals

The console port on the RP (and RSP7000) is an EIA/TIA-232, DCE, DB-25 receptacle. Both DSR and DCD are active when the system is running. The RTS signal tracks the state of the CTS input. The console port does not support modem control or hardware flow control. Table A-1 lists the signals used on this port. The console port requires a straight-through EIA/TIA-232 cable.


Table  A-1: Console Port Signals
Pin Signal Direction Description
1 GND

-

Ground
2 TxD

<--

Transmit Data
3 RxD

-->

Receive Data
6 DSR

-->

Data Set Ready (always on)
7 GND

-

Ground
8 DCD

-->

Data Carrier Detect (always on)

Auxiliary Port Signals

The auxiliary port on the RP (and RSP7000) is an EIA/TIA-232 DTE, DB-25 plug to which you can attach a CSU/DSU or other equipment in order to access the router from the network. Table A-2 lists the EIA/TIA-232 signals used on this port.

The auxiliary port supports hardware flow control and modem control.


Table  A-2: Auxiliary Port Signals
Pin Signal Direction Description
2 TxD

-->

Transmit Data
3 RxD

<--

Receive Data
4 RTS

-->

Request To Send (used for hardware flow control)
5 CTS

<--

Clear To Send (used for hardware flow control)
6 DSR

<--

Data Set Ready
7 Signal Ground

-

Signal Ground
8 CD

<--

Carrier Detect (used for modem control)
20 DTR

-->

Data Terminal Ready (used for modem control only)

Ethernet Connector Signals

Most Ethernet transceivers require an attachment unit interface (AUI) or transceiver cable to connect an Ethernet transceiver to the EIP Ethernet ports. Some unshielded twisted-pair (10BaseT) transceivers are compact enough to connect directly to the EIP ports without impeding other connections. For descriptions of Ethernet transceivers, connectors, and cables, refer to the section "Ethernet Connection Equipment" in the chapter "Preparing for Installation."

Table A-3 lists the signals for the 15-pin Ethernet connector used on the EIP.


Table  A-3: Ethernet Connector Signals
Pin Circuit Description
3 DO-A Data Out Circuit A
10 DO-B Data Out Circuit B
11 DO-S Data Out Circuit Shield
5 DI-A Data In Circuit A
12 DI-B Data In Circuit B
4 DI-S Data In Circuit Shield
7 CO-A Control Out Circuit A (not used)
15 CO-B Control Out Circuit B (not used)
8 CO-S Control Out Circuit Shield (not used)
2 CI-A Control In Circuit A
9 CI-B Control In Circuit B
1 CI-S Control In Circuit Shield
6 VC Voltage Common
13 VP Voltage Plus
14 VS Voltage Shield
Shell PG Protective Ground

Fast Ethernet Connector Signals

The two connectors on the FEIP are a single MII, 40-pin, D-shell type, and a single RJ-45. You can use either one or the other. Only one connector can be used at one time. Each connection supports IEEE 802.3u interfaces compliant with the 100BaseX and 100BaseT standards. The RJ-45 connection does not require an external transceiver; however, the MII connection does.

The RJ-45 modular connector has strain-relief functionality incorporated into the design of its standard plastic connector.Table A-4 and Table A-5 list the pinouts and signals for the RJ-45 and MII connectors.


Table  A-4: FEIP Port Adapter RJ-45 Connector Pinout
Pin Description
1 Receive Data + (RxD+)
2 RxD-
3 Transmit Data + (TxD+)
6 TxD-

Note Referring to the RJ-45 pinout in
Table A-4, proper common-mode line terminations should be used for the unused Category 5, UTP cable pairs 4/5 and 7/8. Common-mode termination reduces the contributions to electromagnetic interference (EMI) and susceptibility to common-mode sources. Wire pairs 4/5 and 7/8 are actively terminated in the RJ-45, 100BaseTX port circuitry in the FEIP port adapter.

