This chapter discusses the initial configuration of the LightStream 1010 Asynchronous Transfer mode (ATM) switch. Because the LightStream 1010 offers true plug-and-play operation, most users may not need to perform any of these procedures.
The LightStream 1010 is shipped with the ATM address autoconfigured to an address assigned by Cisco Systems. This feature lets the switch automatically configure attached end systems using the Interim Local Management Interface (ILMI) protocol and automatically establishes itself as a node in a single-level Private Network-Network Interface (PNNI) routing domain.
The ILMI and PNNI protocols, when used with such IP address autoconfiguration mechanisms as BOOTP, allow the LightStream 1010 to be entirely self-configured. Through network management applications and the text-based command line interface (CLI), the switch's network operator has the capability, if desired, to configure and customize all aspects of the operation of the switch.
An IP address must be assigned to allow up to eight simultaneous Telnet sessions to connect to the switch or to use Simple Network Management Protocol (SNMP) network management for the switch. The Ethernet IP address can be assigned either manually or by a BOOTP server. See the section "Configuring Ethernet IP Interface Parameters."
For definitions of all commands discussed in this chapter, refer to the publication LightStream 1010 ATM Switch Command Reference.
You should have already have made a copy of the "Port Configuration Worksheets" from the appendix "Configuration Worksheets" in the LightStream 1010 ATM Switch Software Configuration Guide, and completed a worksheet for your switch.
Before powering up your system, check for correct AC or DC power voltages. See the appendix "System Chassis Specifications" for correct power voltages.
The following warning applies to AC power supplies:
![]() | Warning This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on the phase conductors (all current-carrying conductors). To see translated versions of this warning, refer to the appendix "Translated Safety Warnings." |
The following warnings and cautions applies to DC power supplies:
![]() | Caution This product relies on protective devices in the building installation for protection against short-circuit overcurrent, and earth faults. Ensure that a fuse or circuit breaker no larger than 48 VDC, 20A is provided for the 48VDC source in the United States and Canada (60 VDC, 15A for the 60VDC internationally). |
![]() | Warning Before installing a DC-input power supply, ensure that all power is off to the DC input circuit. Locate the circuit breaker on the panel board that services the DC circuit and switch it to the off position. Tape the circuit breaker switch handle in the off position to prevent accidental closing of the circuit. |
![]() | Warning Care must be given to connecting units to the supply circuit so that wiring is not overloaded. To see translated versions of this warning, refer to the appendix "Translated Safety Warnings." |
Now you can safely power up your system by turning on the power switch of the power supply to be used.
When you first power up your console and LightStream 1010, a screen similar to the following appears:
Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706
Cisco Internetwork Operating System Software
IOS (tm) PNNI Software (LS1010-WP-M), Version 11.2(1.4.WA3.0.41)
Copyright (c) 1986-1997 by cisco Systems, Inc.
Compiled Tue 11-Feb-97 02:59 by
Image text-base: 0x600108D0, data-base: 0x603EE000
The first section of the script displays the banner information, including the software version.
The next portion of the script lists installed hardware configuration.
cisco ASP1 (R4600) processor with 16384K bytes of memory. R4600 processor, Implementation 32, Revision 2.0 Last reset from power-on 1 Ethernet/IEEE 802.3 interface. 16 ATM network interfaces. 125K bytes of non-volatile configuration memory. 8192K bytes of Flash PCMCIA card at slot 0 (Sector size 128K). 8192K bytes of Flash internal SIMM (Sector size 256K). Press RETURN to get started! Switch>
Use the show hardware command to confirm installed hardware part and serial numbers:
Switch#show hardware
LS1010 named Switch, Date: 14:26:42 UTC Fri Feb 14 1997
Feature Card's FPGA Download Version: 10
Slot Ctrlr-Type Part No. Rev Ser No Mfg Date RMA No. Hw Vrs Tst EEP
---- ------------ ---------- -- -------- --------- -------- ------- --- ---
0/0 155UTP PAM 75-1574-02 03 36434547 Mar 19 98 02-02-02 3.2 2 2
0/1 155UTP PAM 75-2010-03 06 35866442 Mar 18 98 02-02-02 3.2 2 2
1/0 155UTP PAM 75-2010-03 06 35866462 Mar 19 98 02-02-02 3.2 2 2
1/1 155UTP PAM 75-2010-03 06 35887734 Mar 11 98 02-02-02 3.2 2 2
3/1 QUAD DS3 PAM 75-2711-02 02 37211062 #) 18 98 02-02-02 3.2 2 2
2/0 ATM Swi/Proc 73-1402-04 A0 03827617 Oct 19 96 00-00-00 3.2 0 2
2/1 FeatureCard1 73-1405-03 B0 03825722 Oct 19 96 00-00-00 3.2 0 2
DS1201 Backplane EEPROM:
Model Ver. Serial MAC-Address MAC-Size RMA RMA-Number MFG-Date
------ ---- -------- ------------ -------- --- ---------- -----------
LS1010 2 68000003 00400B0A1080 256 0 0 Jan 19 1996
Switch#
The LightStream 1010 should be operating correctly and transferring data. To confirm that the hardware and software installation and configuration procedures were successful, see the chapter "Confirming the Installation."
|
|