Resolving Error Messages

Resolving Error Messages

This appendix lists and describes system error messages for the LightStream 1010 Asynchronous Transfer Mode (ATM) switch. The system software sends these error messages to the console (and, optionally, to a logging server on another system) during operation. Not all system error messages indicate problems with your system. Some are purely informational, while others may help diagnose problems with communications lines, internal hardware, or the system software.


Note An alphabetical listing of the error codes appears at the end of this chapter. The index of system error messages is alphabetized by facility-severity-mnemonic.

How This Guide Is Organized

The system error message main section provides descriptions of error messages organized according to the particular system facility that produces the messages. The facilities sections appear in alphabetical order, and within each system facility section, messages are listed alphabetically by mnemonic. Each error message is followed by an explanation and a recommended action. System error messages appear only when the system remains operational.

Error message severity levels correspond to the keywords assigned by the logging global configuration commands that define where and at what level these messages appear. The default is to log messages to the console at the debugging level (7).

How to Read System Error Messages

System error messages begin with a percent sign and are structured as follows:

%FACILITY-SEVERITY-MNEMONIC: Message-text

FACILITY is a code consisting of two or more uppercase letters that indicate the facility to which the message refers. A facility can be a hardware device, a protocol, or a module of the system software. Table B-1 lists the system facilities codes.


Table  B-1: Facility Codes
Code Facility
AAL5 ATM adaptation layer 5
ATM ATM specific errors
ATMCORE ATM core software
ATMSIG ATM signaling
CI Environment monitor
DCU <TBD>
DS3E3SUNI DS3/E3 drivers
LANE LAN emulation
Miscellaneous Miscellaneous error messages
OC3SUNI
OC12SUNI
Optical carrier 3 driver
Optical carrier12 driver
OIR Online insertion and removal
PNNI/IISP PNNI or IISP routing
SONICT Ethernet driver
T1E1SUNI T1 and E1 interfaces

SEVERITY is a single-digit code from 0 to 7 that reflects the severity of the condition. The lower the number, the more serious the situation. Table B-2 lists the severity levels.


Table  B-2: Error Message Severity Levels
Level Description
0 - emergency System unusable
1 - alert Immediate action needed
2 - critical Critical condition
3 - error Error condition
4 - warning Warning condition
5 - notification Normal but significant condition
6 - informational Informational message only
7 - debugging Appears during debugging only

MNEMONIC is a code that uniquely identifies the error message.

Message-text is a text string describing the condition. This portion of the message sometimes contains detailed information about the event, including terminal port numbers, network addresses, or addresses that correspond to locations in the system memory address space. Because the information in these variable fields changes from message to message, it is represented here by short strings enclosed in square brackets ([ ]). A decimal number, for example, is represented as [dec]. Table B-3 lists the representations of variable fields and the type of information in them.

The following is a sample system error message:

%SONICT-3-XMIT_ERR: TX Error [hex]

Table  B-3: Representation of Variable Fields in Error Messages
Representation Type of Information
[dec] Decimal number
[hex] Hexadecimal number
[char] Single character
[chars] Character string

Error Message Traceback Reports

Some messages describe internal errors and contain traceback information. This information is very important and should be included when you report a problem to your technical support representative.

The following sample message includes traceback information:

-Process= "Exec", level= 0, pid= 17
-Traceback= 1A82 1AB4 6378 A072 1054 1860

Error Messages

LightStream 10101 ATM switch software error messages.

AAL5 Errors

ATM adaptation layer 5 error messages.


Error Message    %AAL5-3-INTERNAL_ERROR: atm_output: Bad enctype

Explanation    ATM output error. Bad enctype.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %AAL5-3-INTERNAL_ERROR: aal5send: mmc_queuecell failed

Explanation    AAL5 send error. MMC queue cell failed.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %AAL5-3-INTERNAL_ERROR: Out of reassembly buffers

Explanation    Out of reassembly memory buffers error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %AAL5-3-INTERNAL_ERROR: AAL5 doesn't handle such large pkts

Explanation    AAL5 does not handle such large packets error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %AAL5-3-INTERNAL_ERROR: No more big aal5 pkts

Explanation    No more big AAL5 packets error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %AAL5-3-RXERR: [hex], orig [hex], port= [chars]

Explanation    Origin port number error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.

ATM Error Messages

Asynchronous Transfer Mode error messages


Error Message    %ATM-3-FAILCREATEVC: ATM failed to create VPI=[dec], VCI=[dec]) on Interface [chars], (Cause of the failure: [chars])

Explanation    This message can occur for the following unrelated reasons. Each reason is accompanied by a recommended action.

Recommended Action    If none of the previous actions fix the problem, copy the error message exactly as it appears and report it to your technical support representative.


Error Message    %ATM-4-MTUCALLMISMATCH: Incoming call from [ATM NSAP] has a mismatched maximum transmission unit - incoming forward PDU size is [dec], backward PDU size is [dec], interface [chars] MTU size is [dec][chars]

Explanation    The calling or called party has a maximum transmission unit (MTU) size configured that is different from the MTU size on the current interface.

Recommended Action    Either change the configured MTU size on the current interface to that of the caller's or called party's interface, or change the caller's or called party's interface to match the current interface.


Error Message    %ATM-4-NOMEM: Failed to allocate memory--[chars], ONEMIN

Explanation    The system attempted to allocate some memory but failed.

Recommended Action    Reduce the RAM usage or add more RAM to your switch.


Error Message    %ATM-3-UNSUPPORTED_QOS_PARMAS:ATM failed to create VC on Interface [ATM int],(Cause of the failure Invalid traffic shaping parameters or out of rate queues.

Explanation    The system attempted to create a virtual circuit (VC) with traffic shaping parameters not supported by the hardware.

Recommended Action    Either change the requested traffic shaping parameter to one that the hardware supports, or use existing parameters to avoid the need for a new rate queue.

ATM CORE Error Messages

ATM CORE software error messages.


Error Message    %ATMCORE-3-INTERNAL_ERROR: nvgenCttRow: [dec] stable row, bad sc

Explanation    Nonvolatile RAM generation connection traffic table row found with stable row and bad service category.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: rmPhyLogIf_2_ifId: Null logical RM cb

Explanation    Resource management physical and logical interface two interface ID error. Null logical resource management control block.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: rmPhyLogIf_2_ifId: Null swidb atm cb

Explanation    Resource management physical and logical interface two interface ID error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: rmPhyLogIf_2_ifId: Null sw atm ifcb

Explanation    Resource management physical/logical interface to interface ID error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: getIfPhyLogRmFromIfcb: Null sw atm ifcb

Explanation    Get interface physical and logical resource management control block from interface control block error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: getIfPhyRmFromIfcb: bad output if cbs

Explanation    Get interface physical/logical resource management control block from interface control block error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: isCpuIntf: bad if cbs

Explanation    CPU interface check error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createLogIfRm: Duplicate Logical interface

Explanation    Create logical interface resource management error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createLogIfRm: No Physical interface

Explanation    Create logical interface resource management error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createLogIfRm: No atmswdb

Explanation    Create logical interface resource management error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: setPhyPortMaxCr: Bad plimtype

Explanation    Set physical port maximum cell rate error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: atm_db is null

Explanation    Create physical interface resource management error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: atmswdb is null

Explanation    Create physical interface resource management error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: ifCb is null

Explanation    Create physical interface resource management error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: ifRm not null

Explanation    Create physical interface resource management error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: swidb is null

Explanation    Create physical interface resource management error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rm_if_init: Not ATM if

Explanation    Resource management interface initialization error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: No swidb

Explanation    Resource management logical interface creation error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: No atm_swdb

Explanation    Resource management logical interface creation error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: No ifCB

Explanation    Resource management logical interface creation error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: Can't get rcv ctt row

Explanation    Resource management logical interface creation error. Can't get receive connector traffic table row.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: Can't get xmt ctt row

Explanation    Resource management logical interface creation error. Can't get transmit connector traffic table row.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfDeleted: No swatmdb

Explanation    Resource management logical interface deletion error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmGetDefaultQosObj: bad input traffic

Explanation    Resource management get default quality of service object error. Bad input.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: sc_to_trafficParmSc: bad Service Category

Explanation    Service category to traffic parameter service category error. Bad service category.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: show_if_conn_hw: no CTT row

Explanation    Display interface hardware connection error. No control traffic table row.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: show_if_conn_hw: no ifCB

Explanation    Display interface hardware connection error. No interface control block.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: show_atm_int_rm: Cannot find phy if structure

Explanation    Display interface hardware connection error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: show_atm_int_rm: Cannot find phylog if structure

Explanation    Display interface resource management error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: printCttRow: [dec] rowindex, bad sc

Explanation    Print connection traffic table error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atm_rm_show_commands null csb

Explanation    ATM resource management show command error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atm_rm_show_commands: bad csb show type

Explanation    ATM resource management show command error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmCtt_init: Error allocating row [dec], error [dec]

Explanation    Resource management connection traffic table initialization error. Error allocating default at startup row.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: cfgCttCommands: can't release not-ready row

Explanation    Configuring connection traffic table error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atm_rm_show_commands null csb

Explanation    ATM resource management show command error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atm_rm_cfg_commands: nvgen default: should not happen

Explanation    Errors detected in nonvolatile RAM generation of connection traffic table.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atm_rm_cfg_commands: bad csb info

Explanation    ATM resource management configuration command error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: chg_phyif_qthresh_req: bad selector

Explanation    Change physical interface queue threshold request error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: nvgenParmLimits: bad parm limit selector

Explanation    Nonvolatile RAM generation parameter limits error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: nvgenParmLimits: bad parm limit service category

Explanation    Nonvolatile RAM generation parameter limits error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: nvgenStartOutputQ: bad queue value

Explanation    Nonvolatile RAM generation output queue error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: nvgenStartServCatOutQ: bad service category value

Explanation    Nonvolatile RAM generation start service category error. Bad service category selected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: nvgenTolerance: bad service category value

Explanation    Nonvolatile RAM generation output queue. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atm_rm_show_commands null csb

Explanation    ATM resource management show command error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atm_rm_int_cfg_commands: bad nvgen selector value

Explanation    ATM resource management initialization configuration command error. Bad nonvolatile RAM generation value selected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: isOutputQosOk: Bad sc

Explanation    Is output quality of service correct? Bad service category.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: isFlowPolicyOk: Bad sc

Explanation    Is flow policy OK? Bad service category.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: serviceCategoriesOk: Bad sc

Explanation    Are service categories correct? Bad service category.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: processIntfListConnResGetReq: Bad IfSelect

Explanation    Interface list connection reset get request error. Bad interface selection.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: processIgnoreRcacReq: more than 1 intf

Explanation    Resource call admission control request error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: processIgnoreRcacReq: no intf structure

Explanation    Resource call admission control request error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: processIgnoreRcacReq: bad sc

Explanation    Resource call admission control request error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacGetIntfConnRes: Null re/rsp pointer

Explanation    Resource management resource call admission control get interface connection resource. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacRelIntfConnRes: Null req pointer

Explanation    Resource management resource call admission control get interface connection resource. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacRelIntfConnRes: Bad sc

Explanation    Resource management resource call admission control get interface connection resource. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacRelIntfConnRes: Bad interface

Explanation    Resource management resource call admission control release interface connection resource. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmRcacAreTrafficParmConsistent: No ctt row

Explanation    Resource management resource call admission control, are traffic parameters consistent. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmRcacRelIntfConnRes: Bad interface

Explanation    Resource management resource call admission control release connection reset. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: allocNewStableRow: dup row

Explanation    Allocate new stable row error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: allocNewTransientRow: dup row

Explanation    Allocate new transient row error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: trafficIsCompCon: bad sc

Explanation    Traffic is not compatible to the connection error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmCtt_init: no chunk for Stable CTT

Explanation    Resource management connection traffic table error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmCtt_init: no chunk for Transient CTT

Explanation    Resource management connection traffic table initialization error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmCtt_init: Error allocating row 1

Explanation    Resource management connection traffic table initialization error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmCttStableRowAlloc: null request pointer

Explanation    Resource management connection traffic table stable row allocation error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttStableRowAlloc: Bad parm quals

Explanation    Resource management connection traffic table stable row allocation error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttRowGet: No SVC row

Explanation    Resource management connection traffic table row get request error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: rmTransientCttRowAct: null request pointer

Explanation    Resource management transient connection traffic table row acknowledgment. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttRowDetach: num Vxs attached <= 0

Explanation    Resource management connection traffic table row detach request error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttAreFlowsSame: sc different

Explanation    Resource management connection traffic table are flows the same error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttAreFlowsSame: bad sc

Explanation    Resource management connection traffic table are flows the same error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: rmCtt_chkDeleteRow: row to delete not found

Explanation    Resource management connection traffic table check row deletion error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQScThreshCfg: can't install if abr thresh

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: rm_changeAllIfAbrRrThresh: Null phy RM cb

Explanation    Resource management change all available bit rate interface request threshold. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: rm_switchChangeCellPriorityLimit: Couldn't install hw

Explanation    Resource management change cell loss priority limit error. Hardware error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmGlobalCfg: bad selector

Explanation    Resource management global configuration error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: checkChangePortMetrics: No ifRm

Explanation    Check change port matrix error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQCfg: Couldn't install hw

Explanation    Resource management physical interface output queue configuration error. Could not install hardware.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQScThreshCfg: bad selector

Explanation    Resource management physical interface output queue service category threshold configuration error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQScThreshCfg: can't install if abr thresh

Explanation    Resource management physical interface output queue service category threshold configuration error. Cannot install if available bit rate interface threshold in hardware.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQScThreshCfg: bad selector

Explanation    Resource management physical interface output queue service category threshold configuration error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfClsFlowCfg: bad selector

Explanation    Resource management physical interface cells flow configuration error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmIfTrParmLimitCfg: bad selector.

Explanation    Resource management physical interface traffic parameter limit configuration. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: deriveTrafTypeFromOid: no OID ptr

Explanation    Derive traffic type from object ID error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: k_atmTrafficDescrParamEntry_set: Bad rowStatus value

Explanation    ATM traffic description parameter entry configuration error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: setPhyIfStaticMetrics: Bad port type

Explanation    A set physical interface static metrics error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: initPhyIfPlatDepRmValues: Bad plim type

Explanation    Initialize physical interface platform dependent resource management values error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: getDefaultPhyIfOutQMaxSize: Bad queue

Explanation    Get default physical interface output queue maximum size error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: initPhyIfPlatDepRmValues: Bad queue.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: rmInstallInterfaceHardware: Can't install CPU Max q size

Explanation    Initial physical interface platform dependent resource management values error. Hardware error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: rmInstallInterfaceHardware: Can't install Max q size

Explanation    Resource management installation interface hardware error. Cannot install maximum queue size.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: rmInstallInterfaceHardware: can't install if abr thres.

Explanation    Resource management installation interface hardware error. Cannot install interface available bit rate threshold.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: rmInstallInterfaceHardware: Missing RM idb pointer

Explanation    Resource management installation interface hardware error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: rmInstallSwitchHardware: Can't install pri cell limit

Explanation    Resource management switch hardware installation error. Cannot install priority limit.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: selectTrafficValue: Bad traffic parm

Explanation    Select traffic value error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: selectTraffic: Bad sc

Explanation    Select traffic value error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: outputQosValueOk: Bad MetricAttr

Explanation    Output queue quality of service value error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: accumulateOutputQosMetric: Bad sc

Explanation    Accumulate output quality of service metric error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: trafficCompleteConsistent: Bad sc

Explanation    Traffic complete and consistent error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: flowTrafficParmLimitsOk: Bad sc

Explanation    Traffic flow parameter limits error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: canAdmitP2mpFlow: Bad flow

Explanation    Can admit point to multipoint flow error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: canAdmitTraffic: Bad sc

Explanation    Can admit point to multipoint flow error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: allocFlowEbw: Bad sc

Explanation    Allocate flow Ebw error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: relFlowEbw: Bad sc

Explanation    Release flow Ebw error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: rm_changeConnHalfLeg: no CTT row

Explanation    Resource management change connected half leg error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: rm_backgroundChangeIntfConnParm: no ifCB

Explanation    Resource management background change interface connection parameter error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: rm_backgroundChangeIntfParm: No phy if am cb

Explanation    Resource management background change interface connection parameter error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: derivePifIM: Bad If type

Explanation    Derive PifIM error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmInstallIfPacing: Can't install port pacing

Explanation    Resource management interface installation pacing error. Cannot install port pacing.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: convertRowScToSnmpFmt: Bad sc

Explanation    Convert service category row to SNMP format error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: sameTrafficParms: Bad sc

Explanation    Same traffic parameters error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: convertIntToExtRowData: Bad sc

Explanation    Convert interface to extract row data. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmGetTransmitOutputQueue: Bad sc

Explanation    Resource management get transmit output queue error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmIsFeatureCardQHiPri: Bad sc

Explanation    Resource management is feature card high priority error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: fetchPhyIfI: Bad port type

Explanation    Fetch physical interface error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: ls1010_atmcore_rmGetInputUpcParms: Null input ptrs

Explanation    Resource management get input usage parameter control parameter error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmGetInputUpcParms: bit rate too large

Explanation    Resource management get input usage parameter control parameter error. Bit rate too set too high.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmGetInputUpcParms: no if log rm cb

Explanation    Resource management get input usage parameter control parameter error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmGetTransmitQueueThresh: bad input

Explanation    Resource management get transmit queue threshold error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmGetTransmitQueueThresh: bad output if cbs

Explanation    Resource management get transmit queue threshold error.A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmConnGetFeatCardTxQThresholds: bad input

Explanation    Resource management connection get feature card transmit queue threshold error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmConnGetFeatCardTxQThresholds: bad output if cbs

Explanation    Resource management connection get feature card transmit queue threshold error. A data structure inconsistency was detected.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atm_rm_show_commands null csb

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atm_rm_show_commands null csb return

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmCtt_init: no chunk for Stable CTT

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmCtt_init: no chunk for Transient CTT

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmCttStableRowAlloc: null request pointer

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: Can't get rcv ctt row

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: Can't get xmt ctt row

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: No atm_swdb

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: No ifCB

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: No swidb

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfDeleted: No swatmdb

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacGetIntfConnRes: Null req/rsp pointer.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacReduceIntfConnRes: Bad interface.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacReduceIntfConnRes: Bad sc.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: checkChangePortMetrics: No ifRm. return;

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createLogIfRm: Duplicate Logical interface.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createLogIfRm: No atmswdb.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createLogIfRm: No Physical interface.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: atm_db is null.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: atmswdb is null.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: ifCb is null.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: rmTransientCttRowAct: null request pointer

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-2-INTERNAL_CRITICAL: setPhyPortMaxCr: Bad plimtype.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: allocNewStableRow: dup row freeRowStruct(row)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: allocNewTransientRow: dup row

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_collectPnniMetrics: Bad interface.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rm_derivePnniMetricCellRates: Bad sc.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttAreFlowsSame: bad sc

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttAreFlowsSame: sc different.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttRowDetach: num Vxs attached <= 0

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttRowGet: No SVC row.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmGetDefaultQosObj: bad input traffic

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmGetIntfLineCellRate: No RM control block on interface.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmGlobalCfg: bad selector.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmIfTrParmLimitCfg: bad selector.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmIfTrParmLimitCfg: bad selector.return(RMMGT_CFG_RESULT_BAD_VALUE)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfClsFlowCfg: bad selector. return(RMMGT_CFG_RESULT_BAD_VALUE)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQCfg: bad 25 Mbps port.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQScThreshCfg: bad 25 Mbps port.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQScThreshCfg: bad selector.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: copyAbrRrThresh: No hwidb

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: copyAbrRrThresh: No phy intf rm cb

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: copyClsBwUpdateCrs: No rm cb

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: copyQMaxSizeParamsChgPortMetrics: No hwidb

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: copyQMaxSizeParamsChgPortMetrics: No phy intf rm cb

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: errString

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: errStringfreeRowStruct(row)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: installRmPhyIfClsFlowCfg: bad 25 Mbps port.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: isFlowPolicyOk: Bad sc. setNegativeRspCode(ifRm,req,rsp,

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: k_atmTrafficDescrParamEntry_set: Bad rowStatus value.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: nvgenOutputThresh: No hwidb

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: processIgnoreRcacReq: bad sc.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: processIntfListConnResGetReq: Bad IfSelect.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: rm_switchChangeCellPriorityLimit: bad priority.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMCORE-3-INTERNAL_ERROR: str

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.

ATM Signaling Errors

ATM signaling error messages.


Error Message    %ATMSIG-3-ATMSIG_PRTY_DELETE_FAILED: svc->svc_namestring, svc->vpci, svc->vci, (svc->callRef & ATMSIG_CALLREF_VALUEMASK), (party ? party->endpointRef

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-ATMSIG_PRTY_INSERT_FAILED ,partnerSvc->svc_namestring, partnerSvc->vpci, partnerSvc->vci, (partnerSvc->callRef & ATMSIG_CALLREF_VALUEMASK), (partnerParty ? partnerParty->endpointRef

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-ATMSIG_PRTY_INSERT_FAILED: svc->svc_namestring, svc->vpci, svc->vci, (svc->callRef & ATMSIG_CALLREF_VALUEMASK), (svc->curr_party ? svc->curr_party->endpointRef

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-ATMSIG_SVC_INSERT_FAILED: destSvc->svc_namestring, destSvc->vpci, destSvc->vci, (destSvc->callRef & ATMSIG_CALLREF_VALUEMASK), (destSvc->rootParty ? destSvc->rootParty->endpointRef : 0), destSvc)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-ATMSIG_SVC_INSERT_FAILED: svc->svc_namestring, svc->vpci, svc->vci, (svc->callRef & ATMSIG_CALLREF_VALUEMASK), (svc->curr_party ? svc->curr_party->endpointRef : 0), svc);
errmsg(&msgsym(UNEXPECTEDEVENT,SCHED)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-ENQFAIL: enqueue atmsig_cb.mgmtapi_inqueue errmsg(&msgsym(UNEXPECTEDEVENT, SCHED)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-ENQFAIL: enqueue acctGlob.mymsg_inqueue free(msg) errmsg(&msgsym(UNEXPECTEDEVENT,SCHED)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-ENQFAIL: enqueue atmsig_cb.mgmtapi_inqueue msg->err_code = ATMSIG_MGMT_API_INTERNAL_ERROR

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-ENQFAIL: enqueue atmsig_cb.mgmtapi_inqueue free(msg)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-ENQFAIL: enqueue atmsig_cb.pnni_queue atm_ ys_msg->ret_code = IPC_ASYNC

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-ENQFAIL: enqueue atmSig_outputQ