Table  A-5: FEIP Port Adapter MII Connector Pinout
Pin1 In Out I/O Description
14-17 - Yes - Transmit Data (TxD)
12 Yes - - Transmit Clock (Tx_CLK)1
11 - Yes - Transmit Error (Tx_ER)
13 - Yes - Transmit Enable (Tx_EN)
3 - Yes - MII Data Clock (MDC)
4-7 Yes - - Receive Data (RxD)
9 Yes - - Receive Clock (Rx_CLK)
10 Yes - - Receive Error (Rx_ER)
8 Yes - - Receive Data Valid (Rx_DV)
18 Yes - - Collision (COL)
19 Yes - - Carrier Sense (CRS)
2 - - Yes MII Data Input/Output (MDIO)
22-39 - - - Common (ground)
1, 20, 21, 40 - - - +5.0 volts (V)

1 Tx_CLK and Rx_CLK are provided by the external transceiver.

Token Ring Port Signals

A network interface cable provides the connection between the 9-pin Token Ring connectors on the TRIP and a media access unit (MAU). The 9-pin connector at the TRIP end, and the MAU connector at the network end, are described in "Token Ring Connection Equipment" in the chapter "Preparing for Installation." Table A-6 lists the signals for the DB-9 Token Ring connector used on the TRIP.


Table  A-6: Token Ring Connector Signals
Pin Signal
1 Ring-In B
5 Ring-Out A
6 Ring-In A
9 Ring-Out B
10 and 11 Ground

FDDI Optical Bypass Switch Signals

Table A-5 lists the signal descriptions for the mini-DIN optical bypass switch available on the multimode/multimode FIP (CX-FIP-MM) and single-mode/single-mode FIP (CX-FIP-SS). The mini-DIN-to-DIN adapter cable (CAB-FMDD) allows connection to an optical bypass switch that uses a DIN connector (which is larger than the mini-DIN on the FIP). For descriptions of FDDI network configurations and equipment, refer to the section "FDDI Connection Equipment" in the chapter "Preparing for Installation" and to the section "FDDI Connections" in the chapter "Installing the Router."


Table  A-7: Optical Bypass Switch Pinout
Pin Description
1 +5V to secondary switch
2 +5V to primary switch
3 Ground to enable primary switch
4 Ground to enable secondary switch
5 Sense circuit--1 kohm to +5V
6 Ground--Sense circuit return

Serial Adapter Cable Pinouts

The FSIP supports EIA/TIA-232, EIA/TIA-449, X.21, V.35, and EIA-530 serial interfaces.

All FSIP ports use a universal port adapter, which is a 60-pin receptacle that supports all available interface types. (The exception to this is the E1-G.703/G.704 port adapter, which uses a DB-15 connector.) A special serial adapter cable, which is required for each port, determines the electrical interface type and mode of the interface. The router (FSIP) end of all of the adapter cables is a 60-pin plug; the connectors at the network end are the standard connectors used for the respective interfaces.

All interface types except EIA-530 are available in DTE or DCE format: DTE with a plug connector at the network end and DCE with a receptacle at the network end. V.35 is available in either mode with either gender at the network end. EIA-530 is available in DTE only.

The tables that follow list the signal pinouts for both the DTE and DCE mode serial port adapter cables for each FSIP interface type. For descriptions of serial interface connection and equipment, refer to the section "Serial Connection Equipment" in the chapter "Preparing for Installation" and to the section "Serial Connections" in the chapter "Installing the Router."


