cc/td/doc/product/atm/ls1010s/wa4/11_3_5
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

PNNI Migration Examples

PNNI Migration Examples

This appendix provides examples of how to migrate a flat network topology to a Private Network-Network Interface (PNNI) hierarchical network topology, and includes the following sections:

Detailed PNNI configuration instructions are described in the chapter "Configuring ATM Routing and PNNI."


Note For a complete description of the commands mentioned in this chapter, refer to the LightStream  1010 ATM Switch Command Reference publication.

Adding a Higher Level of PNNI Hierarchy

Figure A-1 shows an example network with two PNNI peer groups connected by an Interim Inter-Switch Signaling Protocol (IISP) interface.


Figure A-1: Two PNNI Peer Groups Connected by an IISP Interface


You can convert the network to a single hierarchical PNNI routing domain by configuring a second level of hierarchy in each peer group and converting the IISP interface to a PNNI interface, as shown in Figure A-2.


Figure A-2: Two-Level PNNI Hierarchical Network


The initial configuration for each switch is shown in the sections that follow. The commands used to migrate the network to a two-level PNNI hierarchical network (shown in Figure A-2) are also provided.

Switch T1 Initial Configuration

The initial configuration for switch NewYork BldB.T1 follows:

hostname NewYork.BldB.T1
atm address 47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a01.00
atm router pnni
 node 1 level 72 lowest
  redistribute atm-static
 
NewYork.BldB.T1# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P SI 1   0            UP 0   47.0091.4455.6677.1144.1011.1233/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a01/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a02/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a03/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a04/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a05/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.4000.0c/128
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P  I 11  0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P  E 11  0            UP 0   47.0091.4455.6677.22/64 

Switch T2 Initial Configuration

The initial configuration for switch NewYork BldB.T2 follows:

hostname NewYork.BldB.T2
atm address 47.0091.4455.6677.1144.1011.1244.0060.3e5b.bc01.00
atm router pnni
 node 1 level 72 lowest
  redistribute atm-static
 
NewYork.BldB.T2# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P SI 1   0            UP 0   47.0091.4455.6677.1144.1011.1244/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1244.0060.3e5b.bc01/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1244.0060.3e5b.bc02/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1244.4000.0c/128
P  I 11  0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P  E 11  0            UP 0   47.0091.4455.6677.22/64 
S  E 1   ATM0/0/1     DN 0   47.0091.8200.0001.1/60 

Switch T3 Initial Configuration

The initial configuration for switch NewYork BldB.T3 follows:

hostname NewYork.BldB.T3
atm address 47.0091.4455.6677.1144.1011.1255.0060.3e5b.c401.00
atm router pnni
 node 1 level 72 lowest
  redistribute atm-static
 
interface ATM0/0/2
 no ip address
atm route 47.0091.4455.6677.22... ATM0/0/2
 
NewYork.BldB.T3# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  I 12  0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P SI 1   0            UP 0   47.0091.4455.6677.1144.1011.1255/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.0060.3e5b.c401/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.0060.3e5b.c402/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.4000.0c/128
S  E 1   ATM0/0/2     UP 0   47.0091.4455.6677.22/64 
 
NewYork.BldB.T3# show atm interface atm 0/0/2
 
Interface:      ATM0/0/2        Port-type:      oc3suni
IF Status:      UP              Admin Status:   up
Auto-config:    enabled         AutoCfgState:   completed
IF-Side:        Network         IF-type:        IISP
Uni-type:       not applicable  Uni-version:    V4.0
 
<Text omitted>

Note In the example, the interface type of interface atm 0/0/2 on NewYork.BldB.T3 is determined using Interim Local Management Interface (ILMI) autoconfiguration. Because the other side of the link on SanFran.BldA.T4 is configured as IISP, the interface type is determined to be IISP. When using ILMI autoconfiguration on one side of the link and manually configuring the other side as IISP, be careful to specify the configured side as either the user or network side, depending on whether it has the larger value of atmfMySystemIdentifier.

Switch T4 Initial Configuration

The initial configuration for switch SanFran.BldA.T4 follows:

hostname SanFran.BldA.T4
atm address 47.0091.4455.6677.2233.1011.1266.0060.3e7b.2001.00
atm router pnni
 node 1 level 72 lowest
  redistribute atm-static
 
interface ATM0/0/3
 no ip address
 no atm auto-configuration
 atm iisp side user version 4.0
atm route 47.0091.4455.6677.11... ATM0/0/3
 
SanFran.BldA.T4# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
S  E 1   ATM0/0/3     UP 0   47.0091.4455.6677.11/64 
P  I 9   0            UP 0   47.0091.4455.6677.2233.1011.1244/104
P SI 1   0            UP 0   47.0091.4455.6677.2233.1011.1266/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.0060.3e7b.2001/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.0060.3e7b.2002/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.4000.0c/128
 
SanFran.BldA.T4# show atm interface atm 0/0/3
 
Interface:      ATM0/0/3        Port-type:      oc3suni
IF Status:      UP              Admin Status:   up
Auto-config:    disabled        AutoCfgState:   not applicable
IF-Side:        User            IF-type:        IISP
Uni-type:       not applicable  Uni-version:    V4.0

Switch T5 Initial Configuration

The initial configuration for switch SanFran.BldA.T5 follows:

hostname SanFran.BldA.T5
atm address 47.0091.4455.6677.2233.1011.1244.0060.3e7b.2401.00
atm router pnni
 node 1 level 72 lowest
  redistribute atm-static
 
SanFran.BldA.T5# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  E 9   0            UP 0   47.0091.4455.6677.11/64 
P SI 1   0            UP 0   47.0091.4455.6677.2233.1011.1244/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1244.0060.3e7b.2401/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1244.0060.3e7b.2402/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1244.4000.0c/128
P  I 9   0            UP 0   47.0091.4455.6677.2233.1011.1266/104

