Channelized T3 Dual-Wide Port Adapter
Installation and Configuration

Channelized T3 Dual-Wide Port Adapter
Installation and Configuration

Product Number: PA-CT3/4T1(=)

This configuration note describes the installation and configuration of the channelized T3 dual-wide port adapter (PA-CT3/4T1), which can be used in Cisco  7200 series routers.


Note Use this configuration note in conjunction with the Cisco 7204 Installation and Configuration Guide or Cisco 7206 Installation and Configuration Guide that shipped with your Cisco 7200 series router.

This configuration note also contains basic configuration steps and examples. For complete descriptions of additional interface subcommands and configuration options available for your router, refer to the appropriate configuration publications listed in the section "If You Need More Information". (Also refer to the section "Software and Hardware Requirements".)

Document Contents

Sections in this document include the following:

This section contains important information about specific software and hardware requirements for the PA-CT3/4T1 port adapter.

If You Need More Information

The Cisco IOS software running your router contains extensive features and functionality. The effective use of many PA-CT3/4T1 port adapter features is easier if you have more information at hand. For additional information on configuring the Cisco 7200 series routers and the PA-CT3/4T1 port adapter, the following documentation resources are available:

Product Description

The CT3 channelized port adapter (PA-CT3/4T1) is a dual-wide module that provides four T1 connections via DB-15 connectors and one DS3 connection via BNC connectors. (See Figure 1.) Each DS3 interface can provide up to 28 T1 channels (a single T3 group). Each channel is presented to the system as a serial interface that can be configured individually.


Figure 1: PA-CT3/4T1 Port Adapter, Front-Panel View


The PA-CT3/4T1 port adapter has the following features and physical characteristics:

T3 Overview

T3 traditionally involves multiplexing 28 T1 lines on to a single higher-speed line (T3 line). Each of the 28 T1 lines in the T3 are asynchronous to one other. A T1 line accommodates 24 64-kilobit-per-second (Kbps) DS0 channels. While the DS0s are byte multiplexed to each T1, the T1 lines are bit multiplexed to the T3 in a framing format called M23 or C-BIT parity.

M13 multiplexing is done in two steps. First, four T1 lines are bit multiplexed together to form a DS2 line using M12 multiplexing. These seven DS2 lines are then bit multiplexed together to form the DS3/T3 using M23 multiplexing.

M13 multiplexing uses bit stuffing to bring each asynchronous DS1/DS2 up to a common data rate for transmission. C-BIT Parity multiplexing forces the seven DS2s to be synchronous to each other at a rate that causes 100-percent pulse stuffing in the M23 frame. This allows the "stuff" indicator bits in the M23 frame to be used as a maintenance link between the end points.

CT3 Channelized Dual-Wide Port Adapter Overview

The CT3 channelized dual-wide port adapter (PA-CT3/4T1) functions very much like an M13 multiplexer with each T1 line terminating with or originating into or from an HDLC controller on the port adapter. The PA-CT3/4T1 port adapter offers 28 individual T1 channels (bundled in the T3) for serial transmission of data. Each of the T1 channels uses a portion of the T1 bandwidth (fractional T1) or the entire T1 bandwidth for data transmission. Usable bandwidths  for each T1 are n x 56 Kbps or n x 64 Kbps, where n is a number from 1 to 24. The unused portion of the T1 bandwidth, when not running at full T1 speeds, cannot be used and is filled with idle channel data.


Note The n x 56-Kbps bandwidths are only available on DS1s 21 through 28. T1 channels on the PA-CT3/4T1 port adapter are numbered 1-28, rather than the more traditional zero-based scheme (0-27) used with other Cisco products. This is to ensure consistency with Telco numbering schemes for T1 channels within channelized T3 equipment.

The T3 section of the PA-CT3/4T1 port adapter supports the maintenance data link channel (C-BIT parity) as well as payload and network loopbacks. The T1 section of the PA-CT3/4T1 port adapter supports facilities data link (FDL) in extended super frame (ESF) framing, as well as network and payload loopbacks. Bit error rate testing (BERT) is supported on each of the T1 links. The BERT testing is only done over a framed T1 signal. The M13 multiplexer performs M12 multiplexing on 4 four T1 signals. (There are seven M12 multiplexers available on board.) The seven M12 multiplexers pass their data to the M23 multiplexer, which takes the seven tributaries and formats them into a DS3 stream. This transmit stream is passed on to the T3 line interface unit (LIU) for transmission out of the BNC connector into a 75-ohm coaxial line.

The first three T1 channels of the channelized T3 can be broken out, under software control, to the three DB-15 connectors on the front of the PA-CT3/4T1 port adapter for further demultiplexing via a MultiChannel Interface Processor (MIP). This allows three (the first three) of the 28 T1 streams in the channelized T3 to be a channelized T1 stream.

The broken-out T1(s) are sent to a T1 LIU, which transmits the T1(s) at the DSX-1 level. (DSX-1 refers to the cross connection point for DS-1 signals.) When operating in this mode, these ports are not CSU ports. They do not detect loop codes, provide ones-density requirements, or respond to any FDL messages. The receiving end (MIP) must provide the CSU functionality. Under software control, each external T1 port can be disabled or enabled.

The PA-CT3/4T1 port adapter does not support the aggregation of multiple T1s (called inverse muxing or bonding) for higher bandwidth data rates. The PA-CT3/4T1 port adapter supports Cisco HDLC, Frame Relay, PPP, and SMDS Data Exchange Interface (DXI) encapsulations over each T1 link. For SMDS only, DXI is sent on the T1 line so it needs to connect to an SMDS switch that has direct DXI input.

There is a special DB-15 connector on the PA-CT3/4T1 port adapter, labeled TEST. This test connector allows you to break out any T1 of the T3 stream, under software control. This functionality allows you to break out any of the 28 T1s within the T3 stream for testing (for example, 24-hour BERT testing as is commonly done by telephone companies before a line is brought into service), or for further channelization via a MIP card.

Location of PA-CT3/4T1 Port Adapter in a Cisco 7200 Series Router

Figure 2 shows a Cisco 7206 router with port adapters installed. In the Cisco 7206 router, port adapter slot  1 is in the lower left position, and port adapter slot  2 is in the lower right position. (The CT3 channelized port adapter can be installed in any horizontal pair of these slots; use the odd-numbered slot number associated with the left-side slots.)


Note The PA-CT3/4T1 port adapter is a high-speed port adapter. No more than two PA-CT3/4T1 port adapters can be installed in a Cisco 7200 series router. Any other configuration is not supported.

Also, the PA-CT3/4T1 port adapter can be used only on a Cisco 7200 series router that has a 150-MHz or 200-MHz network processor.

Figure 2: Port Adapter Slots in the Cisco 7206 Router

PA-CT3/4T1 Port Adapter Cables

For T1, two standard serial cables, null-modem and straight-through, are available from Cisco Systems and other vendors for use with the PA-CT3/4T1 port adapter. The PA-CT3/4T1 port adapter T1 interface cables are used to connect your router to external CSUs or a MIP card. The PA-CT3/4T1 port adapter T1 interface cables have two male 15-pin DB connectors at each end to connect the PA-CT3/4T1 port adapter's T1 interfaces.

Figure 3 shows the PA-CT3/4T1 port adapter interface cable, connectors, and pinouts. Table 1 lists the signal pinout for the straight-through cable. Table 2 lists the signal pinout for the null-modem cable.


Figure 3: PA-CT3/4T1 Port Adapter T1 Interface Cable and Connectors



Table 1:
T1 Straight-Through Cable Signals
DB-15 Connector DB-15 Connector
Pin Signal1 Pin Signal

1

Tx tip

1

Tx tip

3

Rx tip

3

Rx tip

9

Tx ring

9

Tx ring

11

Rx ring

11

Rx ring

Case

Ground/shield

Case

Ground/shield

1Tx = transmit. Rx = receive.

