Table of Contents
INDEX
- ? command 4-15
- 75-ohm coaxial cables
- available lengths 3-13, 3-16, C-25, C-28
- compliance requirements 3-13, C-25
- using 3-13, 3-16
- AC circuit breaker warning 2-5, 2-13
- AC power
- cable strain relief 3-26
- voltage requirements 1-6
- acronyms
- list of xvi
- ACT LEDs
- description 1-44
- activity LEDs
- See ACT LEDs
- adapter pinouts C-3
- addresses
- MAC layer 1-36
- AE3 ports
- cables C-27
- configuring 4-23
- connecting 3-16
- receptacles C-27
- air temperature 1-45
- airflow
- caution 1-6, 1-27, 1-32, 2-11
- requirements 1-45
- specifications B-1
- AIS LEDs
- description 1-12, 1-14, 1-20, 1-22
- See also model names, such as Cisco 7120-4T1
- Alarm Indication Signal LEDs
- See AIS LEDs
- AT3 ports
- cables C-27
- configuring 4-23
- connecting 3-16
- defaults 4-24
- receptacles C-27
- ATM ports
- cables C-27
- configuring 4-23
- defaults 4-23
- receptacles C-27
- See also AE3 ports or AT3 ports
- attenuation C-31
- AutoInstall
- using to configure 4-5
- auxiliary ports
- cables C-4
- connecting 2-19, 3-21
- connecting modem 3-23
- considerations 2-18
- description 1-4, 1-41
- pinouts C-3, C-4
- settings 3-23
- specifications B-1
- bandwidth points
- PCI bus guidelines 1-38
- port adapter guidelines A-1
- basic configuration
- procedures 4-1 to 4-26
- baud rate
- console port 3-21
- blank port adapters
- caution 1-27
- installing 2-9
- blank service module
- caution 1-32
- boot image
- location 1-41
- boot ROM
- network processor card 1-41
- replacement instructions 1-26
- brackets
- attaching 3-3
- back panel forward 3-4
- front panel forward 3-4
- Break function 4-34
- bus
- PCI description 1-6
- cables
- AE3 ports C-27
- AT3 port C-27
- auxiliary port C-4
- Category 3 or 5 UTP RJ-45 C-5
- Cisco 7120-4T C-6
- coaxial 3-13, 3-16, C-25, C-28
- console port C-2
- crossover 3-9, C-5
- distance for serial cables C-10
- E3 port C-25
- EIA/TIA-612 and -613 C-25
- Fast Ethernet ports C-5
- fiber-optics specifications C-30
- interference 2-14
- MM3 ports C-29
- OC-3 ATM C-29
- power supply B-1
- RJ-45-to-DB-25 DCE adapter C-1
- RJ-45-to-DB-25 DTE adapter C-1
- RJ-45-to-DB-9 DTE adapter C-1
- rollover cable C-2
- safety guidelines 2-6
- SMI3 ports C-29
- straight-through C-5
- swapping power 5-6
- T3 ports C-25
- ungrounded and uninsulated 2-6
- cache memory
- description 1-41
- carrier detect LEDs
- See CD LEDs
- Category 3 or 5 UTP
- crossover cables 3-9
- RJ-45 cables C-5
- cautions
- airflow 1-6, 1-27
- changing passwords 4-36, 4-38
- chassis overheating 1-47, 2-11
- CPU reset button 1-43
- ESD wrist-strap safety 2-6
- serial interface cables 3-12, C-7
- CD LEDs
- description 1-10
- chassis
- placement guidelines 3-1
- slot number 1-33
- tabletop mounting 1-7, 3-1
- weight B-1
- chassis lifting
- warning 2-7
- chromatic dispersion C-32
- Cisco 7120 series
- back view (figure) 1-5
- models 1-7
- overview 1-7
- slot numbering 1-34
- Cisco 7120-4T1
- back view 1-8
- cables C-6
- connecting 3-11
- description 1-8
- encapsulation 1-8
- LEDs 1-9
- pinouts C-6
- Cisco 7120-AE3
- back view 1-16
- description 1-14
- features 1-14
- LEDs 1-17
- Cisco 7120-AT3
- back view 1-15
- description 1-14
- features 1-14
- LEDs 1-17
- Cisco 7120-E3
- back view 1-13
- description 1-12
- features 1-12
- LEDs 1-13
- Cisco 7120-SMI3
- back view 1-16
- description 1-14
- features 1-14
- LEDs 1-17
- Cisco 7120-T3
- back view 1-11
- description 1-10
- features 1-10