Configure Second Level of PNNI Hierarchy on Switch T3

The following example shows how to configure and display the second level of PNNI hierarchy on switch NewYork.BldB.T3 (see Figure A-2):


Note In this example, the configuration of the second level of PNNI hierarchy on switch NewYork.BldB.T3 has no effect on new or existing connections.
NewYork.BldB.T3# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
NewYork.BldB.T3(config)# atm router pnni
NewYork.BldB.T3(config-atm-r)# node 2 level 56
NewYork.BldB.T3(config-pnni-)# name NewYork
NewYork.BldB.T3(config-pnni-)# exit
NewYork.BldB.T3(config-atm-r)# node 1
NewYork.BldB.T3(config-pnni-)# parent 2
NewYork.BldB.T3(config-pnni-)# election leadership-priority 45
NewYork.BldB.T3(config-pnni-)# end
NewYork.BldB.T3#
%SYS-5-CONFIG_I: Configured from console by console
 
NewYork.BldB.T3# show atm pnni local-node
 
PNNI node 1 is enabled and running
  Node name: NewYork.BldB.T3
  System address          47.009144556677114410111255.00603E5BC401.01
  Node ID          72:160:47.009144556677114410111255.00603E5BC401.00
  Peer group ID        72:47.0091.4455.6677.1144.0000.0000
  Level 72, Priority 45 95, No. of interfaces 3, No. of neighbors 1
  Parent Node Index: 2
 
<Text omitted>
 
PNNI node 2 is enabled and running
  Node name: NewYork
  System address          47.009144556677114410111255.00603E5BC401.02
  Node ID           56:72:47.009144556677114400000000.00603E5BC401.00
  Peer group ID        56:47.0091.4455.6677.0000.0000.0000
  Level 56, Priority 0 0, No. of interfaces 0, No. of neighbors 0
  Parent Node Index: NONE
 
<Text omitted>
 
NewYork.BldB.T3# show atm pnni hierarchy 
  Locally configured parent nodes:
  Node          Parent
  Index  Level  Index   Local-node Status     Node Name
  ~~~~~  ~~~~~  ~~~~~~  ~~~~~~~~~~~~~~~~~~~~  ~~~~~~~~~~~~~~~~~~~~~~
  1      72     2       Enabled/ Running      NewYork.BldB.T3
  2      56     N/A     Enabled/ Running      NewYork
 
NewYork.BldB.T3# show atm pnni hierarchy network
  Summary of active parent LGNs in the routing domain:
  Node  Level  Parent  Node Name
  ~~~~  ~~~~~  ~~~~~~  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  1     72     2       NewYork.BldB.T3
  2     56     0       NewYork
 
NewYork.BldB.T3# show atm pnni hierarchy network detail
  Detailed hierarchy network display:
  Number Of Network LGN Ancestors: 1
 
  Lowest Level (72) information:
  Node No.....: 1    Node Name: NewYork.BldB.T3
  Node's ID...:   72:160:47.009144556677114410111255.00603E5BC401.00
  Node's Addr.:          47.009144556677114410111255.00603E5BC401.01
  Node's PG ID:       72:47.0091.4455.6677.1144.0000.0000
  PGL No......: 1    PGL Name: NewYork.BldB.T3
  PGL ID......:   72:160:47.009144556677114410111255.00603E5BC401.00
 
  Level 56 ancestor information:
  Parent LGN..: 2    LGN Name: NewYork
  LGN's ID....:    56:72:47.009144556677114400000000.00603E5BC401.00
  LGN's Addr..:          47.009144556677114410111255.00603E5BC401.02
  LGN's PG ID.:       56:47.0091.4455.6677.0000.0000.0000
  LGN PGL No..:      Unelected or unknown
  LGN's PGL ID:      0:0:00.000000000000000000000000.000000000000.00

Configure Second Level of PNNI Hierarchy on Switch T4

The following example shows how to configure and display the second level of PNNI hierarchy on switch NewYork.BldB.T4 (see Figure A-2):


Note In this example, the configuration of the second level of PNNI hierarchy on switch SanFran.BldA.T4 has no effect on new or existing connections.
SanFran.BldA.T4# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
SanFran.BldA.T4(config)# atm router pnni
SanFran.BldA.T4(config-atm-r)# node 2 level 56
SanFran.BldA.T4(config-pnni-)# name SanFran
SanFran.BldA.T4(config-pnni-)# exit
SanFran.BldA.T4(config-atm-r)# node 1
SanFran.BldA.T4(config-pnni-)# parent 2
SanFran.BldA.T4(config-pnni-)# election leadership-priority 45
SanFran.BldA.T4(config-pnni-)# end
SanFran.BldA.T4#
%SYS-5-CONFIG_I: Configured from console by console
 
SanFran.BldA.T4# show atm pnni local-node
 
PNNI node 1 is enabled and running
  Node name: SanFran.BldA.T4
  System address          47.009144556677223310111266.00603E7B2001.01
  Node ID          72:160:47.009144556677223310111266.00603E7B2001.00
  Peer group ID        72:47.0091.4455.6677.2233.0000.0000
  Level 72, Priority 45 95, No. of interfaces 3, No. of neighbors 1
  Parent Node Index: 2
 
<Text omitted>
 
PNNI node 2 is enabled and running
  Node name: SanFran
  System address          47.009144556677223310111266.00603E7B2001.02
  Node ID           56:72:47.009144556677223300000000.00603E7B2001.00
  Peer group ID        56:47.0091.4455.6677.0000.0000.0000
  Level 56, Priority 0 0, No. of interfaces 0, No. of neighbors 0
  Parent Node Index: NONE
 
<Text omitted>
 
SanFran.BldA.T4# show atm pnni hierarchy
  Locally configured parent nodes:
  Node          Parent
  Index  Level  Index   Local-node Status     Node Name
  ~~~~~  ~~~~~  ~~~~~~  ~~~~~~~~~~~~~~~~~~~~  ~~~~~~~~~~~~~~~~~~~~~~
  1      72     2       Enabled/ Running      SanFran.BldA.T4
  2      56     N/A     Enabled/ Running      SanFran
 
SanFran.BldA.T4# show atm pnni hierarchy network
  Summary of active parent LGNs in the routing domain:
  Node  Level  Parent  Node Name
  ~~~~  ~~~~~  ~~~~~~  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  1     72     2       SanFran.BldA.T4
  2     56     0       SanFran
 
