K Command for the LightStream  1010 ATM Switch

K Command for the LightStream  1010 ATM Switch

keepalive

Use the keepalive interface configuration command to set the keepalive timer for a specific interface. To turn off keepalives entirely, use the no form of this command.

keepalive [seconds]
no keepalive [seconds]
Syntax Description

seconds

Unsigned integer value greater than 0. The default is 10 seconds.

Default

10 seconds

Command Mode

Interface configuration

Usage Guidelines

This command does not apply to ATM interfaces. Refer to the atm ilmi-keepalive command for configuration of keepalives on ATM interfaces.

You can configure the keepalive interval, which is the frequency at which the switch sends messages to itself (Ethernet) or to the other end (auxiliary), to ensure a network interface is alive. The interval is adjustable in one-second increments down to one second. An interface is declared down after three update intervals pass without receiving a keepalive packet.

Setting the keepalive timer to a low value is useful for detecting Ethernet interface failures (transceiver cable disconnecting, cable unterminated, and so on).

A typical serial line failure involves losing CD. Since this sort of failure is typically noticed within a few milliseconds, adjusting the keepalive timer for faster routing recovery is generally not useful.


Note When adjusting the keepalive timer for a low bandwidth auxiliary interface, datagrams can delay the smaller keepalive packets long enough to cause the line protocol to go down. You might need to experiment to determine the best value.
Example

The following example sets the keepalive interval to 3 seconds.

Switch(config)# interface ethernet 2/0/0
Switch(config-if)# keepalive 3
Related Command