cc/td/doc/product/core/7100
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

INDEX

INDEX

Symbols


? command     4-15

Numerics


75-ohm coaxial cables
available lengths     3-13, 3-16, C-25, C-28
compliance requirements     3-13, C-25
using     3-13, 3-16

A


AC circuit breaker warning     2-5, 2-13

AC power
cable strain relief     3-26
voltage requirements     1-6

acronyms
list of     xvi

ACT LEDs
description     1-44

activity LEDs
See ACT LEDs

adapter pinouts     C-3

addresses
MAC layer     1-36

AE3 ports
cables     C-27
configuring     4-23
connecting     3-16
receptacles     C-27

air temperature     1-45

airflow
caution     1-6, 1-27, 1-32, 2-11
requirements     1-45
specifications     B-1

AIS LEDs
description     1-12, 1-14, 1-20, 1-22
See also model names, such as Cisco 7120-4T1

Alarm Indication Signal LEDs
See AIS LEDs

AT3 ports
cables     C-27
configuring     4-23
connecting     3-16
defaults     4-24
receptacles     C-27

ATM ports
cables     C-27
configuring     4-23
defaults     4-23
receptacles     C-27
See also AE3 ports or AT3 ports

attenuation     C-31

AutoInstall
using to configure     4-5

auxiliary ports
cables     C-4
connecting     2-19, 3-21
connecting modem     3-23
considerations     2-18
description     1-4, 1-41
pinouts     C-3, C-4
settings     3-23
specifications     B-1

B


bandwidth points
PCI bus guidelines     1-38
port adapter guidelines     A-1

basic configuration
procedures     4-1  to 4-26

baud rate
console port     3-21

blank port adapters
caution     1-27
installing     2-9

blank service module
caution     1-32

boot image
location     1-41

boot ROM
network processor card     1-41
replacement instructions     1-26

brackets
attaching     3-3
back panel forward     3-4
front panel forward     3-4

Break function     4-34

bus
PCI description     1-6

C


cables
AE3 ports     C-27
AT3 port     C-27
auxiliary port     C-4
Category 3 or 5 UTP RJ-45     C-5
Cisco 7120-4T     C-6
coaxial     3-13, 3-16, C-25, C-28
console port     C-2
crossover     3-9, C-5
distance for serial cables     C-10
E3 port     C-25
EIA/TIA-612 and -613     C-25
Fast Ethernet ports     C-5
fiber-optics specifications     C-30
interference     2-14
MM3 ports     C-29
OC-3 ATM     C-29
power supply     B-1
RJ-45-to-DB-25 DCE adapter     C-1
RJ-45-to-DB-25 DTE adapter     C-1
RJ-45-to-DB-9 DTE adapter     C-1
rollover cable     C-2
safety guidelines     2-6
SMI3 ports     C-29
straight-through     C-5
swapping power     5-6
T3 ports     C-25
ungrounded and uninsulated     2-6

cache memory
description     1-41

carrier detect LEDs
See CD LEDs

Category 3 or 5 UTP
crossover cables     3-9
RJ-45 cables     C-5

cautions
airflow     1-6, 1-27
changing passwords     4-36, 4-38
chassis overheating     1-47, 2-11
CPU reset button     1-43
ESD wrist-strap safety     2-6
serial interface cables     3-12, C-7

CD LEDs
description     1-10

chassis
placement guidelines     3-1
slot number     1-33
tabletop mounting     1-7, 3-1
weight     B-1

chassis lifting
warning     2-7

chromatic dispersion     C-32

Cisco 7120 series
back view (figure)     1-5
models     1-7
overview     1-7
slot numbering     1-34

Cisco 7120-4T1
back view     1-8
cables     C-6
connecting     3-11
description     1-8
encapsulation     1-8
LEDs     1-9
pinouts     C-6

Cisco 7120-AE3
back view     1-16
description     1-14
features     1-14
LEDs     1-17

Cisco 7120-AT3
back view     1-15
description     1-14
features     1-14
LEDs     1-17

Cisco 7120-E3
back view     1-13
description     1-12
features     1-12
LEDs     1-13