SanFran.BldA.T4# show atm pnni hierarchy network detail
  Detailed hierarchy network display:
  Number Of Network LGN Ancestors: 1
 
  Lowest Level (72) information:
  Node No.....: 1    Node Name: SanFran.BldA.T4
  Node's ID...:   72:160:47.009144556677223310111266.00603E7B2001.00
  Node's Addr.:          47.009144556677223310111266.00603E7B2001.01
  Node's PG ID:       72:47.0091.4455.6677.2233.0000.0000
  PGL No......: 1    PGL Name: SanFran.BldA.T4
  PGL ID......:   72:160:47.009144556677223310111266.00603E7B2001.00
 
  Level 56 ancestor information:
  Parent LGN..: 2    LGN Name: SanFran
  LGN's ID....:    56:72:47.009144556677223300000000.00603E7B2001.00
  LGN's Addr..:          47.009144556677223310111266.00603E7B2001.02
  LGN's PG ID.:       56:47.0091.4455.6677.0000.0000.0000
  LGN PGL No..:      Unelected or unknown
  LGN's PGL ID:      0:0:00.000000000000000000000000.000000000000.00

Configure the Link Between Switch T3 and Switch T4 for PNNI

The following example shows how to configure the link between switch NewYorkBldB.T3 and SanFran.BldA.T4 for PNNI.


Note In this example, only one side of the IISP interface is configured to change the link from IISP to PNNI because the other side of the link is using ILMI autoconfiguration for the interface type. You can use either the atm auto-configuration or atm nni command to change the link from IISP to PNNI.
SanFran.BldA.T4# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
SanFran.BldA.T4(config)# int atm0/0/3
SanFran.BldA.T4(config-if)# atm auto-configuration
SanFran.BldA.T4(config-if)# end
SanFran.BldA.T4#
%ATM-5-ATMSOFTSTART: Restarting ATM signalling and ILMI on ATM0/0/3.

Note When you change the link from IISP to PNNI, all existing connections across the interface are cleared. The ability to route new connections across the link is restored within a few seconds, when the PNNI uplinks and induced horizontal link come up.

Verify Connectivity to All ATM Addresses and Delete Old Static Route on Switch  T4

The following example shows how to verify connectivity to all ATM addresses before deleting an old static route on switch T4:

SanFran.BldA.T4# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

S E 1 ATM0/0/3 DN 0 47.0091.4455.6677.11/64 P I 12 0 UP 0 47.0091.4455.6677.1144/72 P SI 2 0 UP 0 47.0091.4455.6677.2233/72 P I 9 0 UP 0 47.0091.4455.6677.2233.1011.1244/104 P SI 1 0 UP 0 47.0091.4455.6677.2233.1011.1266/104 R I 1 ATM2/0/0 UP 0 47.0091.4455.6677.2233.1011.1266.0060.3e7b.2001/152 R I 1 ATM2/0/0 UP 0 47.0091.4455.6677.2233.1011.1266.0060.3e7b.2002/152 R I 1 ATM2/0/0 UP 0 47.0091.4455.6677.2233.1011.1266.4000.0c/128

The following example shows how to delete the old static route:

SanFran.BldA.T4# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
SanFran.BldA.T4(config)# no atm route 47.0091.4455.6677.11 atm0/0/3
SanFran.BldA.T4(config)# end
SanFran.BldA.T4#
%SYS-5-CONFIG_I: Configured from console by console
 

The following example verifies that the old static route on switch T4 has been deleted:

SanFran.BldA.T4# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  I 12  0            UP 0   47.0091.4455.6677.1144/72 
P SI 2   0            UP 0   47.0091.4455.6677.2233/72 
P  I 9   0            UP 0   47.0091.4455.6677.2233.1011.1244/104
P SI 1   0            UP 0   47.0091.4455.6677.2233.1011.1266/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.0060.3e7b.2001/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.0060.3e7b.2002/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.4000.0c/128

Verify Connectivity to All ATM Addresses and Delete Old Static Route on Switch  T3

The following example shows how to verify connectivity to all ATM addresses before deleting an old static route on switch T3:

NewYork.BldB.T3#
%ATM-4-ILMICONFIGCHANGE: ILMI(ATM0/0/2): Restarting ATM signalling and ILMI. Peer Configuration change detected.
%ATM-5-ATMSOFTSTART: Restarting ATM signalling and ILMI on ATM0/0/2.
NewYork.BldB.T3# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P SI 2   0            UP 0   47.0091.4455.6677.1144/72 
P  I 12  0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P SI 1   0            UP 0   47.0091.4455.6677.1144.1011.1255/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.0060.3e5b.c401/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.0060.3e5b.c402/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.4000.0c/128

S E 1 ATM0/0/2 DN 0 47.0091.4455.6677.22/64 P I 13 0 UP 0 47.0091.4455.6677.2233/72

The following example shows how to delete the old static route:

NewYork.BldB.T3# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
NewYork.BldB.T3(config)# no atm route 47.0091.4455.6677.22 atm 0/0/2
NewYork.BldB.T3(config)# end
NewYork.BldB.T3#
%SYS-5-CONFIG_I: Configured from console by console
 

The following example verifies that the old static route on switch T3 has been deleted:

NewYork.BldB.T3# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P SI 2   0            UP 0   47.0091.4455.6677.1144/72 
P  I 12  0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P SI 1   0            UP 0   47.0091.4455.6677.1144.1011.1255/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.0060.3e5b.c401/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.0060.3e5b.c402/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.4000.0c/128
P  I 13  0            UP 0   47.0091.4455.6677.2233/72

Adding a New Lowest Level of the PNNI Hierarchy

Figure A-3 shows an example network configured with only one level of PNNI hierarchy at level  56.


