Product Numbers: OC12/SRP-MM/SC-B (=), OC12/SRP-IR/SC-B (=), OC12/SRP-LR/SC-B (=)
This publication contains instructions for installing and configuring the 1OC-12/STM-4 SRP line card on a Cisco 12000 series Gigabit Switch Router (GSR).
This configuration note includes the following sections:
This section contains important information about additional documentation, Cisco IOS software configuration, safety, and technical support. This section also describes important operating considerations for your line card.
![]() |
Note You can access Cisco IOS software documentation and hardware installation and maintenance documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, and http://www-europe.cisco.com. If you are reading Cisco documentation on the World Wide Web, you can submit comments electronically. Click Feedback on the toolbar, and then select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments. |
The Cisco Documentation CD-ROM package provides comprehensive documentation on the entire Cisco product line. The CD-ROM package contains documents in both Adobe portable document format (PDF), viewable with Adobe Acrobat Reader, and hypertext markup language (HTML) files, viewable with a Web browser.
The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly; therefore, it might be more up to date than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription.
For hardware installation and maintenance information on the Cisco 12000 series routers, refer to the installation and configuration guide that shipped with your Cisco 12000 series router.
Also refer to the field-replaceable unit (FRU) publications that describe how to install, maintain, and replace router subsystems, such as cooling fans, power supplies, chassis backplanes, and so on.
The Cisco IOS software that runs on your router contains extensive features and functionality.
For Cisco IOS software configuration information and support, refer to the configuration and command reference publications in the Cisco IOS software configuration documentation set that corresponds to the Cisco IOS software release installed on your Cisco hardware. You can also refer to the Cisco IOS software release notes for the version of Cisco IOS software you are using on your router. Also refer to the online document, Dynamic Packet Transport (DPT) Feature Module for Cisco 12000 Series Routers.
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Refer to "Cisco Connection Online" section," for complete information on how to obtain support through CCO.
You can also contact Cisco Customer Service at 800 553-6387 or 408 526-7208 (U.S.). Customer Service hours are 5:00 a.m. to 6:00 p.m. Pacific time, Monday through Friday (excluding company holidays). You can also send e-mail to cs-rep@cisco.com.
You may also find useful information in the Cisco Information Packet that shipped with your router.
The following operating considerations apply to the 1OC-12/STM-4 SRP line card:
Before you begin the procedures in this publication, review the safety guidelines in this section to avoid injuring yourself or damaging the equipment.
For information on regulatory compliance and safety, refer to the Regulatory Compliance and Safety Information publication that shipped with your device. This publication contains important safety information that you must read and understand before attempting to install, remove, or modify any hardware in your Cisco 12000 series router.
Safety warnings appear throughout this publication in procedures that, if performed incorrectly, may harm you. A warning symbol precedes each warning statement. The following paragraph is an example of a safety warning. It identifies the warning symbol and associates it with a bodily injury hazard. The remaining paragraphs in this section are translations of the initial safety warning.
![]() |
Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device. |
Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen, kunt u het document Regulatory Compliance and Safety Information (Informatie over naleving van veiligheids- en andere voorschriften) raadplegen dat bij dit toestel is ingesloten.
Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta).
Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d'avertissements figurant dans cette publication, consultez le document Regulatory Compliance and Safety Information (Conformité aux règlements et consignes de sécurité) qui accompagne cet appareil.
Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Dokument Regulatory Compliance and Safety Information (Informationen zu behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät geliefert wurde.
Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nel documento Regulatory Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) che accompagna questo dispositivo.
Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i dokumentet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) som ble levert med denne enheten.
Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte o documento Regulatory Compliance and Safety Information (Informação de Segurança e Disposições Reguladoras) que acompanha este dispositivo.
¡Advertencia! Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo.
Varning! Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information (Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning.
Electrostatic discharge (ESD) damage, which can occur when electronic cards or components are improperly handled, results in complete or intermittent failures. The 1OC-12/STM-4 SRP line card consists of a printed circuit card that is fixed in a metal carrier. Electromagnetic interference (EMI) shielding and connectors are integral components of the carrier. Although the metal carrier helps to protect the board from ESD, use a preventive ESD strap whenever you are handling a line card.
Following are guidelines for preventing ESD damage:
![]() |
Caution For safety, periodically check the resistance value of the ESD strap. The measurement should be between 1 and 10 megohms. |
The Cisco 12000 series Gigabit Switch Routers provide high-speed, high-volume routing of packets and ATM cells. The Cisco 12000 series includes the following platforms, all sharing a similar architecture:
The GSR architecture offers the following features and capabilities in providing support to IP-based local-area networks (LANs) and wide-area networks (WANs):
In addition, the system allows for redundant, field-replaceable units (FRUs).
The 1OC-12/STM-4 SRP line card equips the Cisco series 12000 GSR with a total of two OC-12c fiber-optic SC duplex ports. The line card provides two duplex SC connections for either the single-mode or multimode version. The synchronous payload envelope (SPE) is concatenated, which increases efficiency by eliminating the need to partition the bandwidth. The 1OC-12/STM-4 SRP line card is slot independent.
The 1OC-12/STM-4 SRP line card allows networks to:
Figure 1 shows a high-level block diagram of the 1OC-12/STM-4 SRP line card.

