Cisco uBR7246 and the 12E/2FE  Port  Adapter

Cisco uBR7246 and the 12E/2FE  Port  Adapter

This chapter provides information on the 12E/2FE port adapter and its use on the Cisco  uBR7246 universal broadband router. This chapter includes the following sections:

Installation Overview

The dual-width 12E/2FE port adapter can be installed in the horizontally aligned pair of port adapter slots in Cisco  uBR7246. Figure 4-1 shows a 12E/2FE port adapter installed in port adapter slot  1 and slot  2 of a Cisco  uBR7246.


Figure 4-1: Cisco  uBR7246 with a 12E/2FE Port Adapter in Port Adapter Slot  1 and Slot  2


Depending on the circumstances, you might need to install a new port adapter or replace a failed port adapter in a Cisco  uBR7246. In either case no tools are necessary; all port adapters available for the Cisco  uBR7246 connect directly to the router midplane and are locked into position by a port adapter retention clip.


Note The dual-width 12E/2FE port adapter occupies the two horizontally aligned port adapter slots and is locked into position by the port adapter retention clip at the center of the port adapter.

When removing and replacing a port adapter, you will need an antistatic mat onto which you can place a removed port adapter and an antistatic container into which you can place a failed port adapter for shipment back to the factory.


Note The Cisco  uBR7246 supports OIR; therefore, you do not have to power down the router when removing and replacing a 12E/2FE port adapter.

When a port adapter slot is not in use, blank port adapters must fill empty slots to allow the router to conform to EMI emissions requirements and to allow proper air flow across the port adapters. If you plan to install a new port adapter in a slot that is not in use, you must first remove the blank port adapter.


Note If you are installing a dual-width port adapter in two port adapter slots that are occupied by single-width port adapters, you must remove the single-width port adapters and the port adapter slot divider before installing the dual-width port adapter.

Removing a Single-Width Port Adapter

Following is the procedure for removing a single-width port adapter from a Cisco  uBR7246:


Note Single-width port adapters occupy individual port adapter slots in a Cisco  uBR7246.

Step 1 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.

Step 2 Slide the port adapter retention clip down to the unlocked position. The retention clip remains in the unlocked position. (See Figure 4-2.)


Figure 4-2: Placing the Port Adapter Retention Clip in the Unlocked Position


Step 3 Grasp the handle on the port adapter and pull the port adapter from the midplane, about halfway out of its slot. If you are removing a blank port adapter, pull the blank port adapter from the chassis slot.

Step 4 With the port adapter halfway out of the slot, disconnect all cables from the port adapter.

Step 5 After disconnecting the cables, pull the port adapter from its chassis slot.

Caution Always handle the port adapter by the carrier edges and handle; never touch the port adapter's components or connector pins. (See Figure 4-3.)

Figure 4-3:
Handling a Port Adapter


Step 6 Place the port adapter on an antistatic surface with its components facing upward, or in a static shielding bag. If the port adapter will be returned to the factory, immediately place it in a static shielding bag.

This completes the procedure for removing a single-width port adapter from a Cisco  uBR7246.

Removing a Port Adapter Slot Divider

Following is the procedure for removing a port adapter slot divider from a Cisco  uBR7246:

Step 1 Remove installed single-width port adapters from the slots on both sides of the port adapter slot divider. (See the "Removing a Single-Width Port Adapter" section for instructions.)

Step 2 With one hand, raise the slot divider lever to unlock the slot divider from the chassis. (See Figure 4-4.)


Figure 4-4: Slot Divider Lever


Step 3 With the slot divider lever still raised, use your other hand to pull the slot divider from the chassis. (See Figure 4-5.)


Figure 4-5: Removing the Slot Divider from the Chassis


Step 4 Store the slot divider in a location where you can retrieve it for use later.

This completes the procedure for removing a port adapter slot divider from a Cisco  uBR7246.

Installing a Dual-Width Port Adapter

Following is the procedure for installing a dual-width port adapter in a Cisco  uBR7246:

Step 1 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.

Step 2 If necessary, remove the port adapter slot divider that divides the two port adapter slots you are installing the dual-width port adapter into. (See the 6 for instructions.)