- LEDs 1-11
- Cisco 7140 series
- back view 1-5
- models 1-18
- overview 1-18
- slot numbering 1-34
- Cisco 7140-2AE3
- back view 1-24
- description 1-22
- features 1-22
- LEDs 1-25
- Cisco 7140-2AT3
- back view 1-23
- description 1-22
- features 1-22
- LEDs 1-25
- Cisco 7140-2E3
- back view 1-21
- description 1-20
- features 1-20
- LEDs 1-21
- Cisco 7140-2MM3
- back view 1-24
- description 1-22
- features 1-22
- LEDs 1-25
- Cisco 7140-2T3
- back view 1-19
- description 1-18
- features 1-18
- LEDs 1-19
- Cisco IOS software image
- boot ROM 1-41
- Flash Disk and Flash memory 1-27
- show version command 1-43
- CiscoView
- description 1-3
- CiscoWorks
- description 1-3
- clearance
- chassis guidelines 2-11
- intake and exhaust ports 2-11
- clock source command 4-20, 4-22, 4-25
- clockrate command 4-18
- coaxial cables
- available lengths 3-16, C-28
- compliance requirements 3-13, C-25
- using 3-13, 3-16
- commands
- clock source 4-20, 4-22, 4-25
- clockrate 4-18
- config-register 4-37
- configure 4-12
- configure memory 4-37
- configure terminal 4-37
- confreg 4-35
- copy running-config 4-26
- copy running-config startup-config 4-38
- ctrl-z 4-15
- dsu bandwidth 4-20, 4-22
- enable 4-13, 4-36
- enable password 4-37
- enable secret 4-37
- end 4-15
- half-duplex 4-15
- interface atm 4-25
- interface fastethernet 4-15
- interface serial 4-17, 4-19, 4-22
- ip address 4-15, 4-17, 4-20, 4-22, 4-25
- line con 0 4-37
- loopback 3-15
- media-type 4-15
- no shutdown 4-16, 4-18, 4-20, 4-23, 4-26, 4-37
- password 4-37
- reload 4-38
- reset 4-35
- setup 4-3
- show diag 4-31
- show environment 1-47, 2-8, 5-9
- show environment table 5-9
- show interfaces 1-35, 4-29
- show running-config 4-26
- show startup-config 4-26, 4-34, 4-36
- show version 1-43, 4-5, 4-30
- shutdown 3-11
- using ? 4-15
- compliance
- specifications B-1
- components
- Cisco 7100 series 1-4
- network processor card 1-40
- config-register command 4-37
- configure command 4-12
- configure memory command 4-37
- configure terminal command 4-37
- configuring
- ATM port 4-23
- AutoInstall 4-5
- checking settings 4-26
- configure command 4-12
- E1 ports 4-16
- E3 ports 4-21
- Fast Ethernet port 4-14
- reviewing changes 4-26
- router 4-4
- sample file 4-11
- saving settings 4-12
- saving to NVRAM 4-26
- setup facility 4-6
- software 4-1
- T1 ports 4-16
- T3 ports 4-19
- viewing settings 4-30
- confreg command 4-35
- console port 1-4, 1-41
- cables C-2
- connecting 3-21
- considerations 2-18
- pinouts C-2
- settings 2-18, 3-21
- specifications B-1
- console terminal
- system banner display 5-6
- cooling subsystem
- troubleshooting 5-8
- cooling subsystems
- description 5-4
- copy running-config command 4-26
- copy running-config startup-config command 4-38
- CPU reset button
- caution 1-43
- location 1-44
- critical conditions
- monitoring 1-46
- crossover cables
- identifying C-5
- ctrl-z command 4-15
- data bits
- console port 3-21
- data terminal equipment
- See DTE
- defaults
- AT3 ports 4-24
- E1 ports 4-16
- E3 ports 4-21
- Fast Ethernet 4-14
- T1 ports 4-16
- T3 ports 4-19
- dimensions
- chassis B-1
- distance limitations
- fiber-optic cable C-31
- transmission 2-15
- double pole/neutral fusing
- warning 3-24
- downloading software 1-3
- DSU
- feature compatibilities C-26
- dsu bandwidth command 4-20, 4-22
- DTE
- auxiliary ports 2-19
- E1 ports
- configuring 4-16
- defaults 4-16
- E3 ports
- cables C-25
- configuring 4-21
