This chapter describes procedures for confirming the successful hardware installation and initial configuration of the ATM switch processor (ASP), and includes the following sections:
Problems with the initial startup are often caused by an interface processor or power supply that has become dislodged from the backplane or chassis power connector during shipment. Although over-temperature conditions rarely occur at initial startup, the environmental monitoring functions are included because they also monitor DC line voltages. At the initial system boot, verify the following:
When these conditions are met, the hardware installation is complete. If the startup sequence fails before these conditions are met, use the procedures in this chapter to isolate and, if possible, resolve the problem. If you are unable to solve the problem, contact a customer service representative for assistance and further instructions. Before you call, gather the following information:
The following example shows the first few screens from the output of the show diag power-on command:
Switch> show diag power-on
LS1010 Power-on Diagnostics Status (.=Pass,F=Fail,U=Unknown,N=Not Applicable)
-----------------------------------------------------------------------------
Last Power-on Date: 97/04/14 Time: 16:03:22
BOOTFLASH: . PCMCIA-Slot0: . PCMCIA-Slot1: N
CPU-IDPROM: . FCard-IDPROM: . NVRAM-Config: .
SRAM: . DRAM: .
PS1: . PS2: N PS (12V): .
FAN: . Temperature: . Bkp-IDPROM: F
MMC-Switch Access: . Accordian Access: .
LUT: . ITT: . OPT: . OTT: . STK: . LNK: . ATTR: . Queue: .
Cell-Memory: .
Feature-Card Access: .
ICC: . OCC: . OQP: . OQE: . CC: . RT: .
TM0: . TM1: . TMC: . IT: . LT: . RR: . ABR: .
Access/Interrupt/Loopback/CPU-MCast/Port-MCast/FC-MCast/FC-TMCC Test Status:
Ports 0 1 2 3
----------------------------------------------------------------------------
PAM 0/0 (T1CE) ....... ....... ....... .......
PAM 0/1 (155MM) ....... ....... ....... .......
PAM 1/0 (155MM) ....... ....... ....... .......
PAM 1/1 (155MM) ....... ....... ....... .......
PAM 3/0 (155UTP) ....... ....... ....... .......
PAM 3/1 (DS3Q) ....... ....... ....... .......
PAM 4/0 (T1CE) ....... ....... ....... .......
Ethernet-port Access: . Ethernet-port CAM-Access: .
Ethernet-port Loopback: . Ethernet-port Loadgen: .
When the information about PAMs appears in the output, if a failure occurs, an "F" displays and a period (.) indicates the test passed.
The flowchart in Figure 4-1 helps you determine which component of your LightStream 1010 ATM switch might have malfunctioned.

This section describes the LEDs used to confirm and troubleshoot operation of the ASP. The LEDs on the ASP indicate the status of the ASP, fan assembly, and power supplies. The ASP LEDs are shown in Figure 4-2 and described in Table 4-1.

| LED | Color | Description |
|---|---|---|
Green | The system has passed internal self-tests and diagnostic tests. | |
| Red | The system has failed internal self-tests and diagnostic tests. |
| Orange | The system is booting or a module is disabled. |
Green | The fan is operational. | |
| Red | The fan is not operational. |
Green | The power supply is operational. | |
| Red | The power supply is installed but not operational. |
| Off | The power supply is not installed. |
Green | The power supply is operational. | |
| Red | The power supply is installed but not operational. |
| Off | The power supply is not installed. |
Green | The Ethernet port is operational. | |
| Off | No signal is detected on the Ethernet port. |
Flashing green | Ethernet packets are being received. The pulse rate increases with the data rate. | |
| Off | No signal is being received. |
Flashing green | Ethernet packets are being transmitted. The pulse rate increases with the data rate. | |
| Off | No signal is being transmitted. |
Table 4-2 describes some commands you can enter in privileged EXEC mode to verify that the hardware, software, and interfaces have been configured correctly.
| Command | Description |
|---|---|
Displays the version and type of software installed. | |
Displays the type and revision number of the hardware installed in the system. | |
show interface ethernet card/subcard/port | Displays the Ethernet configuration. |
Displays the ATM address. | |
Tests for connectivity between the switch and a host. | |
Displays the configuration of the ATM interfaces. (Press Ctrl z to stop the display messages.) | |
Displays the status of the ATM interfaces. | |
Displays the status of the ATM virtual interfaces. | |
Displays the configuration being used. | |
Displays the configuration saved in NVRAM. |
|
|