Figure 2 shows front and rear views of the 1OC-12/STM-4 SRP line card for the single-mode and multimode versions.
Each line card has the following main components:
The multimode transceiver version provides two full-duplex, 622 megabits per second (Mbps), 1310-nanometer (nm), LED-based, SONET/SDH-compliant interfaces, with a power rating of -20 to -14 decibles per milliwatt (dBm) transmitting and -26 to -14 dBm receiving. The multimode transceiver operates at a distance of up to (500 meters or 1640 feet). The actual distance in any given case depends on the quality of the fiber attached to the transceiver.
The single-mode intermediate-reach transceiver version provides two full-duplex, 622-Mbps, 1310-nm, laser-based, SONET/SDH-compliant interfaces, with a power rating of -15 to -8 dBm transmitting and -28 to -8 dBm receiving. The single-mode intermediate-reach transceiver operates at a distance of up to 15 kilometers (km).
The single-mode long-reach transceiver version provides two full-duplex, 622-Mbps, 1310-nm, laser-based, SONET/SDH-compliant interfaces, with a power rating of -3 to 2 dBm transmitting and -28 to -8 dBm receiving. The single-mode long-reach transceiver operates at a distance of up to 40 km. The actual distance in any given case depends on the quality of the fiber attached to the transceiver. The single-mode interfaces meet both IEC 825 and CDRH Class I safety standards.
The 1 megabyte (MB) burst buffer prevents packets from being dropped when there are instantaneous increases in the number of back-to-back small packets being transmitted at OC-12/STM4 line rates. Burst buffers provide high throughput and smooth out the arriving packet burst for the Layer 3 switch processor.
Each line card has two silicon queuing engines: receive (Rx) and transmit (Tx). The receive engine moves packets from the burst buffer to the switch fabric, and the transmit engine moves packets from the switch fabric to the transmit interface.
When an incoming IP packet is clocked into the silicon queuing engine, the silicon queuing engine verifies the packet's integrity by checking the cyclic redundancy check (CRC) value, transfers the IP packet to buffer memory, then conveys the location of the IP to the Layer 3 switching accelerator. The forwarding processor then instructs the silicon queuing engine on where to place the IP packet within the virtual output queue.
Each virtual output queue represents a line card. This placement of the IP packets in a virtual output queue is based on the decision that is made by the forwarding processor. There is one virtual output queue for each line card, plus a dedicated virtual output queue for multicast service.
The transmit silicon queuing engine moves the packet from the switch fabric to the transmit buffer, then to the transmit interface.
The silicon queuing engine controls the placement of IP packets in buffer memory, as well as the removal from buffer memory. The default packet buffer memory is 32 MB, which includes 16 MB of receive buffers and 16 MB of transmit buffers. The buffer memory can increase to 64 MB of receive buffers and 64 MB of transmit buffers. The buffers can support delays comparable to the longest round-trip delays measured on the Internet at OC-12 line rates.
The Layer 3 switching accelerator assists the forwarding processor. It is a specially designed, application-specific integrated circuit (ASIC) that optimizes access to the Layer 3 information within each packet. An ASIC is used to execute this access process as rapidly as possible.
A forwarding processor makes forwarding decisions, based on the information in the Cisco Express Forwarding (CEF) table and the Layer 3 information in the packet. The Gigabit Route Processor (GRP) constantly updates information in the forwarding table, based on the latest information in the routing table. The forwarding processor is an R5000 RISC processor operating at 250 MHz.
Once it makes the forwarding decision, the forwarding processor notifies the silicon queuing engine, which places the packet in the proper queue.
This partitioning between the Layer 3 switching accelerator and the forwarding processor blends the high throughput of hardware-accelerated forwarding with the flexibility of software-based routing.
The switch fabric interface is the same 5.0-Gigabits per second (Gbps), full-duplex data path to the switching fabric that the GRP uses. Once a packet is in the proper queue, the switch fabric interface issues a request to the master clock scheduler on the clock and scheduler card (CSC). The scheduler grants the request and transfers the packet across the switching fabric.
A maintenance bus (MBus) module on the line card responds to requests from the master MBus module on the GRP. The line card MBus module can report temperature and voltage information to the master MBus module. In addition, the MBus module on the line card contains the ID-EEPROM, which stores the serial number, hardware revision level, and other information about the card.
Each line card maintains Cisco Express Forwarding (CEF) memory tables. These tables, derived from routing tables maintained by the GRP, are used by the line card processor to make forwarding decisions. Large networks may require more dynamic rapid access memeory (DRAM) to support large CEF tables. For information on adding memory to a line card, see the publication Cisco 12000 series Gigabit Switch Router Memory Replacement Instructions.
This section provides information to help you prepare to install and configure the 1OC-12/STM-4 SRP line card and contains safety and ESD-prevention guidelines. The following sections describe prerequisites and preparation information:
You need the following tools and parts on the list to remove and replace a 1OC-12/STM-4 SRP line card:
![]() |
Note If you need additional equipment, contact your service representative for ordering information. |
We recommend that you do the following before beginning any of the procedures in this publication:
The 1OC-12/STM-4 SRP line card is compatible with any Cisco 12000 series router that is operating with the Cisco IOS Release 11.2(18) GS3 or a later 11.2 GS3 release. If the screen output indicates that the system software is running a version earlier than Cisco IOS Release 11.2(18), check the contents of Flash memory to determine whether the required images are available on your system.
The 1OC-12/STM-4 SRP line card is also compatible with the Cisco IOS Release 12.0(11)S GS2 or a later 12.0S GS2 release.
The show flash command displays a list of all files stored in Flash memory. If you do not have the correct software version, contact Cisco Customer Service.