Cisco 7120-SMI3
back view     1-16
description     1-14
features     1-14
LEDs     1-17

Cisco 7120-T3
back view     1-11
description     1-10
features     1-10
LEDs     1-11

Cisco 7140 series
back view     1-5
models     1-18
overview     1-18
slot numbering     1-34

Cisco 7140-2AE3
back view     1-24
description     1-22
features     1-22
LEDs     1-25

Cisco 7140-2AT3
back view     1-23
description     1-22
features     1-22
LEDs     1-25

Cisco 7140-2E3
back view     1-21
description     1-20
features     1-20
LEDs     1-21

Cisco 7140-2MM3
back view     1-24
description     1-22
features     1-22
LEDs     1-25

Cisco 7140-2T3
back view     1-19
description     1-18
features     1-18
LEDs     1-19

Cisco IOS software image
boot ROM     1-41
Flash Disk and Flash memory     1-27
show version command     1-43

CiscoView
description     1-3

CiscoWorks
description     1-3

clearance
chassis guidelines     2-11
intake and exhaust ports     2-11

clock source command     4-20, 4-22, 4-25

clockrate command     4-18

coaxial cables
available lengths     3-16, C-28
compliance requirements     3-13, C-25
using     3-13, 3-16

commands
clock source     4-20, 4-22, 4-25
clockrate     4-18
config-register     4-37
configure     4-12
configure memory     4-37
configure terminal     4-37
confreg     4-35
copy running-config     4-26
copy running-config startup-config     4-38
ctrl-z     4-15
dsu bandwidth     4-20, 4-22
enable     4-13, 4-36
enable password     4-37
enable secret     4-37
end     4-15
half-duplex     4-15
interface atm     4-25
interface fastethernet     4-15
interface serial     4-17, 4-19, 4-22
ip address     4-15, 4-17, 4-20, 4-22, 4-25
line con 0     4-37
loopback     3-15
media-type     4-15
no shutdown     4-16, 4-18, 4-20, 4-23, 4-26, 4-37
password     4-37
reload     4-38
reset     4-35
setup     4-3
show diag     4-31
show environment     1-47, 2-8, 5-9
show environment table     5-9
show interfaces     1-35, 4-29
show running-config     4-26
show startup-config     4-26, 4-34, 4-36
show version     1-43, 4-5, 4-30
shutdown     3-11
using ?     4-15

compliance
specifications     B-1

components
Cisco 7100 series     1-4
network processor card     1-40

config-register command     4-37

configure command     4-12

configure memory command     4-37

configure terminal command     4-37

configuring
ATM port     4-23
AutoInstall     4-5
checking settings     4-26
configure command     4-12
E1 ports     4-16
E3 ports     4-21
Fast Ethernet port     4-14
reviewing changes     4-26
router     4-4
sample file     4-11
saving settings     4-12
saving to NVRAM     4-26
setup facility     4-6
software     4-1
T1 ports     4-16
T3 ports     4-19
viewing settings     4-30

confreg command     4-35

console port     1-4, 1-41
cables     C-2
connecting     3-21
considerations     2-18
pinouts     C-2
settings     2-18, 3-21
specifications     B-1

console terminal
system banner display     5-6

cooling subsystem
troubleshooting     5-8

cooling subsystems
description     5-4

copy running-config command     4-26

copy running-config startup-config command     4-38

CPU reset button
caution     1-43
location     1-44

critical conditions
monitoring     1-46

crossover cables
identifying     C-5

ctrl-z command     4-15

D


data bits
console port     3-21

data terminal equipment
See DTE

defaults
AT3 ports     4-24
E1 ports     4-16
E3 ports     4-21
Fast Ethernet     4-14
T1 ports     4-16
T3 ports     4-19

dimensions
chassis     B-1

distance limitations
fiber-optic cable     C-31
transmission     2-15

double pole/neutral fusing
warning     3-24

downloading software     1-3

DSU
feature compatibilities     C-26

dsu bandwidth command     4-20, 4-22

DTE
auxiliary ports     2-19

E


E1 ports
configuring     4-16
defaults     4-16

E3 ports
cables     C-25
configuring     4-21
connecting     3-13
connecting requirements     3-13, C-25
defaults     4-21
DSU compatibilities     C-26