Table 2:
T1 Null-Modem Cable Signals
DB-15 Connector DB-15 Connector
Pin Signal1 Pin Signal

1

Tx tip

3

Rx tip

3

Rx tip

1

Tx tip

9

Tx ring

11

Rx ring

11

Rx ring

9

Tx ring

Case

Ground/shield

Case

Ground/shield

1Tx = transmit. Rx = receive.

Compliance and Electrical Interface Specifications for T3 and T1

The T3 line interface unit (LIU) is designed to meet the following specifications:

The T3 LIU is compliant for the above specifications for input jitter tolerance, pulse shape/amplitude (DSX3), line termination, and jitter. The LIU has a flat transfer function so jitter introduced by the LIU is insignificant.

The PA-CT3/4T1 port adapter's T3 port is designed to receive and transmit at the DSX-3 level while driving and receiving from a 75-ohm coaxial cable (ATT 728A type coax). It connects directly to any equipment with DSX-3 level BNC connectors. The T3 front end is designed to meet the following specifications:

The T1 LIU is designed to meet the following specifications. (See also Table 3.)

The T1 LIU is designed to meet the preceding specifications for input jitter tolerance, pulse shape/amplitude (DSX1), line termination, and jitter. The LIU has a relatively flat transfer function so jitter introduced by the LIU is minimal.

The PA-CT3/4T1 port adapter T1 ports are designed to receive and transmit at the DSX-1 level while driving and receiving from a 100-ohm twisted-pair cable. It connects directly to any equipment with DSX-1 level input/output. The T1 front end is designed to meet the following specifications:


Table 3:
T1 Channel No. Data Rates

1-20

n x 64 Kbps up to full T1 (1.536 Mbps)

21-28

n x 56 Kbps up to full T1 (1.344 Mbps)
or n x 64 Kbps up to full T1 (1.536 Mbps)

T1 Channel Data Rates

PA-CT3/4T1 Port Adapter Installation Prerequisites

Before you begin the installation, review the guidelines in this section to assure proper system operation, avoid injuring yourself, or damaging the equipment.

This section provides software requirements, a list of parts and tools you will need to perform the port adapter installation, and safety and ESD-prevention guidelines to help you avoid injury and damage to the equipment during installation. This section also includes information on the systems in which port adapters can be installed and overview information on interface specifications.


Note The PA-CT3/4T1 port adapter is a high-speed port adapter. No more than two PA-CT3/4T1 port adapters can be installed in a Cisco 7200 series router. Any other configuration is not supported.

The following sections present general information and information about port adapter installation requirements:

Software and Hardware Requirements

The PA-CT3/4T1 port adapter is compatible with any Cisco 7200 series router that is operating with Cisco IOS Release 11.1.16(CA) or later.

The PA-CT3/4T1 port adapter and Cisco 7200 series router's network processor memory configurations include the following:


Note For specific software features and commands available for the PA-CT3/4T1 port adapter and the Cisco IOS release in which they are supported, refer to the Cisco  IOS release note specific to your Cisco IOS release.

Note For port adapter hardware and memory configuration guidelines for Cisco  7200  series  routers, refer to the document Cisco 7200 Series Port Adapter Hardware Configuration Guidelines.

To determine if your Cisco 7200 series router is compatible with the PA-CT3/4T1 port adapter, use the show version command to display the current hardware configuration of the router, including the system software version that is currently loaded and running.

In the following example, the running system software is Release  11.1.16(CA).

Router> show version
Cisco Internetwork Operating System Software 
IOS (tm) 7200 Software (C7200-P-M), Version 11.1.16(CA)
Synced to mainline version: 11.1(12.1)
Copyright (c) 1986-1997 by cisco Systems, Inc.
Compiled Mon 30-Jun-97 08:45

You can check the version of the default ROM image by removing the board and checking the ROM labels, or by configuring the interface or system software to boot from ROM, restarting the system, and using these same commands to check the running version.

If the displays indicate that the running system software is earlier than Cisco IOS Release  11.1.16(CA) or later, check the contents of Flash memory to determine if the required images are available on your system. The show flash command displays a list of all files stored in Flash memory.

The show microcode command displays a list of all the microcode images currently bundled with the Cisco IOS software. If these displays indicate that the required system software and microcode are not available, contact a service representative for upgrade information. For information on additional show commands, refer to "Command Descriptions and Examples".

List of Parts and Tools

You need the following parts and tools to install a PA-CT3/4T1 port adapter. If you need additional equipment, ask your service representative for ordering information.

Safety Guidelines

This section lists safety guidelines you should follow when working with any equipment that connects to electrical power or telephone wiring.

Safety Warnings

Safety warnings appear throughout this publication in procedures that, if performed incorrectly, may harm you. A warning symbol precedes each warning statement.

Warning Means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Waarschuwing    Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen, kunt u het document Regulatory Compliance and Safety Information (Informatie over naleving van veiligheids- en andere voorschriften) raadplegen dat bij dit toestel is ingesloten.

Varoitus    Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta).

Attention    Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d'avertissements figurant dans cette publication, consultez le document Regulatory Compliance and Safety Information (Conformité aux règlements et consignes de sécurité) qui accompagne cet appareil.

Warnung    Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Dokument Regulatory Compliance and Safety Information (Informationen zu behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät geliefert wurde.

Avvertenza    Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nel documento Regulatory Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) che accompagna questo dispositivo.

Advarsel    Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i dokumentet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) som ble levert med denne enheten.

Aviso    Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte o documento Regulatory Compliance and Safety Information (Informação de Segurança e Disposições Reguladoras) que acompanha este dispositivo.

¡Advertencia!    Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo.

Varning!    Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information (Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning.

Electrical Equipment

Follow these basic guidelines when working with any electrical equipment:

Telephone Wiring

Use the following guidelines when working with any equipment that is connected to telephone wiring or to other network cabling:

Preventing Electrostatic Discharge Damage

Electrostatic discharge (ESD) damage, which can occur when electronic cards or components are improperly handled, results in complete or intermittent failures. Port adapters and processor modules consist of printed circuit boards that are fixed in metal carriers. Electromagnetic interference (EMI) shielding and connectors are integral components of the carrier. Although the metal carrier helps to protect the board from ESD, use a preventive antistatic strap during handling.

Use these guidelines to prevent ESD damage:

Guidelines for Port Adapter Removal and Installation

This section describes mechanical functions of system components, emphasizes the importance of following correct procedures to avoid unnecessary board failures, and is for background only; specific procedures follow in the section "Installing or Removing a Port Adapter in a Cisco 7200 Series Router".

You can remove and replace port adapters while the system is operating; you do not need to notify the software or reset the system power. This functionality enables you to add, remove, or replace port adapters with the system online, which provides a method that is seamless to end users on the network, maintains all routing information, and ensures session preservation.

After a port adapter is reinstalled, the system brings on line only interfaces that match the current configuration and were previously configured as up; all others require that you configure them with the configure command. .

Caution The system can indicate a hardware failure if you do not follow proper procedures. Remove or insert only one port adapter at a time. Allow at least 15 seconds for the system to complete the preceding tasks before removing or inserting another port adapter. Disrupting the sequence before the system completes its verification can cause the system to interpret hardware failures.

All port adapters have ejector levers that allow you to firmly seat a port adapter in the port adapter slot. The function of the ejector levers is to align and seat the card connectors in the backplane. Failure to use the ejector levers and insert the port adapter properly can disrupt the order in which the pins make contact with the backplane.