The show version, show diag, and show hardware commands display the current hardware configuration of the router, including the system software version that is currently loaded and running. For complete descriptions of show commands, refer to the Configuration Fundamentals Configuration Guide and Configuration Fundamentals Command Reference publications, which are available on the Documentation CD-ROM, Cisco Connection Online, or as printed copies.
In the following example of the show version command, the Cisco system software that is running,
Release 11.2(18) GS3, is displayed in italics.
Router# show version Cisco Internetwork Operating System Software IOS (tm) GS Software (GSR-P-M), Version 11.2(18)GS3 Copyright (c) 1986-1999 by cisco Systems, Inc. Compiled Fri 15-Oct-99 16:59 by htseng Image text-base: 0x60010AF0, data-base: 0x608A0000 ROM: System Bootstrap, Version 11.2(9)GS5, [tamb 176]) BOOTFLASH: GS Software (GSR-BOOT-M), Version 11.2(18)GS3 Router uptime is 42 minutes System returned to ROM by reload at 15:55:51 UTC Wed May 19 1999 System image file is "muck/gsr-p-mz.112-18.GS3", booted via tftp from 223.255.24 cisco 12012/GRP (R5000) processor (revision 0x01) with 131136K bytes of memory. R5000 processor, Implementation 35, Revision 2.1 (512KB Level 2 Cache) Last reset from power-on 4 Route Processor Cards 2 Clock Scheduler Cards 3 Switch Fabric Cards 2 four-port OC3 POS controllers (8 POS). 1 one-port OC12 SONET based SRP controller (1 SRP). 1 Ethernet/IEEE 802.3 interface(s) 8 Packet over SONET network interface(s) 507K bytes of non-volatile configuration memory. 20480K bytes of Flash PCMCIA card at slot 0 (Sector size 128K). 20480K bytes of Flash PCMCIA card at slot 1 (Sector size 128K). 8192K bytes of Flash internal SIMM (Sector size 256K). Configuration register is 0x0 Router#
The show diag command displays the GRP microcode version and the line card microcode version (shown in italics in the following example):
Router# show diag 2
SLOT 2 (RP/LC 2 ): 1 Port SONET based SRP OC-12c/STM-4 Single Mode
MAIN: type 53, 800-4202-02 rev 71 dev 16777215
HW config: 0x00 SW key: FF-FF-FF
PCA: 73-3237-05 rev 72 ver 5
HW version 2.1 S/N CAB03363Z27
MBUS: MBUS Agent (1) 73-5189-07 rev A0 dev 0
HW version 1.2 S/N CAB03363Z27
Test hist: 0xFF RMA#: FF-FF-FF RMA hist: 0xFF
DIAG: Test count: 0xFFFFFFFF Test results: 0xFFFFFFFF
MBUS Agent Software version 01.36 (RAM) (ROM version is 01.33)
Using CAN Bus A
ROM Monitor version 0E.00
Fabric Downloader version used 13.04 (ROM version is 10.03)
Primary clock is CSC 1
Board is analyzed
Board State is Line Card Enabled (IOS RUN )
Insertion time: 00:00:15 (00:43:40 ago)
DRAM size: 134217728 bytes
FrFab SDRAM size: 134217728 bytes, SDRAM pagesize: 8192 bytes
ToFab SDRAM size: 134217728 bytes, SDRAM pagesize: 8192 bytes
0 crashes since restart
Router#
To ensure compatibility with the software your 1OC-12/STM-4 SRP line card should have a hardware revision level of 73-5189-01 Rev. A0 for single-mode intermediate reach, 73-5190-01
Rev. A0 for single-mode long reach, or 73-5188-01 Rev. A0 for multimode. The hardware revision number is printed on a label that is affixed to the component side of the card. You can also display the hardware revision number using the show diag and show hardware commands. (See "Software Version Requirements.")
The SONET specification for fiber-optic transmission defines two types of fiber: single-mode and multimode. Signals can travel farther through single-mode fiber than through multimode fiber.
The maximum distance for single-mode installations is determined by the amount of light loss in the fiber path. Good quality single-mode intermediate-reach fiber with very few splices can carry an OC-12/STM-4 signal about 9 miles (15 km). Single-mode long-reach fiber can carry the OC-12/STM-4 signal about 25 miles (40 km). Multimode fiber can carry the signal up to 1640 feet (500 meters). If your environment requires the signal to travel close to the typical maximum distance (as listed in Table 1), use an optical time domain reflectometer (OTDR) to measure the power loss.
| Transceiver | Power Budget | Transmit Power | Receive Power | Typical Maximum Distance |
|---|---|---|---|---|
Multimode | 6 dB | -26 to -14 dBm | 1640 feet (500 meters) | |
Single-mode | 12 dB | -15 to -8 dBm at 1270 to 1380 nm | -28 to -8 dBm | 9 miles (15 km) |
Single-mode | 25 dB | -3 to 2 dBm at 1270 to 1380 nm | -28 to -8 dBm | 25 miles (40 km) |
| 1dBm = decibels per milliwatt 2nm = nanometer |
1OC-12/STM-4 SRP line cards are available with the memory options described in Table 2 and Table 3. Refer to the Cisco 12000 Series Gigabit Switch Router Memory Replacement Instructions publication for installation procedures if you are upgrading or replacing line card memory.
| Product Option | Description |
|---|---|
MEM-DFT-GRP/LC-64 | 64 MB (default) |
MEM-GRP/LC-128 | 128 MB (orderable upgrade) |
MEM-GRP/LC-256 | 256 MB (orderable upgrade) |
Table 3 lists the available configurations and associated product numbers of SDRAM DIMMs for upgrading transmit and receive buffer memory on Cisco 12000 series GSR line cards.
| Packet Memory Size | DIMM Modules1 | Cisco Product Number |
64 MB | 2 32-MB DIMMs | MEM-LC-PKT-642 |
128 MB | 2 64-MB DIMMs | MEM-LC-PKT-1283 |
This section describes the line card slot locations in the following Cisco 12000 series routers:
Before installing your line card into the router, verify that a line card slot is available.
The Cisco 12016 GSR chassis has three integral card cages: the upper card cage, the lower card cage, and the switch fabric card cage. You can install line cards in the upper or lower card cage.
The upper card cage has eight user-configurable slots that support the following types of cards in the quantities indicated:
![]() |
Note If the router is equipped with an optional, redundant GRP, it must be installed in the far left slot of the lower card cage (slot 8). If the router is not equipped with an optional, redundant GRP, a line card can be installed in slot 8 of the lower card cage. |
The lower card cage in the Cisco 12016 GSR has eight user-configurable slots, numbered 8 through 15, that support the following types of cards in the quantities indicated:
![]() |
Note The lower card cage is an inverted, or head-down, copy of the upper card cage, meaning cards are installed the same way they are installed in the upper card cage, but in an inverted or head-down orientation. |
Figure 3 shows the location of the line card slots in the Cisco 12016 GSR.