Figure A-3: One-Level PNNI Hierarchical Network


You can convert the network into a two-level hierarchical PNNI network by bringing each lowest level node down to level 72 and splitting the network into two peer groups. At the same time, you can add a second level of hierarchy at level 56. The resulting network topology is shown in Figure A-4.


Figure A-4: Two-Level PNNI Hierarchical Network



Note This example assumes that all addresses have already been assigned according to a hierarchical ATM address plan. All the switches share the same 56-bit prefix. The switches in Building A in San Francisco share the same 72-bit prefix. The switches in Building B in New York share a different 72-bit prefix. As a result, no renumbering is necessary to migrate the network from a single level of PNNI hierarchy to two levels of PNNI hierarchy.

Note If no renumbering is necessary and all switches are peer group leader/logical group node (PGL/LGN)-capable (Cisco  IOS Release  11.3T, WA4, or later releases), existing connections are not affected by the migration process. The existing connections remain active while you modify the PNNI configuration.

You can implement the migration process one switch at a time. As each switch is moved down to level  72, the ability to establish new connections across that switch is lost temporarily and then automatically restored. You can pause for long periods of time during the migration process without any harmful effects.

The initial configuration for each switch is shown in the sections that follow. The commands used to migrate the network to the two-level PNNI hierarchical network (shown in Figure A-4) are also provided.

Switch T1 Initial Configuration

The initial configuration for switch NewYork BldB.T1 follows:

hostname NewYork.BldB.T1
atm address 47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a01.00
atm router pnni
 node 1 level 56 lowest
  redistribute atm-static
 
NewYork.BldB.T1# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P SI 1   0            UP 0   47.0091.4455.6677.1144.1011.1233/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a01/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a02/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a03/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a04/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a05/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.4000.0c/128
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P  I 10  0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P  I 12  0            UP 0   47.0091.4455.6677.2233.1011.1244/104
P  I 11  0            UP 0   47.0091.4455.6677.2233.1011.1266/104

Switch T2 Initial Configuration

The initial configuration for switch NewYork BldB.T2 follows:

hostname NewYork.BldB.T2
atm address 47.0091.4455.6677.1144.1011.1244.0060.3e5b.bc01.00
atm router pnni
 node 1 level 56 lowest
  redistribute atm-static
 
NewYork.BldB.T2# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P SI 1   0            UP 0   47.0091.4455.6677.1144.1011.1244/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1244.0060.3e5b.bc01/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1244.0060.3e5b.bc02/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1244.4000.0c/128
P  I 10  0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P  I 12  0            UP 0   47.0091.4455.6677.2233.1011.1244/104
P  I 11  0            UP 0   47.0091.4455.6677.2233.1011.1266/104

Switch T3 Initial Configuration

The initial configuration for switch NewYork BldB.T3 follows:

hostname NewYork.BldB.T3
atm address 47.0091.4455.6677.1144.1011.1255.0060.3e5b.c401.00
atm router pnni
 node 1 level 56 lowest
  redistribute atm-static
 
NewYork.BldB.T3# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  I 10  0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P SI 1   0            UP 0   47.0091.4455.6677.1144.1011.1255/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.0060.3e5b.c401/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.0060.3e5b.c402/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.4000.0c/128
P  I 12  0            UP 0   47.0091.4455.6677.2233.1011.1244/104
P  I 11  0            UP 0   47.0091.4455.6677.2233.1011.1266/104

Switch T4 Initial Configuration

The initial configuration for switch SanFran.BldA.T4 follows:

hostname SanFran.BldA.T4
atm address 47.0091.4455.6677.2233.1011.1266.0060.3e7b.2001.00
atm router pnni
 node 1 level 56 lowest
  redistribute atm-static
 
SanFran.BldA.T4# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  I 11  0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 10  0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P  I 12  0            UP 0   47.0091.4455.6677.2233.1011.1244/104
P SI 1   0            UP 0   47.0091.4455.6677.2233.1011.1266/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.0060.3e7b.2001/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.0060.3e7b.2002/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.4000.0c/128

Switch T5 Initial Configuration

The initial configuration for switch SanFran.BldA.T5 follows:

hostname SanFran.BldA.T5
atm address 47.0091.4455.6677.2233.1011.1244.0060.3e7b.2401.00
atm router pnni
 node 1 level 56 lowest
  redistribute atm-static
 
SanFran.BldA.T5# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  I 12  0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 11  0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P  I 10  0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P SI 1   0            UP 0   47.0091.4455.6677.2233.1011.1244/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1244.0060.3e7b.2401/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1244.0060.3e7b.2402/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1244.4000.0c/128
P  I 9   0            UP 0   47.0091.4455.6677.2233.1011.1266/104

Move Switch T4 Down Into a New Peer Group

The first switch you move down into a new peer group at level 72 should be the switch you prefer as the PGL. Before moving down the first switch, configure the LGN for the second level of hierarchy on the switch.


Note We recommend that you enter the no auto-summary command to disable auto-summary on all new LGNs during the migration process. PNNI always routes to the node that advertises the longest matching reachable address prefix; therefore, auto-summary is not required. Furthermore, debugging is easier when auto-summary is disabled. If anything goes wrong during the migration process, you can use the show atm route command to debug the problem. After all the nodes have been moved into the child peer group represented by the LGN, restore auto-summary to reduce the number of reachable address prefixes advertised by the LGN.

Figure A-5 shows the network topology after moving switch SanFran.BldA.T4 down into a new peer group at level 72 and establishing an LGN representing that peer group at level 56.


Figure A-5: Moving a Switch Down in the PNNI Hierarchy


Although switches SanFran.BldA.T5 and NewYork.BldB.T3 are not running any PGLs or LGNs in this example, these switches must be capable of establishing the PNNI hierarchy. This capability allows them to bring up the induced horizontal links to the LGN SanFran, maintaining PNNI connectivity across the network. For this reason, we recommend that you upgrade all switches to Cisco IOS Release  11.3T, WA4 or later, before configuring PNNI hierarchy.