Follow the installation and removal instructions carefully, and review the following examples of incorrect insertion practices and results:

It is also important to use the ejector levers when removing a port adapter to ensure that the board connector pins disconnect from the backplane in the logical sequence expected by the system. Any port adapter that is only partially connected to the backplane can hang the bus. Detailed steps for correctly installing and removing the port adapter follow.

For detailed directions about removal and installation, follow the procedures in the section "Installing or Removing a Port Adapter in a Cisco 7200 Series Router"..

Caution Always use the ejector levers to remove or install the PA-CT3/4T1 port adapter. The ejectors help ensure that backplane connectors on the card are fully seated in, or fully ejected from, the backplane. Failure to use the ejector levers could result in a partial backplane connection, which can hang the system.

Installing or Removing a Port Adapter in a Cisco 7200 Series Router

The PA-CT3/4T1 port adapter can be installed in any available, horizontally aligned pair of port adapter slots in a Cisco 7200 series router. Figure 4 shows a PA-CT3/4T1 port adapter installed in port adapter slot  3 and slot 4 of a Cisco 7206 router.


Note The slot number used shall be that of the odd-numbered left-side slots in the Cisco 7200 series router.

Note You can install up to two PA-CT3/4T1 port adapters in a Cisco 7200 series router. No other configuration is supported.

Figure 4: Cisco 7206 Router with a PA-CT3/4T1 Port Adapter in Port Adapter Slot  4


You might need to install a new port adapter in a Cisco  7200 series router or replace a failed port adapter in the field. In either case, no tools are necessary; any port adapter available for the Cisco  7200 series routers connects directly to the router midplane and is locked into position by a port adapter lever. When removing and replacing a port adapter, you need the following:

If you plan to remove a PA-CT3/4T1 port adapter or some other dual-wide port adapter from a Cisco  7200 series router and replace it with a PA-CT3/4T1 port adapter, use the instructions in these two sections:

    1 Removing a Port Adapter

    2 Installing a Dual-Wide Port Adapter

If, however, you are replacing two single-width port adapters (or port adapter blanks) in a Cisco  7200 series router with a new PA-CT3/4T1 port adapter, you first need to remove the port adapter slot divider before you can install the PA-CT3/4T1 port adapter. To do so, use the instructions in these sections:

    1 Removing a Port Adapter

    2 Removing and Replacing a Port Adapter Slot Divider

    3 Installing a Dual-Wide Port Adapter


Note The Cisco  7200 series routers support online insertion and removal (OIR); therefore, you do not have to power down the Cisco  7200 series router when you are removing and replacing a PA-CT3/4T1 port adapter.

When a port adapter slot is not in use, a blank port adapter must fill the empty slot. This allows the router to conform to EMI emissions requirements and helps provide proper air flow across the port adapters. If you plan to install a new port adapter in a slot that is not in use, you must first remove a blank port adapter.

Removing a Port Adapter

The PA-CT3/4T1 port adapter requires two adjacent port adapter slots in a Cisco 7200 series router.

Here is the procedure for removing a port adapter from a Cisco 7200 series router:

Step 1 Attach an ESD-preventive wrist strap to yourself and to an unfinished chassis surface.

Step 2 Move the port adapter lever for the desired port adapter slot to the unlocked position. (See Figure 5.)


Note If you plan to remove only one port adapter, unlock only its port adapter lever. If you plan to remove two adjacent port adapters, in preparation for installing a dual-wide port adapter, unlock both port adapter levers as shown in Figure 5.

Figure 5: Placing the Port Adapter Lever in the Unlocked Position (Cisco 7206 Shown)

Step 3 Grasp the two handles on the port adapter and pull the port adapter from the midplane, about halfway out of its slot. If you are removing a blank port adapter, pull the blank port adapter out of the chassis slot.


Note As you disengage the port adapter from the router midplane, the OIR feature administratively shuts down all active interfaces on the port adapter.

Step 4 With the port adapter halfway out of the slot, disconnect all cables from the port adapter.

Step 5 After disconnecting the cables, pull the port adapter from its chassis slot..

Caution Always handle the port adapter by the carrier edges and handles; never touch the port adapter's components or connector pins. (See Figure 6.)


Figure 6:
Handling a Port Adapter


Step 6 Place the port adapter on an antistatic surface with its components facing upward, or in a static shielding bag. If you are returning the port adapter to Cisco, immediately place it in a static shielding bag.


Note If you plan to remove two adjacent port adapters in preparation for installing a dual-wide port adapter, repeat Steps 2 through 6; otherwise, this completes the procedure for removing port adapters from a Cisco  7200 series router.

If you plan to replace two single-width port adapters with a new PA-CT3/4T1 port adapter, you need to first remove the port adapter slot divider before you can install the PA-CT3/4T1 port adapter; therefore, proceed to the section
"Removing and Replacing a Port Adapter Slot Divider".

Removing and Replacing a Port Adapter Slot Divider

The following sections explain how to remove and replace a port adapter slot divider in a Cisco  7200 series router. If you are replacing a PA-CT3/4T1 port adapter, this slot divider is already removed and you can proceed to the section "Installing a Dual-Wide Port Adapter".

Removing a Port Adapter Slot Divider

Following is the procedure for removing a port adapter slot divider from a Cisco 7200 series router:

Step 1 Remove the port adapters from the slots on both sides of the port adapter slot divider. Refer to the previous section "Removing a Port Adapter" when removing a port adapter from a Cisco 7200 series router.

Step 2 With one hand, raise the slot divider lever to unlock the slot divider from the chassis. (See  Figure 7.)


Figure 7: Lifting the Slot Divider Lever (Cisco 7206 Shown)

Step 3 With the slot divider lever still raised, use your other hand to pull the slot divider from the chassis. (See Figure 8.)


Figure 8: Pulling the Slot Divider from the Chassis (Cisco 7206 Shown)

Step 4 Store the slot divider for use at a later date.

This completes the procedure for removing a port adapter slot divider from a Cisco  7200 series router. Proceed to the section "Installing a Dual-Wide Port Adapter".

Replacing a Port Adapter Slot Divider

Following is the procedure for installing a port adapter slot divider in a Cisco  7200 series router.


Note You might need to replace the port adapter slot divider at some future time; if so, use the following procedure.

Step 1 Position the slot divider so that the slot divider lever faces you and is at the bottom.

Step 2 Align the left and right edges of the slot divider between the guides in the port adapter slot. (See Figure 9.)


Figure 9: Aligning the Slot Divider Between the Slot Guides (Cisco 7206 Shown)

Step 3 With the left and right edges of the slot divider aligned in the slot guides, slide the slot divider all the way into the slot until you feel the slot divider lock into place (listen for a click).

This completes the procedure for installing a port adapter slot divider in a Cisco  7200 series router.

Installing a Dual-Wide Port Adapter

Following is the procedure for installing a new dual-wide port adapter in a Cisco 7200 series router:

Step 1 Attach an ESD-preventive wrist strap to yourself and to an unfinished chassis surface.

Step 2 Use both hands to grasp the port adapter by its metal carrier edges with the adapter components facing downward. (See Figure 6.)

Step 3 Align the left and right edges of the port adapter metal carrier between the guides in the port adapter slot. (See Figure 10.)


Figure 10: Aligning the Port Adapter Metal Carrier Between the Slot Guides (Cisco 7206 Shown)

Step 4 With the metal carrier edges aligned in the slot guides, gently slide the port adapter halfway into the slot..

Caution Do not slide the port adapter all the way into the slot until you have connected all cables. Doing so disrupts normal operation of the router.

Step 5 With the port adapter halfway into the slot, connect all required cables to the port adapter.