- connecting 3-13
- connecting requirements 3-13, C-25
- defaults 4-21
- DSU compatibilities C-26
- EEPROM
- MAC address bank 1-37
- EIA/TIA-232 cables
- Cisco 7120-4T1 C-8
- overview C-10
- EIA/TIA-449 cables
- Cisco 7120-4T1 C-8
- overview C-13
- EIA/TIA-612
- serial cable conforms to C-25
- EIA/TIA-613
- serial cable conforms to C-25
- EIA-530 cables
- Cisco 7120-4T1 C-8
- overview C-23
- electrical equipment guidelines 2-4
- electromagnetic compliance
- See EMC
- electromagnetic pulse
- See EMP
- electrostatic discharge
- See ESD
- EMC
- specifications B-2
- EMP
- avoiding 2-15
- enable command 4-13, 4-36
- enable password command 4-37
- enable secret command 4-37
- enabled LEDs
- Cisco 7120-4T1 1-9
- Cisco 7120-AE3 1-17
- Cisco 7120-AT3 1-17
- Cisco 7120-E3 1-13
- Cisco 7120-SMI3 1-17
- Cisco 7120-T3 1-11
- Cisco 7140-2AE3 1-25
- Cisco 7140-2AT3 1-25
- Cisco 7140-2E3 1-21
- Cisco 7140-2MM3 1-25
- Cisco 7140-2T3 1-19
- function 5-5
- ISM 1-31
- troubleshooting 5-8
- encapsulation
- Cisco 7120-4T1 1-8
- encryption
- feature description 1-3
- end command 4-15
- environmental monitoring
- description 1-45
- feature 1-3
- logs 1-41
- power thresholds 1-46
- sensors 1-41
- environmental specifications 2-12
- equipment racks
- See racks
- ESD
- location 1-6
- preventing 2-6
- wrist straps 2-7
- Ethernet connections 2-16
- export laws
- ISM 1-31
- external timing signals 1-8
- fans
- description 1-6
- failures 1-50
- troubleshooting 5-8
- Far End Receive Failure LEDs
- See FERF LEDs
- Fast Ethernet ports
- cables C-5
- configuring 4-14
- connecting 3-9
- defaults 4-14
- pinouts C-5
- features
- Cisco 7120-4T1 1-8
- Cisco 7120-AE3 1-14
- Cisco 7120-AT3 1-14
- Cisco 7120-E3 1-12
- Cisco 7120-SMI3 1-14
- Cisco 7120-T3 1-10
- Cisco 7140-2AE3 1-22
- Cisco 7140-2AT3 1-22
- Cisco 7140-2E3 1-20
- Cisco 7140-2MM3 1-22
- Cisco 7140-2T3 1-18
- description 1-3
- network processor 1-39
- FERF LEDs
- description 1-12, 1-14, 1-20, 1-22
- See also model names, such as Cisco 7120-4T1
- ferrite beads 3-13, C-25
- fiber-optic cables
- distance limitations C-31
- power budget C-31
- specifications C-30
- field-replaceable units
- See FRUs
- fire risk warning 2-6
- fixed LAN
- LEDs 1-44
- ports 1-4, 1-42
- show interface command 1-35, 4-29
- show interfaces command 1-35
- slot numbering 1-33
- fixed WAN
- ports 1-4
- show interface command 1-35, 4-29
- show interfaces command 1-35
- slot numbering 1-33
- Flash Disks
- description 1-27
- memory options 1-29
- reformatting (note) 1-28
- replacing 1-28
- Flash memory cards
- description 1-27
- Flash memory SIMMs
- boot image 1-41
- replacing 1-26
- flow control
- auxiliary port 3-23
- footprints
- chassis 2-10
- FRUs
- description 1-26
- functional description
- environmental monitoring 1-45
- MAC address 1-37
- network processor 1-39
- OIR 1-3, 1-37
- overview 1-33
- PCI bus 1-38
- slot numbering 1-33
- system LEDs and reset button 1-43
- gravity
- maintaining low center 2-11
- ground conductor warning 2-13
- ground connections
- installing 3-5
- warning 2-5
- ground receptacles
- location 1-6
- grounded equipment warning 2-5
- grounding lugs 2-1
- description 3-5
- guidelines
- electrical equipment 2-4
- safety 2-3
- half-duplex command 4-15
- hardware address 1-36
- hardware flow control
- auxiliary port 3-23
- heat dissipation
- specifications B-1
- humidity
- requirements 2-12
- specifications B-1
- identifying startup problems 5-4
