The LightStream 1010 ATM switch chassis and power supply specifications are described in Table B-1.
| Description | Specifications |
|---|---|
Dimensions (H x W x D) | 10.4 x 17.25 x 18.4 in. (26.4 x 43.1 x 46.0 cm) |
Weight | Chassis only: 32 lb (13.6 kg) |
Airflow | 95 cfm1 through the system fan assembly |
Operating temperature | 32 to 104ºF (0 to 40ºC) |
Nonoperating temperature | -40 to 167ºF (-40 to 75ºC) |
Humidity | 10 to 90%, noncondensing |
Altitude | -500 to 10,000 ft (-52 to 3,048 m) |
Mean time between failures | 2.6 years for system configuration |
Agency approvals | Safety: UL2 1950, CSA3-C22.2 No. 950, EN60950, IEC9504, TS001, AS/ZNS 3260 |
| AC Power Supply Specifications | |
AC total output | 388W maximum (L1010-PWR-1) |
AC-input voltage | 100-240 VAC wide input with power factor correction |
AC frequency | Auto sensing limits: 100 to 127/200 to 240 VAC, 8/4A, 47 to 63 Hz |
AC current rating | Maximum power budget: 8A @ 115 VAC, 60 Hz 4A @ 230 VAC, 50 Hz |
Power supply load | 376W maximum configuration, 200W typical with maximum configuration |
DC voltages supplied and steady-state maximum current ratings | +5V @ 70A |
Heat dissipation | 563W (1919 Btu6/hr) |
| DC Power Supply Specifications | |
DC total output | 388W maximum (L1010-PWR-DC) |
DC-input current | 14.0A maximum @ 48 VDC (nominal) |
Power supply load | 376W maximum, 200W typical with maximum configuration |
DC voltages supplied and steady-state maximum current ratings | +5V @ 70A |
DC input voltage | -40.5 VDC to 72 VDC continuous |
Heat dissipation | 600 W (2040 Btu/hr) |
DC wire gauge | |
|
|