The following example shows how to move switch SanFran.BldA.T4 down into a new peer group:

SanFran.BldA.T4# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
SanFran.BldA.T4(config)# atm router pnni
SanFran.BldA.T4(config-atm-r)# node 2 level 56
SanFran.BldA.T4(config-pnni-)# name SanFran
SanFran.BldA.T4(config-pnni-)# no auto-summary
SanFran.BldA.T4(config-pnni-)# exit  
SanFran.BldA.T4(config-atm-r)# node 1
SanFran.BldA.T4(config-pnni-)# election leadership-priority 45
SanFran.BldA.T4(config-pnni-)# node 1 disable
SanFran.BldA.T4(config-pnni-)# node 1 level 72
SanFran.BldA.T4(config-pnni-)# parent 2
SanFran.BldA.T4(config-pnni-)# node 1 enable
SanFran.BldA.T4(config-pnni-)# end
SanFran.BldA.T4#
%SYS-5-CONFIG_I: Configured from console by console

Note When you move down the first switch into a new peer group, the switch cannot establish new connections until it can elect itself PGL. By default, this election process takes approximately 90  seconds, or less if a second switch is brought into the peer group quickly. After the new configuration on this switch is stable, the PNNI network is fully functional and new connections can be accepted across all switches.

The following examples show how to verify the configuration:

SanFran.BldA.T4# show atm pnni local-node
 
PNNI node 1 is enabled and running
  Node name: SanFran.BldA.T4
  System address          47.009144556677223310111266.00603E7B2001.01
  Node ID          72:160:47.009144556677223310111266.00603E7B2001.00
  Peer group ID        72:47.0091.4455.6677.2233.0000.0000
  Level 72, Priority 45 95, No. of interfaces 3, No. of neighbors 0
  Parent Node Index: 2
 
<Text omitted>
 
PNNI node 2 is enabled and running
  Node name: SanFran
  System address          47.009144556677223310111266.00603E7B2001.02
  Node ID           56:72:47.009144556677223300000000.00603E7B2001.00
  Peer group ID        56:47.0091.4455.6677.0000.0000.0000
  Level 56, Priority 0 0, No. of interfaces 0, No. of neighbors 2
  Parent Node Index: NONE
 
<Text omitted>
 
SanFran.BldA.T4# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  I 12  0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 11  0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P  I 10  0            UP 0   47.0091.4455.6677.2233.1011.1244/104
P SI 1   0            UP 0   47.0091.4455.6677.2233.1011.1266/104
P  I 2   0            UP 0   47.0091.4455.6677.2233.1011.1266/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.0060.3e7b.2001/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.0060.3e7b.2002/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.4000.0c/128

Move Switch SanFran.BldA.T5 Down Into An Existing Peer Group

After you move the first switch down to form a new peer group, you can move the remaining switches down into the peer group one by one. You should move the switches down in an order that keeps the peer group contiguous.

The following example shows how to move switch SanFran.BldA.T5 down into a peer group at level  72:

SanFran.BldA.T5# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
SanFran.BldA.T5(config)# atm router pnni
SanFran.BldA.T5(config-atm-r)# node 1 disable
SanFran.BldA.T5(config-pnni-)# node 1 level 72 enable
SanFran.BldA.T5(config-pnni-)# end
SanFran.BldA.T5#
%SYS-5-CONFIG_I: Configured from console by console

Note When you move a switch down into an existing peer group, the ability to establish new connections across that switch is lost temporarily (up to several seconds).

The following examples show how to verify the configuration:

SanFran.BldA.T5# show atm pnni local-node
 
PNNI node 1 is enabled and running
  Node name: SanFran.BldA.T5
  System address          47.009144556677223310111244.00603E7B2401.01
  Node ID          72:160:47.009144556677223310111244.00603E7B2401.00
  Peer group ID        72:47.0091.4455.6677.2233.0000.0000
  Level 72, Priority 0 0, No. of interfaces 2, No. of neighbors 1
  Parent Node Index: NONE
 