Step 6 After connecting all required port adapter cables, carefully slide the port adapter all the way into the slot until you feel the port adapter's connectors mate with the midplane.

Step 7 After feeling the connectors mate, move the port adapter lever to the locked position. Figure 11 shows the port adapter lever in the locked position.


Note If the port adapter lever does not move to the locked position, the port adapter is not properly seated in the midplane. Carefully pull the port adapter halfway out of the slot, reinsert it, and move the port adapter lever to the locked position.

Figure 11: Port Adapter Lever in the Locked Position (Cisco 7206 Shown)

This completes the procedure for installing a new port adapter in a Cisco  7200 series router.

Attaching Network Interface Cables to the PA-CT3/4T1 Port Adapter

Attach the PA-CT3/4T1 port adapter network interface cables between the port adapter interface ports and the CSU. This includes up to four T1 cables and two DS1 BNC cables. (See Figure 12.) Proceed to the following section to check the cable connections.


Figure 12: Connecting Interface Cables to the CT3 Channelized Port Adapter


Using LEDs to Check PA-CT3/4T1 Port Adapter Initialization

The PA-CT3/4T1 port adapter has several status LEDs on its faceplate. (See Figure 13.)


Figure 13: PA-CT3/4T1 Port Adapter LEDs, Horizontal Orientation


Following are the functions of the PA-CT3/4T1 port adapter LEDs:

For additional functions of the status and alarm LEDS, refer to the section "Using Status and Alarm LED Indications".

The individual 1, 2, 3, and test LEDS next to each T1 port indicate the following: This green LED will go on when the respective port is enabled. When the port is not enabled, the LED is off.

The remaining five LEDs, between the TEST and T3 ports, indicate the following:


Note For additional functions of the status and alarm LEDS, refer to the section "Using Status and Alarm LED Indications".

Observe the LED states and the console displays as the router initializes. When the system has reinitialized all interfaces, the enabled LED on the PA-CT3/4T1 port adapter should go on.

The console screen will also display a message as the system discovers each interface during its reinitialization. After system initialization, the enabled LED goes on to indicate that the PA-CT3/4T1 port adapter is enabled for operation.

The following conditions must be met before the PA-CT3/4T1 port adapter is enabled:

If any of these conditions is not met, the enabled LED does not go on.

Verify that the PA-CT3/4T1 port adapter is connected correctly as follows:

Step 1 While the system reinitializes each interface, observe the console display messages and verify that the system discovers the PA-CT3/4T1 port adapter. The system should recognize the PA-CT3/4T1 port adapter's interfaces but leave them configured as down.

Step 2 When the reinitialization is complete, verify that the enabled LED on the PA-CT3/4T1 port adapter is on and remains on. If the LED does stay on, proceed to Step 5. If the enabled LED does not stay on, proceed to the next step.

Step 3 If the enabled LED on the PA-CT3/4T1 port adapter fails to go on, suspect the that the PA-CT3/4T1 port adapter board connector is not fully seated in the backplane. After the system reinitializes the interfaces, the enabled LED on the PA-CT3/4T1 port adapter should go on. If the enabled LED goes on, proceed to Step 5. If the enabled LED does not go on, proceed to the next step.

Step 4 If the enabled LED still fails to go on, remove the PA-CT3/4T1 port adapter and try installing it in another available port adapter slot.

Step 5 Use the show interfaces command to verify the status of the PA-CT3/4T1 port adapter's interfaces. (If the interfaces are not configured, you must use the procedures in the section "Configuring the T3 and T1 Interfaces", which are not available until you configure them.)

If an error message displays on the console terminal, refer to the appropriate reference publication for error message definitions. If you experience other problems that you are unable to solve, contact a service representative for assistance.

Configuring the T3 and T1 Interfaces

If you installed a new PA-CT3/4T1 port adapter or if you want to change the configuration of an existing controller, you must enter the Configuration mode. If you replaced the PA-CT3/4T1 port adapter that was previously configured, the system will recognize the new PA-CT3/4T1 port adapter and bring it up in the existing configuration.

After you verify that the new PA-CT3/4T1 port adapter is installed correctly, use the privileged-level configure command to configure the new PA-CT3/4T1 port adapter controller. Be prepared with the information you will need, such as the following:

For a complete summary of the configuration options available and more detailed instructions for configuring the PA-CT3/4T1 port adapter controller, refer to the appropriate configuration publications, which are listed in the section "If You Need More Information".

Using the EXEC Command Interpreter

Before you can use the configure command, you must enter the privileged level of the EXEC command interpreter with the enable command. The system will prompt you for a password if one has been set.

The system prompt for the privileged level ends with a pound sign (#) instead of an angle bracket (>). At the console terminal, enter the privileged level as follows:

Step 1 At the user-level EXEC prompt, enter the enable command. The EXEC prompts you for a privileged-level password as follows:

Step 2 Enter the password (the password is case sensitive). For security purposes, the password is not displayed.

Step 3 When you enter the correct password, the system displays the privileged-mode system prompt (#) as follows:


Note To save your configuration changes to NVRAM, use the copy running-config startup-config command at the privileged-mode system prompt.

Proceed to the following section to configure the PA-CT3/4T1 port adapter controller.

Interface Port Numbering for T1 and T3

The interface numbering scheme for the PA-CT3/4T1 port adapter's T1 interfaces is in the form of slot/port:t1 channel where slot refers to the chassis slot in which the PA-CT3/4T1 port adapter is installed; port refers to the physical port on the PA-CT3/4T1 port adapter and is always 0; and t1 channel is a number between 1 and 28. (Refer to the section "Configuring the T3 and T1 Interfaces", for more specific interface configuration information.)


Note T1 channels on the PA-CT3/4T1 port adapter are numbered 1-28, rather than the more traditional zero-based scheme (0-27) used with other Cisco products. This is to ensure consistency with Telco numbering schemes for T1 channels within channelized T3 equipment.

Designate and turn on an external T1 port (one of the three DB-15 connectors labeled 1 through 3) using the t1 external channel command, where t1 channel is a number between 1 and 3.

Designate and turn on the T1 test port (the DB-15 connector labeled TEST) using the t1 test channel command, where t1 channel is a number between 1 and 28.

Port Numbering Examples and Sample Displays

Following are examples of PA-CT3/4T1 port adapter interface port numbering and sample displays:

The following sample display shows the events logged by the system as the PA-CT3/4T1 port adapter was removed from slot 3; the system then reinitialized the remaining port adapters and marked as down the PA-CT3/4T1 port adapter when it is installed in slot 5. When the PA-CT3/4T1 port adapter was reinserted, the system marked the interfaces as down again because the PA-CT3/4T1 port adapter interfaces were not shut down before the PA-CT3/4T1 port adapter was removed.

Router#
%OIR-6-REMCARD: Card removed from slot 3, interfaces disabled
%LINK-5-CHANGED: Interfaces T1 3/0, changed to administratively down

When a new PA-CT3/4T1 port adapter is inserted, or when a PA-CT3/4T1 port adapter whose interfaces are shut down is moved to a new slot, the system recognizes the PA-CT3/4T1 port adapter controller, but leaves its interfaces in a shutdown state until you configure them and change the state to up with the configure command. If you move a PA-CT3/4T1 port adapter to a new slot and its interfaces were not shut down, the system recognizes them as not shut down when the PA-CT3/4T1 port adapter is installed in the new slot.

The following example display shows the events logged by the system as a new PA-CT3/4T1 port adapter is inserted in slot  5:

Router#
%OIR-6-INSCARD: Card inserted in slot 5, interfaces administratively shut down
%LINK-5-CHANGED: Interfaces T3 5/0, changed to administratively down
Router#

Configuration Guidelines and Configuration Command Examples

The following steps describe basic configuration guidelines and configuration command examples for the T3 and then T1 interfaces. Press the Return key after each step.

