This appendix provides information on the Cisco uBR7200 series universal broadband router physical specifications and compliance with U.S. export laws and regulations for encryption.
Table A-1 lists the Cisco uBR7223 physical specifications and power requirements.
| Description | Specification |
|---|---|
Midplane | Two primary PCI buses and one secondary PCI bus with an aggregate bandwidth of 600 Mbps |
Dimensions (H x W x D) | 6.70 x 17.38 x 21.25 in. (17.02 x 44.15 x 53.98 cm) |
Weight | Chassis fully configured with a network processing engine, I/O controller, 1 port adapter, 2 cable modem cards, 1 power supply, and a fan tray: ~ 75 lb (34.0 kg) |
Heat dissipation | 700W (2388 Btu1), 300W typical |
AC-input power | 700W maximum, 300W typical |
Maximum AC-input voltage | 100 to 240 VAC2 wide input with power factor correction |
AC-input current rating | 7A3 with the chassis fully configured |
AC-input cable | 18 AWG4 three-wire cable, with a three-lead IEC-320 receptacle on the power supply end, and a country-dependent plug on the power source end |
DC-input voltage rating | -48 VDC5 nominal in North America |
DC-input current rating | 14A maximum (7.7A typical draw at -48 VDC, 6.2A typical draw at -60 VDC) |
DC-input cable | 12 AWG (3.91 mm2) recommended minimum, with at least three conductors rated for at least 140 degrees Fahrenheit (60 degrees Celsius) |
DC-output power | 550W maximum (with a single power supply configuration) |
DC voltages supplied | +3.5V, +5.2V, +12.2V, -12.2V, +16V, -16V |
Frequency | 50/60 Hz |
Airflow | ~80 cfm6 |
Temperature | 32 to 104 degrees Fahrenheit (0 to 40 degrees Celsius) operating; -4 to 149 degrees Fahrenheit (-20 to 65 degrees Celsius) nonoperating |
Humidity | 10 to 90% noncondensing |
Software requirement | Cisco IOS Release 11.3(9)NA1 or later version of Cisco IOS Release 11.3 NA |
Agency approvals | Safety: UL 1950, CSA 22.2 No. 950, EN60950 |
| 1Btu = British thermal units. 2VAC = volts alternating current. 3A = ampere. 4AWG = American Wire Gauge. 5VDC = volts direct current. 6cfm = cubic feet per minute. |
Table A-2 lists the Cisco uBR7246 physical specifications and power requirements.
| Description | Specification |
|---|---|
Midplane | Two primary PCI buses and one secondary PCI bus with an aggregate bandwidth of 600 Mbps |
Dimensions (H x W x D) | 10.5 x 17.00 x 21.25 in. (26.67 x 43.18 x 53.98 cm) |
Weight | Chassis fully configured with a network processing engine, I/O controller, 2 port adapters, 4 cable modem cards, 2 power supplies, and a fan tray: ~ 100 lb (45.4 kg) |
Heat dissipation | 800W (2730 Btu1) |
AC-input power | 800W maximum (with either a single or dual power supply configuration) |
Maximum AC-input voltage | 100 to 240 VAC2 wide input with power factor correction |
AC-input current rating | 7A3 maximum at 110 VAC and 3.5A maximum at 240 VAC with the chassis fully configured |
AC-input cable | 18 AWG4 three-wire cable, with a three-lead IEC-320 receptacle on the power supply end, and a country-dependent plug on the power source end |
DC-input voltage rating | -48 VDC5 nominal in North America |
DC-input current rating | Not to exceed 13A maximum at -48 VDC (370W/-48 VDC = 7.7A typical draw) |
DC-input cable | 12 AWG (3.91 mm2) recommended minimum, with at least three conductors rated for at least 140 degrees Fahrenheit (60 degrees Celsius) |
DC-output power | 550W maximum (with either a single or dual power supply configuration) |
DC voltages supplied | +3.5V, +5.2V, +12.2V, -12.2V, +16V, -16V |
Frequency | 50/60 Hz |
Airflow | ~120 cfm6 |
Temperature | 32 to 104 degrees Fahrenheit (0 to 40 degrees Celsius) operating; -4 to 149 degrees Fahrenheit (-20 to 65 degrees Celsius) nonoperating |
Humidity | 10 to 90% noncondensing |
Software requirement | Cisco IOS Release 11.3(9)NA1 or later version of Cisco IOS Release 11.3 NA |
Agency approvals | Safety: UL 1950, CSA 22.2 No. 950, EN60950 |
| 1Btu = British thermal units. 2VAC = volts alternating current. 3A = ampere. 4AWG = American Wire Gauge. 5VDC = volts direct current. 6cfm = cubic feet per minute. |
Table A-3 lists the Cisco uBR7246 VXR physical specifications and power requirements.
| Description | Specification |
|---|---|
Midplane | Two primary PCI buses and one secondary PCI bus with an aggregate bandwidth of 600 Mbps |
Dimensions (H x W x D) | 10.5 x 17.00 x 21.25 in. (26.67 x 43.18 x 53.98 cm) |
Weight | Chassis fully configured with a network processing engine, I/O controller, 2 port adapters, 4 cable modem cards, a clock card, 2 power supplies, and a fan tray: ~ 100 lb (45.4 kg) |
Heat dissipation | 800W (2730 Btu1) |
AC-input power | 800W maximum (with either a single or dual power supply configuration) |
Maximum AC-input voltage | 100 to 240 VAC2 wide input with power factor correction |
AC-input current rating | 7A3 maximum at 110 VAC and 3.5A maximum at 240 VAC with the chassis fully configured |
AC-input cable | 18 AWG4 three-wire cable, with a three-lead IEC-320 receptacle on the power supply end, and a country-dependent plug on the power source end |
DC-input voltage rating | -48 VDC5 nominal in North America |
DC-input current rating | Not to exceed 13A maximum at -48 VDC (370W/-48 VDC = 7.7A typical draw) |
DC-input cable | 14 AWG (2.08 mm2) recommended minimum, with at least three conductors rated for at least 140 degrees Fahrenheit (60 degrees Celsius) |
DC-output power | 550W maximum (with either a single or dual power supply configuration) |
DC voltages supplied | +3.5V, +5.2V, +12.2V, -12.2V, +16V, -16V |
Frequency | 50/60 Hz |
Airflow | ~120 cfm6 |
Temperature | 32 to 104 degrees Fahrenheit (0 to 40 degrees Celsius) operating; -4 to 149 degrees Fahrenheit (-20 to 65 degrees Celsius) nonoperating |
Humidity | 10 to 90% noncondensing |
Software requirement | Cisco IOS Release 12.0(7)SC or later version of Cisco IOS Release 12.0 SC |
Agency approvals | Safety: UL 1950, CSA 22.2 No. 950, EN60950 |
| 1Btu = British thermal units. 2VAC = volts alternating current. 3A = ampere. 4AWG = American Wire Gauge. 5VDC = volts direct current. 6cfm = cubic feet per minute. |
![]() |
Note For a chassis footprint, additional dimensions, and clearance requirements for the Cisco uBR7200 series perimeter, refer to the "Site Requirements" section. |
Cisco cable modem cards perform encryption and are regulated for export by the U.S. Government. Following is specific information regarding compliance with U.S. export laws and regulations for encryption products:
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Tue Mar 28 08:53:53 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.