- incorrect connection warning 2-17
- installing
- chassis grounding 3-5
- preparing for 2-11
- reading instructions 2-1
- site requirements 2-8
- tools for 2-1
- Integrated Service Module
- See ISM
- interface atm command 4-25
- interface fastethernet command 4-15
- interface serial command 4-17, 4-19, 4-22
- interface slot numbering
- description 1-33
- interface types
- Cisco 7120-4T1 1-8
- show interface command 1-35, 4-29
- show interfaces command 1-35
- interference
- radio frequency 2-14
- internal fans 1-6
- internal timing signals 1-8
- ip address command 4-15, 4-17, 4-20, 4-22, 4-25
- IP Security Protocol
- See IPSec
- IPSec
- description 1-1, 1-30
- ISM
- airflow caution 1-32
- description 1-30
- export laws 1-31
- features 1-3, 1-4
- installing 1-32
- slot location 1-33
- jewelry
- avoiding for safety 2-3
- removal warning 2-4
- L2F/L2TP
- description 1-1
- LAN interfaces
- fixed ports 1-4
- LEDs 1-4
- show interface command 1-35, 4-29
- slot numbering 1-33
- specification B-1
- laser
- product warning 2-17, 3-19
- radiation warning 2-17, 3-19
- safety guidelines 2-17
- Layer 2 Forwarding and Layer 2 Tunneling Protocol
- See L2F/L2TP
- LB LEDs
- description 1-10
- LEDs
- at startup 5-5
- boot process 4-2
- Cisco 7120-4T1 1-9
- Cisco 7120-AE3 1-17
- Cisco 7120-AT3 1-17
- Cisco 7120-E3 1-13
- Cisco 7120-SMI3 1-17
- Cisco 7140-2AE3 1-25
- Cisco 7140-2AT3 1-25
- Cisco 7140-2E3 1-21
- Cisco 7140-2MM3 1-25
- Cisco 7140-2T3 1-19
- enabled 5-5, 5-8
- ISM 1-31
- PC Card slot 5-6
- power 5-6
- safety guidelines 2-17
- system LEDs 1-4, 1-43
- lifting
- safety guidelines 2-7
- lightning
- safety guidelines 2-6
- warning 3-9
- line con 0 command 4-37
- link LEDs
- See LNK LEDs
- link loss factors C-33
- lithium batteries 1-41
- LL LEDs
- description 1-12, 1-14, 1-20, 1-22
- See also models, such as Cisco 7120-4T1
- LNK LEDs
- description 1-44
- local loopback LEDs
- See LL LEDs
- logging in without a password 4-34
- loopback command 3-15
- loopback LEDs
- See LB LEDs
- loopbacks
- Cisco 7120-4T1 1-8
- lugs
- grounding parts needed 2-1, 3-5
- MAC addresses 1-36
- media-type command 4-15
- messages
- fan failure 2-8
- microprocessors
- RISC 1-40
- MM3 ports
- cables C-29
- receptacles C-29
- MM3/SMI3 ports
- power margin C-32
- signal requirements C-33
- modal dispersion C-32
- models
- Cisco 7120 series 1-7
- Cisco 7140 series 1-18
- See also model names, such as Cisco 7120-4T1
- modifying configurations
- reviewing 4-26
- modular port adapter
- show interface command 4-29
- modular port adapters
- show interface command 1-35
- show interfaces command 1-35
- slot numbering 1-33
- multimode connections
- cabling C-29
- description 3-19
- power budget (example) C-34
- network connections
- description 3-9
- Ethernet 2-16
- WAN 2-17
- network management
- description 1-3
- network processors
- component descriptions 1-40
- description 1-4
- environmental monitoring and reporting 1-45
- features 1-39
- field-replaceable units 1-29
- location of devices 1-40
- troubleshooting 5-7
- no shutdown command 3-11, 4-16, 4-18, 4-20, 4-23, 4-26, 4-37
- nonoperating specifications 2-12
- normal conditions
- monitoring 1-46
- notes
- AC power cable strain relief 3-26
- AC power supply voltage requirements 1-6
- Break function 4-34
- chassis ground connection 2-12, 2-14
- compliance 3-16
- correcting EMI 2-15
- logging in without a password 4-34
- power requirements 2-14
- recovering passwords 4-34
