cc/td/doc/product/atm/ls1010s/wa5/12
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Carrier Module and
Port Adapter Specifications

Carrier Module and
Port Adapter Specifications

This appendix contains the following carrier module and port adapter specifications:

System Specifications

The ATM switch carrier module and port adapter specifications are described in Table A-1.


Table A-1: System Specifications
Description Specifications

Dimensions (H x W x D)

Carrier module: 1.2 x 14.4 x 16" (3.0 x 36.6 x 40.6 cm)

Port adapter: 1.2 x 6.5 x 10" (3.0 x 16.5 x 25.4 cm)

Weight

Carrier module: 3.55 lb (1.60 kg)

Port adapter (approximately): 1.10 lb (0.50 kg)

DC voltages supplied and steady-state maximum current ratings

+5V1 @ 70A2

+12V @ 2A

+24V @ 0.2A

Operating temperature

32 to104ºF (0 to 40ºC)

Nonoperating temperature

-40 to 167ºF (-40 to 75ºC)

Humidity

10 to 90%, noncondensing

Altitude

-500 to 10,000 ft (-52 to 3,048 m)

Interface timing

Loop timing, Stratum 4 accuracy clock for self-timing; synchronous, SRTS3, or adaptive clocking for CBR4 traffic

Carrier module

Carrier module for 2-port adapters with slot covers for empty slots installed (WATM-CAM-2P=)

Dimensions (H x W x D)

Carrier module: 1.2 x 14.4 x 16" (3.0 x 36.6 x 40.6 cm)

Port adapter: 1.2 x 6.5 x 10" (3.0 x 16.5 x 25.4 cm)

1V = volts.
2A = amperes.
3SRTS = Synchronous Residual Time Stamp.
4CBR = constant bit rate.

Port Adapter Specifications and Part Numbers

Port adapter specifications, including number of ports, connector types, and part numbers are listed in Table A-2.


Table A-2: Port Adapter Specifications and Part Numbers
Port Adapter Number and
Type of Ports
Connectors Part Number

155-Mbps port adapter

4 SONET STS-3c/SDH STM-1 multimode fiber ports

SC connectors

WAI-OC-3-4MM

4 SONET STS-c/SDH STM-1 single-mode fiber ports1

SC connectors

WAI-OC-3-4SM

4 SONET STS-3c/SDH ST-1:
1 single-mode,
3 multimode fiber ports

SC connectors

WAI-OC3-1S3M

4 SONET ST-3c/SDH ST-1 UTP-5 ports

RJ-45 connectors

WAI-C3-4U5

622-Mbps port adapter

1 SONET ST-12c/SDH STM-4c single-mode fiber port2

SC connector

WAI-OC12-1SM

1 SONET STS-12c/SDH STM-4c multimode fiber port

SC connector

WAI-OC12-1MM

DS3 and E3 port adapters

2 DS3 ports

BNC connectors

WAI-T3-2BNC

4 DS3 ports

BNC connectors

WAI-T3-4BNC

2 E3 ports

BNC connectors

WAI-E3-2BNC

4 E3 ports

BNC connectors

WAI-E3-4BNC

25-Mbps port adapter

12 25-Mbps ports

RJ-45 connectors

WAI-ATM25-12P

T1 and E1 port adapters

4 E1 trunk ports

RJ-48 connectors

WAI-E1-4RJ48

4 T1 trunk ports

RJ-48 connectors

WAI-T1-4RJ48

4 E1 trunk ports

BNC connectors

WAI-E1-4BNC

CES T1 and E1 port adapters

4 E1 CES ports

BNC connectors

WAI-E1C-4BNC

4 E1 CES ports

RJ-48 connectors

WAI-E1C-4RJ48

4 T1 CES ports

RJ-48 connectors

WAI-T1C-4RJ48

CE1 Frame Relay
port adapter

4 CE1 ports

RJ-48c connectors

C85MS-4E1-FRRJ48

4 CE1 ports (spare)

RJ-48c connectors

C85MS-4E1-FRRJ48=

1Available in intermediate- and long-reach fiber.
2Available in intermediate- and long-reach fiber.

Maximum Station-to-Station Cabling Distances

Maximum station-to-station cabling distances and cable types are listed for each port adapter in Table A-3.