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-FAILXCONN: xconn fail

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-INVPNNIMSG :
Invalid msg from routing/pnni : error return code No memory atmsys_get_buf for next_port_req No memory atmsys_get_buf for source_route_req No buffer for sending Setup message No buffer for sending Call Proceeding message No buffer for sending Connect message No buffer for sending Connect Ack message No buffer for sending Release message No buffer for sending Release Comp message No buffer for sending Status message No buffer for sending Status Enquiry message No buffer for sending Restart message No buffer for sending Restart Ack message No buffer for xfer Setup message No buffer for sending Connect message No buffer for sending Add Party message No buffer for sending Status message No buffer for sending AddPartyAck message No buffer for sending AddPartyRej message No buffer for sending DropParty message No buffer for sending DropPartyAck message No buffer for sending Begin Pdu No buffer for sending Begin Ack Pdu No buffer for sending Begin Rej Pdu No buffer for sending End Pdu No buffer for sending End Ack Pdu No buffer for sending Resync Pdu No buffer for sending Resync Ack Pdu No buffer for sending Ustat Pdu No buffer for sending Stat Pdu No buffer for sending Poll Pdu

Explanation    An internal error occurred.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: number of ports > MAX

Explanation    Invalid massage received from routing. Number of ports greater than maximum.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: NULL port list

Explanation    Invalid massage received from routing. No ports can be found to route this call.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: NULL message

Explanation    Invalid massage received from PNNI routing error. Null message received.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: msg type not valid

Explanation    Invalid massage received from routing. Message type not valid.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: source proc not valid

Explanation    Invalid massage received from routing. Source process not valid. It must be a routing module.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: dest proc not valid

Explanation    Invalid massage received from routing. Destination process not valid. It must be a signaling module.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: NULL curr party

Explanation    Invalid massage received from routing. Null current party.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: NULL SVC

Explanation    Invalid massage received from routing. No signaling control block.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: msg code not resp

Explanation    Invalid massage received from routing. Message code not responding.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: msg vers bad

Explanation    Invalid massage received from routing. Message version bad.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: NULL port_rsp message

Explanation    Invalid massage received from routing. Null message.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-FAILHALFLEGREM: halfLeg removal failed, removeHalfLeg

Explanation    ATM signaling failed half-leg removal error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-FAILHALFLEGREM: 2nd halfleg failed, Get 2nd half leg failure. no ifcb

Explanation    ATM signaling failed to remove the second half-leg of a connection.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-FAILASSERT: [chars]

Explanation    ATM signaling finds an internal critical error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-NOMEM: [chars]

Explanation    ATM signaling could not allocate memory.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-NOSVC: no SVC, atmSig_findPartyBlockByRef

Explanation    ATM signal control block is not found for a party message.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %ATMSIG-3-NOSVC: no SVC, atmSig_input

Explanation    ATM signal control block is not found for an input message.

Recommended Action    If this message occurs, contact your technical support representative for assistance.

CI Errors

Environment monitor error messages.


Error Message    %CI-3-PSTYPE:"***WARNING*** Incompatible power supply types -
One is AC, other is DC.

Explanation    AC and DC power supply can not be mixed in the same chassis.

Recommended Action    Remove either the AC or DC power supply.


Error Message    %CI-3-SHUTDOWN: Shutting down due to overheat.

Explanation    The system has shutdown because the internal chassis temperature is too high.

Recommended Action    Check the system fan and the area around the chassis.


Error Message    %CI-3-NOFORK: Couldn't start environment polling daemon

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %CI-6-PSFANOK: Power supply fan [dec] OK

Explanation    System power supply has no error.

Recommended Action    This message is provided for information only.


Error Message    %CI-3-TEMP: Temperature overheat

Explanation    System temperature overheat error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %CI-6-TEMPOK: Temperature OK

Explanation    System temperature has no error.

Recommended Action    This message is provided for information only.


Error Message    %CI-3-BLOWER: Fan failure

Explanation    System Fan failure error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %CI-6-BLOWEROK: Fan OK

Explanation    System fan has no error.

Recommended Action    This message is provided for information only.


Error Message    %CI-3-PSFAIL: Power supply [dec] failure

Explanation    System power supply number failure error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %CI-3-PSOK: Power supply [dec] OK

Explanation    System power supply number has no error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %CI-6-PSCHANGE: Power supply [dec] changed from [chars] [chars] to [chars]

Explanation    Power supply status has changed error.

Recommended Action    This message is provided for information only.

Recommended Action    None

DCU Error Messages

DCU error messages.


Error Message    %DCU-1-NOMEMORY: [chars]: DCU keep-alive failure, card reset

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %DCU-1-NOMEMORY: cardDatabaseArray, crashdump (0)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %DCU-1-NOMEMORY: Unit [dec], IDB subblock

Explanation    The unit described has a memory error for the IDB structure subblock.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %DCU-1-NOMEMORY: Unit [dec], atm_db

Explanation    The unit described has a memory error for the ATM database.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %DCU-1-NOMEMORY: Unit [dec], port database

Explanation    The unit described has a memory error for the port database.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %DCU-1-NOMEMORY: Unit [dec], no memory for [chars] IDB structure

Explanation    The unit described has a memory error for the IDB structure.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %DCU-1-NOMEMORY: Unit [dec], no memory for [chars] ds structure

Explanation    The unit described has a memory error for the digital system structure.

Recommended Action    If this message occurs, contact your technical support representative for assistance.

DS3E3SUNI Errors

DS3E3SUNI driver error messages.


Error Message    %DS3E3SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] IDB structure

Explanation    The unit described has a memory error for the IDB structure.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %DS3E3SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] ds structure

Explanation    The unit described has a memory error for the digital system structure.

Recommended Action    If this message occurs, contact your technical support representative for assistance.

LAN Emulation Error Messages

LAN emulation software error messages.


Error Message   
%LANE-3-BADILMI: Unexpected ILMI event [dec]

Explanation    An internal error occurred.

Recommended Action    This error should not occur. Download the system error log, then call your technical support representative and provide the log, the error message, and the switch configuration.


Error Message   
%LANE-3-BADNAME: ELAN name must be 1-32 characters long

Explanation    An emulated LAN (ELAN) name was entered in a command that is longer than 32 characters. The LANE standard v1.0 requires a name that is 32 characters or less in length.

Recommended Action    Re-enter a shorter name.


Error Message   
%LANE-3-BADTYPE: LAN Emulation supports only Ethernet type

Explanation    The user specified a Token-Ring-emulated LAN, which is not currently supported.

Recommended Action    Specify an Ethernet-emulated LAN. Future software releases will support Token Ring ELANs.


Error Message   
%LANE-3-LANE_LESBUS_UP: LES/BUS coming up from previous command

Explanation    The lane server-bus command was reissued to start the LANE service components while the switch was trying to execute a previously issued lane server-bus command.

Recommended Action    Wait for the initial lane server-bus command to either succeed or fail. The status of the server bus can be checked via the show lane server-bus interface sub-interface name command. The previous command can also be cancelled with the no lane server-bus command. If these steps fail to clear the problem, issue the shutdown command followed by a no shutdown command cycle on the subinterface, or on the whole interface. As a last resort, issue the no interface sub-interface name command followed by the shutdown, no shutdown command cycle.


Error Message   
%LANE-3-LANE_SIG_CHAIN: not in [chars] chain ([hex] [hex])

Explanation    An internal error occurred while system routines were handling ATM signaling messages for LANE.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-3-LANE_SIG_ERR: [chars]

Explanation    An internal error occurred while system routines were handling ATM signaling messages for LANE.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-3-LANE_SIG_INV_MSG: invalid msg received ([hex] [hex] [hex])

Explanation    An internal error occurred while system routines were handling ATM signaling messages for LANE.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-3-LANE_SIG_INV_STATE: invalid [chars] req in state [dec] ([hex])

Explanation    An internal error occurred while system routines were handling ATM signaling messages for LANE.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-6-LEC: [chars]

Explanation    A hardware or software error occurred.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-3-LEC_BADAD: [chars] LEC unable to compute ATM address

Explanation    The client cannot obtain an ATM address from the given configuration, or auto-assignment failed to get an ATM prefix from the switch.

Recommended Action    If you expect the switch to assign the prefix to the switch, check that the Interim Local Management Interface (ILMI) is functional and the switch has a prefix configured. Otherwise, confirm that the client has an address in the NVRAM configuration.


Error Message   
%LANE-3-LEC_CFG: [chars] CFG_REQ failed, [chars] (LECS returned [dec])

Explanation    A software or hardware error occurred.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-3-LEC_CONTROL_MSG: Received bad control message on interface > [chars], 10*ONESEC

Explanation    The client received a control message over one of its control virtual channel connections (VCCs) that failed the header check.

Recommended Action    This message indicates a noninteroperable LANE configuration server, LANE server, or LANE client implementation on the emulated LAN.


Error Message   
%LANE-3-LEC_ERR: [chars], 10*ONESEC

Explanation    A software or hardware error occurred.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-6-LEC_INFO: [chars]

Explanation    A software or hardware error occurred.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-3-LEC_JOIN: [chars] JOIN failed, [chars] (LES returned [dec])

Explanation    A software or hardware error occurred.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-3-LEC_LISTEN: [chars] listen failed on [chars]

Explanation    The client failed an attempt to listen on a particular ATM address.

Recommended Action    Reconfigure the client ATM address. It is conflicting with another component on the ATM Interface Processor (AIP) for the same ATM address.


Error Message   
%LANE-3-LEC_SIGNAL: Unexpected SigAPI event [dec], 10*ONESEC

Explanation    ATM signaling sent the client an unexpected message type.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-4-LEC_STATE_ERROR: State: [dec], Event [dec]

Explanation    A hardware or software error occurred.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-6-LEC_TIMER: Timer [chars] expired

Explanation    A hardware or software error occurred.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-3-LECS_ERR: [chars]

Explanation    An internal consistency error occurred.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-4-LECS_WARN: [chars]

Explanation    The LANE configuration server address could not be registered with or de-registered from the switch, using Interim Local Management Interface (ILMI).

Possible causes

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-3-LSV_ADDR: [chars] elan [chars] unable to register LES/BUS ATM addr

Explanation    A hardware or software error occurred.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.


Error Message   
%LANE-3-LSV_BADAD: <interface> elan <ELAN name> unable to compute [chars] ATM address

Explanation    Software was unable to compute an ATM address based on the ATM address template given. The characters in chars (see above display) will be either "BUS" (broadcast-and-unknown), "server," or "config server" in the actual error message.

Recommended Action    Enter a correct ATM address template for the LANE component ("BUS," "server," or "config server") named in the error message.


Error Message   
%LANE-3-LSV_CRASH: <interface> elan <ELAN name> unrecoverable error [chars]

Explanation    An internal error occurred.

Recommended Action    This error should not occur. Download the system error log, then call your technical support representative and provide the log, the error message, and the switch configuration.


Error Message   
%LANE-3-LSV_DUPATM: <interface> elan <ELAN name> client [dec] duplicate ATM address registration <ATM address>

Explanation    An attempt was made by the specified LANE client to register a MAC address and ATM address pair that duplicated an ATM address already registered to another LANE client.

Recommended Action    Use the show lane server command to list the registered addresses in the LANE server reporting the error. Correct one of the two LANE clients that is trying in error to use the same ATM address.


Error Message   
%LANE-3-LSV_DUPID: <interface> elan <ELAN name> duplicate LECID [dec]

Explanation    An attempt was made to define two different server-direct PVCs both on the same subinterface (same LANE server) and both for the same client (LECID).