Table  A-8: EIA/TIA-232 Adapter Cable Signals
FSIP End, HD 60-Position Plug DTE Cable Network End, DB-25 Plug FSIP End, HD 60-Position Plug DCE Cable Network End, DB-25 Receptacle
Signal (J1) Pin Pin Signal (J2) Signal (J1) Pin Pin Signal (J2)
Shield ground 46 1 Shield ground Shield ground 46 1 Shield ground
TxD/RxD
Not used
41
56
-->
2
7
TxD
Not used
RxD/TxD
Not used
36
56
<--
2
7
TxD
Not used
RxD/TxD
Not used
36
56
<--
3
7
RxD
Not used
TxD/RxD
Not used
41
56
-->
3
7
RxD
Not used
RTS/CTS
Not used
42
56
-->
4
7
RTS
Not used
CTS/RTS
Not used
35
56
<--
4
7
RTS
Not used
CTS/RTS
Not used
35
56
<--
5
7
CTS
Not used
RTS/CTS
Not used
42
56
-->
5
7
CTS
Not used
DSR/DTR
Not used
34
56
<--
6
7
DSR
Not used
DTR/DSR
Not used
43
56
-->
6
7
DSR
Not used
Circuit ground
Not used
45
56
7
7
Circuit ground
Not used
Circuit ground
Not used
45
56
7
7
Circuit ground
Not used
DCD/LL
Not used
33
56
<--
8
7
DCD
Not used
LL/DCD
Not used
44
56
-->
8
7
DCD
Not used
TxC/NIL
Not used
37
56
<--
15
7
TxC
Not used
TxCE/TxC
Not used
39
56
-->
15
7
TxC
Not used
RxC/TxCE
Not used
38
56
<--
17
7
RxC
Not used
NIL/RxC
Not used
40
56
-->
17
7
RxC
Not used
LL/DCD
Not used
44
56
-->
18
7
LTST
Not used
DCD/LL
Not used
33
56
<--
18
7
LTST
Not used
DTR/DSR
Not used
43
56
-->
20
7
DTR
Not used
DSR/DTR
Not used
34
56
<--
20
7
DTR
Not used
TxCE/TxC
Not used
39
56
-->
24
7
TxCE
Not used
RxC/TxCE
Not used
38
56
<--
24
7
TxCE
Not used
Mode 0
Ground
Mode_DCE
50
51
52

Shorting group
Mode 0
Ground
50
51

Shorting group

Table  A-9: EIA/TIA-449 Adapter Cable Signals
FSIP End, HD 60-Position Plug DTE Cable Network End, DB-37 Plug FSIP End, HD 60-Position Plug DCE Cable Network
End,
DB-37 Receptacle
Signal (J1) Pin Pin Signal (J2) Signal (J1) Pin Pin Signal (J2)
Shield ground 46 1 Shield ground Shield ground 46 1 Shield ground
TxD/RxD+
TxD/RxD-
11
12
-->
-->
4
22
SD+
SD-
RxD/TxD+
RxD/TxD-
28
27
<--
<--
4
22
SD+
SD-
TxC/RxC+
TxC/RxC-
24
23
<--
<--
5
23
ST+
ST-
TxCE/TxC+
TxCE/TxC-
13
14
-->
-->
5
23
ST+
ST-
RxD/TxD+
RxD/TxD-
28
27
<--
<--
6
24
RD+
RD-
TxD/RxD+
TxD/RxD-
11
12
-->
-->
6
24
RD+
RD-
RTS/CTS+
RTS/CTS-
9
10
-->
-->
7
25
RS+
RS-
CTS/RTS+
CTS/RTS-
1
2
<--
<--
7
25
RS+
RS-
RxC/TxCE+
RxC/TxCE-
26
25
<--
<--
8
26
RT+
RT-
TxC/RxC+
TxC/RxC-
24
23
-->
-->
8
26
RT+
RT-
CTS/RTS+
CTS/RTS-
1
2
<--
<--
9
27
CS+
CS-
RTS/CTS+
RTS/CTS-
9
10
-->
-->
9
27
CS+
CS-
LL/DCD
Circuit ground
44
45
-->
-->
10
37
LL
SC
NIL/LL
Circuit ground
29
30
-->
-->
10
37
LL
SC
DSR/DTR+
DSR/DTR-
3
4
<--
<--
11
29
DM+
DM-
DTR/DSR+
DTR/DSR-
7
8
-->
-->
11
29
DM+
DM-
DTR/DSR+
DTR/DSR-
7
8
-->
-->
12
30
TR+
TR-
DSR/DTR+
DSR/DTR-
3
4
<--
<--
12
30
TR+
TR-
DCD/DCD+
DCD/DCD-
5
6
<--
<--
13
31
RR+
RR-
DCD/DCD+
DCD/DCD-
5
6
-->
-->
13
31
RR+
RR-
TxCE/TxC+
TxCE/TxC-
13
14
-->
-->
17
35
TT+
TT-
RxC/TxCE+
RxC/TxCE-
26
25
<--
<--
17
35
TT+
TT-
Circuit ground
Circuit ground
15
16
19
20
SG
RC
Circuit ground
Circuit ground
15
16
19
20
SG
RC
Mode 1
Ground
49
48
Shorting group Mode 1
Ground
49
48
Shorting group
Ground
Mode_DCE
51
52
Shorting group