EEPROM
MAC address bank     1-37

EIA/TIA-232 cables
Cisco 7120-4T1     C-8
overview     C-10

EIA/TIA-449 cables
Cisco 7120-4T1     C-8
overview     C-13

EIA/TIA-612
serial cable conforms to     C-25

EIA/TIA-613
serial cable conforms to     C-25

EIA-530 cables
Cisco 7120-4T1     C-8
overview     C-23

electrical equipment guidelines     2-4

electromagnetic compliance
See EMC

electromagnetic pulse
See EMP

electrostatic discharge
See ESD

EMC
specifications     B-2

EMP
avoiding     2-15

enable command     4-13, 4-36

enable password command     4-37

enable secret command     4-37

enabled LEDs
Cisco 7120-4T1     1-9
Cisco 7120-AE3     1-17
Cisco 7120-AT3     1-17
Cisco 7120-E3     1-13
Cisco 7120-SMI3     1-17
Cisco 7120-T3     1-11
Cisco 7140-2AE3     1-25
Cisco 7140-2AT3     1-25
Cisco 7140-2E3     1-21
Cisco 7140-2MM3     1-25
Cisco 7140-2T3     1-19
function     5-5
ISM     1-31
troubleshooting     5-8

encapsulation
Cisco 7120-4T1     1-8

encryption
feature description     1-3

end command     4-15

environmental monitoring
description     1-45
feature     1-3
logs     1-41
power thresholds     1-46
sensors     1-41

environmental specifications     2-12

equipment racks
See racks

ESD
location     1-6
preventing     2-6
wrist straps     2-7

Ethernet connections     2-16

export laws
ISM     1-31

external timing signals     1-8

F


fans
description     1-6
failures     1-50
troubleshooting     5-8

Far End Receive Failure LEDs
See FERF LEDs

Fast Ethernet ports
cables     C-5
configuring     4-14
connecting     3-9
defaults     4-14
pinouts     C-5

features
Cisco 7120-4T1     1-8
Cisco 7120-AE3     1-14
Cisco 7120-AT3     1-14
Cisco 7120-E3     1-12
Cisco 7120-SMI3     1-14
Cisco 7120-T3     1-10
Cisco 7140-2AE3     1-22
Cisco 7140-2AT3     1-22
Cisco 7140-2E3     1-20
Cisco 7140-2MM3     1-22
Cisco 7140-2T3     1-18
description     1-3
network processor     1-39

FERF LEDs
description     1-12, 1-14, 1-20, 1-22
See also model names, such as Cisco 7120-4T1

ferrite beads     3-13, C-25

fiber-optic cables
distance limitations     C-31
power budget     C-31
specifications     C-30

field-replaceable units
See FRUs

fire risk warning     2-6

fixed LAN
LEDs     1-44
ports     1-4, 1-42
show interface command     1-35, 4-29
show interfaces command     1-35
slot numbering     1-33

fixed WAN
ports     1-4
show interface command     1-35, 4-29
show interfaces command     1-35
slot numbering     1-33

Flash Disks
description     1-27
memory options     1-29
reformatting (note)     1-28
replacing     1-28

Flash memory cards
description     1-27

Flash memory SIMMs
boot image     1-41
replacing     1-26

flow control
auxiliary port     3-23

footprints
chassis     2-10

FRUs
description     1-26

functional description
environmental monitoring     1-45
MAC address     1-37
network processor     1-39
OIR     1-3, 1-37
overview     1-33
PCI bus     1-38
slot numbering     1-33
system LEDs and reset button     1-43