Recommended Action    Delete one of the lane pvc commands that has this duplicated LECID.


Error Message   
%LANE-3-LSV_DUPMAC: <interface> elan <ELAN name> client [dec] duplicate MAC address registration [enet]

Explanation    An attempt was made by the specified LANE client to register a MAC address and ATM address pair that duplicated a MAC address already registered to another LANE client.

Recommended Action    Use the show lane server command to list the registered addresses in the LANE server reporting the error. Correct one of the two LANE clients that is trying in error to use the same MAC address.


Error Message   
%LANE-4-LSV_LECID: <interface> elan <ELAN name> LECIDs exhausted, 10*ONESEC

Explanation    The LANE server specified has 65279 clients. No more can be added.

Recommended Action    Change the configurations to avoid trying to have more than 65279 LANE clients on this server.


Error Message   
%LANE-3-LSV_MCAST: <interface> elan <ELAN name> unable to create [chars] MC group

Explanation    An internal error occurred.

Recommended Action    This error should not occur. Download the system error log, then call your technical support representative and provide the log, the error message, and the switch configuration.


Error Message   
%LANE-3-LSV_NOREG: <interface> elan <ELAN name> client [dec] unable to register MAC address [enet]

Explanation    An internal error occurred.

Recommended Action    This error should not occur. Download the system error log, then call your technical support representative and provide the log, the error message, and the switch configuration.


Error Message   
%LANE-6-MAKE17: Created vcd [dec] (PVC [dec]/[dec]) for config server access

Explanation    The LANE software created a PVC (normally 0/17) for accessing the LANE configuration server.

Recommended Action    Informational message only. No action required.


Error Message   
%LANE-3-NAMECHG: Attempt to change ELAN name

Explanation    Both the LANE client and the LANE server/broadcast-and-unknown server may have an emulated LAN name specified in the configuration via the lane server-bus and lane client commands. If both specify the emulated LAN name, then the name cannot be changed by re-entering just one of the commands.

Recommended Action    Use the no lane server-bus command to delete the server/broadcast-and-unknown server or the no lane client command to delete the client. Then, the other of the two commands can be re-entered with another emulated LAN name. Finally, re-enter the deleted command with the new emulated LAN name.


Error Message   
%LANE-3-NEWPREF: <interface> elan <ELAN name> ATM address prefix [chars]

Explanation    Entering a new ATM address template for some LANE component caused the specified LANE server or bus to drop all clients and restart.

Recommended Action    Informational message only. No action required.


Error Message   
%LANE-3-NOILMI: ILMI service registration failed

Explanation    The Interim Local Management Interface (ILMI) feature is not included in the software build running on the switch.

Recommended Action    Reload switch with software that includes the ILMI feature.


Error Message   
%LANE-3-NOINT: <interface> still destroying old sub-interface

Explanation    An attempt was made to create a new subinterface while a previous version of the subinterface was still being destroyed.

Recommended Action    Wait a minute and try again. If failure still occurs, try shutting down the main interface. Rebooting may be required to recover in extreme cases.


Error Message   
%LANE-3-NOREGATM: <interface> cannot register <ATM address> with ILMI

Explanation    An attempt to register the given ATM address with the ATM switch failed. This failure can occur because the ATM switch is down or misconfigured. The registration will be retried.

Recommended Action    If the situation persists after a number of attempts, and the switch is up, the configuration of the switch and switch must be examined. The most likely cause is that ATM address being registered is not compatible with the parameters -- for example, the ATM address prefix -- configured in the switch. Correct the configuration.


Error Message   
%LANE-3-NOVCD: VCDs exhausted

Explanation    When trying to create PVC 0/17, the switch ran out of PVC resources.

Recommended Action    The number of PVCs can be increased with the atm maxvc command.


Error Message   
%LANE-3-PVCBAD: <interface> elan <ELAN name> PVC vcd [dec] has no [chars] assigned

Explanation    The characters in chars (see above display) will be either "ATM address" or "LECID." This message is reported when a permanent virtual circuit (PVC) is created without all the necessary information included in the lane pvc command.

Recommended Action    Include a lane pvc command with the information appropriate for the PVC.


Error Message   
%LANE-3-PVCLECS: Unable to create PVC [dec]/[dec]

Explanation    An attempt to create the named PVC failed. The most likely reason is that a PVC was defined on the same or another subinterface with the same virtual path identifier-virtual channel identifier (VPI-VCI) pair, but with a different encapsulation or usage type.

Recommended Action    Correct the configuration.


Error Message   
%LANE-3-REGSTATE: ILMI event in state [dec]

Explanation    An internal error occurred.

Recommended Action    This error should not occur. Download the system error log, then call your technical support representative and provide the log, the error message, and the switch configuration.


Error Message   
%LANE-3-TYPECHG: Attempt to change ELAN type

Explanation    Both the LANE client and the LANE Server/BUS may have an ELAN type specified in the configuration via the lane server-bus and lane client commands as either Ethernet or Token Ring. If both, specify the type; the type cannot be changed by re-entering just one of the commands.

Recommended Action    Use the no lane server-bus command to delete the server-bus or the no lane client command to delete the client. Then, the other of the two commands can be re-entered with a new type. Finally, re-enter the deleted command with the new type.


Error Message   
%LANE-5-UPDOWN: [chars] [chars] [chars]: [chars] changed state to [chars]

Explanation    A software or hardware error occurred.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

Miscellaneous Errors

Miscellaneous error messages.


Error Message    %FPGA-3-ABR: ABR FPGA don't reset properly, Control Register=%x

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %FPGA-3-DONE_PIN: Done pin or Status pin isn't pull low, FPGA# [dec]

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %FPGA-3-DOWNLOAD: Download Fail, FPGA# [dec]

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %FPGA-3-MCAST: Multicast FPGA don't reset properly, Control Register=%x

Explanation    The ASP Feature Card did not reset.

Recommended Action    Try resetting the switch again.


Error Message    %FPGA-3-NOFORK: Feature Card version invalid/old. Feature Card Version:[dec].[dec], ASP Version:[dec].[dec]

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %FPGA-3-STATUS_PIN: Error in status pin, FPGA# [dec]

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %FPGA-3-TRAFF: Traffic FPGA don't reset properly, Control Register=%x

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %FPGA-3-TYPE: ***WARNING*** Invalid feature card type - use higher version of software: [hex]

Explanation    The ASP Feature Card, Version II, will only work with IOS Version 11.2 or later software.

Recommended Action    Update your LightStream 1010 IOS software to Version 11.2 or later.


Error Message    %LINK-3-TOOBIG: Interface [chars] Output packet size of [dec] bytes too big

Explanation    Interface output packet has too many bytes.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %RSP-3-IDPROM: Bad or missing ID EEPROM, controller type [dec]

Explanation    A bad or missing ID EEPROM error occurred on the controller type described.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %RSP-2-NOMEMORY: No memory available for OIR process

Explanation    No memory is available to allow hot-swapping to store the current PAM interface configuration.

Recommended Action    If this message occurs, contact your technical support representative for assistance.

OC3SUNI and OC12 SUN Errors

OC3SUNI and OC12SUNI driver error messages.


Error Message    %OC3SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] IDB structure

Explanation    The unit described has a memory error for the IDB structure.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %OC3SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] ds structure

Explanation    The unit described has a memory error for the ds structure.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %OC12SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] IDB structure

Explanation    The unit described has a memory error for the interface data block structure.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %OC12SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] ds structure

Explanation    The unit described has a memory error for the ds structure.

Recommended Action    If this message occurs, contact your technical support representative for assistance.

OIR Errors

Online insertion and removal error messages.


Error Message    %OIR-3-SHUTDOWN: Shutting down due to overheat

Explanation    System shutdown due to overheat error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %OIR-6-INSCARD: Card inserted in slot [dec], subcard [dec], interfaces administratively shutdown

Explanation    Card inserted in the slot, sub card, port, and interfaces described has been administratively shutdown.

Recommended Action    This message is provided for information only.


Error Message    %OIR-6-REMCARD: Card removed from slot [dec], subcard [dec], interfaces disabled

Explanation    Card inserted in the slot, sub card, port, and interfaces described has been disabled.

Recommended Action    This message is provided for information only.


Error Message    %OIR-3-LONGSTALL: Long bus stall ([dec] [chars]), the new PAM may not seated properly. Please remove it and try again.

Explanation    While hot-swapping a PAM the system has detected the card is not seated properly.

Recommended Action    Remove the card and reinsert it.

PNNI/IISP Errors

PNNI and IISP routing error messages.


Error Message    %PNNI-2-NO_INTERNAL_NUMBER:

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: failed to get the argument to pnni_hello process, pid = , pdb->pid

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Can't find node included in ACK header: , *pnni_nodeid_string(node_id)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Cannot relocate PTSE component

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR : Can't find node included in ACK header: pnni_nodeid_string(node_id)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Hello state machine error in state error_msg, pnni_idb->port_id

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: IF table full, cannot add new interface port

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Unknown timer type, expired_timer

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Attempt to add a PTSE but Node doesn't exist pnni_nodeid_string(node_id), ptse_id

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Cannot add NNI interface port

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: retbuffer(pak)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: PNNI relocation of addr failed, could not find pfx

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Can't find our own node in PTSE database

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Cannot add NNI interface, uninitialized pointers ios_idb

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Cannot locate neighbor to be deleted

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Duplicate node , pnni_nodeid_string(node_id)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Duplicate PTSE of, pnni_nodeid_string(node_id), ptse_id)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Getting Node Id For An Invalid Node, , node)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: IISP failed to get, the argument to iisp_router process, pid = , pdb->pid)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Internal Nbr Number Stack Overflow

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Null element to deq_ptse

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: NULL node in ptsedb ID, , ptsedb->ptse_data->ptse_id)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Out Of Parse Buffers

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: PNNI: Service orig timer, but PTSE is NULL!!!, , ptsedb)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Rcv DS in an invalid nbr state

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Received API message to create an interface for an existing port,, port)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Remove neighbor with interface list not empty

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: removing our own PTSE ID 1, \nplse collect \show atm pnni trace buf, ptse)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: rxmt timer with no element.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-3-INTERNAL_ERROR: Unrecognized req msg from signaling, , msg->op_code

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: IISP failed to get the argument to iisp_router process

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-BADPACKET: Hello, len_err_str, ((pnni_ptse_hdr_t *)hello)->ptse_type, TLV_LEN(hello)

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-BADPACKET: Invalid pkt: length shorter than header size [dec], phdr->length

Explanation    Unrecognized type of PNNI packet has been received.

Recommended Action    Check the sender of the packet for any possible problem.


Error Message    %PNNI-4-BADPACKET: Invalid pkt: unrecognized packet type [dec], TLV_TYPE( phdr )

Explanation    Unrecognized type of PNNI packet has been received.

Recommended Action    Check the sender of the packet for any possible problem.