- temperature ranges 1-49
- transmission rates and distance limits 2-15
- numbering
- slots 1-33
- NVRAM
- description 1-41
- saving configuration 4-12, 4-26
- OC-3 ATM cables
- obtaining C-29
- using C-29
- OC-3c/STM-1 connections
- description 3-19
- OIR
- description 1-3, 1-37
- online insertion and removal
- See OIR
- OOF LEDs
- description 1-12, 1-14, 1-20, 1-22
- See also model names, such as Cisco 7120-4T1
- operating specifications 2-12
- Out of Frame LEDs
- See OOF LEDs
- overheating
- at startup 5-4
- caution 1-47, 2-11
- preventing 2-8
- packet memory
- description 1-29, 1-41
- size 1-4
- parity
- console port 3-21
- password command 4-37
- passwords
- changing caution 4-36, 4-38
- recovering lost 4-34
- PC Card slots
- Flash Disk 1-27
- Flash memory 1-27
- LEDs 1-44
- location 1-4
- memory types 1-42
- PCI bus
- description 1-6, 1-38, 1-40
- peripheral component interconnect bus
- See PCI bus
- pinouts
- auxiliary port C-4
- Cisco 7120-4T1 C-6
- console port C-2
- Fast Ethernet port C-5
- placement guidelines
- tabletop 3-1
- plant wiring
- guidelines 2-14
- plug-socket combination
- warning 3-25
- port adapters
- bandwidth points A-1
- installing blank 2-9
- installing blank (caution) 1-27
- overview 1-26
- replacing 1-26
- show interface command 1-35, 4-29
- show interfaces command 1-35
- slot location 1-33
- slot numbering 1-33
- troubleshooting 5-5, 5-8
- port numbers
- description 1-33
- ports
- auxiliary 1-4, 1-41
- console 1-4, 1-41
- LAN 1-4
- WAN 1-4
- power
- site requirements 2-14
- subsystem for troubleshooting 5-6
- surge suppression 2-15
- ungrounded 2-5
- power budget
- calculating C-33
- fiber-optics cable C-31
- multimode example C-34
- single-mode example C-35
- power connections
- guidelines 2-13
- warning 2-4
- power cords
- troubleshooting 5-6
- unplugging for safety 2-4
- power factor corrector 2-14
- power LEDs 1-4
- See PWR LEDs
- power margins
- calculating C-33
- power supply 5-5
- cables B-1
- connecting 3-24
- description 1-6
- feature 1-4
- LEDs 5-5
- power factor corrector 2-14
- specifications B-1
- troubleshooting 5-4
- voltage and temperature 1-45
- warning 2-4, 3-24
- power thresholds 1-47
- powering up
- guidelines 3-24
- procedures
- ATM E3 WAN port, connecting 3-17
- ATM OC-3c/STM-1 WAN port, connecting 3-19
- ATM T3 WAN port, connecting 3-17
- auxiliary port, connecting 3-23
- brackets, attaching 3-3
- chassis, grounding 3-5
- console port, connecting 3-21
- E3 WAN port, connecting 3-14
- LAN port, connecting 3-10
- power, connecting 3-25
- rack-mounting 3-3 to 3-4
- T3 WAN port, connecting 3-11, 3-14
- viewing system configuration 4-30
- processor subsystem
- description 5-4
- product description 1-1
- product disposal
- warning 2-4
- PWR LEDs 5-5, 5-6
- description 1-44
- QoS
- description 1-1
- quality of service
- See QoS
- rack-mount brackets 2-1
- rack-mount kits
- field-replaceable unit 1-32
- overview 1-7
- replacement instructions 1-26
- rack-mounting
- attaching brackets 3-3
- back panel forward 3-4
- brackets, standard 3-3
- front panel forward 3-4
- racks
- mounting guidelines 2-9
- radiation
- laser warning 2-17, 3-19
- RC LEDs
- description 1-10
- RCLK LEDs
- description 1-12, 1-14, 1-20, 1-22
- See also model names, such as Cisco 7120-4T1
- RD LEDs
- description 1-9
- receive alarm LEDs
- See RX ALM LEDs
- receive ATM cell LEDs
- See RX CEL LEDs
- receive carrier LEDs
- See RX CAR LEDs
- receive cell LEDs