<Text omitted>
 
SanFran.BldA.T5# show atm pnni hierarchy network
  Summary of active parent LGNs in the routing domain:
  Node  Level  Parent  Node Name
  ~~~~  ~~~~~  ~~~~~~  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  1     72     14      SanFran.BldA.T5
  14    56     0       SanFran
SanFran.BldA.T5# show atm pnni hierarchy network detail
  Detailed hierarchy network display:
  Number Of Network LGN Ancestors: 1
 
  Lowest Level (72) information:
  Node No.....: 1    Node Name: SanFran.BldA.T5
  Node's ID...:   72:160:47.009144556677223310111244.00603E7B2401.00
  Node's Addr.:          47.009144556677223310111244.00603E7B2401.01
  Node's PG ID:       72:47.0091.4455.6677.2233.0000.0000
  PGL No......: 10   PGL Name: SanFran.BldA.T4
  PGL ID......:   72:160:47.009144556677223310111266.00603E7B2001.00
 
  Level 56 ancestor information:
  Parent LGN..: 14   LGN Name: SanFran
  LGN's ID....:    56:72:47.009144556677223300000000.00603E7B2001.00
  LGN's Addr..:          47.009144556677223310111266.00603E7B2001.02
  LGN's PG ID.:       56:47.0091.4455.6677.0000.0000.0000
  LGN PGL No..:      Unelected or unknown
  LGN's PGL ID:      0:0:00.000000000000000000000000.000000000000.00
 
SanFran.BldA.T5# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  I 13  0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 12  0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P  I 11  0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P SI 1   0            UP 0   47.0091.4455.6677.2233.1011.1244/104
P  I 14  0            UP 0   47.0091.4455.6677.2233.1011.1244/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1244.0060.3e7b.2401/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1244.0060.3e7b.2402/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1244.4000.0c/128
P  I 10  0            UP 0   47.0091.4455.6677.2233.1011.1266/104
P  I 14  0            UP 0   47.0091.4455.6677.2233.1011.1266/104
 

You can configure one or more of the switches that have been moved down into the peer group as a backup PGL. The following example shows how to configure SanFran.BldA.T5 as a backup PGL for the peer group SanFran (see Figure A-4):

SanFran.BldA.T5# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
SanFran.BldA.T5(config)# atm router pnni
SanFran.BldA.T5(config-atm-r)# node 2 level 56
SanFran.BldA.T5(config-pnni-)# name SanFran
SanFran.BldA.T5(config-pnni-)# no auto-summary
SanFran.BldA.T5(config-pnni-)# exit
SanFran.BldA.T5(config-atm-r)# node 1
SanFran.BldA.T5(config-pnni-)# election leadership-priority 10
SanFran.BldA.T5(config-pnni-)# parent 2
SanFran.BldA.T5(config-pnni-)# end
SanFran.BldA.T5#
%SYS-5-CONFIG_I: Configured from console by console
SanFran.BldA.T5# show atm pnni local-node
 
PNNI node 1 is enabled and running
  Node name: SanFran.BldA.T5
  System address          47.009144556677223310111244.00603E7B2401.01
  Node ID          72:160:47.009144556677223310111244.00603E7B2401.00
  Peer group ID        72:47.0091.4455.6677.2233.0000.0000
  Level 72, Priority 10 10, No. of interfaces 2, No. of neighbors 1
  Parent Node Index: 2
 
<Text omitted>
 
PNNI node 2 is enabled and not running
  Node name: SanFran
  System address          47.009144556677223310111244.00603E7B2401.02
  Node ID           56:72:47.009144556677223300000000.00603E7B2401.00
  Peer group ID        56:47.0091.4455.6677.0000.0000.0000
  Level 56, Priority 0 0, No. of interfaces 0, No. of neighbors 0
  Parent Node Index: NONE
 
<Text omitted>
 
SanFran.BldA.T5# show atm pnni hierarchy 
  Locally configured parent nodes:
  Node          Parent
  Index  Level  Index   Local-node Status     Node Name
  ~~~~~  ~~~~~  ~~~~~~  ~~~~~~~~~~~~~~~~~~~~  ~~~~~~~~~~~~~~~~~~~~~~
  1      72     2       Enabled/ Running      SanFran.BldA.T5
  2      56     N/A     Enabled/ Not Running  SanFran
 
SanFran.BldA.T5# show atm pnni hierarchy network
  Summary of active parent LGNs in the routing domain:
  Node  Level  Parent  Node Name
  ~~~~  ~~~~~  ~~~~~~  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  1     72     14      SanFran.BldA.T5
  14    56     0       SanFran

Restore Auto-Summary on the LGN SanFran

After all the nodes destined for the new peer group migrate into the peer group, you can restore auto-summary to reduce the number of reachable address prefixes advertised by the LGN.

The following example shows how to enable auto-summary on the LGN SanFran:

SanFran.BldA.T5# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
SanFran.BldA.T5(config)# atm router pnni
SanFran.BldA.T5(config-atm-r)# node 2 
SanFran.BldA.T5(config-pnni-)# auto-summary
SanFran.BldA.T5(config-pnni-)# end
SanFran.BldA.T5#
%SYS-5-CONFIG_I: Configured from console by console
 

The following example shows how to verify the configuration:

SanFran.BldA.T5# show atm pnni summary
 
Codes: Node - Node index advertising this summary
       Type - Summary type (INT - internal, EXT - exterior)
       Sup  - Suppressed flag (Y - Yes, N - No)
       Auto - Auto Summary flag (Y - Yes, N - No)
       Adv  - Advertised flag (Y - Yes, N - No)
 
 Node Type Sup Auto Adv  Summary Prefix
 ~~~~ ~~~~ ~~~ ~~~~ ~~~  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  1   Int   N   Y    Y   47.0091.4455.6677.2233.1011.1244/104
  2   Int   N   Y    N   47.0091.4455.6677.2233/72 
 

The switch that contains the active PGL is configured similarly:

SanFran.BldA.T4# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
SanFran.BldA.T4(config)# atm router pnni
SanFran.BldA.T4(config-atm-r)# node 2
SanFran.BldA.T4(config-pnni-)# auto-summary
SanFran.BldA.T4(config-pnni-)# end
SanFran.BldA.T4#
%SYS-5-CONFIG_I: Configured from console by console
 

The following examples show how to verify the configuration:

SanFran.BldA.T4# show atm pnni summary
 
Codes: Node - Node index advertising this summary
       Type - Summary type (INT - internal, EXT - exterior)
       Sup  - Suppressed flag (Y - Yes, N - No)
       Auto - Auto Summary flag (Y - Yes, N - No)
       Adv  - Advertised flag (Y - Yes, N - No)
 