Error Message    %PNNI-4-BADPACKET: Nodal REQ, Contains Unknown Mandatory IG, req_hdr, req_hdr->type

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-BADPACKET: PTSE ACK, Has No Nodal PTSE Acks, ack_pkt->type, TLV_LEN((pnni_tlv_t *)ack_pkt))

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-BADPACKET: PTSE ACK, Has No Nodal PTSE Acks, pnni->type, TLV_LEN((pnni_tlv_t *)pnni))

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-BADPACKET: PTSE ACK, len_err_str, ((pnni_ptse_hdr_t *)ptse_ack)->ptse_type, TLV_LEN(ack))

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-BADPACKET: PTSE len_err_str, ((pnni_ptse_hdr_t *)ptse)->ptse_type, TLV_LEN((pnni_tlv_t *)ptse))

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-BADPACKET: PTSP, Has Unknown Mandatory IG At Top Level, ptsp, ptsp->type

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-BADPACKET: REQ Contains Unknown Mandatory IG At Top Level req_pkt, req_pkt->type

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-BADPACKET: REQ error_msg, 0, 0); } req_hdr = pnni_get_next_tlv((pnni_tlv_t)pnni, (pnni_tlv_t)req_hdr

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-BADPACKET: REQ, len_err_str, ((pnnihdr_t *)req)->type, TLV_LEN(req))

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-BADROUTEREQ: msg->op_code )

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-CONFIG_ERROR: Port looped-back, cannot form adjacency

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-CONFIG_ERROR: Missing PNNI VC on NNI interface.

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-CONFIG_ERROR: Neighbor in different PeerGroup

Explanation    An internal error occurred.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: PNNI failed to set the argument to pnni_router process

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: PNNI failed to set the argument to pnni_update process

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-ADDRESS_EXIST: Address derived from the switch's prefix by soft PVC manager [chars] clashes with existing address in prefix table

Explanation    Automatic soft PVC port address assignment fails. Address derived from the switch's prefix for soft PVC port clashes with an existing address in the prefix table.

Recommended Action    If possible, assign a new MAC address to the end system that causes the clash.


Error Message    %PNNI-4-ATM_SYS_ERROR: Error: Incorrect API version. Mismatched API message version received by PNNI

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: Cannot add NNI interface. An attempt to add an NNI interface failed

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: Received API message to create an interface for an existing port

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR:Received API message to delete an interface that PNNI does not know of

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-ATM_SYS_ERROR: Error: Received Unrecognized API message

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: Unrecognized req msg from signaling [hex]

Explanation    Unrecognized request message from signaling error process.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-BADPACKET: Invalid REQ pkt: [chars] [dec] [dec]

Explanation    Invalid PNNI request packet has been received.

Recommended Action    Check the sender of the packet for any possible problem.


Error Message    %PNNI-4-BADPACKET: Invalid DS pkt: Type in header is not Nodal PTSE summaries (512), type [dec]

Explanation    Invalid PNNI database summary packet has been received.

Recommended Action    Check the sender of the packet for any possible problem.


Error Message    %PNNI-4-BADPACKET: Invalid DS pkt: Length in hdr shorter than smallest possible, len [dec], ds_data->length

Explanation    Invalid PNNI database summary packet has been received.

Recommended Action    Check the sender of the packet for any possible problem.


Error Message    %PNNI-4-BADPACKET: Invalid DS pkt: Bad length in node [chars], eDS PTSE sum len [dec], left [dec], count [dec], left [dec]

Explanation    Invalid PNNI database summary packet has been received.

Recommended Action    Check the sender of the packet for any possible problem.


Error Message    %PNNI-4-INTERNAL_ERROR: NULL node in ptsedb ID [hex]

Explanation    Invalid PNNI database summary packet has been received.

Recommended Action    Check the sender of the packet for any possible problem.


Error Message    %PNNI-4-INTERNAL_ERROR: Rev DS in an invalid nbr state

Explanation    Invalid neighbor state found.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: Remove neighbor with interface list not empty

Explanation    A neighbor is being removed but interface list still shows some interface.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: Cannot locate neighbor to be deleted

Explanation    Cannot locate a neighbor to be deleted.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: Internal Nbr Number Stack Overflow

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-CONFIG_ERROR: Configuration Error: Port looped-back, cannot form adjacency

Explanation    PNNI detects a port looped back to itself.

Recommended Action    Check the sender of the packet for a possible problem.


Error Message    %PNNI-4-BADPACKET: Invalid ACK pkt: [chars]

Explanation    Invalid ACK packet has been received.

Recommended Action    Check the sender of the packet for a possible problem.


Error Message    %PNNI-4-INTERNAL_ERROR: rxmt timer with no element

Explanation    Invalid ACK packet has been received.

Recommended Action    Check the sender of the packet for a possible problem.


Error Message    %PNNI-4-BADPACKET: Invalid PTSP pkt: Bad Type in PTSE header: [dec]

Explanation    Invalid ACK packet has been received.

Recommended Action    Check the sender of the packet for a possible problem.


Error Message    %PNNI-4-BADPACKET: Invalid PTSP pkt: Unknown type in PTSE header: [dec],)

Explanation    Invalid PTSP packet has been received.

Recommended Action    Check the sender of the packet for a possible problem.


Error Message    %PNNI-4-BADPACKET: Invalid PTSP pkt: Inconsistent type between PTSE header and: PTSE content [dec] [dec]

Explanation    Invalid PTSP packet has been received.

Recommended Action    Check the sender of the packet for a possible problem.


Error Message    %PNNI-4-BADPACKET: Invalid PTSP pkt: PTSE len does not add up to total PTSE len in header [dec] [dec]

Explanation    Invalid PTSP packet has been received.

Recommended Action    Check the sender of the packet for a possible problem.


Error Message    %PNNI-4-BADPACKET: Invalid PTSP pkt: IG with type matching the PTSE type is missing: from PTSE [dec] [dec]

Explanation    There is no information group inside this PTSE that has the same type as the type in the PTSE header.

Recommended Action    Check the sender of the packet for a possible problem.


Error Message    %PNNI-4-BADPACKET: Invalid PTSP pkt: Bad checksum in PTSE ID: [dec]

Explanation    Invalid PTSP packet has been received.

Recommended Action    Check the sender of the packet for a possible problem.


Error Message    %PNNI-4-BADPACKET: Invalid PTSP pkt: [chars]

Explanation    Invalid PTSP packet has been received.

Recommended Action    Check the sender of the packet for a possible problem.


Error Message    %PNNI-4-INTERNAL_ERROR: Can't find node included in ACK header: [chars] , pnni_nodeid_string(node_id)

Explanation    Cannot locate node in an ACK packet.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: Hello state machine error in state [chars] , error_msg

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-CONFIG_ERROR: Configuration Error: Neighbor in different PeerGroup

Explanation    Neighbor indicates that it is a different peergroup. This software version does not support multiple peer groups.

Recommended Action    Correct switch address to be part of the same peer group.


Error Message    %PNNI-4-INTERNAL_ERROR: Cannot add NNI interface, uninitialized pointers

Explanation    Neighbor indicates that it is a different peergroup. This software version does not support multiple peer groups.

Recommended Action    Correct switch address to be part of the same peer group.


Error Message    %PNNI-4-INTERNAL_ERROR: Getting Node Id For An Invalid Node [hex], node

Explanation    Neighbor indicates that it is a different peergroup. This software version does not support multiple peer groups.

Recommended Action    Correct switch address to be part of the same peer group.


Error Message    %PNNI-4-INTERNAL_ERROR: Null element to deq_ptse

Explanation    Neighbor indicates that it is a different peergroup. This software version does not support multiple peer groups.

Recommended Action    Correct switch address to be part of the same peer group.


Error Message    %PNNI-4-INTERNAL_ERROR: Can't find our own node in PTSE database

Explanation    Neighbor indicates that it is a different peergroup. This software version does not support multiple peer groups.

Recommended Action    Correct switch address to be part of the same peer group.


Error Message    %PNNI-2-SPF_ERROR: Tent List Overflow in min_aw_route_od()

Explanation    Number of nodes in the network exceeds the node limit of the internal SPF data structure.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-2-SPF_ERROR: Tent List Overflow in min_cdv_route_od()

Explanation    Number of nodes in the network exceeds the node limit of the internal SPF data structure.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-2-SPF_ERROR: Tent List Overflow in min_ctd_route_od()

Explanation    Number of nodes in the network exceeds the node limit of the internal SPF data structure.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-2-SPF_ERROR: Tent List Overflow in min_aw_dijkstra_bg()

Explanation    Number of nodes in the network exceeds the node limit of the internal SPF data structure.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-2-SPF_ERROR: Tent List Overflow in min_cdv_dijkstra_bg()

Explanation    Number of nodes in the network exceeds the node limit of the internal SPF data structure.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-2-SPF_ERROR: Tent List Overflow in min_ctd_dijkstra_bg()

Explanation    Number of nodes in the network exceeds the node limit of the internal SPF data structure.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-2-SPF_ERROR: Tent List Overflow in min_hop_route_all()

Explanation    Number of nodes in the network exceeds the node limit of the internal SPF data structure.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: PDB is NULL on a Route Request!!! [hex], msg->op_code

Explanation    Bad request from signaling process error.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: Unknown timer type [hex]

Explanation    Bad request from signaling process error.

Recommended Action    If this message recurs, contact your technical support representative for assistance.


Error Message    %PNNI-4-INTERNAL_ERROR: IF table full, cannot add new interface [hex]

Explanation    No more entries in the interface table are allowed. The maximum number of entries is 256.

Recommended Action    Do not add anymore entries in the interface table.

SONICT Errors

SONICT driver error messages.


Error Message    %SONICT-1-NOMEMORY: Unit [dec], no memory for [chars] idb structure

Explanation    The unit described has a memory error for the IDB structure.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %SONICT-1-INITFAIL: Unit [dec], initialization timeout failure, csr [dec]=0x%04x

Explanation    The unit described has an initialization timeout failure, cell missequenced ratio.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %SONICT-3-SPURIDON: Unit [dec], spurious IDON interrupt, csr [dec]=0x%04x

Explanation    The unit described has a spurious IDON interrupt, cell missequenced ratio.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %SONICT-3-OWNERR: Unit [dec], buffer ownership error, pak = 0x [hex]

Explanation    The unit described has a buffer ownership error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %SONICT-3-INTERNAL_ERROR: sonic_send: semaphore locked

Explanation    SONIC send error. Semaphore locked.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %SONICT-3-INTERNAL_ERROR: sonic_send: no free tbufs

Explanation    SONIC send error. No free transmit buffers.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %SONICT-3-INTERNAL_ERROR: sonic_send: tp not free

Explanation    SONIC send error. tp not free.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %SONICT-3-INTERNAL_ERROR: sonic_send: PANIC: sonicT is still using this tda

Explanation    SONIC send error. SONICT is still using this tda.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %SONICT-3-INTERNAL_ERROR: sonic_send: TXP did not clear

Explanation    SONIC send error. TXP did not clear.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %SONICT-3-XMIT_ERR: TX Error [hex]

Explanation    Transmit error.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %SONICT-3-INTERNAL_ERROR: sonic ISR: BAD NEWS, got RBE int

Explanation    SONIC ISR error. Got RBE interface.

Recommended Action    If this message occurs, contact your technical support representative for assistance.

T1E1SUNI Error Messages

Asynchronous Transfer Mode error messages


Error Message    %T1E1SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] IDB structure

Explanation    The unit described has a memory error for the IDB structure.

Recommended Action    If this message occurs, contact your technical support representative for assistance.


Error Message    %T1E1SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] ds structure

Explanation    The unit described has a memory error for the ds structure.

Recommended Action    If this message occurs, contact your technical support representative for assistance.

Error Code Index

The following section provides an alphabetical listing of the LightStream 1010 switch error codes followed by the page number where the description is found.


