The chassis and power supply specifications are described in Table B-1.
| Description | Specifications |
|---|---|
Dimensions (H x W x D) | 10.4 x 17.25 x 18.4 in. (26.4 x 43.1 x 46.0 cm) |
Weight | Chassis only: 32 lb (13.6 kg) |
Airflow | 95 cfm1 through the system fan assembly |
Operating temperature | 32 to 104ºF (0 to 40ºC) |
Nonoperating temperature | -40 to 167ºF (-40 to 75ºC) |
Humidity | 10 to 90%, noncondensing |
Altitude | -500 to 6,562 ft (-52 to 2,000 m) |
Mean time between failures | 2.6 years for system configuration |
Agency approvals | UL2 1950 (U.S.) |
| AC Power Supply Specifications | |
AC total output | 388W maximum (L1010-PWR-1) |
AC-input voltage | 100 to 127/200 to 240 VAC wide input with power factor correction |
AC frequency | 50 to 60 Hz |
AC current rating | 8/4A with the chassis fully configured |
Power supply load | 376W maximum configuration, 200W typical with maximum configuration |
DC voltages supplied and steady-state maximum current ratings | +5V @ 70A |
Heat dissipation | 563W (1919 Btu11/hr) |
| DC Power Supply Specifications | |
DC total output | 388W maximum (L1010-PWR-DC) |
DC-input current | 14.0A maximum @ 48 VDC (nominal) |
Power supply load | 376W maximum, 200W typical with maximum configuration |
DC voltages supplied and steady-state maximum current ratings | +5V @ 70A |
DC-input voltage | Rated -48 VDC to -60 VDC continuous |
Heat dissipation | 600 W (2040 Btu/hr) |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Aug 25 11:11:52 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.