Table  A-10: X.21 Adapter Cable Signals
FSIP End, HD 60-Position Plug DTE Cable Network End, DB-15 Plug SIP End, HD 60-Position Plug DCE Cable Network End, DB-15 Receptacle
Signal (J1) Pin Pin Signal (J2) Signal (J1) Pin Pin Signal (J2)
Ground 46 1 Shield ground 46 1 Shield ground
TxD/RxD+
TxD/RxD-
11
12
-->
-->
2
9
Transmit+
Transmit-
RxD/TxD+
RxD/TxD-
28
27
<--
<--
2
9
Transmit+
Transmit-
RTS/CTS+
RTS/CTS -
9
10
-->
-->
3
10
Control+
Control-
CTS/RTS+
CTS/RTS -
1
2
<--
<--
3
10
Control+
Control-
RxD/TxD+
RxD/TxD-
28
27
<--
<--
4
11
Receive+
Receive-
TxD/RxD+
TxD/RxD-
11
12
-->
-->
4
11
Receive+
Receive-
CTS/RTS+
CTS/RTS -
1
2
<--
<--
5
12
Indication+
Indication-
RTS/CTS+
RTS/CTS-
9
10
-->
-->
5
12
Indication+
Indication-
RxC/TxCE+
RxC/TxCE-
26
25
<--
<--
6
13
Timing+
Timing-
TxC/RxC+
TxC/RxC -
24
23
-->
-->
6
13
Timing+
Timing-
Circuit ground 15 8 Circuit ground Circuit ground 15 8 Circuit ground
Ground
Mode_2
48
47
Shorting group Ground
Mode_2
48
47
Shorting
group
Ground
Mode_DCE
51
52
Shorting group
Not used 16 8 Not used Not used 16 8 Not used

Table  A-11: V.35 Adapter Cable Signals
FSIP End, HD 60-Position Plug DTE Cable Network End, 34-Position Plug FSIP End, HD 60-Position Plug DCE Cable Network End, 34-Position Receptacle
Signal (J1) Pin

Pin Signal (J2) Signal (J1) Pin

Pin Signal (J2)
Shield ground 46 A Shield ground Shield ground 46 A Shield ground
Circuit ground
Not used
45
16
B
B
Circuit ground
Not used
Circuit ground
Not used
45
18
B
B
Circuit ground
Not used
RTS/CTS
Not used
42
16
-->
C
B
RTS
Not used
CTS/RTS
Not used
35
18
<--
C
B
RTS
Not used
CTS/RTS
Not used
35
16
<--
D
B
CTS
Not used
RTS/CTS
Not used
42
18
-->
D
B
CTS
Not used
DSR/DTR
Not used
34
16
<--
E
B
DSR
Not used
DTR/DSR
Not used
43
18
-->
E
B
DSR
Not used
DCD/LL
Not used
33
16
<--
F
B
RLSD
Not used
LL/DCD
Not used
44
18
-->
F
B
RLSD
Not used
DTR/DSR
Not used
43
16
-->
H
B
DTR
Not used
DSR/DTR
Not used
34
18
<--
H
B
DTR
Not used
LL/DCD
Not used
44
16
-->
K
B
LT
Not used
DCD/LL
Not used
33
18
<--
K
B
LT
Not used
TxD/RxD+
TxD/RxD-
18
17
-->
-->
P
S
SD+
SD-
RxD/TxD+
RxD/TxD-
28
27
<--
<--
P
S
SD+
SD-
RxD/TxD+
RxD/TxD-
28
27
<--
<--
R
T
RD+
RD-
TxD/RxD+
TxD/RxD-
18
17
-->
-->
R
T
RD+
RD-
TxCE/TxC+
TxCE/TxC-
20
19
-->
-->
U
W
SCTE+
SCTE-
RxC/TxCE+
RxC/TxCE-
26
25
<--
<--
U
W
SCTE+
SCTE-
RxC/TxCE+
RxC/TxCE-
26
25
<--
<--
V
X
SCR+
SCR-
NIL/RxC+
NIL/RxC-
22
21
-->
-->
V
X
SCR+
SCR-
TxC/RxC+
TxC/RxC-
24
23
<--
<--
Y
AA
SCT+
SCT-
TxCE/TxC+
TxCE/TxC-
20
19
-->
-->
Y
AA
SCT+
SCT-
Mode 1
Ground
49
48
Shorting group Mode 1
Ground
49
48
Shorting group
Mode 0
Ground
Mode_DCE
50
51
52
Shorting group Mode 0
Ground
50
51
Shorting group
TxC/NIL
RxC/TxCE
RxC/TxD
Ground
53
54
55
56
Shorting group TxC/NIL
RxC/TxCE
RxC/TxD
Ground
53
54
55
56
Shorting group