%AAL5-3-INTERNAL_ERROR: AAL5 doesn't handle such large pkts 3

%AAL5-3-INTERNAL_ERROR: aal5send: mmc_queuecell failed 3

%AAL5-3-INTERNAL_ERROR: atm_output: Bad enctype 3

%AAL5-3-INTERNAL_ERROR: No more big aal5 pkts 4

%AAL5-3-INTERNAL_ERROR: Out of reassembly buffers 3

%AAL5-3-RXERR: [hex], orig [hex], port= [chars] 4

%ATM-3-FAILCREATEVC: ATM failed to create VPI=[dec], VCI=[dec]) on Interface [chars], (Cause of the failure: [chars]) 4

%ATM-3-UNSUPPORTED_QOS_PARMAS:ATM failed to create VC on Interface [ATM int],(Cause of the failure Invalid traffic shaping parameters or out of rate queues. 5

%ATM-4-MTUCALLMISMATCH: Incoming call from [ATM NSAP] has a mismatched maximum transmission unit - incoming forward PDU size is [dec], backward PDU size is [dec], interface [chars] MTU size is [dec][chars] 4

%ATM-4-NOMEM: Failed to allocate memory--[chars], ONEMIN 5

%ATMCORE-2-INTERNAL_CRITICAL: atm_rm_show_commands null csb 10

%ATMCORE-2-INTERNAL_CRITICAL: atm_rm_show_commands null csb 9

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmCtt_init: no chunk for Stable CTT 13

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmCtt_init: no chunk for Transient CTT 13

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmCttStableRowAlloc: null request pointer 13

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: Can't get rcv ctt row 8

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: Can't get xmt ctt row 8

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: No atm_swdb 7

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: No ifCB 7

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: No swidb 7

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfDeleted: No swatmdb 8

%ATMCORE-2-INTERNAL_CRITICAL: checkChangePortMetrics: No ifRm 15

%ATMCORE-2-INTERNAL_CRITICAL: createLogIfRm: Duplicate Logical interface 6

%ATMCORE-2-INTERNAL_CRITICAL: createLogIfRm: No atmswdb 6

%ATMCORE-2-INTERNAL_CRITICAL: createLogIfRm: No Physical interface 6

%ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: atm_db is null 6

%ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: atmswdb is null 6

%ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: ifCb is null 7

%ATMCORE-2-INTERNAL_CRITICAL: rmTransientCttRowAct: null request pointer 13

%ATMCORE-2-INTERNAL_CRITICAL: setPhyPortMaxCr: Bad plimtype 6

%ATMCORE-2-INTERNAL_CRITICAL: atm_rm_show_commands null csb 21

%ATMCORE-2-INTERNAL_CRITICAL: atm_rm_show_commands null csb 9

%ATMCORE-2-INTERNAL_CRITICAL: atm_rm_show_commands null csb return 21

%ATMCORE-2-INTERNAL_CRITICAL: atm_rm_show_commands: bad csb show type 9

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rm_if_init: Not ATM if 7

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmCtt_init: no chunk for Stable CTT 21

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmCtt_init: no chunk for Transient CTT 21

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmCttStableRowAlloc: null request pointer 21

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: Can't get rcv ctt row 21

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: Can't get xmt ctt row 21

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: No atm_swdb 21

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: No ifCB 22

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfCreated: No swidb 22

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmLogicalIntfDeleted: No swatmdb 22

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacGetIntfConnRes: Null re/rsp pointer 12

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacGetIntfConnRes: Null req/rsp pointer. 22

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacReduceIntfConnRes: Bad interface. 22

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacReduceIntfConnRes: Bad sc. 22

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacRelIntfConnRes: Bad interface 12

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacRelIntfConnRes: Bad sc 12

%ATMCORE-2-INTERNAL_CRITICAL: atmcore_rmRcacRelIntfConnRes: Null req pointer 12

%ATMCORE-2-INTERNAL_CRITICAL: canAdmitP2mpFlow: Bad flow 18

%ATMCORE-2-INTERNAL_CRITICAL: canAdmitTraffic: Bad sc 18

%ATMCORE-2-INTERNAL_CRITICAL: checkChangePortMetrics: No ifRm. return; 22

%ATMCORE-2-INTERNAL_CRITICAL: createLogIfRm: Duplicate Logical interface. 22

%ATMCORE-2-INTERNAL_CRITICAL: createLogIfRm: No atmswdb. 22

%ATMCORE-2-INTERNAL_CRITICAL: createLogIfRm: No Physical interface. 23

%ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: atm_db is null. 23

%ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: atmswdb is null. 23

%ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: ifCb is null. 23

%ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: ifRm not null 7

%ATMCORE-2-INTERNAL_CRITICAL: createPhyIfRm: swidb is null 7

%ATMCORE-2-INTERNAL_CRITICAL: fetchPhyIfI: Bad port type 19

%ATMCORE-2-INTERNAL_CRITICAL: flowTrafficParmLimitsOk: Bad sc 18

%ATMCORE-2-INTERNAL_CRITICAL: getDefaultPhyIfOutQMaxSize: Bad queue 16

%ATMCORE-2-INTERNAL_CRITICAL: getIfPhyLogRmFromIfcb: Null sw atm ifcb 5

%ATMCORE-2-INTERNAL_CRITICAL: initPhyIfPlatDepRmValues: Bad plim type 16

%ATMCORE-2-INTERNAL_CRITICAL: initPhyIfPlatDepRmValues: Bad queue. 16

%ATMCORE-2-INTERNAL_CRITICAL: ls1010_atmcore_rmGetInputUpcParms: Null input ptrs 20

%ATMCORE-2-INTERNAL_CRITICAL: rm_backgroundChangeIntfConnParm: no ifCB 18

%ATMCORE-2-INTERNAL_CRITICAL: rmCtt_chkDeleteRow: row to delete not found 14

%ATMCORE-2-INTERNAL_CRITICAL: rmInstallInterfaceHardware: Can't install CPU Max q size 16

%ATMCORE-2-INTERNAL_CRITICAL: rmInstallInterfaceHardware: Can't install Max q size 16

%ATMCORE-2-INTERNAL_CRITICAL: rmInstallInterfaceHardware: Missing RM idb pointer 17

%ATMCORE-2-INTERNAL_CRITICAL: rmInstallSwitchHardware: Can't install pri cell limit 17

%ATMCORE-2-INTERNAL_CRITICAL: rmPhyLogIf_2_ifId: Null logical RM cb 5

%ATMCORE-2-INTERNAL_CRITICAL: rmPhyLogIf_2_ifId: Null sw atm ifcb 5

%ATMCORE-2-INTERNAL_CRITICAL: rmPhyLogIf_2_ifId: Null swidb atm cb 5

%ATMCORE-2-INTERNAL_CRITICAL: rmTransientCttRowAct: null request pointer 23

%ATMCORE-2-INTERNAL_CRITICAL: setPhyIfStaticMetrics: Bad port type 16

%ATMCORE-2-INTERNAL_CRITICAL: setPhyPortMaxCr: Bad plimtype. 23

%ATMCORE-2-INTERNAL_CRITICAL: show_if_conn_hw: no ifCB 8

%ATMCORE-2-INTERNAL_CRITICAL: trafficCompleteConsistent: Bad sc 17

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttRowDetach: num Vxs attached <= 0 14

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttStableRowAlloc: Bad parm quals 13

%ATMCORE-3-INTERNAL_ERROR: allocNewStableRow: dup row 12

%ATMCORE-3-INTERNAL_ERROR: allocNewTransientRow: dup row 12

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmCtt_init: Error allocating row 1 13

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttAreFlowsSame: bad sc 14

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttAreFlowsSame: sc different 14

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttRowGet: No SVC row 13

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmGlobalCfg: bad selector 14

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmIfTrParmLimitCfg: bad selector. 15

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfClsFlowCfg: bad selector 15

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQScThreshCfg: bad selector 15

%ATMCORE-3-INTERNAL_ERROR: isFlowPolicyOk: Bad sc 11

%ATMCORE-3-INTERNAL_ERROR: k_atmTrafficDescrParamEntry_set: Bad rowStatus value 16

%ATMCORE-3-INTERNAL_ERROR: processIgnoreRcacReq: bad sc 11

%ATMCORE-3-INTERNAL_ERROR: processIntfListConnResGetReq: Bad IfSelect 11

%ATMCORE-3-INTERNAL_ERROR: accumulateOutputQosMetric: Bad sc 17

%ATMCORE-3-INTERNAL_ERROR: allocFlowEbw: Bad sc 18

%ATMCORE-3-INTERNAL_ERROR: allocNewStableRow: dup row freeRowStruct(row) 23

%ATMCORE-3-INTERNAL_ERROR: allocNewTransientRow: dup row 23

%ATMCORE-3-INTERNAL_ERROR: atm_rm_cfg_commands: bad csb info 10

%ATMCORE-3-INTERNAL_ERROR: atm_rm_cfg_commands: nvgen default: should not happen 9

%ATMCORE-3-INTERNAL_ERROR: atm_rm_int_cfg_commands: bad nvgen selector value 11

%ATMCORE-3-INTERNAL_ERROR: atmcore_collectPnniMetrics: Bad interface. 23

%ATMCORE-3-INTERNAL_ERROR: atmcore_rm_derivePnniMetricCellRates: Bad sc. 24

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmCtt_init: Error allocating row [dec], error [dec] 9

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttAreFlowsSame: bad sc 24

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttAreFlowsSame: sc different. 24

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttRowDetach: num Vxs attached <= 0 24

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmCttRowGet: No SVC row. 24

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmGetDefaultQosObj: bad input traffic 24

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmGetDefaultQosObj: bad input traffic 8

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmGetIntfLineCellRate: No RM control block on interface. 24

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmGlobalCfg: bad selector. 24

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmIfTrParmLimitCfg: bad selector. 24

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmIfTrParmLimitCfg: bad selector.return(RMMGT_CFG_RESULT_BAD_VALUE) 25

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfClsFlowCfg: bad selector. return(RMMGT_CFG_RESULT_BAD_VALUE) 25

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQCfg: bad 25 Mbps port. 25

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQCfg: Couldn't install hw 15

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQScThreshCfg: bad 25 Mbps port. 25

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQScThreshCfg: bad selector 15

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQScThreshCfg: bad selector. 25

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQScThreshCfg: can't install if abr thresh 14

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmPhyIfOutQScThreshCfg: can't install if abr thresh 15

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmRcacAreTrafficParmConsistent: No ctt row 12

%ATMCORE-3-INTERNAL_ERROR: atmcore_rmRcacRelIntfConnRes: Bad interface 12

%ATMCORE-3-INTERNAL_ERROR: cfgCttCommands: can't release not-ready row 9

%ATMCORE-3-INTERNAL_ERROR: chg_phyif_qthresh_req: bad selector 10

%ATMCORE-3-INTERNAL_ERROR: convertIntToExtRowData: Bad sc 19

%ATMCORE-3-INTERNAL_ERROR: convertRowScToSnmpFmt: Bad sc 19

%ATMCORE-3-INTERNAL_ERROR: copyAbrRrThresh: No hwidb 25

%ATMCORE-3-INTERNAL_ERROR: copyAbrRrThresh: No phy intf rm cb 25

%ATMCORE-3-INTERNAL_ERROR: copyClsBwUpdateCrs: No rm cb 25

%ATMCORE-3-INTERNAL_ERROR: copyQMaxSizeParamsChgPortMetrics: No hwidb 25

%ATMCORE-3-INTERNAL_ERROR: copyQMaxSizeParamsChgPortMetrics: No phy intf rm cb 26