Configuring the T3 Interface

Following are the steps to configure the T3 interface:

Step 1 At the privileged-mode prompt, enter Configuration mode and specify that the console terminal will be the source of the configuration subcommands as follows:

Step 2 Specify the controller to configure by entering the subcommand controller, followed by t3, and slot/port (port adapter slot number/interface port number). The example that follows is for the PA-CT3/4T1 port adapter in port adapter slot 3for T3 channel 0:

Step 3 At the prompt, specify the framing type using the framing [c-bit | m23 | auto-detect] command: set c-bit framing format, as follows:

At the prompt, request the PA-CT3/4T1 port adapter to detect the framing type it is to receive from the far end, as follows:

Step 4 Specify the cable length using the cablelength feet command, where feet is expressed as a numeral from 0 to 450, with the default value of 224 feet. Issue the cablelength command as follows:


Note For the cablelength feet command, user-specified T3 cable lengths are structured into ranges as follows: 0-224 and 225-450. If a cable length value is entered, which falls into one of these ranges, the range within which that value applies will be used.

In the preceding example, a cable length of 200 is specified. If it is changed to 220, then the 0-224 range applies in each case. Further, if a cable length of 300 is specified, then is changed to 400, the 225-450 range applies in each case; therefore, these changes have no effect. Only moving from one range to another has an effect. The actual number you enter is stored in the configuration file.

Step 5 Specify the clock source for the controller using the clock source [internal | line] command, which determines which end of the circuit provides the clocking.

If the PA-CT3/4T1 port adapter is not connected to an external clock source, you must use the internal option.


Note To shut down the T3 interface, use the shutdown command at the controller prompt.
Configuring MDL Messages

Maintenance Data Link (MDL) messages (which are defined in the ANSI T1.107a-1990 specification) can be configured on the PA-CT3/4T1 port adapter.


Note MDL messages are only supported when the DS3 framing is set for C-BIT parity; refer to
Step 3 in the section "Configuring the T3 Interface".

To configure MDL messages, use the following controller configuration commands:

mdl {transmit {path | idle-signal | test-signal} | string {eic | lic | fic | unit | pfi | port | generator} string}

no mdl
{transmit {path | idle-signal | test-signal} | string {eic | lic | fic | unit | pfi | port | generator} string}

where the command arguments are defined as follows:

Use the no form of this command to remove message. The default is that no MDL message is configured.

Examples of MDL Message Configuration

Following are examples of configuring MDL messages; enter controller Configuration mode first, as follows:

Router# conf t
Enter configuration commands, one per line. End with CNTL/Z. Router(config)# cont t3 5/0
Router(config-controll)# 
Router(config-controll)# mdl string eic router A


Router(config-controll)# mdl string lic test network


Router(config-controll)# mdl string fic buidling b


Router(config-controll)# mdl string unit abc


Router(config-controll)# mdl string pfi string


Router(config-controll)# mdl string port string


Router(config-controll)# mdl string generator string


Router(config-controll)# mdl transmit path


Router(config-controll)# mdl transmit idle-signal


Router(config-controll)# mdl transmit test-signal

Configuring the Logical T1 Interfaces

Following are the guidelines for configuring the logical T1 interfaces using controller configuration commands. Examples follow:

Step 1 Specify the channel and timeslots to be mapped using the t1 t1 channel timeslots range [speed {56 | 64}] command.

Where T1 channels are 1-28, range supports contiguous timeslots as well as arbitrary timeslots, and a speed of 56 Kbps is only valid for T1 21-28 (default is 64 Kbps).

Examples follow:

Configure T1 1for full T1 bandwidth, as follows:

Configure the T1 20 to use timeslots 1 through 5 and timeslots 20 through 23 as follows:

Configure the T1 21 for 24 x 56 Kbps as follows:

Step 2 Specify the T1 framing format using the t1 t1 channel framing [esf | sf] command. The default is the extended super frame (ESF) framing format, and T1 channel is 1-28.

Examples follow:

Set super frame (SF) framing format for T1 6 as follows:


Note You can use the [no] t1 t1 channel yellow [detection | generation] command (where T1 channel is 1-28) to turn the detection or generation of a yellow alarm on and off. When you select SF framing, you should consider using the no t1 channel yellow detection command to turn off yellow alarm detection because the yellow alarm can be incorrectly detected with SF framing.

Set ESF framing format for T1 18 as follows:

Step 3 Specify remote T1 line code using the t1 t1 channel linecode [ami | b8zs] command. The default is b8zs, and the T1 channel is 1-28.

An example follows:


Note The default for the logical T1 interfaces is noninverted data; however, if the ami argument is selected with the linecode command, inverted data is required (using the invert data interface subcommand) because the T1 channel is bundled into the T3 signal, so there are no local T1 line drivers and receivers associated with it. Therefore, the t1 1 linecode ami command does not modify local line driver settings. Rather, it advises the PA-CT3/4T1 port adapter what line code the remote T1 is using. The PA-CT3/4T1 port adapter uses this information solely for the purpose of determining whether or not to enable the pulse density enforcer for that T1 channel.

When the argument b8zs is selected, the pulse density enforcer will be disabled. When the ami argument is selected, the pulse density enforcer will be enabled. To avoid having the pulse density enforcer corrupt data, the T1 interface should be configured for inverted data, as described above, when the ami argument is selected.

Step 4 Specify the T1 clock source using the t1 t1 channel clock source [internal | line] command, where the T1 channel is 1-28, and the default is network (line) clocking.

Examples follow:

Set internal clock source for T1 6 as follows:

Set network clock source for T1 1 as follows:

To remove a T1 channel, use the no t1 t1 channel timeslots 1-24 command, where the T1 channel is 1-28. For example, remove the channel for T1 20 as follows:

Router(config-controll)# no t1 20 timeslots 1-24

Note After a T1 channel is configured, it appears to the Cisco IOS software as a serial interface; therefore, all the configuration commands for a serial interface are available. However, not all commands are applicable to the T1 interface. All the encapsulation formats, such as PPP, HDLC, SMDS, and Frame Relay are applicable to the configured T1. Encapsulation can be set via the serial interface configuration commands. All the switchings that are applicable to a serial interface, including the optimum switch, are also applicable to the configured T1 channel.
Configuring the External T1 Ports on a PA-CT3/4T1 Port Adapter

The following controller configuration commands are valid only to the first three T1 channels (T1 1 through 3) when they are broken out to the external T1 port. Configure a T1 Interface as an external port using the t1 external t1 channel [linecode {b8zs | ami}] [cablelength  feet] command, where external T1 channels are 1-3, and the cable length range is 0-655 feet. The default values are as follows: line code is B8ZS; cable length is 133 feet.

(Use the show controller t3 command to check the status of the external ports; refer to the example of this command on page 34 of the section "Command Descriptions and Examples".)

For example, configure T1 1 to be an external port as follows:

Router(config-controll)# t1 external 1 linecode ami cablelength 300

To remove a T1 interface from an external port, use the no t1 external t1 channel command, where external T1 channels are 1-3.

For example, remove T1 1 from external port 1 as follows:

Router(config-controll)# no t1 external 1

Note If a T1 channel that was previously configured as a serial interface is broken out to the external T1 port, that interface and its associated configuration remain intact while the channel is broken out to the external T1 port. The serial interface is not usable during the time the T1 channel is broken out to the external T1 port; however, the configuration remains to facilitate the return of the T1 channel to a serial interface with the no t1 external command.
Configuring the T1 Test Port on a PA-CT3/4T1 Port Adapter

The following controller configuration commands are valid only to the T1 test port. Configure the T1 test port using the t1 test t1 test channel [linecode {b8zs | ami}] [cablelength feet] command, where the T1 test channels are 1-28, and the cable length range is 0-655 feet. The default values are as follows: line code is B8ZS; cable length is 133 feet.

