This appendix contains the following carrier module, port adapter, and interface module specifications:
The ATM switch carrier module, port adapter, and interface module specifications are described in Table A-1.
| Description | Specifications |
|---|---|
Dimensions (H x W x D) | Carrier module: 1.2 x 14.4 x 16" (3.0 x 36.6 x 40.6 cm) Port adapter: 1.2 x 6.5 x 10" (3.0 x 16.5 x 25.4 cm) Interface Module: 1.2 x 14.4 x 16" (3.0 x 36.6 x 40.6 cm) |
Weight | Carrier module: 3.55 lb (1.60 kg) Port adapter (approximately): 1.10 lb (0.50 kg) Interface Module: 3.55 lb (1.60 kg) |
DC voltages supplied and steady-state maximum current ratings |
+12V @ 2A +24V @ 0.2A |
32 to104ºF (0 to 40ºC) | |
-40 to 167ºF (-40 to 75ºC) | |
10 to 90%, noncondensing | |
Altitude | -500 to 10,000 ft (-52 to 3048 m) |
Interface timing | Loop timing, Stratum 4 accuracy clock for self-timing; synchronous, SRTS3, or adaptive clocking for CBR4 traffic |
| 1V = volts. 2A = amperes. 3SRTS = Synchronous Residual Time Stamp. 4CBR = constant bit rate. |
Port adapter and interface module specifications, including number of ports, connector types, and part numbers are listed in Table A-2.
| Port Adapter and Interface Module | Number and Type of Ports | Connectors | Part Number |
|---|---|---|---|
25-Mbps port adapter | 12 25-Mbps ports | RJ-45 connectors | WAI-ATM25-12P |
155-Mbps port adapter | 4 SONET STS-3c/SDH STM-1 multimode fiber ports | SC connectors | WAI-OC-3-4MM |
SC connectors | WAI-OC-3-4SM | ||
4 SONET STS-3c/SDH STM-1: | SC connectors | WAI-OC3-1S3M | |
4 SONET STS-3c/SDH STM-1 UTP-5 ports | RJ-45 connectors | WAI-C3-4U5 | |
16-Port OC-3c interface module | 16 SONET STS-3C/SDH | MT-RJ connectors | C85MS-16F-OC3MM |
622-Mbps port adapter | 1 SONET STS-12c/SDH STM-4c single-mode fiber port1 | SC connector | WAI-OC12-1SM |
1 SONET STS-12c/SDH STM-4c multimode fiber port | SC connector | WAI-OC12-1MM | |
4-Port OC-12c interface module | 4 SONET STS-12c/SDH STM-4c single-mode fiber port | Dual SC connectors | C85MS-4F-OC12SS |
4 SONET STS-12c/SDH STM-4c multimode fiber port | Dual SC connectors | C85MS-4F-OC12MM | |
T1 and E1 port adapters | 4 E1 trunk ports | RJ-48 connectors | WAI-E1-4RJ48 |
4 T1 trunk ports | RJ-48 connectors | WAI-T1-4RJ48 | |
4 E1 trunk ports | BNC connectors | WAI-E1-4BNC | |
CE1 Frame Relay | 4 CE1 ports | RJ-48c connectors | C85MS-4E1-FRRJ48 |
4 CE1 ports (spare) | RJ-48c connectors | C85MS-4E1-FRRJ48= | |
CES T1 and E1 port adapters | 4 E1 CES ports | BNC connectors | WAI-E1C-4BNC |
4 E1 CES ports | RJ-48 connectors | WAI-E1C-4RJ48 | |
4 T1 CES ports | RJ-48 connectors | WAI-T1C-4RJ48 | |
DS3 and E3 port adapters | 2 DS3 ports | WAI-T3-2BNC | |
4 DS3 ports | BNC connectors | WAI-T3-4BNC | |
2 E3 ports | BNC connectors | WAI-E3-2BNC | |
4 E3 ports | BNC connectors | WAI-E3-4BNC | |
CDS3 port adapter | 1 DS3 frame relay port | BNC connectors | C85MS-1DS3-FRBNC |
1 DS3 frame relay port (spare) | BNC connectors | C85MS-1DS3-FRBNC= |
| 1Available in intermediate- and long-reach fiber. |
Maximum station-to-station cabling distances and cable types are listed for each port adapter and interface module in Table A-3.