%ATMCORE-3-INTERNAL_ERROR: derivePifIM: Bad If type 19

%ATMCORE-3-INTERNAL_ERROR: deriveTrafTypeFromOid: no OID ptr 15

%ATMCORE-3-INTERNAL_ERROR: errString 26

%ATMCORE-3-INTERNAL_ERROR: errStringfreeRowStruct(row) 26

%ATMCORE-3-INTERNAL_ERROR: getIfPhyRmFromIfcb: bad output if cbs 6

%ATMCORE-3-INTERNAL_ERROR: installRmPhyIfClsFlowCfg: bad 25 Mbps port. 26

%ATMCORE-3-INTERNAL_ERROR: isCpuIntf: bad if cbs 6

%ATMCORE-3-INTERNAL_ERROR: isFlowPolicyOk: Bad sc. setNegativeRspCode(ifRm,req,rsp, 26

%ATMCORE-3-INTERNAL_ERROR: isOutputQosOk: Bad sc 11

%ATMCORE-3-INTERNAL_ERROR: k_atmTrafficDescrParamEntry_set: Bad rowStatus value. 26

%ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmConnGetFeatCardTxQThresholds: bad input 20

%ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmConnGetFeatCardTxQThresholds: bad output if cbs 20

%ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmGetInputUpcParms: bit rate too large 20

%ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmGetInputUpcParms: no if log rm cb 20

%ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmGetTransmitOutputQueue: Bad sc 19

%ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmGetTransmitQueueThresh: bad input 20

%ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmGetTransmitQueueThresh: bad output if cbs 20

%ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmInstallIfPacing: Can't install port pacing 19

%ATMCORE-3-INTERNAL_ERROR: ls1010_atmcore_rmIsFeatureCardQHiPri: Bad sc 19

%ATMCORE-3-INTERNAL_ERROR: nvgenCttRow: [dec] stable row, bad sc 5

%ATMCORE-3-INTERNAL_ERROR: nvgenOutputThresh: No hwidb 26

%ATMCORE-3-INTERNAL_ERROR: nvgenParmLimits: bad parm limit selector 10

%ATMCORE-3-INTERNAL_ERROR: nvgenParmLimits: bad parm limit service category 10

%ATMCORE-3-INTERNAL_ERROR: nvgenStartOutputQ: bad queue value 10

%ATMCORE-3-INTERNAL_ERROR: nvgenStartServCatOutQ: bad service category value 10

%ATMCORE-3-INTERNAL_ERROR: nvgenTolerance: bad service category value 10

%ATMCORE-3-INTERNAL_ERROR: outputQosValueOk: Bad MetricAttr 17

%ATMCORE-3-INTERNAL_ERROR: printCttRow: [dec] rowindex, bad sc 9

%ATMCORE-3-INTERNAL_ERROR: processIgnoreRcacReq: bad sc. 26

%ATMCORE-3-INTERNAL_ERROR: processIgnoreRcacReq: more than 1 intf 11

%ATMCORE-3-INTERNAL_ERROR: processIgnoreRcacReq: no intf structure 11

%ATMCORE-3-INTERNAL_ERROR: processIntfListConnResGetReq: Bad IfSelect. 26

%ATMCORE-3-INTERNAL_ERROR: relFlowEbw: Bad sc 18

%ATMCORE-3-INTERNAL_ERROR: rm_backgroundChangeIntfParm: No phy if am cb 18

%ATMCORE-3-INTERNAL_ERROR: rm_changeAllIfAbrRrThresh: Null phy RM cb 14

%ATMCORE-3-INTERNAL_ERROR: rm_changeConnHalfLeg: no CTT row 18

%ATMCORE-3-INTERNAL_ERROR: rm_switchChangeCellPriorityLimit: bad priority. 27

%ATMCORE-3-INTERNAL_ERROR: rm_switchChangeCellPriorityLimit: Couldn't install hw 14

%ATMCORE-3-INTERNAL_ERROR: rmInstallInterfaceHardware: can't install if abr thres. 17

%ATMCORE-3-INTERNAL_ERROR: sameTrafficParms: Bad sc 19

%ATMCORE-3-INTERNAL_ERROR: sc_to_trafficParmSc: bad Service Category 8

%ATMCORE-3-INTERNAL_ERROR: selectTraffic: Bad sc 17

%ATMCORE-3-INTERNAL_ERROR: selectTrafficValue: Bad traffic parm 17

%ATMCORE-3-INTERNAL_ERROR: serviceCategoriesOk: Bad sc 11

%ATMCORE-3-INTERNAL_ERROR: show_atm_int_rm: Cannot find phy if structure 8

%ATMCORE-3-INTERNAL_ERROR: show_atm_int_rm: Cannot find phylog if structure 9

%ATMCORE-3-INTERNAL_ERROR: show_if_conn_hw: no CTT row 8

%ATMCORE-3-INTERNAL_ERROR: str 27

%ATMCORE-3-INTERNAL_ERROR: trafficIsCompCon: bad sc 13

%ATMSIG-3-ATMSIG_PRTY_DELETE_FAILED: svc->svc_namestring, svc->vpci, svc->vci, (svc->callRef & ATMSIG_CALLREF_VALUEMASK), (party ? party->endpointRef 27

%ATMSIG-3-ATMSIG_PRTY_INSERT_FAILED ,partnerSvc->svc_namestring, partnerSvc->vpci, partnerSvc->vci, (partnerSvc->callRef & ATMSIG_CALLREF_VALUEMASK), (partnerParty ? partnerParty->endpointRef 27

%ATMSIG-3-ATMSIG_PRTY_INSERT_FAILED: svc->svc_namestring, svc->vpci, svc->vci, (svc->callRef & ATMSIG_CALLREF_VALUEMASK), (svc->curr_party ? svc->curr_party->endpointRef 27

%ATMSIG-3-ATMSIG_SVC_INSERT_FAILED: destSvc->svc_namestring, destSvc->vpci, destSvc->vci, (destSvc->callRef & ATMSIG_CALLREF_VALUEMASK), (destSvc->rootParty ? destSvc->rootParty->endpointRef : 0), destSvc) 27

%ATMSIG-3-ATMSIG_SVC_INSERT_FAILED: svc->svc_namestring, svc->vpci, svc->vci, (svc->callRef & ATMSIG_CALLREF_VALUEMASK), (svc->curr_party ? svc->curr_party->endpointRef : 0), svc);
errmsg(&msgsym(UNEXPECTEDEVENT,SCHED) 27

%ATMSIG-3-ENQFAIL: enqueue acctGlob.mymsg_inqueue free(msg) errmsg(&msgsym(UNEXPECTEDEVENT,SCHED) 28

%ATMSIG-3-ENQFAIL: enqueue atmsig_cb.mgmtapi_inqueue errmsg(&msgsym(UNEXPECTEDEVENT, SCHED) 28

%ATMSIG-3-ENQFAIL: enqueue atmsig_cb.mgmtapi_inqueue free(msg) 28

%ATMSIG-3-ENQFAIL: enqueue atmsig_cb.mgmtapi_inqueue msg->err_code = ATMSIG_MGMT_API_INTERNAL_ERROR 28

%ATMSIG-3-ENQFAIL: enqueue atmsig_cb.pnni_queue atm_ ys_msg->ret_code = IPC_ASYNC 28

%ATMSIG-3-ENQFAIL: enqueue atmSig_outputQ 28

%ATMSIG-3-FAILASSERT: [chars] 31

%ATMSIG-3-FAILHALFLEGREM: 2nd halfleg failed, Get 2nd half leg failure. no ifcb 31

%ATMSIG-3-FAILHALFLEGREM: halfLeg removal failed, removeHalfLeg 31

%ATMSIG-3-FAILXCONN: xconn fail 28

%ATMSIG-3-INVPNNIMSG : 29

%ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: dest proc not valid 30

%ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: msg code not resp 30

%ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: msg type not valid 30

%ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: msg vers bad 30

%ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: NULL curr party 30

%ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: NULL message 30

%ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: NULL port list 30

%ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: NULL port_rsp message 31

%ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: NULL SVC 30

%ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: number of ports > MAX 29

%ATMSIG-3-INVPNNIMSG: Invalid msg from routing/pnni: source proc not valid 30

%ATMSIG-3-NOMEM: [chars] 31

%ATMSIG-3-NOSVC: no SVC, atmSig_findPartyBlockByRef 31

%ATMSIG-3-NOSVC: no SVC, atmSig_input 31

%CI-3-BLOWER: Fan failure 32

%CI-3-NOFORK: Couldn't start environment polling daemon 32

%CI-3-PSFAIL: Power supply [dec] failure 33

%CI-3-PSOK: Power supply [dec] OK 33

%CI-3-PSTYPE:"***WARNING*** Incompatible power supply types -
One is AC, other is DC. 32

%CI-3-SHUTDOWN: Shutting down due to overheat. 32

%CI-3-TEMP: Temperature overheat 32

%CI-6-BLOWEROK: Fan OK 32

%CI-6-PSCHANGE: Power supply [dec] changed from [chars] [chars] to [chars] 33

%CI-6-PSFANOK: Power supply fan [dec] OK 32

%CI-6-TEMPOK: Temperature OK 32

%DCU-1-NOMEMORY: [chars]: DCU keep-alive failure, card reset 33

%DCU-1-NOMEMORY: cardDatabaseArray, crashdump (0) 33

%DCU-1-NOMEMORY: Unit [dec], atm_db 33

%DCU-1-NOMEMORY: Unit [dec], IDB subblock 33

%DCU-1-NOMEMORY: Unit [dec], no memory for [chars] ds structure 34

%DCU-1-NOMEMORY: Unit [dec], no memory for [chars] IDB structure 34

%DCU-1-NOMEMORY: Unit [dec], port database 33

%DS3E3SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] ds structure 34

%DS3E3SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] IDB structure 34

%FPGA-3-ABR: ABR FPGA don't reset properly, Control Register=%x 41

%FPGA-3-DONE_PIN: Done pin or Status pin isn't pull low, FPGA# [dec] 41

%FPGA-3-DOWNLOAD: Download Fail, FPGA# [dec] 41

%FPGA-3-MCAST: Multicast FPGA don't reset properly, Control Register=%x 41

%FPGA-3-NOFORK: Feature Card version invalid/old. Feature Card Version:[dec].[dec], ASP Version:[dec].[dec] 42

%FPGA-3-STATUS_PIN: Error in status pin, FPGA# [dec] 42

%FPGA-3-TRAFF: Traffic FPGA don't reset properly, Control Register=%x 42

%FPGA-3-TYPE: ***WARNING*** Invalid feature card type - use higher version of software: [hex] 42

%LINK-3-TOOBIG: Interface [chars] Output packet size of [dec] bytes too big 42

%OC12SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] ds structure 43

%OC12SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] IDB structure 43

%OC3SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] ds structure 43

%OC3SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] IDB structure 43

%OIR-3-LONGSTALL: Long bus stall ([dec] [chars]), the new PAM may not seated properly. Please remove it and try again. 44

%OIR-3-SHUTDOWN: Shutting down due to overheat 43

%OIR-6-INSCARD: Card inserted in slot [dec], subcard [dec], interfaces administratively shutdown 43

%OIR-6-REMCARD: Card removed from slot [dec], subcard [dec], interfaces disabled 43