- See RX CEL LEDs
- receive clock LED
- See RCLK LEDs
- receive clock LEDs
- See RC LEDs
- See RCLK LEDs
- receive data LEDs
- See RD LEDs
- receptacles
- AE3 ports C-27
- AT3 ports C-27
- MM3 port C-29
- MM3 ports C-29
- SMI3 ports C-29
- reload command 4-38
- remote loopback LEDs
- See RL LEDs
- replacing
- Flash Disk 1-28
- ISM service module 1-32
- port adapters 1-26
- rack-mount kit 1-26
- SDRAM memory 1-26
- reset buttons 1-43
- caution 1-43
- location 1-44
- reset command 4-35
- restricted access area
- warning 2-8
- reviewing changes to configuration 4-26
- RFC 1406 1-8
- RISC microprocessors 1-40
- RJ-45-to-DB-25 DCE adapters 3-21, C-1
- RJ-45-to-DB-25 DTE adapters 3-21, C-1
- RJ-45-to-DB-9 DTE adapters 3-21, C-1
- RJ-45-to-RJ-45 rollover cables 3-21, C-1
- RL LEDs
- description 1-12, 1-14, 1-20, 1-22
- See also model names, such as Cisco 7120-4T1
- rollover cables
- identifying C-2
- rubber feet
- attaching 3-2
- RX ALM LEDs 1-25
- description 1-17
- RX CAR LEDs 1-25
- description 1-17
- RX CEL LEDs 1-25
- description 1-17
- safety
- warnings translated xiv
- safety cover
- warning 2-3
- safety guidelines
- ESD prevention 2-6
- general 2-3
- laser and LED 2-17
- plant wiring 2-14
- power connections 2-13
- safety specifications B-2
- sample configuration 4-11
- saving configuration settings 4-26
- SDRAM memory
- description 1-4, 1-29
- options 1-30
- packet memory 1-41
- replacing 1-26
- system memory
- description 1-41
- sensors
- environmental monitoring 1-41
- serial interface cables
- caution 3-12, C-7
- service modules
- slot location 1-3, 1-33
- using blank 1-32
- service personnel warning 2-17
- settings
- console port 2-18
- setup command 4-3
- setup facility 4-6
- shipping containers
- contents 2-2
- show diag command 4-31
- show environment command 1-47, 2-8, 5-9
- show environment table 5-9
- show interface command 1-35, 4-29
- show interfaces command 1-35
- show running-config command 4-26
- show startup-config command 4-26, 4-34, 4-36
- show version command 1-43, 4-5, 4-30
- shutdown
- preventing administrative 4-37
- shutdown command 3-11
- Simple Network Management Protocol
- See SNMP
- single-mode connections C-29
- single-mode intermediate reach
- connecting 3-19
- single-mode power budget example C-35
- site requirements
- environment 2-12
- equipment racks 2-9
- guidelines 2-8
- plant wiring 2-14
- power 2-14
- slot 0
- fixed LAN interface 1-33
- slot 1 and 2
- fixed WAN interface 1-33
- slot 3 and 4
- modular port adapter slot 1-33
- slot 5
- service module 1-33
- slot LEDs 1-4, 1-44, 5-6
- slot numbering
- Cisco 7140 series (figure) 1-34
- description 1-33
- figure 1-34
- fixed LAN ports 1-4
- fixed WAN ports 1-4
- PC Card 1-4
- service module 1-4
- SMI3 ports
- cables C-29
- receptacles C-29
- SNMP
- description 1-3
- software configuration 4-4
- basic startup 4-1 to 4-26
- software image
- boot ROM 1-41
- Flash Disk and Flash memory 1-27
- show version command 1-43
- software recommended B-1
- SONET
- connections C-29
- distance limitations C-31
- power budget C-31
- power budget (example) C-34, C-35
- signal requirements C-33
- specifications
- airflow B-1
- auxiliary port B-1
- compliance B-1
- console port B-1
- dimensions B-1
- EMC B-2
- environmental 2-12
- heat dissipation B-1
- humidity B-1
- LAN interfaces B-1
- minimum software recommended B-1
- physical B-1
- power B-1
- power supply B-1
- safety B-2
- temperature B-1
- WAN ports B-1
