This chapter provides a list of parts and tools you need to perform the port adapter installation, software and hardware requirements, and safety and ESD-prevention guidelines to help you avoid injury and damage to the equipment during installation.
The following sections present general information and information about port adapter installation requirements:
A Telecommunications Authority of Singapore (TAS) label is shipped with each PA-A2-4E1XC-E3ATM port adapter and signifies that each port adapter meets Singapore's requirements as specified for connecting to the public network.
Attach the TAS label to the rear of the host Cisco 7200 series or Cisco uBR7200 series chassis next to the other agency approvals for the chassis. (See Figure 1.)

You need the following parts and tools to install an ATM CES port adapter. If you need additional equipment, ask your service representative for ordering information.
Table 2-1 lists the minimum Cisco IOS software release required to use the ATM CES port adapter in supported router platforms.
| Router Platform | Recommended Minimum Cisco IOS Release |
|---|---|
| Cisco 7200 series |
|
| Cisco IOS Release 12.0(2)XE2 or a later release of Cisco IOS Release 12.0 XE |
| Cisco IOS Release 11.1(14)CA or a later release of Cisco IOS Release 11.1 CC |
| Cisco IOS Release 11.1(14)CA or a later release of Cisco IOS Release 11.1 CC |
| Cisco uBR7200 series |
|
Cisco uBR7246 | Cisco IOS Release 12.0(3)T or a later release of Cisco IOS Release 12.0 T |
To determine if your Cisco 7200 series router or Cisco uBR7246 is compatible with the ATM CES port adapter, use the show version command to display the current hardware configuration of the router, including the system software version that is currently loaded and running. You can check the version of the default ROM image by removing the board and checking the ROM labels, or by configuring the interface or system software to boot from ROM, restarting the system, and using these same commands to check the running version.
Use the show version command to display the current system software version. In the following example, the running system software is Cisco IOS Release 11.1(14)CA on a Cisco 7200 series router.
Router> show version Cisco Internetwork Operating System Software IOS (tm) 7200 Software (C7200-J-M), Version 11.1(14)CA Synced to mainline version: 11.1(9) Copyright (c) 1986-1997 by cisco Systems, Inc. Compiled Tue 18-Feb-97 19:12
If your system lacks the required system software and microcode, contact a customer service representative for upgrade information. For more information, see the "Cisco Connection Online" section.
Following are safety guidelines that you should follow when working with any equipment that connects to electrical power or telephone wiring.
![]() | Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device. |
Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen, kunt u het document Regulatory Compliance and Safety Information (Informatie over naleving van veiligheids- en andere voorschriften) raadplegen dat bij dit toestel is ingesloten.
Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta).
Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d'avertissements figurant dans cette publication, consultez le document Regulatory Compliance and Safety Information (Conformité aux règlements et consignes de sécurité) qui accompagne cet appareil.
Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Dokument Regulatory Compliance and Safety Information (Informationen zu behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät geliefert wurde.
Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nel documento Regulatory Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) che accompagna questo dispositivo.
Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i dokumentet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) som ble levert med denne enheten.
Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte o documento Regulatory Compliance and Safety Information (Informação de Segurança e Disposições Reguladoras) que acompanha este dispositivo.
¡Advertencia! Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo.
Varning! Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information (Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning.
The single-mode transmitter in the ATM CES port adapter uses a small laser to transmit the light signal to the network ring. Keep the transmit port covered whenever a cable is not connected to it.
Here is an example of the laser warning label that appears on the product:

![]() | Warning Invisible laser radiation may be emitted from the aperture ports of the single-mode ATM CES port adapter when no fiber cable is connected. Avoid exposure and do not stare into open apertures. |
![]() | Warning Class 1 laser product. |
Follow these basic guidelines when working with any electrical equipment:
Electrostatic discharge (ESD) damage, which can occur when electronic cards or components are improperly handled, results in complete or intermittent failures. Port adapters and processor modules consist of printed circuit boards that are fixed in metal carriers. Electromagnetic interference (EMI) shielding and connectors are integral components of the carrier. Although the metal carrier helps to protect the board from ESD, use a preventive antistatic strap during handling.
Following are guidelines for preventing ESD damage:
![]() | Caution For safety, periodically check the resistance value of the antistatic strap. The measurement should be between 1 and 10 megohm (Mohm). |
The ATM CES port adapter has 13 LEDs that indicate the status of the port adapter, the status of the uplink ports, and the status of the CBR ports. (See Figure 2-1 and Figure 2-2.)


