This chapter describes troubleshooting procedures used to confirm that the hardware and software installation and configuration procedures were successful.
When each of these conditions is met, the hardware installation is complete, and you should proceed to the chapter "Configuring the LightStream 1010 ATM Switch." If the startup sequence fails before these conditions are met, use the procedures in this chapter to isolate and, if possible, resolve the problem. If you are unable to easily solve the problem, contact a customer service representative for assistance and further instructions. Before you call, have the following information ready to help your service provider assist you as quickly as possible:
Figure 5-1 is an example of a power-on diagnostics display.
Switch#show diag power-on
LS1010 Power-on Diagnostics Status (.=Pass,F=Fail,U=Unknown,N=Not Applicable)
-----------------------------------------------------------------------------
Last Power-on Date: 96/06/12 Time: 06:33:44
BOOTFLASH: . PCMCIA-Slot0: N PCMCIA-Slot1: N
CPU-IDPROM: . FCard-IDPROM: . NVRAM-Config: .
SRAM: . DRAM: .
PS1: . PS2: F PS (12V): .
FAN: . Temperature: . Bkp-IDPROM: .
MMC-Switch Access: . Accordian Access: .
LUT: . ITT: . OPT: . OTT: . STK: . LNK: . ATTR: . Queue: .
Cell-Memory: .
Feature-Card Access: .
ICC: . OCC: . OQP: . OQE: . CC: . RT: .
TM0: . TM1: . TMC: . IT: . LT: . RR: . ABR: .
Access/Interrupt/Loopback/CPU-MCast/Port-MCast/FC-MCast/FC-TMCC Test Status:
Ports 0 1 2 3
----------------------------------------------------------------------------
PAM 0/0 (622SM) ....... N N N
PAM 0/1 (622SM) ....... N N N
PAM 1/0 (155UTP) ....... ....... ....... .......
PAM 1/1 (155MM) ....... ....... ....... .......
PAM 3/0 (DS3) ....... ....... N N
PAM 3/1 (DS3) ....... ....... N N
PAM 4/0 (E3) ....... ....... N N
PAM 4/1 (E3) ....... ....... N N
Ethernet-port Access: . Ethernet-port CAM-Access: .
Ethernet-port Loopback: . Ethernet-port Loadgen: .
If a failure occurs, an "F" is inserted instead of the period (.) which indicate that the test passed. For example, in Figure 5-1, power-supply two (PS2) failed the power-on diagnostics test.
Figure 5-2 is a flowchart to help you determine which component of your LightStream 1010 may have malfunctioned.

|
|