 Node Type Sup Auto Adv  Summary Prefix
 ~~~~ ~~~~ ~~~ ~~~~ ~~~  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  1   Int   N   Y    Y   47.0091.4455.6677.2233.1011.1266/104
  2   Int   N   Y    Y   47.0091.4455.6677.2233/72 
 
SanFran.BldA.T4# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  I 12  0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 11  0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P SI 2   0            UP 0   47.0091.4455.6677.2233/72 
P  I 13  0            UP 0   47.0091.4455.6677.2233.1011.1244/104
P SI 1   0            UP 0   47.0091.4455.6677.2233.1011.1266/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.0060.3e7b.2001/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.0060.3e7b.2002/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.2233.1011.1266.4000.0c/128

Move Switch T3 Down Into a New Peer Group

The following example shows how to move switch NewYork.BldB.T3 down into a new peer group:

NewYork.BldB.T3# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
NewYork.BldB.T3(config)# atm router pnni
NewYork.BldB.T3(config-atm-r)# node 2 level 56
NewYork.BldB.T3(config-pnni-)# name NewYork
NewYork.BldB.T3(config-pnni-)# no auto-summary
NewYork.BldB.T3(config-pnni-)# exit
NewYork.BldB.T3(config-atm-r)# node 1
NewYork.BldB.T3(config-pnni-)# election leadership-priority 45
NewYork.BldB.T3(config-pnni-)# node 1 disable
NewYork.BldB.T3(config-pnni-)# node 1 level 72
NewYork.BldB.T3(config-pnni-)# parent 2
NewYork.BldB.T3(config-pnni-)# node 1 enable
NewYork.BldB.T3(config-pnni-)# end
NewYork.BldB.T3#
%SYS-5-CONFIG_I: Configured from console by console
 

The following examples show how to verify the configuration:

NewYork.BldB.T3# show atm pnni local-node
 
PNNI node 1 is enabled and running
  Node name: NewYork.BldB.T3
  System address          47.009144556677114410111255.00603E5BC401.01
  Node ID          72:160:47.009144556677114410111255.00603E5BC401.00
  Peer group ID        72:47.0091.4455.6677.1144.0000.0000
  Level 72, Priority 45 95, No. of interfaces 3, No. of neighbors 0
  Parent Node Index: 2
 
<Text omitted>
 
PNNI node 2 is enabled and running
  Node name: NewYork
  System address          47.009144556677114410111255.00603E5BC401.02
  Node ID           56:72:47.009144556677114400000000.00603E5BC401.00
  Peer group ID        56:47.0091.4455.6677.0000.0000.0000
  Level 56, Priority 0 0, No. of interfaces 0, No. of neighbors 2
  Parent Node Index: NONE
 
<Text omitted>
 
NewYork.BldB.T3# show atm pnni hierarchy
  Locally configured parent nodes:
  Node          Parent
  Index  Level  Index   Local-node Status     Node Name
  ~~~~~  ~~~~~  ~~~~~~  ~~~~~~~~~~~~~~~~~~~~  ~~~~~~~~~~~~~~~~~~~~~~
  1      72     2       Enabled/ Running      NewYork.BldB.T3
  2      56     N/A     Enabled/ Running      NewYork
 
NewYork.BldB.T3# show atm pnni hierarchy network detail
  Detailed hierarchy network display:
  Number Of Network LGN Ancestors: 1
 
  Lowest Level (72) information:
  Node No.....: 1    Node Name: NewYork.BldB.T3
  Node's ID...:   72:160:47.009144556677114410111255.00603E5BC401.00
  Node's Addr.:          47.009144556677114410111255.00603E5BC401.01
  Node's PG ID:       72:47.0091.4455.6677.1144.0000.0000
  PGL No......: 1    PGL Name: NewYork.BldB.T3
  PGL ID......:   72:160:47.009144556677114410111255.00603E5BC401.00
 
  Level 56 ancestor information:
  Parent LGN..: 2    LGN Name: NewYork
  LGN's ID....:    56:72:47.009144556677114400000000.00603E5BC401.00
  LGN's Addr..:          47.009144556677114410111255.00603E5BC401.02
  LGN's PG ID.:       56:47.0091.4455.6677.0000.0000.0000
  LGN PGL No..:      Unelected or unknown
  LGN's PGL ID:      0:0:00.000000000000000000000000.000000000000.00
 
NewYork.BldB.T3# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 11  0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P SI 1   0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P  I 2   0            UP 0   47.0091.4455.6677.1144.1011.1255/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.0060.3e5b.c401/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.0060.3e5b.c402/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.4000.0c/128
P  I 10  0            UP 0   47.0091.4455.6677.2233/72 

Move Switch T1 Down Into an Existing Peer Group

The following example shows how to move switch NewYork.BldB.T1 down into a new peer group:

NewYork.BldB.T1# configure 
%SYS-5-CONFIG_I: Configured from console                   
NewYork.BldB.T1# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
NewYork.BldB.T1(config)# atm router pnni
NewYork.BldB.T1(config-atm-r)# node 1 disable
NewYork.BldB.T1(config-pnni-)# node 1 level 72 enable
NewYork.BldB.T1(config-pnni-)# end
NewYork.BldB.T1#
%SYS-5-CONFIG_I: Configured from console by console
 

The following examples show how to verify the configuration:

NewYork.BldB.T1# show atm pnni local-node
 
PNNI node 1 is enabled and running
  Node name: NewYork.BldB.T1
  System address          47.009144556677114410111233.00603E7B3A01.01
  Node ID          72:160:47.009144556677114410111233.00603E7B3A01.00
  Peer group ID        72:47.0091.4455.6677.1144.0000.0000
  Level 72, Priority 0 0, No. of interfaces 3, No. of neighbors 1
  Parent Node Index: NONE
 
<Text omitted>
 
NewYork.BldB.T1# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P SI 1   0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 13  0            UP 0   47.0091.4455.6677.1144.1011.1233/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a01/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a02/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a03/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a04/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.0060.3e7b.3a05/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1233.4000.0c/128
P  I 12  0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P  I 10  0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P  I 13  0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P  I 11  0            UP 0   47.0091.4455.6677.2233/72 
 