Table  A-12: EIA-530 Adapter Cable Signals
FSIP End, HD 60-Position Plug DTE Cable1 Network End, DB-25 Plug
Signal (J1) Pin

Pin Signal (J2)
Shield ground 46 1 Shield ground
TxD/RxD+
TxD/RxD-
11
12
-->
-->
2
14
TxD+
TxD-
RxD/TxD+
RxD/TxD-
28
27
<--
<--
3
16
RxD+
RxD-
RTS/CTS+
RTS/CTS-
9
10
-->
-->
4
19
RTS+
RTS-
CTS/RTS+
CTS/RTS-
1
2
<--
<--
5
13
CTS+
CTS-
DSR/DTR+
DSR/DTR-
3
4
<--
<--
6
22
DSR+
DSR-
DCD/DCD+
DCD/DCD-
5
6
<--
<--
8
10
DCD+
DCD-
TxC/RxC+
TxC/RxC-
24
23
<--
<--
15
12
TxC+
TxC-
RxC/TxCE+
RxC/TxCE-
26
25
<--
<--
17
9
RxC+
RxC-
LL/DCD
Circuit ground
44
45
--> 18
7
LL
Circuit ground
DTR/DSR+
DTR/DSR-
7
8
-->
-->
20
23
DTR+
DTR-
TxCE/TxC+
TxCE/TxC-
13
14
-->
-->
24
11
TxCE+
TxCE-
Mode_1
Ground
Mode_2
49
48
47

Shorting group
Ground
Mode_DCE
51
52
Shorting group
Not used
Not used
15
16
7
7
Not used
Not used

1 For EIA-530, DCE mode is not available.

Table A-13 shows the signal pinouts for each type of E1-G.703/G.704 interface cable. All cables use a 15-pin D-shell (DB-15) connector at the FSIP end.


Table  A-13: E1-G.703/G.704 Adapter Cable Connector Pinouts
FSIP End Network End
DB-151 DB-15 Null Modem
DB-15
BNC Twinax
Pin Signal2 Pin Pin Signal Pin Signal
9 Tx tip 1 3 Tx tip J2-1 Tx
2 Tx ring 9 11 Tx shield J2-2 Tx
10 Tx shield 2 4 - J2 shield Tx shield
8 Rx tip 3 1 Rx tip J3-1 Rx
15 Rx ring 11 9 Rx shield J3-2 Rx
7 Rx shield 4 2 - J3 shield Rx shield

1 Any pins not described in this table are not connected.
2 Tx = transmit. Rx = receive.

HSSI Connector Signals

Two types of cables are available for use with the HIP: the HSSI interface cable used to connect the HIP HSSI port with an external DSU (and HSSI network) and a null modem cable, which allows you to connect two collocated routers back to back.

HSSI Interface Cable

The HSSI interface cable (Product Number CAB-HSI1) connects the HIP port with an external DSU. The cable comprises 25 twisted pairs and a 50-pin SCSI-II-type plug at each end. Although the HSSI cable is similar to a SCSI-II cable, it is not identical; you cannot substitute a SCSI-II cable for a HSSI interface cable. (See the following Caution.) Table A-14 lists the pin signals for the connector.

Caution Although the HIP connector and the HSSI interface cable are similar to SCSI-II format, the HSSI cable specification is more stringent than that for a SCSI-II. We cannot guarantee proper operation if a SCSI-II cable is used instead of an HSSI interface cable.