Figure 4 shows the location of the line card slots in the Cisco 12012 router. The Cisco 12012 router has 12 user-configurable slots that support a combination of line cards and a Gigabit Route Processor (GRP). Line cards are installed in the upper card cage. The right-most slot in the upper card cage supports a non-configurable alarm card. Although you can insert the GRP into any line card slot, Figure 4 shows the GRP in slot 0, which is what Cisco recommends.

Figure 5 shows the location of the line card slots in the Cisco 12008 router. The upper card cage contains ten slots that accommodate the following types of cards in the quantities indicated:

Use a single-mode, intermediate-mode or multimode fiber-optic interface cable to connect your Cisco 12000 series router to another router or switch. In general, multimode cables are gray or orange, and single-mode cables are yellow.
![]() |
Note Single-mode, intermediate mode, and multimode fiber-optic cables are available from the following cable vendors: AMP, Anixter, AT&T, Red-Hawk, and Siemens. These cables are not available from Cisco Systems. |
For SONET/SDH single-mode and multimode fiber-optic connections, use one duplex SC-type connector (see Figure 6) or two Simplex SC-type connectors (see Figure 7).


Attach either one duplex fiber cable or two simplex fiber cables between the line card and the device to which the line card is connected. Observe the receive (Rx) and transmit (Tx) cable relationship shown in Figure 8.

![]() |
Warning Because invisible radiation may be emitted from the aperture of the port when no fiber cable is connected, avoid exposure to radiation and do not stare into open apertures. |
![]() |
Warning Class 1 laser product (single-mode intermediate-reach). |
![]() |
Warning Class 1 laser product (single-mode long-reach). |
![]() |
Warning Class 1 LED product (multimode). |
![]() |
Note The fiber-optic connectors must be free of dust, oil, and other contaminants. Carefully clean the fiber-optic connectors using a fiber cleaning kit. |
The cable-management system in the Cisco 12000 series router organizes the interface cables entering and exiting the system, keeping them out of the way and free of sharp bends. Excessive bending in an interface cable can degrade performance and possibly harm the cable.
The cable-management system consists of two separate components:
Figure 9 shows a cable-management bracket that can be mounted on a Cisco 12012 GSR.

Figure 10 shows the cable-management tray and a line card cable-management bracket on a Cisco 12012 chassis. The cable-management tray on the Cisco 12008 is similar in form and function to the tray on the Cisco 12012.

The Cisco 12016 has a cable-management tray for the upper card cage that is positioned above the upper line card slots, and a cable-management tray for the lower card cage that is positioned below the lower line card slots. In addition, there are vertical cable troughs on either side of the card cages that keep the cables organized and secured. See Figure 11.

