|
|
The LightStream 1010 ATM switch processor (ASP) specifications are described in Table B-1.
For the LightStream 1010 ATM switch chassis and common equipment specifications, refer to the appendix "System Chassis Specifications" in the LightStream 1010 ATM Switch Hardware Installation Guide. For port adapter module (PAM) specifications, refer to the appendix "CM and PAM Specifications" in the LightStream 1010 ATM Switch PAM Installation Guide.
| Description | Specifications |
|---|---|
5-Gbps shared memory, nonblocking switch fabric | |
Software images | Default image with PNNI1 |
ASP: 1.2 x 14.4 x 16 in. (3.0 x 36.6 x 40.6 cm) | |
6.85 lb (3.09 kg) | |
DC voltages supplied and steady-state maximum current ratings | System: +5V @ 70A |
32 to 104ºF (0 to 40ºC) | |
Nonoperating temperature | -40 to 167ºF (-40 to 75ºC) |
10 to 90%, noncondensing | |
-500 to 10,000 ft. (-52 to 3048 m) | |
100-MHz MIPS2 R4700 | |
8-MB Flash memory SIMM (upgradable to 16 MB) | |
Interface timing | Loop timing, Stratum 4 accuracy clock for self-timing, master clock distribution port |
Management access | Standard Ethernet and dual EIA/TIA-2329 serial ports on the ASP |
32,000 point-to-point, 2048 multi-to-multipoint | |
RJ-45 IEEE17 802.3 Ethernet 10BaseT port | |
Network management | Port TX18 and RX19 LEDs20, switch and common equipment status LEDs |
SNMP MIB II (RFC 1213) | |
Safety: UL27 1950, CSA-C22.228 No. 950, EN60950, IEC95029, TS001 |
| 1PNNI = Private Network-Network Interface. 2MIPS = MultiChannel Interface Processor. 3DRAM = dynamic random-access memory. 4FC-PCQ = feature card per-class queueing. 5FC-PFQ = feature card per-flow queueing. 6EPROM = erasable programmable read-only memory. 7SRAM = static random-access memory. 8PCMCIA = Personal Computer Memory Card International Association. 9EIA/TIA = Electronic Industries Association/Telecommunications Industry Association. 10VC = virtual channel. 11VP = virtual path. 12PVC = permanent virtual circuit. 13SVC = switched virtual circuit. 14OAM = Operations, Administration, and Maintenance. 15RDI = remote defect identification. 16AIS = alarm indication signal. 17IEEE = Institute of Electrical and Electronics Engineers. 18TX = transmit. 19RX = receive. 20LEDs = light emitting diodes. 21FC-PFQ supports per-VC, per-VP, and per-port snooping. 22MIBs = Management Information Bases. 23TACACS = Terminal Access Control Access System. 24TFTP = Trivial File Transfer Protocol. 25RFC = Request For Comments. 26ILMI = Interim Local Management Interface. 27UL = Underwriters Laboratory. 28CSA = Canadian Standards Association. 29IEC = International Electrotechnical Commission. 30EMI = electromagnetic interference. |
|
|