- startup
- troubleshooting 5-4
- status
- environmental 2-8
- status LEDs
- Cisco 7120-4T1 1-9
- Cisco 7120-AE3 1-17
- Cisco 7120-AT3 1-17
- Cisco 7120-E3 1-13
- Cisco 7120-SMI3 1-17
- Cisco 7120-T3 1-11
- Cisco 7140-2AE3 1-25
- Cisco 7140-2AT3 1-25
- Cisco 7140-2E3 1-21
- Cisco 7140-2MM3 1-25
- Cisco 7140-2T3 1-19
- ISM 1-31
- stop bits
- console port 3-21
- straight-through cables
- identifying C-5
- subsystems for troubleshooting
- cooling 5-4, 5-8
- power 5-4, 5-6
- processor 5-4
- SYS RDY LEDs
- description 1-44
- troubleshooting 5-5, 5-7
- system
- configuration in NVRAM 1-41
- LED locations 1-44
- system controllers
- processor card 1-40
- system memory
- description 1-4, 1-29, 1-41
- system ready LEDs
- See SYS RDY LEDs
- system startup
- before startup 4-2
- T1 ports
- configuring 4-16
- connecting 3-11
- defaults 4-16
- T3 ports
- cables C-25
- configuring 4-19
- connecting 3-13
- defaults 4-19
- DSU compatibilities C-26
- tabletop mounting 1-7, 3-1
- TC LEDs
- description 1-9
- TD LEDs
- description 1-9
- telco-type equipment racks
- rack-mounting guidelines 2-9
- telephone jacks
- installing precautions 2-6
- telephone network cables
- warning 3-9
- temperature
- requirements for operation 2-12
- specifications B-1
- temperature thresholds 1-46
- terms and acronyms xvi
- thresholds
- power 1-47
- temperature 1-46
- timing signals 1-8
- tools
- for attaching ground connections 3-5
- for installing 2-1
- trained personnel
- warning 2-1
- translated safety warnings xiv
- transmission speeds
- configuring auxiliary port 3-23
- transmit clock LEDs
- See TC LEDs
- transmit data LEDs
- See TD LEDs
- troubleshooting
- cooling subsystem 5-8
- cooling subsystems 5-4
- LED descriptions
- Cisco 7120-4T1 1-9
- Cisco 7120-AE3 1-17
- Cisco 7120-AT3 1-17
- Cisco 7120-E3 1-14
- Cisco 7120-SMI3 1-17
- Cisco 7120-T3 1-12
- Cisco 7140-2AE3 1-25
- Cisco 7140-2AT3 1-25
- Cisco 7140-2E3 1-22
- Cisco 7140-2MM3 1-25
- Cisco 7140-2T3 1-20
- fixed LAN ports 1-44
- ISM 1-31
- PC Card slots 1-44
- system 1-44
- network processor 5-7
- overview 5-2
- port adapters 5-8
- ports 5-5
- power subsystem 5-6
- power supply 5-4, 5-6
- processor 5-4
- startup problems 5-4
- strategy 5-3
- V.35 cables
- Cisco 7120-4T1 C-8
- overview C-17
- Virtual Private Networks
- See VPNs
- VPNs
- description 1-1
- network example 1-2
- WAN interfaces
- show interface command 1-35, 4-29
- slot numbering 1-33
- WAN ports
- connecting 2-17
- connecting (warning) 2-17, 3-9
- fixed interface 1-4
- LEDs 1-4
- specifications B-1
- warning conditions
- monitoring 1-46
- warnings
- AC circuit breaker 2-5, 2-13
- chassis lifting 2-7
- double pole/neutral fusing 3-24
- fire risk 2-6
- ground conductor 2-13
- ground connection first 2-5
- grounded equipment 2-5
- incorrect connection 2-17
- installation instructions 2-1
- jewelry 2-3, 2-4
- laser products 2-17, 3-19
- laser radiation 2-17, 3-19
- ligtning activity 3-9
- plug-socket combination 3-25
- power connections 2-4
- power supply 2-4, 3-24
- product disposal 2-4
- read installation instructions 3-1
- restricted access area 2-8
- safety cover 2-3
- service personnel 2-17
- telephone-network cables 3-9
- trained personnel 2-1
- WAN connections 2-17, 3-9
- weight
- chassis B-1
- wiring
- interference 2-14
- plant 2-14
- telephone 2-6
- wrist straps
- attaching 2-7
- X.21 cable
- overview C-20
- X.21 cables
- Cisco 7120-4T1 C-8







Posted: Tue Jul 27 17:21:56 PDT 1999