Step 3 Use both hands to grasp the port adapter by its metal carrier edges and position the port adapter so that its components are downward. (See Figure 4-3.)

Step 4 Align the left and right edge of the port adapter metal carrier between the guides in the port adapter slot. (See Figure 4-6.)


Figure 4-6: Aligning the Port Adapter Metal Carrier Between the Slot Guides


Step 5 With the metal carrier aligned in the slot guides, gently slide the port adapter halfway into the slot.

Caution Do not slide the port adapter all the way into the slot until you have connected all required cables. Trying to do so will disrupt normal operation of the router.

Step 6 With the port adapter halfway in the slot, connect all required cables to the port adapter.

Step 7 After connecting the cables, carefully slide the port adapter all the way into the slot until the port adapter is seated in the midplane.

Step 8 Slide the port adapter retention clip up to the locked position. (See Figure 4-7.)


Figure 4-7: Placing the Port Adapter Retention Clip in the Locked Position


This completes the procedure for installing a dual-width port adapter in a Cisco  uBR7246.

Removing a Dual-Width Port Adapter

Following is the procedure for removing a dual-width port adapter from a Cisco  uBR7246:

Step 1 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.

Step 2 Slide the port adapter retention clip down to the unlocked position. The retention clip remains in the unlocked position. (See Figure 4-8.)


Figure 4-8: Placing the Port Adapter Retention Clip in the Unlocked Position


Step 3 Grasp the two handles on the dual-width port adapter and pull the port adapter from the midplane, about halfway out of its slot.

Step 4 With the port adapter halfway out of the slot, disconnect all cables from the port adapter.

Step 5 After disconnecting the cables, pull the port adapter from its chassis slot.

Caution Always handle the port adapter by the carrier edges and handles; never touch the port adapter's components or connector pins. (See Figure 4-3.)

Step 6 Place the port adapter on an antistatic surface with its components facing upward, or in a static shielding bag. If the port adapter will be returned to the factory, immediately place it in a static shielding bag.

This completes the procedure for removing a dual-width port adapter from a Cisco  uBR7246.

Installing a Port Adapter Slot Divider and a Single-Width Port Adapter

Following is the procedure for installing a port adapter slot divider in a Cisco  uBR7246:

Step 1 Position the slot divider so that the slot divider lever faces you and is at the bottom.

Step 2 Align the left and right edge of the slot divider between the guides in the port adapter slot. (See Figure 4-9.)


Figure 4-9: Aligning the Slot Divider Between the Slot Guide


Step 3 With the left and right edge of the slot divider aligned in the slot guides, slide the slot divider all the way into the slot until you feel the slot divider lock into place (listen for a click).

This completes the procedure for installing a port adapter slot divider in a Cisco  uBR7246.

Installing a Single-Width Port Adapter

Following is the procedure for installing a single-width port adapter in a Cisco  uBR7246:

Step 1 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.

Step 2 Use both hands to grasp the port adapter by its metal carrier edges and position the port adapter so that its components are downward. (See Figure 4-3.)

Step 3 Align the left and right edge of the port adapter metal carrier between the guides in the port adapter slot. (See Figure 4-10.)


Figure 4-10: Aligning the Port Adapter Metal Carrier Between the Slot Guides


Step 4 With the metal carrier aligned in the slot guides, gently slide the port adapter halfway into the slot.

Caution Do not slide the port adapter all the way into the slot until you have connected all required cables. Trying to do so will disrupt normal operation of the router.

Step 5 With the port adapter halfway in the slot, connect all required cables to the port adapter.

Step 6 After connecting the cables, carefully slide the port adapter all the way into the slot until the port adapter is seated in the midplane.

Step 7 Slide the port adapter retention clip up to the locked position. (See Figure 4-11.)


Figure 4-11: Placing the Port Adapter Retention Clip in the Locked Position


This completes the procedure for installing a port adapter in a Cisco  uBR7246. Proceed to
"Installing the 12E/2FE Interface Cables," to connect the necessary cables to your port  adapter.


hometocprevnextglossaryfeedbacksearchhelp