Table  A-14: HSSI Interface Cable Signals
Signal Name Pin No., + Side
(Router End)
Direction1 Pin No., - Side
(DSU End)
SG - Signal Ground 1

--

26
RT - Receive Timing 2

<--

27
CA - DCE Available 3

<--

28
RD - Receive Data Reserved 4

<--

29
LC - Loopback Circuit C 5

<--

30
ST - Send Timing 6

<--

31
SG - Signal Ground 7

--

32
TA - DTE Available 8

-->

33
TT - Terminal Timing 9

-->

34
LA - Loopback Circuit A 10

-->

35
SD - Send Data 11

-->

36
LB - Loopback Circuit B 12

-->

37
SG - Signal Ground 13

--

38
 5 - Ancillary to DCE 14-18

-->

39-43
SG - Signal Ground 19

--

44
 5 - Ancillary from DCE 20-24

<--

45-49
SG - Signal Ground 25

--

50

1 Router is + side (DTE). DSU is - side (DCE).

Null Modem Cable

The null modem cable (CAB-HNUL) can connect two routers directly back to back. The two routers must be in the same location and can be two Cisco 7000 series, two AGS+ routers, or one of each. A null modem connection allows you to verify the operation of the HSSI or to link the routers directly in order to build a larger node.

The null modem cable uses the same 50-pin connectors as the HSSI interface cable, but uses the pinouts listed in Table A-15. For null modem cable connection and configuration instructions, refer to the section "HSSI Connection Equipment" in the chapter "Preparing for Installation."


Table  A-15: HSSI Null Modem Cable Signals
Signal Name From Pins Direction To Pins Signal Name
Receive Timing 2, 27

-->

9, 34 Terminal Timing
DCE Available 3, 28

-->

8, 33 DTE Available
Received Date 4, 29

-->

11, 36 Send Data
Loopback C 5, 30

-->

10, 35 Loopback A
Send Timing 6, 31

-->

6, 31 Send Timing
DTE Available 8, 33

-->

3, 28 DCE Available
Terminal Timing 9, 34

-->

2, 27 Receive Timing
Loopback A 10, 35

-->

5, 30 Loopback C
Send Data 11, 36

-->

4, 29 Receive Data
Ground 1, 26,
7, 32,
13, 38,
19, 44,
25, 50

1, 26,
7, 32,
13, 38,
19, 44,
25, 50
Ground
Loopback (not connected) 12, 37

12, 37 Loopback (not connected)
Not used 14-18, 20-24, 39-43, 45-49

14-18, 20-24, 39-43, 45-49 Not used

MIP Interface Cable Pinouts

The MIP T1 interface cables have two, male, 15-pin DB connectors (one at each end) to connect the MIP with the external CSU. Table A-16 lists the pinouts for the null-modem T1 cable, and Table A-17 lists the pinouts for the straight-through T1 cable. Table A-18 lists the pinouts for the E1 interface cables.


Table  A-16: T1 Null-Modem Cable Signals
15-Pin DB Connector 15-Pin DB Connector
Signal Pin Pin Signal
Tx tip1 1 3 Rx tip
Rx tip2 3 1 Tx tip
Tx ring 9 11 Rx tip
Rx tip 11 9 Tx ring

1 Tx = transmit.
2 Rx = receive.

Table  A-17: T1 Straight-Through Cable Signals
15-Pin DB Connector 15-Pin DB Connector
Signal Pin Pin Signal
Tx tip1 1 1 Tx tip
Tx ring2 9 9 Tx ring
Rx tip 3 3 Rx tip
Rx tip 11 11 Rx tip

1 Tx = transmit.
2 Rx = receive.

Table  A-18: E1 Interface Cable Pinouts
MIP End Network End
DB-151 BNC DB-15 Twinax RJ-45
Pin Signal2 Signal Pin Signal Pin Signal Pin Signal
9 Tx tip Tx tip 1 Tx tip Tx-1 Tx tip 1 Tx tip
2 Tx ring Tx shield 9 Tx ring Tx-2 Tx ring 2 Tx ring
10 Tx shield - 2 Tx shield Shield Tx shield 3 Tx shield
8 Rx tip Rx tip 3 Rx tip Rx-1 Rx tip 4 Rx tip
15 Rx ring Rx shield 11 Rx ring Rx-2 Rx ring 5 Rx ring
7 Rx shield - 4 Rx shield Shield Rx shield 6 Rx shield

1 Any pins not described in this table are not connected.
2 Tx = transmit. Rx = receive.

1 &&Center&&Any pins not indicated are not used.

hometocprevnextglossaryfeedbacksearchhelp