This section describes the procedures for installing or replacing a 1OC-12/STM-4 SRP line card and contains the following procedures:
(See the following section, "Guidelines for Line Card Removal and Installation," before removing a line card while power to the system is on.)
![]() |
Note The procedures in the following sections use illustrations of a Cisco 12012 GSR to support the descriptions of removing and installing line cards. Although the card cages of the Cisco 12000 series routers differ in the number of card slots, the designated use of slots and the process of removing and installing a line card are basically the same. Therefore, separate procedures and illustrations for the Cisco 12016 GSR and Cisco 12008 GSR are not included in this publication. |
![]() |
Note Before you remove a line card, Cisco recommends that you shut down (disable) the interfaces to prevent anomalies when you reinstall the new or reconfigured line card. When you shut down an interface, it is designated administratively down in the show command display. |
![]() |
Caution To avoid erroneous failure messages, remove or insert only one line card at a time. Also, after inserting or removing a line card, allow at least 15 seconds before removing or inserting another line card, so that the system can reinitialize and note the current configuration of all interfaces. |
You can remove and replace line cards while the system is operating; you do not need to reconfigure the software or reset the system power. This functionality allows you to add, remove, or replace line cards with the system online, which provides a method that is seamless to end users on the network, maintains all routing information, and ensures session preservation.
When you reinstall a line card, the system automatically downloads the necessary software from the GRP. After that, the system brings online only those interfaces that match the current configuration and that were previously configured as up. You must configure all others with the configure command. (For 1OC-12/STM-4 SRP line card configuration information, refer to the section "Configuring Interfaces on the 1OC-12/STM-4 SRP Line Card.")
![]() |
Caution The system can indicate a hardware failure if you do not follow proper procedures. Remove or insert only one line card at a time. Allow at least 15 seconds for the system to complete the preceding tasks before removing or inserting another line card. |
Each line card has two ejector levers that allow you to release the card from its backplane connector when you are removing the line card, and to firmly seat the line card in its backplane connector when you are installing the line card. The ejector levers align and seat the card connectors in the backplane.
When you remove a line card, always use the ejector levers to ensure that the line card connector pins disconnect from the backplane. Any line card that is only partially connected to the backplane can halt the system.
Similarly, when you install a line card, always use the ejector levers to ensure that the line card is correctly aligned with the backplane connector, the card connector pins make contact with the backplane in the correct order, and the line card is fully seated in the backplane. A card that is only partially seated in the backplane can cause the system to hang, and subsequently crash.
Use Figure 12 as a reference for the procedures in this section.

![]() |
Note Before you remove a line card, Cisco recommends that you shut down (disable) the interfaces to prevent anomalies when you reinstall the new or reconfigured line card. When you shut down an interface, it is designated administratively down in the show command display. |
To remove line card interface cables perform the following steps:
Step 2 Disconnect and remove the line card interface cables and line card cable-management bracket (See Figure 12.)
a. Disconnect the interface cable connectors from the line card interface ports.
b. Use a Phillips screwdriver to loosen the captive installation screws at the ends of the line card cable-management bracket.
c. Detach the line card cable-management bracket from the line card and set it aside.
![]() |
Note Do not remove the interface cables from the line card cable-management bracket. The bracket is equipped with a small hook on one end for hanging the bracket and cables from the cable-management tray or bracket on the chassis. |
If you are replacing a failed line card, remove the existing card first, and then install the new line card in the same slot. The Cisco 12000 series GSR supports online line card insertion and removal, which means that you can remove and replace line cards while the system remains powered up.
![]() |
Note Before you remove a line card, Cisco recommends that you use the shutdown command to disable the interfaces to prevent anomalies when you reinstall the new or reconfigured line card. When you shut down an interface, it is designated as administratively down in the show command display. |
To remove a line card, use Figure 13 and a reference and perform the following steps:
![]() |
Caution When you remove a line card, always use the ejector levers to ensure that the card connector pins disconnect from the backplane. Any card that is only partially connected to the backplane can halt the system. |
Step 2 Simultaneously pivot the ejector levers away from each other to release the line card from the backplane connector. (See Figure 13b.)
Step 3 Grasp the ejector levers and pull the line card half-way out of the slot.
Step 4 Grasp the line card faceplate with one hand and pull the line card straight out of the slot, keeping your other hand under the line card to guide it. (See Figure 13c.) Avoid touching the line card printed circuit board, components, or any connector pins.
Step 5 Place the removed line card on an antistatic mat or foam pad, or place it in an antistatic bag if you plan to return it to the factory.
Step 6 If the line card slot is to remain empty, install a line card blank (Cisco product number 800-03004-01) to keep dust out of the chassis and to maintain proper airflow through the line card compartment. Secure the line card blank to the chassis by tightening its captive screws.
A line card slides into any available line card slot and connects directly to the backplane.
If you install a new line card, you must first remove the line card blank from the available slot. Refer to the procedures in the section "Removing a Line Card," earlier in this publication.
![]() |
Note You can install the line card in any available line card slot. Although you can insert the GRP into any line card slot, Cisco recommends placing the GRP in slot 0. For information on line card slot locations, refer to the section "Cisco 12000 Series Line Card Slot Locations," earlier in this publication. |
![]() |
Caution The system can indicate a hardware failure if you do not follow proper procedures. Remove or insert only one line card at a time. Allow at least 15 seconds for the system to complete the preceding tasks before removing or inserting another line card. |
Use the following procedure to install a line card:
Step 2 Attach an ESD wrist strap to your wrist and to the ESD connection socket on the chassis or to a bare metal surface on the chassis or frame.
Step 3 Choose an available line card slot for the line card, and verify that the line card's interface cable is long enough for you to connect the line card with any external equipment.
![]() |
Caution To prevent ESD damage, handle line cards by the card carrier edges only. |
Step 4 Grasp the faceplate of the line card with one hand and place your other hand under the card carrier to support the weight of the card; position the card for insertion into the card cage slot. Avoid touching the line card printed circuit board, components, or any connector pins.
Step 5 Carefully slide the line card into the slot until the ejector levers make contact with the edges of the card cage, then stop. Make sure the ejector lever hooks catch the lip of the card cage. (See Figure 14.)