%PNNI-2-NO_INTERNAL_NUMBER: 44

%PNNI-2-SPF_ERROR: Tent List Overflow in min_aw_dijkstra_bg() 54

%PNNI-2-SPF_ERROR: Tent List Overflow in min_aw_route_od() 54

%PNNI-2-SPF_ERROR: Tent List Overflow in min_cdv_dijkstra_bg() 54

%PNNI-2-SPF_ERROR: Tent List Overflow in min_cdv_route_od() 54

%PNNI-2-SPF_ERROR: Tent List Overflow in min_ctd_dijkstra_bg() 54

%PNNI-2-SPF_ERROR: Tent List Overflow in min_ctd_route_od() 54

%PNNI-2-SPF_ERROR: Tent List Overflow in min_hop_route_all() 54

%PNNI-3-INTERNAL_ERROR : Can't find node included in ACK header: pnni_nodeid_string(node_id) 44

%PNNI-3-INTERNAL_ERROR: Can't find node included in ACK header: , *pnni_nodeid_string(node_id) 44

%PNNI-3-INTERNAL_ERROR: Attempt to add a PTSE but Node doesn't exist pnni_nodeid_string(node_id), ptse_id 45

%PNNI-3-INTERNAL_ERROR: Can't find our own node in PTSE database 45

%PNNI-3-INTERNAL_ERROR: Cannot add NNI interface port 45

%PNNI-3-INTERNAL_ERROR: Cannot add NNI interface, uninitialized pointers ios_idb 45

%PNNI-3-INTERNAL_ERROR: Cannot locate neighbor to be deleted 45

%PNNI-3-INTERNAL_ERROR: Cannot relocate PTSE component 44

%PNNI-3-INTERNAL_ERROR: Duplicate node , pnni_nodeid_string(node_id) 46

%PNNI-3-INTERNAL_ERROR: Duplicate PTSE of, pnni_nodeid_string(node_id), ptse_id) 46

%PNNI-3-INTERNAL_ERROR: failed to get the argument to pnni_hello process, pid = , pdb->pid 44

%PNNI-3-INTERNAL_ERROR: Getting Node Id For An Invalid Node, , node) 46

%PNNI-3-INTERNAL_ERROR: Hello state machine error in state error_msg, pnni_idb->port_id 44

%PNNI-3-INTERNAL_ERROR: IF table full, cannot add new interface port 45

%PNNI-3-INTERNAL_ERROR: IISP failed to get, the argument to iisp_router process, pid = , pdb->pid) 46

%PNNI-3-INTERNAL_ERROR: Internal Nbr Number Stack Overflow 46

%PNNI-3-INTERNAL_ERROR: Null element to deq_ptse 46

%PNNI-3-INTERNAL_ERROR: NULL node in ptsedb ID, , ptsedb->ptse_data->ptse_id) 46

%PNNI-3-INTERNAL_ERROR: Out Of Parse Buffers 46

%PNNI-3-INTERNAL_ERROR: PNNI relocation of addr failed, could not find pfx 45

%PNNI-3-INTERNAL_ERROR: PNNI: Service orig timer, but PTSE is NULL!!!, , ptsedb) 47

%PNNI-3-INTERNAL_ERROR: Rcv DS in an invalid nbr state 47

%PNNI-3-INTERNAL_ERROR: Received API message to create an interface for an existing port,, port) 47

%PNNI-3-INTERNAL_ERROR: Remove neighbor with interface list not empty 47

%PNNI-3-INTERNAL_ERROR: removing our own PTSE ID 1, \nplse collect \show atm pnni trace buf, ptse) 47

%PNNI-3-INTERNAL_ERROR: retbuffer(pak) 45

%PNNI-3-INTERNAL_ERROR: rxmt timer with no element. 47

%PNNI-3-INTERNAL_ERROR: Unknown timer type, expired_timer 45

%PNNI-3-INTERNAL_ERROR: Unrecognized req msg from signaling, , msg->op_code 47

%PNNI-4-ADDRESS_EXIST: Address derived from the switch's prefix by soft PVC manager [chars] clashes with existing address in prefix table 50

%PNNI-4-ATM_SYS_ERROR: Error: Received Unrecognized API message 50

%PNNI-4-ATM_SYS_ERROR: Error: Incorrect API version. Mismatched API message version received by PNNI 50

%PNNI-4-BADPACKET: Invalid ACK pkt: [chars] 52

%PNNI-4-BADPACKET: Invalid DS pkt: Bad length in node [chars], eDS PTSE sum len [dec], left [dec], count [dec], left [dec] 51

%PNNI-4-BADPACKET: Invalid DS pkt: Length in hdr shorter than smallest possible, len [dec], ds_data->length 51

%PNNI-4-BADPACKET: Invalid DS pkt: Type in header is not Nodal PTSE summaries (512), type [dec] 51

%PNNI-4-BADPACKET: Invalid pkt: length shorter than header size [dec], phdr->length 48

%PNNI-4-BADPACKET: Invalid PTSP pkt: Unknown type in PTSE header: [dec],) 52

%PNNI-4-BADPACKET: Invalid PTSP pkt: [chars] 53

%PNNI-4-BADPACKET: Invalid PTSP pkt: Bad checksum in PTSE ID: [dec] 53

%PNNI-4-BADPACKET: Invalid PTSP pkt: Bad Type in PTSE header: [dec] 52

%PNNI-4-BADPACKET: Invalid PTSP pkt: IG with type matching the PTSE type is missing: from PTSE [dec] [dec] 53

%PNNI-4-BADPACKET: Invalid PTSP pkt: Inconsistent type between PTSE header and: PTSE content [dec] [dec] 52

%PNNI-4-BADPACKET: Invalid PTSP pkt: PTSE len does not add up to total PTSE len in header [dec] [dec] 52

%PNNI-4-BADPACKET: Invalid REQ pkt: [chars] [dec] [dec] 51

%PNNI-4-BADPACKET: Hello, len_err_str, ((pnni_ptse_hdr_t *)hello)->ptse_type, TLV_LEN(hello) 48

%PNNI-4-BADPACKET: Invalid pkt: unrecognized packet type [dec], TLV_TYPE( phdr ) 48

%PNNI-4-BADPACKET: Nodal REQ, Contains Unknown Mandatory IG, req_hdr, req_hdr->type 48

%PNNI-4-BADPACKET: PTSE ACK, Has No Nodal PTSE Acks, ack_pkt->type, TLV_LEN((pnni_tlv_t *)ack_pkt)) 48

%PNNI-4-BADPACKET: PTSE ACK, Has No Nodal PTSE Acks, pnni->type, TLV_LEN((pnni_tlv_t *)pnni)) 48

%PNNI-4-BADPACKET: PTSE ACK, len_err_str, ((pnni_ptse_hdr_t *)ptse_ack)->ptse_type, TLV_LEN(ack)) 48

%PNNI-4-BADPACKET: PTSE len_err_str, ((pnni_ptse_hdr_t *)ptse)->ptse_type, TLV_LEN((pnni_tlv_t *)ptse)) 48

%PNNI-4-BADPACKET: PTSP, Has Unknown Mandatory IG At Top Level, ptsp, ptsp->type 49

%PNNI-4-BADPACKET: REQ Contains Unknown Mandatory IG At Top Level req_pkt, req_pkt->type 49

%PNNI-4-BADPACKET: REQ error_msg, 0, 0); } req_hdr = pnni_get_next_tlv((pnni_tlv_t)pnni, (pnni_tlv_t)req_hdr 49

%PNNI-4-BADPACKET: REQ, len_err_str, ((pnnihdr_t *)req)->type, TLV_LEN(req)) 49

%PNNI-4-BADROUTEREQ: msg->op_code ) 49

%PNNI-4-CONFIG_ERROR: Configuration Error: Port looped-back, cannot form adjacency 52

%PNNI-4-CONFIG_ERROR: Configuration Error: Neighbor in different PeerGroup 53

%PNNI-4-CONFIG_ERROR: Missing PNNI VC on NNI interface. 49

%PNNI-4-CONFIG_ERROR: Neighbor in different PeerGroup 49

%PNNI-4-CONFIG_ERROR: Port looped-back, cannot form adjacency 49

%PNNI-4-INTERNAL_ERROR: Cannot add NNI interface. An attempt to add an NNI interface failed 50

%PNNI-4-INTERNAL_ERROR: Can't find our own node in PTSE database 54

%PNNI-4-INTERNAL_ERROR: Getting Node Id For An Invalid Node [hex], node 53

%PNNI-4-INTERNAL_ERROR: IF table full, cannot add new interface [hex] 55

%PNNI-4-INTERNAL_ERROR: IISP failed to get the argument to iisp_router process 47

%PNNI-4-INTERNAL_ERROR: Null element to deq_ptse 54

%PNNI-4-INTERNAL_ERROR: PDB is NULL on a Route Request!!! [hex], msg->op_code 55

%PNNI-4-INTERNAL_ERROR: PNNI failed to set the argument to pnni_router process 50

%PNNI-4-INTERNAL_ERROR: PNNI failed to set the argument to pnni_update process 50

%PNNI-4-INTERNAL_ERROR: Received API message to create an interface for an existing port 50

%PNNI-4-INTERNAL_ERROR: rxmt timer with no element 52

%PNNI-4-INTERNAL_ERROR: Can't find node included in ACK header: [chars] , pnni_nodeid_string(node_id) 53

%PNNI-4-INTERNAL_ERROR: Cannot add NNI interface, uninitialized pointers 53

%PNNI-4-INTERNAL_ERROR: Cannot locate neighbor to be deleted 51

%PNNI-4-INTERNAL_ERROR: Hello state machine error in state [chars] , error_msg 53

%PNNI-4-INTERNAL_ERROR: Internal Nbr Number Stack Overflow 52

%PNNI-4-INTERNAL_ERROR: NULL node in ptsedb ID [hex] 51

%PNNI-4-INTERNAL_ERROR: Remove neighbor with interface list not empty 51

%PNNI-4-INTERNAL_ERROR: Rev DS in an invalid nbr state 51

%PNNI-4-INTERNAL_ERROR: Unknown timer type [hex] 55

%PNNI-4-INTERNAL_ERROR: Unrecognized req msg from signaling [hex] 51

%PNNI-4-INTERNAL_ERROR:Received API message to delete an interface that PNNI does not know of 50

%RSP-2-NOMEMORY: No memory available for OIR process 42

%RSP-3-IDPROM: Bad or missing ID EEPROM, controller type [dec] 42

%SONICT-1-INITFAIL: Unit [dec], initialization timeout failure, csr [dec]=0x%04x 55

%SONICT-1-NOMEMORY: Unit [dec], no memory for [chars] idb structure 55

%SONICT-3-INTERNAL_ERROR: sonic ISR: BAD NEWS, got RBE int 56

%SONICT-3-INTERNAL_ERROR: sonic_send: no free tbufs 56

%SONICT-3-INTERNAL_ERROR: sonic_send: PANIC: sonicT is still using this tda 56

%SONICT-3-INTERNAL_ERROR: sonic_send: semaphore locked 55

%SONICT-3-INTERNAL_ERROR: sonic_send: tp not free 56

%SONICT-3-INTERNAL_ERROR: sonic_send: TXP did not clear 56

%SONICT-3-OWNERR: Unit [dec], buffer ownership error, pak = 0x [hex] 55

%SONICT-3-SPURIDON: Unit [dec], spurious IDON interrupt, csr [dec]=0x%04x 55

%SONICT-3-XMIT_ERR: TX Error [hex] 56

%T1E1SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] ds structure 56

%T1E1SUNI-1-NOMEMORY: Unit [dec], no memory for [chars] IDB structure 56


hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1997 © Cisco Systems Inc.