(Use the show controller t3 command to check the status of the test port; refer to the example of this command on page 34 of the section "Command Descriptions and Examples".)

For example, bring T1 20 to the test port as follows:

Router(config-controll)# t1 test 20 lincecode ami cablelength 300

Note For both the t1 external t1 channel [linecode {b8zs | ami}] [cablelength  feet] and t1 test t1 test channel [linecode {b8zs | ami}] [cablelength feet] commands, user-specified T1 cable lengths are structured into ranges as follows: 0-133, 134-266, 267-399, 400-533, and 534-655. If a cable length value is entered, which falls into one of these ranges, the range within which that value applies will be used.

In the preceding example, a cable length of 300 is specified. If it is changed to 350, then the 267-399 range applies in each case. Further, if a cable length of 550 is specified, then is changed to 600, the 534-655 range applies in each case; therefore, in each example, these changes have no effect. Only moving from one range to another has an effect. The actual number you enter is stored in the configuration file.

To remove a T1 port from the test port, use the no t1 test t1 test channel command, where T1 test channels are 1-28.

For example, remove T1 20 from the test port as follows:

Router(config-controll)# no t1 test 20

Note If a T1 channel that was previously configured as a serial interface is broken out to the T1 test port, that interface and its associated configuration remain intact while the channel is broken out to the T1 test port. The serial interface is not usable during the time the T1 channel is broken out to the T1 test port; however, the configuration remains to facilitate the return of the T1 channel to a serial interface with the no t1 test command.

Additional Commands for PA-CT3/4T1 Port Adapter Configuration

Following are additional commands required to complete the PA-CT3/4T1 port adapter configuration:

Step 1 Assign an IP address and subnet mask to the interface with the ip address configuration subcommand as in the following example:

Step 2 Add any additional interface subcommands required to enable routing protocols and adjust the interface characteristics.

Step 3 After including all of the interface subcommands to complete the configuration, press  Ctrl-Z (hold down the Control key while you press Z) to exit the configuration mode.

Step 4 Write the new configuration to memory as follows:

The system displays an OK message when the configuration is stored.

Step 5 Exit the privileged level and return to the user level by entering disable at the prompt as follows:

Proceed to the following section to check the interface configuration with show commands.

Checking the Configuration

After configuring the new interface, use the show commands to display the status of the new interface or all interfaces. Using the show controller T3 slot/port:t1 channel command, display T3 or T1 channel information as follows, where the T1 channel is 1-28:

					Router# show controller t3 5/0


Router					# show controller t3 5/0:5


Router# show controller t3 5/0 remote performance


Router					# show controller t3 5/0 brief

Command Descriptions and Examples

Following are descriptions and examples of the show commands. Descriptions are limited to fields that are relevant for verifying the configuration.

Following is an example from a Cisco 7206 router:
Router# show version
Cisco Internetwork Operating System Software 
IOS (tm) 7200 Software (C7200-P-M), Version 11.1.16(CA) [jkui 165]
Synced to mainline version: 11.1(12.1)
Copyright (c) 1986-1997 by cisco Systems, Inc.
Compiled Mon 30-Jun-97 08:45 by jkui
Image text-base: 0x600088D0, data-base: 0x604D2000
ROM: System Bootstrap, Version 11.1(5) [mkamson 5], RELEASE SOFTWARE (fc1)
ROM: 7200 Software (C7200-BOOT-M), Version 11.1.16(CA) [lali 189]
ct3-sw1 uptime is 2 hours, 34 minutes
System restarted by reload
System image file is "jkui/c7200-p-mz", booted via tftp from 171.69.209.28
cisco 7206 (NPE150) processor with 26624K/6144K bytes of memory.
R4700 processor, Implementation 33, Revision 1.0 (512KB Level 2 Cache)
Last reset from power-on
X.25 software, Version 2.0, NET2, BFE and GOSIP compliant.
4 Ethernet/IEEE 802.3 interfaces.
2 Serial network interfaces.
1 FDDI network interface.
125K bytes of non-volatile configuration memory.
1024K bytes of packet SRAM memory.
          
4096K bytes of Flash internal SIMM (Sector size 256K).
Configuration register is 0x0
Router# show cont t3 5/0
T3 5/0 is up.
  Applique type is Channelized T3
  No alarms detected.
  Framing is C-BIT Parity, Line Code is B3ZS, Clock Source is Line.
  Data in current interval (120 seconds elapsed):
     1 Line Code Violations, 2 P-bit Coding Violation
     3 C-bit Coding Violation
     4 P-bit Err Secs, 5 P-bit Severely Err Secs
     6 Severely Err Framing Secs, 7 Unavailable Secs
     8 Line Errored Secs, 9 C-bit Errored Secs, 10 C-bit Severely Errored Secs
  Data in Interval 1:
     10 Line Code Violations, 12 P-bit Coding Violation
     0 C-bit Coding Violation
     14 P-bit Err Secs, 15 P-bit Severely Err Secs
     16 Severely Err Framing Secs, 17 Unavailable Secs
     18 Line Errored Secs, 19 C-bit Errored Secs, 20 C-bit Severely Errored Secs
  Data in Interval 2:
     10 Line Code Violations, 12 P-bit Coding Violation
     0 C-bit Coding Violation
     14 P-bit Err Secs, 15 P-bit Severely Err Secs
     16 Severely Err Framing Secs, 17 Unavailable Secs
     18 Line Errored Secs, 19 C-bit Errored Secs, 20 C-bit Severely Errored Secs
  Data in Interval 3:
     10 Line Code Violations, 12 P-bit Coding Violation
     0 C-bit Coding Violation
     14 P-bit Err Secs, 15 P-bit Severely Err Secs
     16 Severely Err Framing Secs, 17 Unavailable Secs
     18 Line Errored Secs, 19 C-bit Errored Secs, 20 C-bit Severely Errored Secs
  T1 0, speed: 1536 kbs
  timeslots: 1-24
  No alarms detected.
  Framing is ESF, LineCode is AMI, Clock Source is Line.
  Data in current interval (180 seconds elapsed):
     2 Line Code Violations, 1 Path Code Violations
     7 Slip Secs, 5 Fr Loss Secs, 8 Line Err Secs, 10 Degraded Mins
     3 Errored Secs, 9 Bursty Err Secs, 4 Severely Err Secs, 6 Unavail Secs
  Data in Interval 1:
     12 Line Code Violations, 11 Path Code Violations
     17 Slip Secs, 15 Fr Loss Secs, 18 Line Err Secs, 20 Degraded Mins
     13 Errored Secs, 19 Bursty Err Secs, 14 Severely Err Secs, 16 Unavail Secs
  Data in Interval 2:
     12 Line Code Violations, 11 Path Code Violations
     17 Slip Secs, 15 Fr Loss Secs, 18 Line Err Secs, 20 Degraded Mins
     13 Errored Secs, 19 Bursty Err Secs, 14 Severely Err Secs, 16 Unavail Secs
  Data in Interval 3:
     12 Line Code Violations, 11 Path Code Violations
     17 Slip Secs, 15 Fr Loss Secs, 18 Line Err Secs, 20 Degraded Mins
     13 Errored Secs, 19 Bursty Err Secs, 14 Severely Err Secs, 16 Unavail Secs
  T1 1, speed: 1536 kbs
  timeslots: 1-24
  No alarms detected.
  Framing is ESF, LineCode is AMI, Clock Source is Line.
  Data in current interval (250 seconds elapsed):
     2 Line Code Violations, 1 Path Code Violations
     7 Slip Secs, 5 Fr Loss Secs, 8 Line Err Secs, 10 Degraded Mins
     3 Errored Secs, 9 Bursty Err Secs, 4 Severely Err Secs, 6 Unavail Secs
  Data in Interval 1:
     12 Line Code Violations, 11 Path Code Violations
     17 Slip Secs, 15 Fr Loss Secs, 18 Line Err Secs, 20 Degraded Mins
     13 Errored Secs, 19 Bursty Err Secs, 14 Severely Err Secs, 16 Unavail Secs
  Data in Interval 2:
     12 Line Code Violations, 11 Path Code Violations
     17 Slip Secs, 15 Fr Loss Secs, 18 Line Err Secs, 20 Degraded Mins
     13 Errored Secs, 19 Bursty Err Secs, 14 Severely Err Secs, 16 Unavail Secs
  Data in Interval 3:
     12 Line Code Violations, 11 Path Code Violations
     17 Slip Secs, 15 Fr Loss Secs, 18 Line Err Secs, 20 Degraded Mins
     13 Errored Secs, 19 Bursty Err Secs, 14 Severely Err Secs, 16 Unavail Secs 
Router#
Router# show cont t3
(additional displayed text omitted from this example)
  Ext1: LOS, Ext2: LOS, Ext3: LOS, Test: OK 
The information in the preceding example is displayed even if the external or test ports are not configured, which allows you to determine the health of the external equipment and cabling before configuring the external or test ports.
Following are explanations of the individual fields in this line:

  • LOS: loss of signal indicates that the port is not receiving a valid signal, and is the expected state if nothing is connected to the port.

  • AIS: alarm indication signal indicates that the port is receiving an all-ones signal.

  • OK: this indicates that a valid signal is being received and that this signal is not an all-ones signal. (This condition is opposite that indicated by AIS.)

An example follows:
Router# show controller t3 3/0 brief
T3 3/0 is up.
  CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 0.7.0
  Mxt H/W version : 2, Mxt ucode ver : 1.24
  Applique type is Channelized T3
  No alarms detected.
  FEAC code received : No code is being received
  Framing is C-BIT Parity, Line Code is B3ZS, Clock Source is Internal.
  T1 0 is up, speed: 1536 kbs, non-inverted data
  timeslots: 1-24
  No alarms detected.
  Framing is ESF, LineCode is B8ZS, Clock Source is Internal.
  T1 1 is up, speed: 1536 kbs, non-inverted data
  timeslots: 1-24
  No alarms detected.
  Framing is ESF, LineCode is B8ZS, Clock Source is Internal.
  T1 2 is up, speed: 1536 kbs, non-inverted data
  timeslots: 1-24
  No alarms detected.
  Framing is ESF, LineCode is B8ZS, Clock Source is Internal.
An example follows:
Router# sh cont t3 3/0:1 brief
T3 3/0 is up.
  CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 0.7.0
  Mxt H/W version : 2, Mxt ucode ver : 1.24
  Applique type is Channelized T3
  No alarms detected.
  FEAC code received : No code is being received
  Framing is C-BIT Parity, Line Code is B3ZS, Clock Source is Internal.
  T1 1 is up, speed: 1536 kbs, non-inverted data
  timeslots: 1-24
  No alarms detected.
  Framing is ESF, LineCode is B8ZS, Clock Source is Internal.
Router# show protocols
Serial3/0:0 is up, line protocol is up
  Internet address is 30.30.30.2/24
Serial3/0:1 is up, line protocol is up
  Internet address is 1.1.1.2/24
Router# show startup-config
controller T3 3/0
 cablelength 224
 t1 0 timeslots 1-24
 t1 1 timeslots 1-24
 t1 2 timeslots 1-24
!
interface Serial 3/0:0
 ip address 30.30.30.2 255.255.255.0
 no ip route-cache optimum
 no keepalive
 no fair-queue
!
interface Serial 3/0:1
 ip address 1.1.1.2 255.255.255.0
 no ip route-cache optimum
 no keepalive
 no fair-queue
!
interface Serial 3/0:2
 ip address 2.2.2.2 255.255.255.0
 no ip route-cache optimum
 no keepalive
 no fair-queue
!
(additional display text omitted from this example)

Using Show Commands to Verify the PA-CT3/4T1 Port Adapter Status

The following procedure summarizes how to use the show commands to verify that a new PA-CT3/4T1 port adapter interface is configured correctly:

Step 1 Use the show version command to display the system hardware configuration. Ensure that the list includes the new PA-CT3/4T1 port adapter network interface.

Step 2 Display the T1 alarm condition with the show controllers T3 command.

Step 3 Specify the new interface with the show interfaces command and verify that the first line of the display specifies the serial interface with the correct slot, port adapter, and port. Also verify that the interface and line protocol are in the correct state: up or down.

Step 4 Display the protocols configured for the entire system and specific interfaces with the command show  protocols. If necessary, return to the configuration mode to add or remove protocol routing on the system or specific interfaces.

Step 5 Display the entire system configuration file with the show  running-config and show startup-config commands. Verify that the configuration is accurate for the system and each interface.

If the interface is down and you configured it as up, or if the displays indicate that the hardware is not functioning properly, ensure that the network interface is properly connected and terminated.

This completes the configuration procedure for the new PA-CT3/4T1 port adapter interface.

Testing and Troubleshooting the PA-CT3/4T1 Port Adapter

Following are suggested guidelines for troubleshooting the PA-CT3/4T1 port adapter using the loopback command, LED indications, a bit error test (BERT), FDL performance reports, and for displaying remote performance reports.

Using loopback Commands

Should you have difficulty with the PA-CT3/4T1 port adapter configuration or installation, you can troubleshoot the PA-CT3/4T1 port adapter using the loopback command. Specify loopback for a T1 channel using the t1 channel loopback command, where the T1 channel is 1-28. There are three main loopback modes as follows: local, network (both line and payload), and remote (line and payload). Specify the loopback format using the loopback [local | network | remote] command.


Note To shut down the T3 interface, use the shutdown command at the controller prompt.

Examples of specific loopback modes follow:

			Router# config t
Enter configuration commands, one per line. End with CNTL/Z.
						Router(config)# interface serial 3/0:1
			Router(config-if)# loopback local	

In the preceding example, local loopback loops the router output data back toward the router at the T1 framer and sends an AIS signal out toward the network.
									Router# config t
Enter configuration commands, one per line. End with CNTL/Z.
			Router(config)# interface serial 3/0:1
						Router(config-if)# loopback network line
	
In the preceding example, network line loopback loops the data back toward the network (before the T1 framer).
									Router# config t
Enter configuration commands, one per line. End with CNTL/Z.
			Router(config)# interface serial 3/0:1
						Router(config-if)# loopback network payload

In the preceding example, network payload loopback loops just the payload data back toward the network at the T1 framer.
loopback [remote {line {fdl ansi | inband} | payload fdl ansi}]
Set the first T1 into remote line inband loopback, as follows:
Router# config t
Enter configuration commands, one per line.  End with CNTL/Z.
Router(config)# int serial 3/0:1
Router(config-if)# loop remote line inband

In the preceding example, remote line inband loopback sends a repeating 5-bit inband pattern (of 00001) to the remote end requesting that it enter into a network line loopback.
Set the first T1 into remote line FDL ANSI bit loopback, as follows:
Router# config t
Enter configuration commands, one per line.  End with CNTL/Z.
Router(config)# int serial 3/0:1
Router(config-if)# loop remote line fdl ansi

In the preceding example, remote line FDL ANSI bit loopback sends a repeating 16-bit ESF data link code word (of 00001110 11111111) to the remote end requesting that it enter into a network line loopback.
Set the first T1 into remote payload FDL ANSI bit loopback, as follows:
Router# config t
Enter configuration commands, one per line.  End with CNTL/Z.
Router(config)# int serial 3/0:1
Router(config-if)# loop remote payload fdl ansi

In the preceding example, remote payload ANSI bit loopback sends a repeating 16-bit ESF data link code word (of 00010100 11111111) to the remote end requesting that it enter into a network payload loopback.
Using Status and Alarm LED Indications

Following are various system states and functions that are reflected by the front-panel alarm and status LEDs on the PA-CT3/4T1 port adapter during the CPU boot process and microcode download.