![]() |
Caution When you install a line card, always use the ejector levers to ensure that the card is correctly aligned with the backplane connector, the card connector pins make contact with the backplane in the correct order, and the card is fully seated in the backplane. A card that is only partially seated in the backplane can cause the system to hang and subsequently crash. |
Step 6 Simultaneously pivot both ejector levers toward each other until they are perpendicular to the line card faceplate. This action firmly seats the card in the backplane.
Step 7 Use a Phillips screwdriver to tighten the captive screw on each end of the line card faceplate to ensure proper EMI shielding and to prevent the line card from becoming partially dislodged from the backplane. (These screws must be tightened to meet EMI specifications.)
![]() |
Caution To ensure adequate space for additional line cards, always tighten the captive installation screws on each newly installed line card before you insert any additional line cards. These screws also prevent accidental removal and provide proper grounding and EMI shielding for the system. |
Step 8 Reinstall the line card cable-management bracket (see Figure 12, previously shown).
a. Unhook the line card cable-management bracket from the chassis cable-management tray or bracket.
b. Position the line card cable-management bracket over the front of the line card faceplate.
c. Insert and tighten the captive screw at each end of the line card cable-management bracket to secure the bracket to the line card.
Step 9 Plug the interface cable connectors into their original ports on the line card faceplate.
This section contains the following procedures:
The following procedures assume that you have installed a new line card in the router. You must also install a line card cable-management bracket on the line card.
To install a line card cable-management bracket on a line card, perform the following steps:
Step 2 Attach the line card cable-management bracket to the line card as follows:
a. Position the line card cable-management bracket over the front of the line card faceplate.
b. Insert and tighten the captive screw at each end of the line card cable-management bracket to secure the bracket to the line card.
Step 3 Starting with the bottom port on the line card (see Figure 15a), connect each interface cable to the intended port.
Step 4 Carefully press the interface cable into the cable clip on the end of the cable standoff, as shown in Figure 15b. Avoid any kinks or sharp bends in the cable. (Excessive bending in an interface cable can degrade performance.)
Step 5 Proceeding upward, carefully press the interface cable into the cable-routing clips along the base of the line card cable-management bracket, as shown in Figure 15c.
Step 6 Repeat Step 3 through Step 5 for all of the interface cables on the line card ports.
To remove the interface cables from a line card cable-management bracket and remove the cable-management bracket from a line card, perform the following steps:
Step 2 On the site log, note the current interface cable connections to the ports on each line card.
Step 3 Starting with the interface cable for the bottom port on the line card (for cards with multiple ports), disconnect the cable from the line card port (See Figure 16a.)
Step 4 Proceeding upward, remove the interface cable from the cable clip on the end of the cable standoff (See Figure 16b.)
Step 5 Remove the interface cable from the cable-routing clips along the base of the line card cable-management bracket (See Figure 16c.)
Repeat Step 3 through Step 5 for any other interface cables on the line card ports, then proceed to Step 6.
Step 6 Loosen the captive installation screw at each end of the line card cable-management bracket and remove the bracket from the line card.

After you have installed the line card and connected the interface cables, check the LEDs on the faceplate to verify that the 1OC-12/STM-4 SRP line card is working properly. Each 1OC-12/STM-4 SRP line card provides the following types of LEDs for monitoring the operating status of the line card:
During a typical line card boot process, the following events occur:
To verify that the line card is working properly, perform the following operational checks:
The 1OC-12/STM-4 SRP line card has seven LEDs (See Figure 17):

The 1OC-12/STM-4 SRP line card has two, 4-digit alphanumeric LED displays at one end of the faceplate, near the ejector lever, that display messages telling you the state of the card. In general, the LEDs do not turn on until the GRP recognizes and powers up the card. It is normal for a message displayed as part of a sequence or process to appear too briefly to read.
As it boots, the line card displays a sequence of messages that is similar to that shown in Table 4.
| LED Display1 | Meaning | Source |
|---|---|---|
MROM | The MBus microcode begins to execute; nnnn is the microcode version number. For example, microcode version 1.33 or above would display as 01172. This display might not be visible because it occurs for only a brief time. | MBus controller |
LMEM | Low memory on the line card is being tested. | Line card ROM monitor |
LROM | Low memory test has been completed. | Line card ROM monitor |
BSS | Main memory is being initialized. | Line card ROM monitor |
RST | The contents of the reset reason register are being saved. | Line card ROM monitor |
IO | Reset I/O register is being accessed. | Line card ROM monitor |
EXPT | Interrupt handlers are being initialized. | Line card ROM monitor |
TLB | TLB is being initialized. | Line card ROM monitor |
CACH | CPU data and instruction cache is being initialized. | Line card ROM monitor |
MEM | The size of main memory on the line card is being discovered. | Line card ROM monitor |
LROM | The ROM is ready for the download attempt. | Line card ROM monitor |
ROMI | The ROM image is being loaded into line card memory. | GRP IOS software |
FABL | The line card is waiting for the loading of the fabric downloader.3 | GRP IOS software |
FABL | The fabric downloader is being loaded into line card memory. | GRP IOS software |
FABL | The fabric downloader is being launched. | GRP IOS software |
FABL | The fabric downloader has been launched and is running. | GRP IOS software |
IOS | The Cisco IOS software is being downloaded into line card memory. | GRP IOS software |
IOS | The Cisco IOS software is being launched. | GRP IOS software |
IOS | The Cisco IOS software is running. | GRP IOS software |
IOS | The line card is enabled and ready for use. | GRP IOS software |
| 1The LED sequence shown in Table 4 might occur too quickly for you to read; therefore, this sequence is provided in this tabular form as a baseline for how the line cards should function at startup. 2The version of MBus microcode running on your system might be different. 3The fabric downloader loads the Cisco IOS software image onto the line card. |
Table 5 lists other messages displayed on the line card alphanumeric LED displays.
| LED Display | Meaning | Source |
|---|---|---|
MRAM | The MBus microcode begins to execute; nnnn is the microcode version number. For example, microcode version 1.17 would display as 01171. This display might not be visible because it occurs for only a brief time. | MBus controller |
MAL | Card malfunction. | GRP |
PWR | Card not powered. | GRP |
PWR | Card powered. | GRP |
IN | In reset. | GRP |
RSET | Reset complete. | GRP |
MBUS | MBus agent downloading. | GRP |
MBUS | MBus agent download complete. | GRP |
ROMI | Getting ROM images. | GRP |
ROMI | Acquisition of ROM image complete. | GRP |
CLOK | Waiting for slot clock configuration. | GRP |
CLOK | Slot clock configuration done. | GRP |
FABL | Loading fabric downloader2 complete. | GRP |
FABI | Waiting for fabric initialization to complete. | GRP |
IOS | Downloading of Cisco IOS software is complete. | GRP |
BMA | Cisco IOS software BMA error. | GRP |
FIA | Cisco IOS fabric interface ASIC configuration error. | GRP |
CARV | Buffer carving failure. | GRP |
DUMP | Line card requesting a core dump. | GRP |
DUMP | Line card dumping core. | GRP |
DUMP | Line card core dump complete. | GRP |
DIAG | Diagnostic mode. | GRP |
DIAG | Downloading field diagnostics. | GRP |
DIAG | Launching field diagnostics. | GRP |
POST | Launching power-on self-test (POST). | GRP |
UNKN | Unknown state. | GRP |
| 1The version of MBus microcode running on your system might be different. 2The fabric downloader loads the Cisco IOS software image onto the line card. |
There are three LEDs next to each 1OC-12/STM-4 SRP line card port that signal the status of the port. Table 6 provides an explanation of the Active, Carrier, and Rx Pkt LEDs.
| LED State | Explanation | ||
| Active | Carrier | Rx Pkt | |
On | On | Off | Line card is up, but no packets received by line card. |
On | On | On | Line card is functioning normally and receiving packets. |
Off | On | Off | Line card is in wrap state. |
Off | Off | Flashing | Data is being transmitted or received. |
The status LEDs on the line card might not go on until you have configured the line card interfaces (or enabled them, if they were shut down). To verify correct operation of each interface, complete the configuration procedures for the line card see "Configuring Interfaces on the 1OC-12/STM-4 SRP Line Card" section."
The pass-through LED is located between the status LEDs and the alphanumeric LEDs. The pass-through LED indicates whether or not a fiber failure has occurred. Table 7 explains pass-through LED states.
| LED State | Explanation |
Orange | Packets are passing through transparently. |
Off | Line card is operating in normal mode. |
If the Active LED on a line card does not come on, verify the following conditions:
To verify that the line card is connected correctly, perform the following procedure:
Step 2 When the reinitialization is complete, verify that the Active LED on the 1OC-12/STM-4 SRP line card is on and remains on. If the LED stays on, proceed to Step 5. If the Active LED does not stay on, proceed to the next step.
Step 3 If the active LED on the 1OC-12/STM-4 SRP line card fails to go on, determine if the
board connector is fully seated in the backplane. Loosen the captive installation screws and firmly pivot the ejector levers toward each other until both are perpendicular to the 1OC-12/STM-4 SRP line card faceplate. Tighten the captive installation screws.
After the system reinitializes the interfaces, the Active LED on the 1OC-12/STM-4 SRP line card should go on. If the Active LED goes on, proceed to Step 5. If the active LED does not go on, proceed to the next step.
Step 4 If the Active LED still fails to go on, remove the 1OC-12/STM-4 SRP line card and try installing it in another available line card slot.
Step 5 Use the show interface command to verify the status of the interface. (If the interface is not configured, you must use the procedures in the section "Configuring Interfaces on the 1OC-12/STM-4 SRP Line Card" section.")
If an error message displays on the console terminal, refer to the appropriate reference publication for error message definitions. If you experience other problems that you are unable to solve, contact a service representative for assistance.
For more information on troubleshooting and diagnostics, consult the Installation and Configuration Guide that came with your Cisco 12000 series router.
You can create a ring by connecting the fiber-optic cables to 1OC-12/STM-4 SRP line cards that are installed in routers on your network. Follow these steps to create a four-node DPT ring:
Step 2 To add nodes to the ring, connect the cables observing the receive (Rx) and transmit (Tx) cabling relationship, which means that an Rx port on one 1OC-12/STM-4 SRP line card must be connected to a Tx port on the next SRP line card. The labels under the fiber connectors identify side A, Tx and Rx, and side B, Tx and Rx. (See Figure 18).