Table 2-2 describes the LED that indicates port adapter status.
| Name | Color | State | Description |
|---|---|---|---|
Enabled | Green | On | Indicates that the port adapter is ready. |
After system initialization, the enabled LED goes on to indicate that the port adapter has been enabled for operation.
The following conditions must be met before the ATM CES port adapter is enabled:
If any of these conditions is not met, or if the initialization fails for other reasons, the enabled LED does not go on.
Table 2-3 describes the LEDs that indicate uplink port status.
| Name | Color | State | Description |
|---|---|---|---|
RCLK | Green | On | Indicates that a receive clock was detected. |
FERF | Yellow | On | Indicates that Framer detected Far End Receive Failure. |
OOF | Yellow | On | Indicates that Framer detected Out of Frame. |
AIS | Yellow | On | Indicates that Framer detected Alarm Indication Signal. |
Table 2-4 describes the LEDs that indicate CBR port status. There are four Enabled and four Alarm LEDs, one for each port.
.
| Enable LED State | Alarm LED State | Description |
|---|---|---|
Off | Off | Indicates that port is administratively down |
Off | On (yellow) | In loop mode |
On (green) | Off | Indicates that the port is enabled (normal state) |
On (green) | Blinking (yellow) | Integrating state, idle state, yellow or blue alarm |
On (green) | On (yellow) | Red alarm condition |
Cables on the ATM CES port adapter fall into two categories:
ATM CES port adapter interfaces are full-duplex. You must use the appropriate ATM interface cable and CBR cable to connect the ATM CES port adapter with an external ATM network. The ATM CES port adapters, shown in Figure 1-1 and Figure 1-2, provides an interface to ATM switching fabrics for transmitting and receiving data at rates of up to 155 Mbps bidirectionally for OC-3, 44.736 Mbps bidirectionally for DS3 over T3, and 34 Mbps bidirectionally for E3.
Cables can be obtained from the following cable vendors:
Two types of cables are available for use with the ATM CES port adapter's OC-3 and T3/E3 ATM ports:
Both ATM cables conform to the EIA/TIA-612 and EIA/TIA-613 specifications. The ATM port on the ATM CES port adapter is a DTE device.
For OC-3 single-mode, the ATM CES port adapter connects to the SONET/SDH 155-Mbps single-mode optical fiber physical layer, either STS-3C or STM-1. The connection is made by means of single-mode OC-3 ATM cables with SC connectors (see Figure 2-3). The SONET single-mode SC connector is shipped with removable dust covers on each SC connector. Keep covers on any connectors that are not being used.
For SONET/STC-3C single-mode connections, use one duplex SC connector (see Figure 2-3) or two single SC connectors (see Figure 2-4).


For T3/E3 connections, use a 75-ohm coaxial interface cable (see Figure 2-5). The T3/E3 75-ohm coaxial cable is available from Cisco in five different lengths: 10, 25, 50, 75, and 100 feet. They are not available from outside commercial vendors. The typical maximum distance between stations for T3 transmissions is 450 feet (135 meters) and for E3 transmissions is 1300 feet (390 meters).

The T3/E3 line interface performs physical layer translation from the ATM CES port adapter to the T3/E3 line interface in accordance with ATM Forum UNI specification Version 3.1, ACCUNET T45 service specifications, and ANSI T1E1.107.
The four CBR interface receptacles on the ATM CES port adapter are RJ-48C for T1 and E1 (120 ohm). Each connection supports T1 or E1 (120-ohm) interfaces that meet T1E1.403 and ACCUNET TR62411 standards. The RJ-48C connection does not require an external transceiver. The CBR ports are T1 interfaces that use UTP, 100-ohm twisted pair cables and E1 interfaces that use UTP, 120-ohm twisted pair cables (see Figure 2-6). The typical maximum distance between stations for T1 and E1 transmissions is 1000 feet (300 meters).

Table 2-5 lists the pinouts and signal descriptions for the CBR RJ-48C connector.
| Pin | Signal1 |
|---|---|
1 | Rx ring |
2 | Rx tip |
3 | NC |
4 | Tx ring |
5 | Tx tip |
6 | NC |
7 | NC |
8 | NC |
| 1Tx = transmit. Rx = receive. NC = no connect. |
The following sections provide compliance information that pertains to the ATM CES port adapter, which has been designed to meet these requirements. Modifications to this product that are not authorized by Cisco Systems, Inc., could void the various approvals, and negate your authority to operate the product.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures:
The BABT607114 marking on the ATM CES port adapter signifies that the port adapter's E3 ATM port meets United Kingdom directive 607114 and has been designed to BABT standards, which complies with the TBR24 specification. The BABT label is located on the top of the ATM CES port adapter; Figure 2-7 shows the BABT label for the E3 ATM port of the ATM CES port adapter.

The CE0168 marking on the ATM CES port adapter signifies that the port adapter's 120-ohm E1 ports meet United Kingdom directive 0168 and has been designed to CE standards, which complies with the CTR12 and TBR13 specifications. The CE label is located on the top of the ATM CES port adapter; Figure 2-8 shows the CE label for the 120-ohm E1 ports of the ATM CES port adapter.

Modifications to this product not authorized by Cisco Systems, Inc. could void the compliance approvals and negate your authority to operate the product.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed Apr 21 17:33:20 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.