G


gravity
maintaining low center     2-11

ground conductor warning     2-13

ground connections
installing     3-5
warning     2-5

ground receptacles
location     1-6

grounded equipment warning     2-5

grounding lugs     2-1
description     3-5

guidelines
electrical equipment     2-4
safety     2-3

H


half-duplex command     4-15

hardware address     1-36

hardware flow control
auxiliary port     3-23

heat dissipation
specifications     B-1

humidity
requirements     2-12
specifications     B-1

I


identifying startup problems     5-4

incorrect connection warning     2-17

installing
chassis grounding     3-5
preparing for     2-11
reading instructions     2-1
site requirements     2-8
tools for     2-1

Integrated Service Module
See ISM

interface atm command     4-25

interface fastethernet command     4-15

interface serial command     4-17, 4-19, 4-22

interface slot numbering
description     1-33

interface types
Cisco 7120-4T1     1-8
show interface command     1-35, 4-29
show interfaces command     1-35

interference
radio frequency     2-14

internal fans     1-6

internal timing signals     1-8

ip address command     4-15, 4-17, 4-20, 4-22, 4-25

IP Security Protocol
See IPSec

IPSec
description     1-1, 1-30

ISM
airflow caution     1-32
description     1-30
export laws     1-31
features     1-3, 1-4
installing     1-32
slot location     1-33

J


jewelry
avoiding for safety     2-3
removal warning     2-4

L


L2F/L2TP
description     1-1

LAN interfaces
fixed ports     1-4
LEDs     1-4
show interface command     1-35, 4-29
slot numbering     1-33
specification     B-1

laser
product warning     2-17, 3-19
radiation warning     2-17, 3-19
safety guidelines     2-17

Layer 2 Forwarding and Layer 2 Tunneling Protocol
See L2F/L2TP

LB LEDs
description     1-10

LEDs
at startup     5-5
boot process     4-2
Cisco 7120-4T1     1-9
Cisco 7120-AE3     1-17
Cisco 7120-AT3     1-17
Cisco 7120-E3     1-13
Cisco 7120-SMI3     1-17
Cisco 7140-2AE3     1-25
Cisco 7140-2AT3     1-25
Cisco 7140-2E3     1-21
Cisco 7140-2MM3     1-25
Cisco 7140-2T3     1-19
enabled     5-5, 5-8
ISM     1-31
PC Card slot     5-6
power     5-6
safety guidelines     2-17
system LEDs     1-4, 1-43

lifting
safety guidelines     2-7

lightning
safety guidelines     2-6
warning     3-9

line con 0 command     4-37

link LEDs
See LNK LEDs

link loss factors     C-33

lithium batteries     1-41

LL LEDs
description     1-12, 1-14, 1-20, 1-22
See also models, such as Cisco 7120-4T1

LNK LEDs
description     1-44

local loopback LEDs
See LL LEDs

logging in without a password     4-34

loopback command     3-15

loopback LEDs
See LB LEDs

loopbacks
Cisco 7120-4T1     1-8

lugs
grounding parts needed     2-1, 3-5

M


MAC addresses     1-36

media-type command     4-15

messages
fan failure     2-8

microprocessors
RISC     1-40

MM3 ports
cables     C-29
receptacles     C-29

MM3/SMI3 ports
power margin     C-32
signal requirements     C-33

modal dispersion     C-32

models
Cisco 7120 series     1-7
Cisco 7140 series     1-18
See also model names, such as Cisco 7120-4T1

modifying configurations
reviewing     4-26

modular port adapter
show interface command     4-29

modular port adapters
show interface command     1-35
show interfaces command     1-35
slot numbering     1-33

multimode connections
cabling     C-29
description     3-19
power budget (example)     C-34

N


network connections
description     3-9
Ethernet     2-16
WAN     2-17

network management
description     1-3

network processors
component descriptions     1-40
description     1-4
environmental monitoring and reporting     1-45
features     1-39
field-replaceable units     1-29
location of devices     1-40
troubleshooting     5-7

no shutdown command     3-11, 4-16, 4-18, 4-20, 4-23, 4-26, 4-37

nonoperating specifications     2-12

normal conditions
monitoring     1-46

notes
AC power cable strain relief     3-26
AC power supply voltage requirements     1-6
Break function     4-34
chassis ground connection     2-12, 2-14
compliance     3-16
correcting EMI     2-15
logging in without a password     4-34
power requirements     2-14
recovering passwords     4-34
temperature ranges     1-49
transmission rates and distance limits     2-15