Use Figure 19 and Table 8 to make the cable connections for a four-node ring.
Table 8 lists the cable connections for a 4-node ring.
| Cable Connections | |
|---|---|
| From Node / Connector | To Node / Connector |
Node 1 / Tx side B | Node 2 / Rx side A |
Node 2 / Tx side B | Node 3 / Rx side A |
Node 3 / Tx side B | Node 4 / Rx side A |
Node 4 / Tx side B | Node 1 / Rx side A |
Node 1 / Tx side A | Node 4 / Rx side B |
Node 4 / Tx side A | Node 3 / Rx side B |
Node 3 / Tx side A | Node 2 / Rx side B |
Node 2 / Tx side A | Node 1 / Rx side B |
This section explains how to configure the 1OC-12/STM-4 SRP line card and contains the following procedures:
The command line interface (CLI) is provided to configure and display parameters for both the DPT and the SONET/SDH framer.
After you verify that the new 1OC-12/STM-4 SRP line card is installed correctly (the Active LED goes on), use the configure command to configure the new interface. Be prepared with the information you will need, such as the interface IP address.
The following procedure is for creating a basic configuration---enabling an interface and specifying IP routing. You might also need to enter other configuration commands, depending on the requirements of your system configuration. For descriptions of configuration commands and the configuration options available, refer to the appropriate software publications listed in the "Important Information" section.
A Cisco 12000 series router identifies an interface address by its line card slot number and port number, in the format slot/port. For example, the slot/port address of an interface on a
1OC-12/STM-4 SRP line card installed in line card slot 1 is 1/0. Even though the card contains only one port, you must use the slot/port notation.
Before using the configure command, you must enter the privileged EXEC command mode by using the enable command. The system will prompt you for a password if one is set.
Table 9 shows the default configuration values of an enabled 1OC-12/STM-4 SRP line card. For more information, see "1OC-12/STM-4 SRP Line Card Configuration Examples" section."
| Parameter | Configuration Command | Default Value |
|---|---|---|
Cisco Discovery Protocol (CDP) | [no] cdp enable | cdp enable |
Framing | srp framing {sdh | sonet} [a | b] | SONET OC-12c |
Bandwidth | [no] bandwidth kbps | 622000 kbps |
SONET overhead | srp flag {c2 | j0} value [a | b] | c2 set to 0x16; |
Clock source | srp clock-source {internal | line} [a | b] | srp clock-source internal |
Use the following procedures to configure the 1OC-12/STM-4 SRP line card. Press the Return key after each configuration step, unless otherwise noted.
Router# show version Router#
For an example of output from the show version command, see "Using show Commands to Check System Status" section" later in this publication.
Step 2 Check the status of each port by entering the show interface command:
Router# show interface Router#
For an example of output from the show interface command, see "Using show Commands to Check System Status" section" later in this publication.
Step 3 Enter configuration mode and specify that the console terminal will be the source of the configuration commands:
Router# configure terminal Router#
Step 4 Enable IP routing by entering the ip routing command:
Router(config)# ip routing Router(config)#
Step 5 At the prompt, specify the new interface to configure by entering the interface command, followed by the type (srp) and slot/port (line card slot number and port number). The example that follows is for a 1OC-12/STM-4 SRP line card in chassis slot 1:
Router(config)# interface srp 1/0 Router(config)#
Step 6 Assign an IP address and subnet mask to the interface with the ip address configuration command, as in the following example:
Router(config-if)# ip address 10.1.2.3 255.0.0.0 Router(config-if)
Step 7 The MAC address is configured by default. However, you can overwrite the MAC burn-in address as follows:
Router(config-if)# mac 1000.0000.1111 Router(config-if)
Step 8 Verify that the default value for the clock source is correct. The default setting is clock source internal.
Router(config-if)# srp clock-source line a Router(config-if)
When two Cisco 12000 series routers are connected back-to-back, or are connected over dark fiber, where no external clocking is available, set the clock source on each device to internal. If a router is connected to a SONET/SDH ADM, set the clock-source on each device to line.
Step 9 Change the shutdown state to up and enable the interface:
Router(config-if)# no shutdown Router(config-if)
The no shutdown command passes an enable command to the 1OC-12/STM-4 SRP line card. It also causes the line card to configure itself automatically, based on the previous configuration commands sent.
![]() |
Note The 1OC-12/STM-4 SRP line card cable is connected to both a Cisco 12000 series device and another device---either a high-end router or switch. Step 10 to Step 12 apply to both the Cisco 12000 series device and the remote device. |
Step 10 Turn off the Cisco Discovery Protocol (CDP):
Router(config-if)# no cdp enable Router(config-if)
Cisco 12000 series routers do not require CDP.
Step 11 Add any other configuration commands required to enable routing protocols and adjust the interface characteristics.
Step 12 When you have included all of the configuration commands to complete the configuration, enter ^Z (press the Control key while you press Z) to exit configuration mode.
Step 13 Write the new configuration to memory:
Router# copy running-config startup-config Router#
The system displays an OK message when the configuration has been stored.
After you have completed your configuration, you can check it using show commands. For an explanation of show commands, see the section "Using show Commands to Check System Status" section.
This section explains how to use SRP IPS command options that will insert or override automatic or user-configured IPS modes:
![]() |
Note Before any physical manipulation to the line card, add a forced-switch to the side of the ring that is to be removed. |
For example, you can enter a forced-switch command to force data traffic to one side of the ring when a 1OC-12/STM-4 SRP line card is removed from a router slot, or in response to an event. Table 10 provides an explanation of the IPS requests in the order of priority, from highest to lowest.
| SRP IPS Request | Explanation |
|---|---|
Forced-Switch | Adds a high-priority protection switch wrap on each end of a specified span by entering the user-configured srp ips request forced-switch command. |
Manual-Switch | Adds a low-priority protection switch wrap on each end of a specified span by entering the user-configured srp-ips request manual-switch command. |
If an automatic or user-configured wrap is inserted on a span between the source node and destination node, the source node that receives the wrap issues a request to insert a wrap on the destination node. Spatial Reuse will use the short path over the failed span. If the failure is unidirectional, Spatial Reuse will use the long path around the ring.
As the protection requests travel around the ring, the protection hierarchy is applied. For example, if a high-priority signal fail (SF) request enters the ring, it overrides a pre-existing lower-priority signal degrade (SD) request. If an event or a user-configured command enters a low-priority request, it is not allowed if a high-priority request is present on the ring.
![]() |
Note An exception is that multiple Signal Fail and forced-switch requests can coexist on the SRP ring. |
All protection switches are performed bidirectionally and enter wraps at both ends of a span for transmit and receive directions, even if a failure is only unidirectional.
Router# configure terminal Router(config)#
Step 2 Enter the interface srp global configuration command. The prompt changes to interface configuration mode.
Router(config)# interface srp 1/0 Router(config-if)#
Step 3 Enter a user-configured manual-switch or forced-switch wrap.
Router(config-if)# srp ips request manual-switch a Router(config-if)#
![]() |
Note A manual-switch does not appear in the show running configuration command output. |
Router(config-if)# srp ips request forced-switch a Router(config-if)#
![]() |
Note A forced-switch will override a signal degrade. |
Step 4 To set a non-default value of the wait-to-restore timer, enter an srp ips wait-to-restore timer interface configuration command and the value in seconds.
Router(config-if)# srp ips wtr-timer 60 Router(config-if)#
![]() |
Note All nodes on the SRP ring should have the same wait-to-restore, topology timer, and IPS values. |