| Port Adapter and Interface Module | Cable | Cabling Distance |
|---|---|---|
25-Mbps | UTP cable | 328 ft (100 m) with four or fewer separate cable segments on the path |
OC-3c | UTP1 cable | 328 ft (100 m) |
OC-3c and OC-12c | 9/125 micron single-mode fiber | 9 miles (15 km) |
OC-3c and OC-12c | 9/125 micron single-mode long-reach fiber | 18 miles (30 km) |
OC-3c | 50/125-micron and 62.5/125-micron multimode fiber | 1.24 miles (2 km) |
OC-12c | 50/125-micron and 62.5/125-micron multimode fiber | 1640 ft (500 m) |
T1 | UTP cable | 650 ft (198 m) |
E1 | UTP cable | 650 ft (198 m) |
E1 | Coaxial cable | 650 ft (198 m) |
CE1 Frame Relay | Category 5 twisted-pair | 650 ft (198 m) |
CES T1 | Twisted-pair and FTP2 | 820 ft (248.5 m) |
CES E1 | Twisted-pair and FTP | 820 ft (248.5 m) |
CES E1 | Coaxial cable | 650 ft (198 m) |
DS3 | Coaxial cable | 450 ft (137 m) |
E3 | Coaxial cable | 450 ft (137 m) |
| 1UTP = unshielded twisted-pair. 2FTP = foil twisted-pair. 3AWG = American Wire Gauge. 4RJ = Registered Jack. |
Fiber-optic power levels are listed for each port adapter and interface module in Table A-4.
| Port | Output Center Wavelength | Transmit | Receive |
|---|---|---|---|
OC-3c Single Mode | 1261 to 1360 nm1 | Minimum: -15.0 dBm2 Maximum: -8.0 dBm | Minimum: -28.0 dBm Maximum: -8.0 dBm |
OC-3c Single-Mode | 1281 to 1380 nm | Minimum: -5.0 dBm Maximum: 0.0 dBm | Minimum: -34.0 dBm Maximum: -10.0 dBm |
OC-3c Multimode | 1270 to 1380 nm | Minimum: -20.0 dBm Maximum: -14.0 dBm | Minimum: -30.0 dBm Maximum: -14.0 dBm |
OC-12c Single-Mode Intermediate Reach | 1293 to 1334 nm | Minimum: -15.0 dBm Maximum: -8.0 dBm | Minimum: -28.0 dBm Maximum: -3.0 dBm |
OC-12c Single-Mode | 1274 to 1356 nm | Minimum: -15.0 dBm Maximum: -8.0 dBm | Minimum: -28.0 dBm Maximum: -8.0 dBm |
OC-12c Multimode | 1270 to 1380 nm | Minimum: -20.0 dBm Maximum: -14.0 dBm | Minimum: -26.0 dBm Maximum: -14.0 dBm |
OC-12c Single-Mode | 1280 to 1335 nm | Minimum: -3.0 dBm Maximum: 2.0 dBm | Minimum: -28.0 dBm Maximum: -8.0 dBm |
| 1nm = nanometers. 2dBm = decibel milliwatt. |
Catalyst 8540 MSR, Catalyst 8510 MSR, Catalyst 5500, and LightStream 1010 port adapters and interface modules, when installed in a system, comply with the standards listed in Table A-5.
| Specification | Standard | Description |
|---|---|---|
Compliance | CE Marking | Cisco Systems |
Safety | UL 1950 (U.S.) | Underwriters Laboratory |
CSA 950 (Canada) | Canadian Standards Association | |
EN 60950 (European Union) | European Norm. | |
TUV GS (Germany) | German Test Agency | |
IEC 950 (International) | International Electrotechnical Commission | |
AS/NZS 3260 (Australia/New Zealand) | Australia/New Zealand Standards | |
Electromagnetic Interference (EMI) | FCC Part 15 (CFR 47) Class A | Federal Communications Commission |
EN55022 | European Norm. | |
VCCI | Voluntary Control Council for Interference | |
AS/NZS 3548 | Australia/New Zealand Standards | |
CISPR 22 | Comite International Special Des Perturbations Radioelectriques |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Thu May 6 13:51:59 PDT 1999