numbering
slots     1-33

NVRAM
description     1-41
saving configuration     4-12, 4-26

O


OC-3 ATM cables
obtaining     C-29
using     C-29

OC-3c/STM-1 connections
description     3-19

OIR
description     1-3, 1-37

online insertion and removal
See OIR

OOF LEDs
description     1-12, 1-14, 1-20, 1-22
See also model names, such as Cisco 7120-4T1

operating specifications     2-12

Out of Frame LEDs
See OOF LEDs

overheating
at startup     5-4
caution     1-47, 2-11
preventing     2-8

P


packet memory
description     1-29, 1-41
size     1-4

parity
console port     3-21

password command     4-37

passwords
changing caution     4-36, 4-38
recovering lost     4-34

PC Card slots
Flash Disk     1-27
Flash memory     1-27
LEDs     1-44
location     1-4
memory types     1-42

PCI bus
description     1-6, 1-38, 1-40

peripheral component interconnect bus
See PCI bus

pinouts
auxiliary port     C-4
Cisco 7120-4T1     C-6
console port     C-2
Fast Ethernet port     C-5

placement guidelines
tabletop     3-1

plant wiring
guidelines     2-14

plug-socket combination
warning     3-25

port adapters
bandwidth points     A-1
installing blank     2-9
installing blank (caution)     1-27
overview     1-26
replacing     1-26
show interface command     1-35, 4-29
show interfaces command     1-35
slot location     1-33
slot numbering     1-33
troubleshooting     5-5, 5-8

port numbers
description     1-33

ports
auxiliary     1-4, 1-41
console     1-4, 1-41
LAN     1-4
WAN     1-4

power
site requirements     2-14
subsystem for troubleshooting     5-6
surge suppression     2-15
ungrounded     2-5

power budget
calculating     C-33
fiber-optics cable     C-31
multimode example     C-34
single-mode example     C-35

power connections
guidelines     2-13
warning     2-4

power cords
troubleshooting     5-6
unplugging for safety     2-4

power factor corrector     2-14

power LEDs     1-4
See PWR LEDs

power margins
calculating     C-33

power supply     5-5
cables     B-1
connecting     3-24
description     1-6
feature     1-4
LEDs     5-5
power factor corrector     2-14
specifications     B-1
troubleshooting     5-4
voltage and temperature     1-45
warning     2-4, 3-24

power thresholds     1-47

powering up
guidelines     3-24

procedures
ATM E3 WAN port, connecting     3-17
ATM OC-3c/STM-1 WAN port, connecting     3-19
ATM T3 WAN port, connecting     3-17
auxiliary port, connecting     3-23
brackets, attaching     3-3
chassis, grounding     3-5
console port, connecting     3-21
E3 WAN port, connecting     3-14
LAN port, connecting     3-10
power, connecting     3-25
rack-mounting     3-3  to 3-4
T3 WAN port, connecting     3-11, 3-14
viewing system configuration     4-30

processor subsystem
description     5-4

product description     1-1

product disposal
warning     2-4

PWR LEDs     5-5, 5-6
description     1-44

Q


QoS
description     1-1

quality of service
See QoS

R


rack-mount brackets     2-1

rack-mount kits
field-replaceable unit     1-32
overview     1-7
replacement instructions     1-26

rack-mounting
attaching brackets     3-3
back panel forward     3-4
brackets, standard     3-3
front panel forward     3-4

racks
mounting guidelines     2-9

radiation
laser warning     2-17, 3-19

RC LEDs
description     1-10

RCLK LEDs
description     1-12, 1-14, 1-20, 1-22
See also model names, such as Cisco 7120-4T1