    1 After the PA-CT3/4T1 port adapter CPU has booted successfully, the alarm and status LEDs goes on.

    2 When the PA-CT3/4T1 port adapter microcode download begins, the alarm LED goes off while the status LED flashes on and off.

    3 After the PA-CT3/4T1 port adapter microcode is downloaded (and before the PA-CT3/4T1 port adapter microcode image boots) the status LED goes off.


Note After the PA-CT3/4T1 port adapter microcode is booted, the microcode takes over control of the LEDs.

During the system bootup process and microcode download, the following LED error indications might appear:

In all the preceding error modes, the CPU continually loops and the system does not proceed to the microcode download.

Checking Bit Errors Using a BERT

To check bit errors using a bit error test (BERT), use the following command:

[no] t1 t1 channel bert pattern {2^15 | 2^20 | 2^23 | 0s | 
1s} interval minutes

where t1 channel is 1-28, 2^15 is an exponential number that represents a pseudo-random repeating pattern that is 32767 bits long, 2^20 is a pseudo-random repeating pattern that is 1048575 bits long, 2^23 is a pseudo-random repeating pattern that is 8388607 bits long, 0s is a pattern of all zeroes (00000000...), 1s is a pattern of all 1s (111111...), and minutes are 1-14400, which designate the time the BERT will run. To stop the BERT, use the optional no form of the command. Following is an example of this command, where the pseudo-random pattern 2^20 is sent and repeats on the first T1 channel for 60 minutes:

Router# t1 1 bert pattern 2^20 interval 60

Note that the BERT command is not saved in NVRAM. The test patterns from the PA-CT3/4T1 port adapter are framed test patterns; therefore, they are inserted into the payload of a framed T1 signal.

To display the BERT results, use the following EXEC commands: sh cont t3 number or sh cont t3 number brief. Following are examples of displaying BERT results output:

    1 Display BERT output results during a test, as follows:

Router# sh cont t3 5/0 b
T3 5/0 is up.
  CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 20.2.0
  Mx H/W version : 2, Mx ucode ver : 1.25
  Applique type is Channelized T3
  No alarms detected.
  FEAC code received : No code is being received
  Framing is M23, Line Code is B3ZS, Clock Source is Internal.
  T1 1 is down, speed: 1536 kbs, non-inverted data
  timeslots: 1-24
  FDL per ANSI T1.403 and AT&T 54016 spec.
  Configured for FDL Remotely Line Looped
  No alarms detected.
  Framing is ESF, Line Code is B8ZS, Clock Source is Internal.
  BERT test result (running)
      Test Pattern : All 0's, Status : Sync, Sync Detected : 1
      Interval : 4 minute(s), Time Remain : 4 minute(s)
      Bit Errors(Sync BERT Started) : 0 bits
      Bit Errors(Sync last Sync) : 0 bits , Bits Received : 7 Mbits

Note When the T1 is under BERT, its line state is down. When under BERT (in the running state), the "Total Bit Errors" value is not valid if the "Status" field is "Not Sync."

    2 When the test is done, display BERT results output as follows:

Router# sh cont t3 5/0 b
T3 5/0 is up.
  CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 20.2.0
  Mx H/W version : 2, Mx ucode ver : 1.25
  Applique type is Channelized T3
  No alarms detected.
  FEAC code received : No code is being received
  Framing is M23, Line Code is B3ZS, Clock Source is Internal.
  T1 1 is up, speed: 1536 kbs, non-inverted data
  timeslots: 1-24
  FDL per ANSI T1.403 and AT&T 54016 spec.
  Configured for FDL Remotely Line Looped
  No alarms detected.
  Framing is ESF, Line Code is B8ZS, Clock Source is Internal.
  BERT test result (done)
      Test Pattern : All 0's, Status : Not Sync, Sync Detected : 1
      Interval : 4 minute(s), Time Remain : 0 minute(s)
      Bit Errors(Sync BERT Started) : 0 bits
      Bit Errors(Sync last Sync) : 0 bits , Bits Received : 368 Mbits

Note The "Status" field is irrelevant when the BERT is done. If the "Sync Detected" counter is 0, the Bit Errors fields have no meaning.

    3 When the test is stopped prematurely, display BERT results output as follows:

Router# sh cont t3 5/0 b
T3 5/0 is up.
  CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 20.2.0
  Mx H/W version : 2, Mx ucode ver : 1.25
  Applique type is Channelized T3
  No alarms detected.
  FEAC code received : No code is being received
  Framing is M23, Line Code is B3ZS, Clock Source is Internal.
  T1 1 is up, speed: 1536 kbs, non-inverted data
  timeslots: 1-24
  FDL per ANSI T1.403 and AT&T 54016 spec.
  Configured for FDL Remotely Line Looped
  No alarms detected.
  Framing is ESF, Line Code is B8ZS, Clock Source is Internal.
  BERT test result (done)
      Test Pattern : All 0's, Status : Not Sync, Sync Detected : 1
      Interval : 4 minute(s), Time Remain : 2 minute(s) (unable to complete)
      Bit Errors(Sync BERT Started) : 0 bits
      Bit Errors(Sync last Sync) : 0 bits , Bits Received : 368 Mbits

Note In the preceding three examples, the "Sync Detected" counter indicates the number of times the pattern sync is detected (from No Sync to Sync), the "Bit Errors(Sync BERT Started)" counter indicates the number of bit errors during BERT, and the "Bit Errors(Sync last Sync)" counter shows the number of bit errors since the last pattern sync is detected.
Enabling Performance Reports

To enable and disable one-second transmissions of performance reports via the FDL (per ANSI T1.403), use the [no] t1 t1 channel fdl ansi command, where the T1 channel is 1-28.


Note This command can only be used only when the T1 framing is ESF. Use the no form of the command to disable remote performance reports.
Displaying Remote Performance Reports

To display remote (far-end) performance data, use the show controller t3 5/0 remote performance command, as follows:

Router# sh cont t3 5/0 remote performance 
T3 5/0 is up.
  CT3 H/W Version : 4, CT3 ROM Version : 0.116, CT3 F/W Version : 20.2.0
  Mx H/W version : 2, Mx ucode ver : 1.25
  T1 1 - Remote Performance Data
  Data in current interval (356 seconds elapsed):
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs
  Data in Interval 1:
     1 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     2 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs
  Data in Interval 2:
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs
  Total Data (last 2 15 minute intervals):
     1 Path Code Violations
     1 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     2 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs
  T1 2 - Remote Performance Data
  Data in current interval (425 seconds elapsed):
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs
  Data in Interval 1:
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs
  Data in Interval 2:
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs
  Total Data (last 2 15 minute intervals):
     0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs

FCC Class A Compliance

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.

You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures:

Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product.

Cisco Connection Online

Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.

Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.

CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.

You can access CCO in the following ways:

For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.

If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco's Technical Assistance Center (TAC) at 800  553-2447, 408  526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800  553-6387, 408  526-7208, or cs-rep@cisco.com.



hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1998 © Cisco Systems Inc.