Table A-3: Maximum Station-to-Station Cabling Distances
Port Adapter Cable Cabling Distance

DS3

Coaxial cable

450 ft (137 m)

E3

Coaxial cable

450 ft (137 m)

OC-3

UTP1 cable

328 ft (100 m)

OC-3 and OC-12

9/125 micron single-mode fiber

9 miles (15 km)

OC-3 and OC-12

9/125 micron single-mode long-reach fiber

18 miles (30 km)

OC-3

50/125-micron and 62.5/125-micron multimode fiber

1.24 miles (2 km)

OC-12

50/125-micron and 62.5/125-micron multimode fiber

1640 ft (500 m)

T1

UTP cable

650 ft (198 m)

E1

UTP cable

650 ft (198 m)

E1

Coaxial cable

650 ft (198 m)

CE1 Frame Relay

Category 5 twisted-pair

650 ft (198 m)

CES T1

Twisted-pair and STP2

820 ft (248.5 m)
(5.5 dB attenuation at 772 kHz), 100-ohm, 24 AWG3, UTP cable with RJ4-48C connectors

CES E1

Twisted-pair and STP

820 ft (248.5 m)
(5.5 dB attenuation at 772 kHz), 100-ohm, 24 AWG, UTP cable with RJ-48C connectors

CES E1

Coaxial cable

650 ft (198 m)

25-Mbps

UTP cable

328 ft (100 m) with four or fewer separate cable segments on the path

1UTP = unshielded twisted-pair.
2STP = shielded twisted-pair.
3AWG = American Wire Gauge.
4RJ = Registered Jack.

Fiber-Optic Power Levels

Fiber-optic power levels are listed for each port adapter in Table A-4.


Table A-4: Fiber-Optic Power Levels
Port Output Center Wavelength Transmit Receive

OC-3 single mode

1261 to 1360 nm1

Minimum: -15.0 dBm2

Maximum: -8.0 dBm

Minimum: -28.0 dBm

Maximum: -8.0 dBm

OC-3 Single-Mode Long Reach

1281 to 1380 nm

Minimum: -5.0 dBm

Maximum: 0.0 dBm

Minimum: -34.0 dBm

Maximum: -10.0 dBm

OC-3 Multimode

1270 to 1380 nm

Minimum: -20.0 dBm

Maximum: -14.0 dBm

Minimum: -30.0 dBm

Maximum: -14.0 dBm

OC-12 Single-Mode Extended Reach

1274 to 1356 nm

Minimum: -15.0 dBm

Maximum: -8.0 dBm

Minimum: -28.0 dBm

Maximum: -8.0 dBm

OC-12 Multimode

1270 to 1380 nm

Minimum: -20.0 dBm

Maximum: -14.0 dBm

Minimum: -26.0 dBm

Maximum: -14.0 dBm

OC-12 Single-Mode Long Reach

1280 to 1335 nm

Minimum: -3.0 dBm

Maximum: 2.0 dBm

Minimum: -28.0 dBm

Maximum: -8.0 dBm

1nm = nanometers.
2dBm = decibel milliwatt.

Standards Compliance

Catalyst 8540/8510/5500 and LightStream 1010 port adapters, when installed in a system, comply with the standards listed in Table A-5.


Table A-5: Standards Compliance
Specification Standard Description

Compliance

CE Marking

Cisco Systems

Safety

UL 1950 (U.S.)

Underwriters Laboratory

CSA 950 (Canada)

Canadian Standards Association

EN 60950 (European Union)

European Norm.

TUV GS (Germany)

German Test Agency

IEC 950 (International)

International Electrotechnical Commission

AS/NZS 3260 (Australia/New Zealand)

Australia/New Zealand Standards

Electromagnetic Interference (EMI)

FCC Part 15 (CFR 47) Class A

Federal Communications Commission

EN55022
Class A with UTP and
Class B with shielded cables (European Union)

European Norm.

VCCI
Class A with UTP and
Class B with shielded cables (Japan)

Voluntary Control Council for Interference

AS/NZS 3548
Class A with UTP and
Class B with shielded cables

Australia/New Zealand Standards

CISPR 22
Class A with UTP and
Class B with shielded cables (International)

Comite International Special Des Perturbations Radioelectriques


hometocprevnextglossaryfeedbacksearchhelp
Posted: Mon Mar 22 11:31:49 PST 1999
Copyright 1989-1999©Cisco Systems Inc.