RD LEDs
description     1-9

receive alarm LEDs
See RX ALM LEDs

receive ATM cell LEDs
See RX CEL LEDs

receive carrier LEDs
See RX CAR LEDs

receive cell LEDs
See RX CEL LEDs

receive clock LED
See RCLK LEDs

receive clock LEDs
See RC LEDs
See RCLK LEDs

receive data LEDs
See RD LEDs

receptacles
AE3 ports     C-27
AT3 ports     C-27
MM3 port     C-29
MM3 ports     C-29
SMI3 ports     C-29

reload command     4-38

remote loopback LEDs
See RL LEDs

replacing
Flash Disk     1-28
ISM service module     1-32
port adapters     1-26
rack-mount kit     1-26
SDRAM memory     1-26

reset buttons     1-43
caution     1-43
location     1-44

reset command     4-35

restricted access area
warning     2-8

reviewing changes to configuration     4-26

RFC 1406     1-8

RISC microprocessors     1-40

RJ-45-to-DB-25 DCE adapters     3-21, C-1

RJ-45-to-DB-25 DTE adapters     3-21, C-1

RJ-45-to-DB-9 DTE adapters     3-21, C-1

RJ-45-to-RJ-45 rollover cables     3-21, C-1

RL LEDs
description     1-12, 1-14, 1-20, 1-22
See also model names, such as Cisco 7120-4T1

rollover cables
identifying     C-2

rubber feet
attaching     3-2

RX ALM LEDs     1-25
description     1-17

RX CAR LEDs     1-25
description     1-17

RX CEL LEDs     1-25
description     1-17

S


safety
warnings translated     xiv

safety cover
warning     2-3

safety guidelines
ESD prevention     2-6
general     2-3
laser and LED     2-17
plant wiring     2-14
power connections     2-13

safety specifications     B-2

sample configuration     4-11

saving configuration settings     4-26

SDRAM memory
description     1-4, 1-29
options     1-30
packet memory     1-41
replacing     1-26
system memory
description     1-41

sensors
environmental monitoring     1-41

serial interface cables
caution     3-12, C-7

service modules
slot location     1-3, 1-33
using blank     1-32

service personnel warning     2-17

settings
console port     2-18

setup command     4-3

setup facility     4-6

shipping containers
contents     2-2

show diag command     4-31

show environment command     1-47, 2-8, 5-9

show environment table     5-9

show interface command     1-35, 4-29

show interfaces command     1-35

show running-config command     4-26

show startup-config command     4-26, 4-34, 4-36

show version command     1-43, 4-5, 4-30

shutdown
preventing administrative     4-37

shutdown command     3-11

Simple Network Management Protocol
See SNMP

single-mode connections     C-29

single-mode intermediate reach
connecting     3-19

single-mode power budget example     C-35

site requirements
environment     2-12
equipment racks     2-9
guidelines     2-8
plant wiring     2-14
power     2-14

slot 0
fixed LAN interface     1-33

slot 1 and 2
fixed WAN interface     1-33

slot 3 and 4
modular port adapter slot     1-33

slot 5
service module     1-33

slot LEDs     1-4, 1-44, 5-6

slot numbering
Cisco 7140 series (figure)     1-34
description     1-33
figure     1-34
fixed LAN ports     1-4
fixed WAN ports     1-4
PC Card     1-4
service module     1-4

SMI3 ports
cables     C-29
receptacles     C-29

SNMP
description     1-3

software configuration     4-4
basic startup     4-1  to 4-26

software image
boot ROM     1-41
Flash Disk and Flash memory     1-27
show version command     1-43

software recommended     B-1

SONET
connections     C-29
distance limitations     C-31
power budget     C-31
power budget (example)     C-34, C-35
signal requirements     C-33

specifications
airflow     B-1
auxiliary port     B-1
compliance     B-1
console port     B-1
dimensions     B-1
EMC     B-2
environmental     2-12
heat dissipation     B-1
humidity     B-1
LAN interfaces     B-1
minimum software recommended     B-1
physical     B-1
power     B-1
power supply     B-1
safety     B-2
temperature     B-1
WAN ports     B-1

startup
troubleshooting     5-4

status
environmental     2-8

status LEDs
Cisco 7120-4T1     1-9
Cisco 7120-AE3     1-17
Cisco 7120-AT3     1-17
Cisco 7120-E3     1-13
Cisco 7120-SMI3     1-17
Cisco 7120-T3     1-11
Cisco 7140-2AE3     1-25
Cisco 7140-2AT3     1-25
Cisco 7140-2E3     1-21
Cisco 7140-2MM3     1-25
Cisco 7140-2T3     1-19
ISM     1-31

stop bits
console port     3-21

straight-through cables
identifying     C-5

subsystems for troubleshooting
cooling     5-4, 5-8
power     5-4, 5-6
processor     5-4