NewYork.BldB.T1# show atm pnni hierarchy network
  Summary of active parent LGNs in the routing domain:
  Node  Level  Parent  Node Name
  ~~~~  ~~~~~  ~~~~~~  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  1     72     13      NewYork.BldB.T1
  13    56     0       NewYork
NewYork.BldB.T1# show atm pnni hierarchy network detail
  Detailed hierarchy network display:
  Number Of Network LGN Ancestors: 1
 
  Lowest Level (72) information:
  Node No.....: 1    Node Name: NewYork.BldB.T1
  Node's ID...:   72:160:47.009144556677114410111233.00603E7B3A01.00
  Node's Addr.:          47.009144556677114410111233.00603E7B3A01.01
  Node's PG ID:       72:47.0091.4455.6677.1144.0000.0000
  PGL No......: 10   PGL Name: NewYork.BldB.T3
  PGL ID......:   72:160:47.009144556677114410111255.00603E5BC401.00
 
  Level 56 ancestor information:
  Parent LGN..: 13   LGN Name: NewYork
  LGN's ID....:    56:72:47.009144556677114400000000.00603E5BC401.00
  LGN's Addr..:          47.009144556677114410111255.00603E5BC401.02
  LGN's PG ID.:       56:47.0091.4455.6677.0000.0000.0000
  LGN PGL No..:      Unelected or unknown
  LGN's PGL ID:      0:0:00.000000000000000000000000.000000000000.00

Move Switch T2 Down Into an Existing Peer Group

The following example shows how to move switch NewYork.BldB.T2 down into a new peer group:

NewYork.BldB.T2# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
NewYork.BldB.T2(config)# atm router pnni
NewYork.BldB.T2(config-atm-r)# node 1 disable
NewYork.BldB.T2(config-pnni-)# node 1 level 72 enable
NewYork.BldB.T2(config-pnni-)# end
NewYork.BldB.T2#
%SYS-5-CONFIG_I: Configured from console by console
 

The following examples show how to verify the configuration:

NewYork.BldB.T2# show atm pnni local-node
 
PNNI node 1 is enabled and running
  Node name: NewYork.BldB.T2
  System address          47.009144556677114410111244.00603E5BBC01.01
  Node ID          72:160:47.009144556677114410111244.00603E5BBC01.00
  Peer group ID        72:47.0091.4455.6677.1144.0000.0000
  Level 72, Priority 0 0, No. of interfaces 3, No. of neighbors 1
  Parent Node Index: NONE
 
<Text omitted>
 
NewYork.BldB.T2# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 13  0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P SI 1   0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P  I 13  0            UP 0   47.0091.4455.6677.1144.1011.1244/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1244.0060.3e5b.bc01/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1244.0060.3e5b.bc02/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1244.4000.0c/128
P  I 11  0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P  I 13  0            UP 0   47.0091.4455.6677.1144.1011.1255/104
P  I 12  0            UP 0   47.0091.4455.6677.2233/72 
 
NewYork.BldB.T2# show atm pnni hierarchy network
  Summary of active parent LGNs in the routing domain:
  Node  Level  Parent  Node Name
  ~~~~  ~~~~~  ~~~~~~  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  1     72     13      NewYork.BldB.T2
  13    56     0       NewYork
NewYork.BldB.T2# show atm pnni hierarchy network detail
  Detailed hierarchy network display:
  Number Of Network LGN Ancestors: 1
 
  Lowest Level (72) information:
  Node No.....: 1    Node Name: NewYork.BldB.T2
  Node's ID...:   72:160:47.009144556677114410111244.00603E5BBC01.00
  Node's Addr.:          47.009144556677114410111244.00603E5BBC01.01
  Node's PG ID:       72:47.0091.4455.6677.1144.0000.0000
  PGL No......: 11   PGL Name: NewYork.BldB.T3
  PGL ID......:   72:160:47.009144556677114410111255.00603E5BC401.00
 
  Level 56 ancestor information:
  Parent LGN..: 13   LGN Name: NewYork
  LGN's ID....:    56:72:47.009144556677114400000000.00603E5BC401.00
  LGN's Addr..:          47.009144556677114410111255.00603E5BC401.02
  LGN's PG ID.:       56:47.0091.4455.6677.0000.0000.0000
  LGN PGL No..:      Unelected or unknown
  LGN's PGL ID:      0:0:00.000000000000000000000000.000000000000.00

Restore Auto-Summary on the LGN NewYork

The following example shows how to restore auto-summary on the LGN NewYork:

NewYork.BldB.T3# configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
NewYork.BldB.T3(config)# atm router pnni
NewYork.BldB.T3(config-atm-r)# node 2
NewYork.BldB.T3(config-pnni-)# auto-summary
NewYork.BldB.T3(config-pnni-)# end
NewYork.BldB.T3#
%SYS-5-CONFIG_I: Configured from console by console
 

The following examples show how to verify the configuration:

NewYork.BldB.T3# show atm pnni summary
 
Codes: Node - Node index advertising this summary
       Type - Summary type (INT - internal, EXT - exterior)
       Sup  - Suppressed flag (Y - Yes, N - No)
       Auto - Auto Summary flag (Y - Yes, N - No)
       Adv  - Advertised flag (Y - Yes, N - No)
 
 Node Type Sup Auto Adv  Summary Prefix
 ~~~~ ~~~~ ~~~ ~~~~ ~~~  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  1   Int   N   Y    Y   47.0091.4455.6677.1144.1011.1255/104
  2   Int   N   Y    Y   47.0091.4455.6677.1144/72 
 
NewYork.BldB.T3# show atm route
 
Codes: P - installing Protocol (S - Static, P - PNNI, R - Routing control),
       T - Type (I - Internal prefix, E - Exterior prefix, SE -
                 Summary Exterior prefix, SI - Summary Internal prefix,
                 ZE - Suppress Summary Exterior, ZI - Suppress Summary Internal)
 
P  T Node/Port        St Lev Prefix
~ ~~ ~~~~~~~~~~~~~~~~ ~~ ~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
P SI 2   0            UP 0   47.0091.4455.6677.1144/72 
P  I 12  0            UP 0   47.0091.4455.6677.1144.1011.1233/104
P  I 9   0            UP 0   47.0091.4455.6677.1144.1011.1244/104
P SI 1   0            UP 0   47.0091.4455.6677.1144.1011.1255/104
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.0060.3e5b.c401/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.0060.3e5b.c402/152
R  I 1   ATM2/0/0     UP 0   47.0091.4455.6677.1144.1011.1255.4000.0c/128
P  I 10  0            UP 0   47.0091.4455.6677.2233/72 


hometocprevnextglossaryfeedbacksearchhelp