The commands shown in this chapter apply to the Catalyst 8540 MSR, Catalyst 8510 MSR, and LightStream 1010 ATM switch routers. Where an entire command or certain attributes of a command have values specific to a particular switch or switch router, an exception is indicated by the following callouts:
![]() |
Note Commands that are identical to those documented in the Cisco IOS software documentation have been removed from this chapter. |
![]() |
Note Commands that no longer function as expected in ATM environments have also been removed from this chapter. |
Refer to Appendix D of this command reference for a detailed list of commands that have been removed, changed or replaced.
To filter ATM signalling call failure based on the outgoing interface rejected call, use the outgoing-port ATM signalling diagnostics configuration command. To return the outgoing port to the default, use the no form of this command.
outgoing-port [atm card/subcard/port]
Syntax Description
card/subcard/port Specifies the card, subcard, and port of the ATM interface. The card number is displayed using the show interfaces command.The subcard number can be either 0 or 1.
Defaults
0
Command Modes
ATM signalling diagnostics configuration
Command History
11.2(8.0.1) New command
Release
Modification
Usage Guidelines
The default 0 means the incoming interface is not considered during filtering.
Examples
The following example shows the outgoing-port command.
Switch# configure terminal Switch(config)# outgoing-port ATM 0/1/1
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed Sep 6 15:51:28 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.