SYS RDY LEDs
description     1-44
troubleshooting     5-5, 5-7

system
configuration in NVRAM     1-41
LED locations     1-44

system controllers
processor card     1-40

system memory
description     1-4, 1-29, 1-41

system ready LEDs
See SYS RDY LEDs

system startup
before startup     4-2

T


T1 ports
configuring     4-16
connecting     3-11
defaults     4-16

T3 ports
cables     C-25
configuring     4-19
connecting     3-13
defaults     4-19
DSU compatibilities     C-26

tabletop mounting     1-7, 3-1

TC LEDs
description     1-9

TD LEDs
description     1-9

telco-type equipment racks
rack-mounting guidelines     2-9

telephone jacks
installing precautions     2-6

telephone network cables
warning     3-9

temperature
requirements for operation     2-12
specifications     B-1

temperature thresholds     1-46

terms and acronyms     xvi

thresholds
power     1-47
temperature     1-46

timing signals     1-8

tools
for attaching ground connections     3-5
for installing     2-1

trained personnel
warning     2-1

translated safety warnings     xiv

transmission speeds
configuring auxiliary port     3-23

transmit clock LEDs
See TC LEDs

transmit data LEDs
See TD LEDs

troubleshooting
cooling subsystem     5-8
cooling subsystems     5-4
LED descriptions
Cisco 7120-4T1     1-9
Cisco 7120-AE3     1-17
Cisco 7120-AT3     1-17
Cisco 7120-E3     1-14
Cisco 7120-SMI3     1-17
Cisco 7120-T3     1-12
Cisco 7140-2AE3     1-25
Cisco 7140-2AT3     1-25
Cisco 7140-2E3     1-22
Cisco 7140-2MM3     1-25
Cisco 7140-2T3     1-20
fixed LAN ports     1-44
ISM     1-31
PC Card slots     1-44
system     1-44
network processor     5-7
overview     5-2
port adapters     5-8
ports     5-5
power subsystem     5-6
power supply     5-4, 5-6
processor     5-4
startup problems     5-4
strategy     5-3

V


V.35 cables
Cisco 7120-4T1     C-8
overview     C-17

Virtual Private Networks
See VPNs

VPNs
description     1-1
network example     1-2

W


WAN interfaces
show interface command     1-35, 4-29
slot numbering     1-33

WAN ports
connecting     2-17
connecting (warning)     2-17, 3-9
fixed interface     1-4
LEDs     1-4
specifications     B-1

warning conditions
monitoring     1-46

warnings
AC circuit breaker     2-5, 2-13
chassis lifting     2-7
double pole/neutral fusing     3-24
fire risk     2-6
ground conductor     2-13
ground connection first     2-5
grounded equipment     2-5
incorrect connection     2-17
installation instructions     2-1
jewelry     2-3, 2-4
laser products     2-17, 3-19
laser radiation     2-17, 3-19
ligtning activity     3-9
plug-socket combination     3-25
power connections     2-4
power supply     2-4, 3-24
product disposal     2-4
read installation instructions     3-1
restricted access area     2-8
safety cover     2-3
service personnel     2-17
telephone-network cables     3-9
trained personnel     2-1
WAN connections     2-17, 3-9

weight
chassis     B-1

wiring
interference     2-14
plant     2-14
telephone     2-6

wrist straps
attaching     2-7

X


X.21 cable
overview     C-20

X.21 cables
Cisco 7120-4T1     C-8

hometocprevnextglossaryfeedbacksearchhelp
Posted: Tue Jul 27 17:21:56 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.