Step 5 To set a non-default value for the frequency of IPS messages to display, enter the srp ips timer interface configuration command and specify the value in seconds.
Router(config-if)# srp ips timer 90 Router(config-if)#
Step 6 Type end until you return to the privileged EXEC mode.
Router(config-if)# end Router#
Step 7 Use the show srp slot/port EXEC command to display the status of the srp ips requests.
Router# show srp 2/0 Router#
This section shows configuration examples and the resulting output. Examples may be longer depending on the network configuration.
The following is an example of configuration file commands for a Cisco 12000 series router (first router) with an SRP line card in slot 3/port 0 connected back-to-back with a Cisco 7500 series router (second router) with an SRP port adaptor in slot 3/port 0:
First Router:
Router# interface srp 3/0 ip address 10.1.2.3 255.0.0.0 no shutdown no cdp enable no ip mroute-cache
Second Router:
Router# interface srp 3/0 ip address 10.1.2.4 255.0.0.0 no shutdown no cdp enable Router#
Each line card for the Cisco 12000 series router maintains information about its configuration, traffic, errors, and so on. You access this information by using the show commands. Following are descriptions and examples of the show commands that display line card information and system status.
The following commands output information about the system interfaces: show interface srp slot/port, show srp, show diag, show version, show protocols, show running-config and show controller srp.
Router# show interface srp 2/0
SRP2/0 is up, line protocol is up
Hardware is SRP over SONET, address is 0123.4567.0001 (bia 0050.e28c.5440)
Internet address is 10.1.2.1/24
MTU 4470 bytes, BW 622000 Kbit, DLY 100 usec, rely 255/255, load 1/255
Encapsulation SRP, Side A loopback not set Side B loopback not set
4 nodes on the ring MAC passthrough not set
Side A:not wrapped IPS local:IDLE IPS remote:IDLE
Side B:not wrapped IPS local:IDLE IPS remote:IDLE
Last input 00:00:00, output 00:00:00, output hang never
Last clearing of "show interface" counters 18:26:08
Queueing strategy:fifo
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 20000 bits/sec, 1 packets/sec
5 minute output rate 9000 bits/sec, 3 packets/sec
111517 packets input, 184059367 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
203428 packets output, 78234051 bytes, 0 underruns
0 output errors, 0 collisions, 0 interface resets
0 output buffer failures, 0 output buffers swapped out
Side A received errors:
0 input errors, 0 CRC, 0 runts, 0 giants, 0 ignored, 0 abort
Side B received errors:
0 input errors, 0 CRC, 0 runts, 0 giants, 0 ignored, 0 abort
Router#
Router# show srp 2/0
IPS Information for Interface SRP2/0
MAC Addresses
Side A (Outer ring RX) neighbor 0123.4567.0004
Side B (Inner ring RX) neighbor 0123.4567.0002
Node MAC address 0123.4567.0001
IPS State
Side A not wrapped
Side B not wrapped
Side A (Inner ring TX) IPS pkt. sent every 1 sec. (next pkt. after 0 sec.)
Side B (Outer ring TX) IPS pkt. sent every 1 sec. (next pkt. after 0 sec.)
IPS WTR period is 60 sec. (timer is inactive)
Node IPS State IDLE
IPS Self Detected Requests IPS Remote Requests
Side A IDLE Side A IDLE
Side B IDLE Side B IDLE
IPS messages received
Side A (Outer ring RX) {0123.4567.0002,IDLE,S}, TTL 128
Side B (Inner ring RX) {0123.4567.0004,IDLE,S}, TTL 128
IPS messages transmitted
Side A (Inner ring TX) {0123.4567.0001,IDLE,S}, TTL 128
Side B (Outer ring TX) {0123.4567.0001,IDLE,S}, TTL 128
Source Address Information for Interface SRP2/0
0123.4567.0001, index 1, pkt. count 409847
0123.4567.0002, index 2, pkt. count 2479330
0123.4567.0003, index 3, pkt. count 724384
0123.4567.0004, index 4, pkt. count 1472439
Topology Map for Interface SRP2/0
Topology pkt. sent every 10 sec. (next pkt. after 5 sec.)
Last received topology pkt. 00:00:04
Nodes on the ring:4
Hops (outer ring) MAC IP Address Wrapped Name
0 0123.4567.0001 10.1.2.1 No Router1
1 0123.4567.0002 10.1.2.2 No Router2
2 0123.4567.0003 10.1.2.3 No Router3
3 0123.4567.0004 10.1.2.4 No Router4
Router#
Router# show version Cisco Internetwork Operating System Software IOS (tm) GS Software (GSR-P-M), Version 11.2(18)GS3 Copyright (c) 1986-1999 by cisco Systems, Inc. Compiled Fri 15-Oct-99 16:59 by htseng Image text-base: 0x60010AF0, data-base: 0x608A0000 ROM: System Bootstrap, Version 11.2(9)GS5, [tamb 176]) BOOTFLASH: GS Software (GSR-BOOT-M), Version 11.2(15)GS3 Router uptime is 42 minutes System returned to ROM by reload at 15:55:51 UTC Wed May 19 1999 System image file is "muck/gsr-p-mz.112-18.GS3", booted via tftp from 223.255.24 cisco 12012/GRP (R5000) processor (revision 0x01) with 131136K bytes of memory. R5000 processor, Implementation 35, Revision 2.1 (512KB Level 2 Cache) Last reset from power-on 4 Route Processor Cards 2 Clock Scheduler Cards 3 Switch Fabric Cards 2 four-port OC3 POS controllers (8 POS). 1 one-port OC12 SONET based SRP controller (1 SRP). 1 Ethernet/IEEE 802.3 interface(s) 8 Packet over SONET network interface(s) 507K bytes of non-volatile configuration memory. 20480K bytes of Flash PCMCIA card at slot 0 (Sector size 128K). 20480K bytes of Flash PCMCIA card at slot 1 (Sector size 128K). 8192K bytes of Flash internal SIMM (Sector size 256K). Configuration register is 0x0 Router#
Router# show diag 2
SLOT 2 (RP/LC 2 ): 1 Port SONET based SRP OC-12c/STM-4 Single Mode
MAIN: type 53, 800-4202-02 rev 71 dev 16777215
HW config: 0x00 SW key: FF-FF-FF
PCA: 73-3237-05 rev 72 ver 5
HW version 2.1 S/N CAB03363Z27
MBUS: MBUS Agent (1) 73-5189-01 rev A0 dev 0
HW version 1.2 S/N CAB03363Z27
Test hist: 0xFF RMA#: FF-FF-FF RMA hist: 0xFF
DIAG: Test count: 0xFFFFFFFF Test results: 0xFFFFFFFF
MBUS Agent Software version 01.36 (RAM) (ROM version is 01.33)
Using CAN Bus A
ROM Monitor version 0E.00
Fabric Downloader version used 13.04 (ROM version is 10.03)
Primary clock is CSC 1
Board is analyzed
Board State is Line Card Enabled (IOS RUN )
Insertion time: 00:00:15 (00:43:40 ago)
DRAM size: 134217728 bytes
FrFab SDRAM size: 134217728 bytes, SDRAM pagesize: 8192 bytes
ToFab SDRAM size: 134217728 bytes, SDRAM pagesize: 8192 bytes
0 crashes since restart
Router#
Router# show running-config Building configuration... Current configuration: ! version 11.2 ! interface SRP2/0 ip address 70.0.0.20 255.0.0.0 no ip directed-broadcast no logging event subif-link-status srp topology-timer 10 no cdp enable Router#
(Remainder of displayed text omitted from example)
Router# show controller srp 2/0 SRP2/0 - Side A (Outer RX, Inner TX) SECTION LOF = 0 LOS = 0 BIP(B1) = 0 LINE AIS = 0 RDI = 0 FEBE = 0 BIP(B2) = 0 PATH AIS = 0 RDI = 0 FEBE = 0 BIP(B3) = 0 LOP = 0 NEWPTR = 0 PSE = 0 NSE = 0 Active Defects:None Active Alarms: None Alarm reporting enabled for:SLOS SLOF PLOP Framing :SONET Rx SONET/SDH bytes:(K1/K2) = 0/0 S1S0 = 0 C2 = 0x16 Tx SONET/SDH bytes:(K1/K2) = 0/0 S1S0 = 0 C2 = 0x16 J0 = 0xCC Clock source :Internal Framer loopback :None Path trace buffer :Stable Remote hostname :Router2 Remote interface:SRP2/0 Remote IP addr :10.1.2.2 Remote side id :B BER thresholds: SF = 10e-3 SD = 10e-6 TCA thresholds: B1 = 10e-6 B2 = 10e-6 B3 = 10e-6 SRP2/0 - Side B (Inner RX, Outer TX) SECTION LOF = 0 LOS = 0 BIP(B1) = 0 LINE AIS = 0 RDI = 0 FEBE = 0 BIP(B2) = 0 PATH AIS = 0 RDI = 0 FEBE = 0 BIP(B3) = 0 LOP = 0 NEWPTR = 0 PSE = 0 NSE = 0 Active Defects:None Active Alarms: None Alarm reporting enabled for:SLOS SLOF PLOP Framing :SONET Rx SONET/SDH bytes:(K1/K2) = 0/0 S1S0 = 0 C2 = 0x16 Tx SONET/SDH bytes:(K1/K2) = 0/0 S1S0 = 0 C2 = 0x16 J0 = 0xCC Clock source :Internal Framer loopback :None Path trace buffer :Stable Remote hostname :Router4 Remote interface:SRP2/0 Remote IP addr :10.1.2.4 Remote side id :A BER thresholds: SF = 10e-3 SD = 10e-6 TCA thresholds: B1 = 10e-6 B2 = 10e-6 B3 = 10e-6 Router#
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures:
Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product.
This class A digital apparatus complies with Canadian ICES-003.
Cet appareil numerique de la classe A est conforme a la norme NMB-003 du Canada.
This apparatus complies with EN55022 Class B and EN50082-2 standard requirements in Europe.
This is a class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual.

Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
![]() |
Note If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco's Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com. |
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments. 
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed Jul 19 19:16:02 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.